Search NASA⌕ Search

SEARCH · Search NASA

Results for “IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Compression Ratio Ion Mobility Programming (CRIMP) Accumulation and Compression of Billions of Ions for Ion Mobility-Mass Spectrometry Using Traveling Waves in Structures for Lossless Ion Manipulations (SLIM)

We report on the implementation of a traveling wave (TW) based compression ratio ion mobility programming (CRIMP) approach within Structures for Lossless Ion Manipulations (SLIM) that enables both greatly enlarged trapped ion charge capacities and also their subsequent efficient compression for use in ion mobility (IM) separations. Ion accumulation is conducted in a long serpentine path TW SLIM region after which CRIMP allows the large ion populations to be ‘squeezed’. The compression process occurs at an interface between two SLIM regions, one operating conventionally and the second having an intermittently pausing or ‘stuttering’ TW, allowing the contents of multiple bins of ions from the first region to be merged into a single bin in the second region. In this initial work stationary voltages in the second region were used to block ions from exiting the first (trapping) region, and the resumption of TWs in the second region allows ions to exit, and the population to also be compressed if CRIMP is applied. In our initial evaluation we show that the number of charges trapped for a 40 s accumulation period was ~5×109, more than two orders of magnitude greater than the previously reported charge capacity using an ion funnel trap. We also show that over 1×109 ions can be accumulated with high efficiency in the present device, and that the extent of subsequent compression is only limited by the space charge capacity of the trapping region. Lower compression ratios allow increased IM peak heights without significant loss of signal, while excessively large compression ratios can lead to ion losses and other artifacts. Importantly, we show that extended ion accumulation in conjunction with CRIMP and multiple passes provides the basis for a highly desirable combination of ultra-high sensitivity and ultra-high resolution IM separations using SLIM.

Environmental Molecular Sciences Laboratory↗

Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion source

The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current ({approx}100 {micro}A) with high charge ({approx}10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.

43 PARTICLE ACCELERATORS↗

Single-Ion Tracks in Gd2Zr2-xTixO7 Pyrochlores Irradiated with Swift Heavy Ions

Swift xenon ions (1.43 GeV) were used to systematically investigate the radiation response of pyrochlores in the Gd2Zr2-xTixO7 binary in the electronic energy loss regime. Ion-induced structural modifications were characterized by synchrotron x-ray diffraction, Raman spectroscopy and transmission electron microscopy. In general, individual ion tracks consist of amorphous domains (in the core of the track) and are surrounded by a crystalline, but disordered structure (track shell), and finally, by a defect-rich region (track halo). The size and structure of these concentric regions, which form dynamically in single ion tracks, depend on the chemical composition. The overall extent of the radiation damage strongly increases with Ti-content, and this confirms the enhanced radiation stability of Zr-rich pyrochlore, even within single swift heavy ion tracks.

43 PARTICLE ACCELERATORS↗

Temporal evolution of ion energy distribution functions and ion charge states of Cr and Cr-Al pulsed arc plasmas

To study the temporal evolution of ion energy distribution functions, charge-state-resolved ion energy distribution functions of pulsed arc plasmas from Cr and Cr-Al cathodes were recorded with high time resolution by using direct data acquisition from a combined energy and mass analyzer. The authors find increases in intensities of singly charged ions, which is evidence that charge exchange reactions took place in both Cr and Cr-Al systems. In Cr-Al plasmas, the distributions of high-charge-state ions exhibit high energy tails 50 μs after discharge ignition, but no such tails were observed at 500 μs. The energy ratios of ions of different charge states at the beginning of the pulse, when less neutral atoms were in the space in front of the cathode, suggest that ions are accelerated by an electric field. The situation is not so clear after 50 μs due to particle collisions. The initial mean ion charge state of Cr was about the same in Cr and in Cr-Al plasmas, but it decreased more rapidly in Cr-Al plasmas compared to the decay in Cr plasma. The faster decay of the mean ion charge state and ion energy caused by the addition of Al into a pure Cr cathode suggests that the mean ion charge state is determined not only by ionization processes at the cathode spot but also by inelastic collision between different elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

From Isolated Ions to Multilayer Functional Materials Using Ion Soft Landing

The ability to deposit intact polyatomic ions with well-defined composition, charge state, and kinetic energy onto surfaces makes preparative mass spectrometry, also called ion soft-landing, particularly attractive for preparing uniform molecular and ionic layers. Early studies characterized structures, charge states, and reactivity of sparsely distributed soft-landed species. Recent development of high-flux ionization sources has opened up new opportunities for the precisely-controlled preparation of both two-dimensional assemblies and three-dimensional multilayer architectures using ion soft-landing. Previously unknown phenomena have been uncovered following deposition of large numbers of ions onto supports thereby opening several exciting research directions in this field. Furthermore, faster ion deposition has enabled fabrication of novel functional devices. This review discusses important phenomena and highlights key developments pertaining to preparation of well-defined interfaces for studies in energy storage, catalysis, soft materials, and biology.

Laskin, Julia↗

Production and ion-ion cooling of highly charged ions in electron string ion source

The scheme of an internal injection of Au atoms into the working space of the ''Krion-2'' electron string ion source (ESIS) was applied and tested. In this scheme Au atoms are evaporated from the thin tungsten wire surface in vicinity of the source electron string. Ion beams with charge states up to Au{sup 51+} were produced. Ion-ion cooling with use of C and O coolant ions was studied. It allowed increasing of the Au{sup 51+} ion yield by a factor of 2. Ions of Kr up to charge state 28+ were also produced in the source. Electron strings were first formed with injection electron energy up to 6 keV. Methods to increase the ESIS ion output are discussed.

43 PARTICLE ACCELERATORS↗

Molecular ion sources for low energy semiconductor ion implantation (invited)

Smaller semiconductors require shallow, low energy ion implantation, resulting space charge effects, which reduced beam currents and production rates. To increase production rates, molecular ions are used. Boron and phosphorous (or arsenic) implantation is needed for P-type and N-type semiconductors, respectively. Carborane, which is the most stable molecular boron ion leaves unacceptable carbon residue on extraction grids. A self-cleaning carborane acid compound (C{sub 4}H{sub 12}B{sub 10}O{sub 4}) was synthesized and utilized in the ITEP Bernas ion source resulting in large carborane ion output, without carbon residue. Pure gaseous processes are desired to enable rapid switch among ion species. Molecular phosphorous was generated by introducing phosphine in dissociators via 4PH{sub 3} = P{sub 4} + 6H{sub 2}; generated molecular phosphorous in a pure gaseous process was then injected into the HCEI Calutron-Bernas ion source, from which P{sub 4}{sup +} ion beams were extracted. Results from devices and some additional concepts are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase stability in thermally-aged CASS CF8 under heavy ion irradiation

The stability of the microstructure of a cast austenitic stainless steel (CASS), before and after heavy ion irradiation, was investigated by atom probe tomography (APT). A CF8 ferrite–austenite duplex alloy was thermally aged at 400 °C for 10,000 h. After this treatment, APT revealed nanometer-sized G-phase precipitates and Fe-rich α and Cr-enriched α' phase separated regions in the ferrite. The thermally-aged CF8 specimen was irradiated with 1 MeV Kr ions to a fluence of 1.88 × 10 19 ions/m 2 at 400 °C. After irradiation, APT analysis revealed a strong spatial/dose dependence of the G-phase precipitates and the α–α' spinodal decomposition in the ferrite. For the G-phase precipitates, the number density increased and the mean size decreased with increasing dose, and the particle size distribution changed considerably under irradiation. The inverse coarsening process can be described by recoil resolution. The amplitude of the α–α' spinodal decomposition in the ferrite was apparently reduced after heavy ion irradiation.

Li, Meimei↗

Ion partitioning between brines and ion exchange polymers

Quantitative failure of the ideal Donnan model to predict ion partitioning between relatively dilute electrolyte aqueous solutions and ion exchange polymers arises from neglecting non-ideal behavior of ions. Hypothetically, when a water swollen, charged polymer is equilibrated with concentrated salt solutions, most of the fixed charge groups are neutralized by sorbed counter-ions, which can screen electrostatic effects and create, in the membrane, an environment thermodynamically similar to that experienced by ions in the external electrolyte solution. In this study, a combined experimental and theoretical approach was used to test this hypothesis. A fundamental study of ion partitioning between a cation exchange membrane based on cross-linked poly(p-styrene sulfonate-co-divinylbenzene) and NaCl and CaCl2 concentrated brines is presented. At high electrolyte concentrations, the experimentally measured ion activity coefficients in the membrane match those in the contiguous external solution, and the ideal Donnan model provides an accurate prediction of co-ion and counter-ion concentrations in the polymer. This physical picture was further confirmed by the recently developed Manning-Donnan model.

catalysis (heterogeneous)↗

Hydrodynamic description of an unmagnetized plasma with multiple ion species. II. Two and three ion species plasmas

Paper I [A. N. Simakov and K. Molvig, Phys. Plasmas23, 032115 (2016)] obtained a fluid description for an unmagnetized collisional plasma with multiple ion species. To evaluate collisional plasmatransport fluxes, required for such a description, two linear systems of equations need to be solved to obtain corresponding transport coefficients. In general, this should be done numerically. Herein, the general formalism is used to obtain analytical expressions for such fluxes for several specific cases of interest: a deuterium-tritium plasma; a plasma containing two ion species with strongly disparate masses, which agrees with previously obtained results; and a three ion species plasma made of deuterium, tritium, and gold. We find that these results can be used for understanding the behavior of the aforementioned plasmas, or for verifying a code implementation of the general multi-ion formalism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-induced fluorescence measurements of argon and xenon ion velocities near the sheath boundary in 3 ion species plasmas

The Bohm sheath criterion is studied with laser-induced fluorescence in three ion species plasmas using two tunable diode lasers. Krypton is added to a low pressure unmagnetized DC hot filament discharge in a mixture of argon and xenon gas confined by surface multi-dipole magnetic fields. The argon and xenon ion velocity distribution functions are measured at the sheath-presheath boundary near a negatively biased boundary plate. The potential structures of the plasma sheath and presheath are measured by an emissive probe. Results are compared with previous experiments with Ar–Xe plasmas, where the two ion species were observed to reach the sheath edge at nearly the same speed. This speed was the ion sound speed of the system, which is consistent with the generalized Bohm criterion. In such two ion species plasmas, instability enhanced collisional friction was demonstrated [Hershkowitz et al., Phys. Plasmas 18(5), 057102 (2011).] to exist which accounted for the observed results. When three ion species are present, it is demonstrated under most circumstances the ions do not fall out of the plasma at their individual Bohm velocities. It is also shown that under most circumstances the ions do not fall out of the plasma at the system sound speed. These observations are also consistent with the presence of the instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Evaluation and Optimization of Structures for Lossless Ion Manipulations for Ion Mobility Spectrometry with Time-of-Flight Mass Spectrometry

We report on the performance of Structures for Lossless Ion Manipulation (SLIM) devices as a means for transmitting ions and performing ion mobility separations (IMS). Ions were successfully transferred from an electrospray ionization (ESI) source to the TOF MS analyzer by means of a linear SLIM device and an alternative arrangement including a 90° turn. First, the linear geometry was optimized for radial confinement by tuning RF on the central ‘rung’ electrodes and potentials on the DC-only guard electrodes. Selecting an appropriate DC guard bias (2-6 V) and RF amplitude (≥160 Vp-p at 750 kHz) resulted in the greatest ion intensities. Close to ideal IMS resolving power was maintained over a range of applied voltages. Second, the 90° turn was optimized for radial confinement by tuning the RF on the rung electrodes and DC on the guard electrodes; however, both resolving power and ion transmission showed a dependence on these voltages and the best conditions for both were > 300 Vp-p RF (685 kHz) and 7-11 V guard DC bias. Both geometries provide IMS resolving powers at the theoretical limit (R~58), showing that the negative “racetrack” effect from turning around a corner can be successfully avoided, as well as the capability for essentially lossless ion transmission.

conveyor↗

Impact of Confinement and Zwitterionic Ligand Chemistry on Ion–Ion Selectivity of Functionalized Nanopores

Membranes incorporating zwitterionic chemistries have recently emerged as promising candidates for facilitating challenging ion–ion separations. Transport of ions in such membranes predominantly occurs in hydrated nanopores lined with zwitterionic monomers. Here, to shed light on the physics of ion–ion selectivity underlying such materials, we conducted molecular dynamics simulations of sodium halide transport in model nanopores grafted with sulfobetaine methacrylate molecules. Our results reveal that in both functionalized and unfunctionalized nanopores smaller ions prefer to reside near the pore center, while the larger ions tend to reside near the pore walls. An enhancement in the selective transport of larger anions is observed within the unfunctionalized nanopores relative to that in salt-in-water solutions. Upon functionalization of the nanopores with zwitterions (ZIs), the disparities in the anionic distribution profiles within the pores coupled with differences in the anion-ZI interactions result in a slowdown of larger anions relative to smaller anions. Increasing the ZI grafting density exacerbates these effects, further promoting the selective transport of smaller anions. Our results suggest that selectivity toward large anions can be realized by using nanoporous membranes with ZI content that is high enough to facilitate ion/water partitioning into the pores while preserving the characteristic tendency of the unfunctionalized pores to facilitate faster transport of the larger anions. On the other hand, selectivity toward smaller anions can be achieved by targeting ZI content within the pores that is high enough to significantly slow down the transport of large anions but not high enough to hinder the partitioning of ions/water molecules into the pore due to steric effects.

anions↗

Multiple species beam production on laser ion source for electron beam ion source in Brookhaven National Laboratory

Extracted ion beams from the test laser ion source (LIS) were transported through a test beam transport line which is almost identical to the actual primary beam transport in the current electron beam ion source apparatus. The tested species were C, Al, Si, Cr, Fe, Cu, Ag, Ta, and Au. The all measured beam currents fulfilled the requirements. However, in the case of light mass ions, the recorded emittance shapes have larger aberrations and the RMS values are higher than 0.06 π mm mrad, which is the design goal. Since we have margin to enhance the beam current, if we then allow some beam losses at the injection point, the number of the single charged ions within the acceptance can be supplied. For heaver ions like Ag, Ta, and Au, the LIS showed very good performance.

43 PARTICLE ACCELERATORS↗