Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION MICROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Submicron mass spectrometry imaging of single cells by combined use of mega electron volt time-of-flight secondary ion mass spectrometry and scanning transmission ion microscopy

In order to better understand biochemical processes inside an individual cell, it is important to measure the molecular composition at the submicron level. One of the promising mass spectrometry imaging techniques that may be used to accomplish this is Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS), using MeV energy heavy ions for excitation. MeV ions have the ability to desorb large intact molecules with a yield that is several orders of magnitude higher than conventional SIMS using keV ions. In order to increase the spatial resolution of the MeV TOF-SIMS system, we propose an independent TOF trigger using a STIM (scanning transmission ion microscopy) detector that is placed just behind the thin transmission target. This arrangement is suitable for biological samples in which the STIM detector simultaneously measures the mass distribution in scanned samples. The capability of the MeV TOF-SIMS setup was demonstrated by imaging the chemical composition of CaCo-2 cells.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-scale imaging of high-pressure hydrogen induced damage in EPDM rubber using X-ray microcomputed tomography, helium-ion microscopy and transmission electron microscopy

Ethylene propylene diene (EPDM) rubber has gained increasing interest for use in hydrogen infrastructure due to its excellent sealing performance and low temperature properties. However, severe structural damage has been observed in EPDM O-rings after exposure to high-pressure hydrogen. The origination and propagation mechanisms of this damage are poorly understood. Here, to address this knowledge gap, multi-scale imaging leveraging X-ray micro-computed tomography (micro-CT), helium ion microscopy (HeIM), and transmission electron microscopy (TEM) were used in this work to study a series of sulfur-cured ethylene propylene diene (EPDM) rubber materials with varying additives that were exposed to different hydrogen environments. Micro-CT captured the substantial structural damage due to hydrogen exposure; it revealed an association between zinc oxide (ZnO) particles and damage initiation. Further studies by TEM and scanning TEM with energy dispersive X-ray spectroscopy (EDS) were focused on these particles at the micro-to nano-scale range. TEM indicated that hydrogen causes void formation at the interface between ZnO and the rubber matrix. HeIM enabled imaging of surface morphology of the material at high resolution pre- and post-hydrogen exposure while providing information on chemical composition and that cannot be captured by either micro-CT or TEM.

08 HYDROGEN↗

Use of LEED, Auger emission spectroscopy and field ion microscopy in microstructural studies.

The studies reported were conducted to gain a fundamental understanding of adhesion and dynamic friction on an atomic or microscopic level. Fundamental aspects of low energy electron diffraction (LEED), Auger emission spectroscopy (AES), and field ion microscopy (FIM) are discussed. Typical results of studies conducted are considered, giving attention to LEED-AES experiments, pin and disk experiments, and field ion microscope investigations.

Ferrante, J.↗

Helium Ion Microscopy for Imaging and Quantifying Porosity at the Nanoscale

Nanoporous materials are essential components in a vast number of applications from energy to drug delivery and to agriculture. Yet, the number of ways to analytically quantify the salient features of these materials, for example: surface structure, pore shape, and size, remain limited. The most common approach is gas absorption, where volumetric gas absorption and desorption are measured. This technique has some fundamental drawbacks such as low sample throughput and a lack of direct surface visualization. In this work, we demonstrate Helium Ion Microscopy (HIM) as a tool for imaging and quantification of pores in industrially relevant SiO 2 catalyst supports. We start with the fundamental principles of ion-sample interaction, and build on this knowledge to experimentally observe and quantify surface pores by using the HIM and image data analytics. We contrast our experimental results to gas absorption and demonstrate full statistical agreement between two techniques. The principles surrounding the theoretical, experimental, and analytical framework presented herein offer an automated framework for visualization and quantification of pore structures in a wide variety of materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First-principles simulation of light-ion microscopy of graphene

The extreme sensitivity of 2D materials to defects and nanostructure requires precise imaging techniques to verify presence of desirable and absence of undesirable features in the atomic geometry. Helium-ion beams have emerged as a promising materials imaging tool, achieving up to 20 times higher resolution and 10 times larger depth-of-field than conventional or environmental scanning electron microscopes. Here, we offer first-principles theoretical insights to advance ion-beam imaging of atomically thin materials by performing real-time time-dependent density functional theory simulations of single impacts of 10–200 keV light ions in free-standing graphene. Here we predict that detecting electrons emitted from the back of the material (the side from which the ion exits) would result in up to three times higher signal and up to five times higher contrast images, making 2D materials especially compelling targets for ion-beam microscopy. This predicted superiority of exit-side emission likely arises from anisotropic kinetic emission. The charge induced in the graphene equilibrates on a sub-fs time scale, leading to only slight disturbances in the carbon lattice that are unlikely to damage the atomic structure for any of the beam parameters investigated here.

36 MATERIALS SCIENCE↗

Adhesion and transfer of polytetrafluoroethylene to tungsten studied by field ion microscopy

Mechanical contacts between polytetrafluoroethylene (PTFE) and tungsten field ion tips were made in situ in the field ion microscope. Both load and force of adhesion were measured for varying contact times and for clean and contaminated tungsten tips. Strong adhesion between the PTFE and clean tungsten was observed at contact times greater than 2.5 min (forces of adhesion were greater than three times the load). For times less than 2.5 min, the force of adhesion was immeasurably small. The increase in adhesion with contact time after 2.5 min can be attributed to the increase in true contact area by creep of PTFE. No adhesion was measurable at long contact times with contaminated tungsten tips. Neon field ion micrographs taken after the contacts show many linear and branched arrays which appear to represent PTFE that remains adhered to the surface even at the high electric fields required for imaging.

Brainard, W. A.↗

Ion microscopy with resonant ionization mass spectrometry : time-of-flight depth profiling with improved isotopic precision.

There are four generally mutually exclusive requirements that plague many mass spectrometric measurements of trace constituents: (1) the small size (limited by the depth probed) of many interesting materials requires high useful yields to simply detect some trace elements, (2) the low concentrations of interesting elements require efficient discrimination from isobaric interferences, (3) it is often necessary to measure the depth distribution of elements with high surface and low bulk contributions, and (4) many applications require precise isotopic analysis. Resonant ionization mass spectrometry has made dramatic progress in addressing these difficulties over the past five years.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Field-ion microscopy of ordered Cu-Au alloy.

A method is proposed for overcoming current difficulties in measuring atomic order parameters of nonrefractory metals when using the field-ion microscope (FIM). Near stoichiometric CuAu and Cu3Au were tested by means of this method. Images of substantially fully ordered CuAu and Cu3Au thus obtained are presented and discussed.

Son, U. T.↗

Ta–Zr carbides: Synthesis advances via carbothermal reduction and defect evolution observed through transmission electron microscopy ion irradiation

The thermodynamic stability of six distinct compositions within the Zr—Ta—C ternary system is investigated in this study, marking the first report of their synthesis through carbothermic reduction in vacuum. A prolonged annealing process at 2200°C enabled high densification and phase equilibrium. Detailed phase identification and microstructural characterization through microscopy and X-ray diffraction techniques revealed clear compositional trends and stable phase formations. Two compositions ((Ta 0.2 Zr 0.8 )C 0.6 and (Ta 0.5 Zr 0.5 )C 1 ) were selected for ion irradiation experiments using 200 keV Kr + at 600°C—representing the first-ever irradiation study on the Zr—Ta—C system. The findings indicated defect accumulation and nanoscale cavity formation without any evidence of amorphization, highlighting the system's structural stability under irradiation. Together, the synthesis and irradiation results provide a basis for further investigation of the system and suggest its relevance for applications under extreme environments.

36 MATERIALS SCIENCE↗

In situ liquid cell crystallization and imaging of thiamethoxam by helium ion microscopy

Pest insect control is an essential component for crop protection and public health. Neonicotinoids are a relatively new class of insecticides developed in the last four decades. Thiamethoxam, a member of the neonicotinoid class, has shown outstanding potency for crop protection against a variety of piercing-sucking pests. However, its use in industrial-volume packing and transportation is complicated by crystallization dynamics. In this work, a helium ion microscope (HIM) with a Protochips liquid cell was utilized to crystallize and image thiamethoxam in situ . The results of the study illustrate the growth and morphology of the thiamethoxam crystals at different He + exposure doses, which is markedly different from what has been typically observed. Energy-dispersive x-ray spectroscopy results confirm the presence of the thiamethoxam on the liquid cell membrane. This imaging study illustrates the HIM ability to image and induce the crystallization in soft materials in liquid environments, and attempts to shed light onto the key processes involved in liquid imaging.

60 APPLIED LIFE SCIENCES↗