At least 37 records · Page 2

The Ionization Profile Monitors in the Recycler Ring

The ionization profile monitors (IPMs) are used to measure the beam size in synchrotrons. Both the Fermilab Recycler and Main Injector (MI) machines have IPMs. However, they were not well understood enough to provide confidence in their measurements. Accurately measuring beam size through the IPMs was crucial to recognize the loss mechanisms for accelerators and to keep the beam loss to a minimum. Thus, performing measurements with different parameters using the IPMs led to a better analysis on how changes in conditions affect the beam size. The IPM measurements are compared with that of multi-wires in the upstream transfer line after applying corrections. The results were compared with other diagnostics and the change in the beam size for different parameters are presented in this paper.

43 PARTICLE ACCELERATORS↗

On the Convergence of Inexact Predictor-Corrector Methods for Linear Programming

Interior point methods (IPMs) are a common approach for solving linear programs (LPs) with strong theoretical guarantees and solid empirical performance. The time complexity of these methods is dominated by the cost of solving a linear system of equations at each iteration. In common applications of linear programming, particularly in machine learning and scientific computing, the size of this linear system can become prohibitively large, requiring the use of iterative solvers, which provide an approximate solution to the linear system. However, approximately solving the linear system at each iteration of an IPM invalidates the theoretical guarantees of common IPM analyses. To remedy this, we theoretically and empirically analyze (slightly modified) predictor-corrector IPMs when using approximate linear solvers: our approach guarantees that, when certain conditions are satisfied, the number of IPM iterations does not increase and that the final solution remains feasible. We also provide practical instantiations of approximate linear solvers that satisfy these conditions for special classes of constraint matrices using randomized linear algebra.

Dexter, Gregory↗

AN EMPIRICAL RECONSTRUCTION OF THE 2008 APRIL 26 CORONAL MASS EJECTION

We present a three-dimensional model of the density distribution of a coronal mass ejection (CME) from 2008 April 26. This CME was observed by the two spacecraft composing the Solar Terrestrial Relations Observatory (STEREO), which tracked the CME from near the Sun, into the interplanetary medium (IPM), and all the way to 1 AU. The CME was directed toward STEREO-B and hit that spacecraft on 2008 April 29. The STEREO images of the CME show an internal structure that can be interpreted as having a flux rope shape. The two different perspectives on the event provided by the two STEREO spacecraft allow us to make a particularly strong argument for the flux rope interpretation, and the STEREO data also allow us to study the evolution of the flux rope in the IPM. The flux rope is oriented close to the ecliptic plane, but with the western leg tilted northwards by about 20 deg. This implies an orientation roughly perpendicular to the neutral line of the active region at the event's point of origin, apparently an unusual geometry given that previous analyses have found that CME flux ropes are usually, but not always, oriented parallel to the neutral lines of their source regions. The CME model also consists of a front out ahead of the flux rope, possibly a shock launched by the flux rope driver. The model density distribution is reasonably successful at reproducing the CME appearance both close to the Sun in coronagraphic images, and far from the Sun in images of the IPM from STEREO's heliospheric imagers. This suggests that self-similar expansion is a reasonable first-order approximation for this particular CME, and also indicates that the flux rope's orientation does not change much during its journey through the IPM.

79 ASTRONOMY AND ASTROPHYSICS↗

Emittance measurements using Vernier Scans during Run 09 (pp at 250 GeV)

Emittance measurements using the vernier scan technique give reliable results for 250 GeV protons even though the transverse beam profiles have non-Gaussian tails. Those non-Gaussian tails were observed for the first time this run at the 250 GeV beam energy. The vernier scan measurements are in excellent agreement with the emittances derived from collision rates and show practically no fill to fill scatter if compared to the latter. The results are consistent with a {beta}* of 0.7 m and round beams. The IPM measurements show a discrepancy of up to 80% compared with the vernier scan data and a fill to fill scatter of up to 30%. If an uncertainty in the beta-function at the location of the IPM is the root cause, this uncertainty seems to be quite large. In any case, such an uncertainty could not explain the fill to fill variations of up to 30% which indicate yet another underlying reason that could explain fill to fill variations (candidates could be beam intensity issues with the IPM, beam position at the IPM, varying background etc.).

43 PARTICLE ACCELERATORS↗

Integrated Process Model Utilization and Development for Inertial Fusion Energy

This CRADA between LLNS and Longview Fusion Energy Systems utilized a modernized LLNL Integrated Process Model (IPM) to assess technoeconomic viability and power plant configurations for Inertial Fusion Energy (IFE). During the collaboration period, a streamlined IPM model was produced by LLNL, which consolidated a combination of 3 models under one file. Additionally, obsolete parameters were removed and parameters available for trade space analysis were organized in a user-friendly fashion on the front interface. Gain scaling curves were discussed and analyzed in the framework of the IPM. Additional updates were made to account for cost scaling to today's dollars using an average inflation rate. Heat transfer material costing was updated using a ground up approach with public vendor data. Further levelized cost of electricity (LCOE) methods and models were discussed and reviewed for applicability to the IPM. Prior published literature on optical scaling was also discussed. Moreover, as part of this CRADA, the Participant developed a fusion technology development roadmap and point designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated Process Model Utilization and Development for Inertial Fusion Energy

This CRADA between LLNS and Longview Fusion Energy Systems utilized a modernized LLNL Integrated Process Model (IPM) to assess technoeconomic viability and power plant configurations for Inertial Fusion Energy (IFE). During the collaboration period, a streamlined IPM model was produced by LLNL, which consolidated a combination of 3 models under one file. Additionally, obsolete parameters were removed and parameters available for trade space analysis were organized in a user-friendly fashion on the front interface. Gain scaling curves were discussed and analyzed in the framework of the IPM. Additional updates were made to account for cost scaling to today's dollars using an average inflation rate. Heat transfer material costing was updated using a ground up approach with public vendor data. Further levelized cost of electricity (LCOE) methods and models were discussed and reviewed for applicability to the IPM. Prior published literature on optical scaling was also discussed. Moreover, as part of this CRADA, the Participant developed a fusion technology development roadmap and point designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operational Use of Ionization Profile Monitors in the Fermilab Main Injector

Ionization profile monitors (IPMs) are used in the Fermilab Main Injector (MI) to monitor injection lattice matching by measuring turn-by-turn sigmas at injection and to measure transverse emittance of the beam during the acceleration cycle. The IPMs provide a periodic, non-destructive means of performing turn-by-turn emittance measurements where other techniques are not applicable. As Fermilab is refocusing its attention on the intensity frontier, non-intercepting diagnostics such as IPMs are expected to become even more important. This paper gives an overview of the operational use of IPMs for emittance measurements and injection lattice matching measurements at Fermilab, and summarizes the future plans.

43 PARTICLE ACCELERATORS↗

A simulation study of atmospheric mercury and its deposition in the Great Lakes

The Great Lakes eco-region is one of the largest sources of fresh water in North America; however it is chronically exposed to heavy metal loadings such as mercury. In this study a comprehensive model evaluation was conducted to determine mercury loadings to the Great Lakes. The study also evaluated the relative impact of anthropogenic mercury emissions from China, regional and global sources on deposition to the Great Lakes. For the 2005 study period, CMAQ 4.7.1 model estimated a total of 6.4 ± 0.5 metric tons of mercury deposited in the Great Lakes. The total deposition breakdown showed a net loading for Lake Superior of 1906 ± 246 kg/year which is the highest of all the lakes. Lake Michigan followed with 1645 ± 203 kg/year and 1511 ± 107 kg/year in Lake Huron. The lowest total deposition was seen in Lakes Erie and Ontario amassing annual totals of 837 ± 107 kg and 506 ± 63 kg, respectively. Wet and dry deposition of mercury were both significant pathways and exhibited strong seasonal variability with higher deposition occurring in the warmer months (June–November) and the lowest in winter. Wet deposition of RGM significantly influenced the deposition proportions accounting for roughly 90% of all mercury deposited. Of the three emission sources (global background, integrated planning management (IPM) and Chinese), global background concentrations represented the maximum impact to deposition loading in the Great Lakes, except for Lake Erie and parts of Lake Michigan. There was minimal seasonality for the global background, but differences in percentage contribution between dry (28–97%) and wet deposition (43–98%) was predicted. The contributions were seen mainly in the northern sections of the Great Lakes further away from IPM point sources. These findings suggest strong localized impact of IPM sources on the southernmost lakes. Deposition as a result of emissions from China exhibited seasonality in both wet and dry deposition and showed significant contributions ranging from 0.2 to 9%.

Chinese emissions↗

Characterization of two 2-isopropylmalate synthase homologs from Thermus thermophilus HB27

2-Isopropylmalate synthase (IPMS) catalyzes the first step of leucine biosynthesis and is regulated via feedback inhibition by leucine. The thermophilic bacterium, Thermus thermophilus HB27, has two IPMS homologous genes: TTC0847 and TTC0849, both of which are in the branched-chain amino acid biosynthetic gene cluster. Since enzymes involved in the leucine biosynthetic pathway are evolutionarily related to those in isoleucine biosynthesis, TTC0847 and TTC0849 are expected to function as IPMS or citramalate synthase, which is the first enzyme in the isoleucine biosynthetic pathway from pyruvate. We characterized these proteins in vitro and in vivo, and revealed that TTC0849 plays a key role in the biosynthesis of leucine and isoleucine, whereas TTC0847 is only involved in that of isoleucine.

60 APPLIED LIFE SCIENCES↗

Pelvic Nodal Dosing With Registration to the Prostate: Implications for High-Risk Prostate Cancer Patients Receiving Stereotactic Body Radiation Therapy

Purpose: To determine whether image guidance with rigid registration (RR) to intraprostatic markers (IPMs) yields acceptable coverage of the pelvic lymph nodes in the context of a stereotactic body radiation therapy (SBRT) regimen. Methods and Materials: Four to seven kilovoltage cone-beam CTs (CBCTs) from 12 patients with high-risk prostate cancer were analyzed, allowing approximation of an SBRT regimen. The nodal clinical target volume (CTV{sub N}) and bladder were contoured on all kilovoltage CBCTs. The V{sub 100} CTV{sub N}, expressed as a ratio to the same parameter on the initial plan, and the magnitude of translational shift between RR to the IPMs versus RR to the pelvic bones, were computed. The ability of a multimodality bladder filling protocol to minimize bladder height variation was assessed in a separate cohort of 4 patients. Results: Sixty-five CBCTs were assessed. The average V{sub 100} CTV{sub N} was 92.6%, but for a subset of 3 patients the average was 80.0%, compared with 97.8% for the others (P<.0001). The average overall and superior–inferior axis magnitudes of the bony-to-fiducial translations were significantly larger in the subgroup with suboptimal nodal coverage (8.1 vs 3.9 mm and 5.8 vs 2.4 mm, respectively; P<.0001). Relative bladder height changes were also significantly larger in the subgroup with suboptimal nodal coverage (42.9% vs 18.5%; P<.05). Use of a multimodality bladder-filling protocol minimized bladder height variation (P<.001). Conclusion: A majority of patients had acceptable nodal coverage after RR to IPMs, even when approximating SBRT. However, a subset of patients had suboptimal nodal coverage. These patients had large bony-to-fiducial translations and large variations in bladder height. Nodal coverage should be excellent if the superior–inferior axis bony-to-fiducial translation and the relative bladder height change (both easily measured on CBCT) are kept to a minimum. Implementation of a strict bladder filling protocol may achieve this goal.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and Prototyping of an Ionization Profile Monitor for the SNS Accumulator Ring

An ionization profile monitor (IPM) has been designed for the Spallation Neutron Source (SNS) accumulator ring. Utilizing ionized electrons produced by beam-gas ionization, the SNS IPM uses a 120 kV bias potential to overcome beam space charge and accelerate electrons towards a movable particle detector. A 300 G magnetic field is used to confine the transverse electron motion, resulting in profile errors at the estimated 7% level. With a system bandwidth of 17.5 MHz. The SNS IPM is capable of measuring turn-by-turn beam profiles for a fully accumulated beam. This paper presents a description of the system and design.

Bartkoski, Dirk A↗

NEW DEVELOPMENTS ON INVERSE POLYGON MAPPING TO CALCULATE GRAVITATIONAL LENSING MAGNIFICATION MAPS: OPTIMIZED COMPUTATIONS

We derive an exact solution (in the form of a series expansion) to compute gravitational lensing magnification maps. It is based on the backward gravitational lens mapping of a partition of the image plane in polygonal cells (inverse polygon mapping, IPM), not including critical points (except perhaps at the cell boundaries). The zeroth-order term of the series expansion leads to the method described by Mediavilla et al. The first-order term is used to study the error induced by the truncation of the series at zeroth order, explaining the high accuracy of the IPM even at this low order of approximation. Interpreting the Inverse Ray Shooting (IRS) method in terms of IPM, we explain the previously reported N {sup -3/4} dependence of the IRS error with the number of collected rays per pixel. Cells intersected by critical curves (critical cells) transform to non-simply connected regions with topological pathologies like auto-overlapping or non-preservation of the boundary under the transformation. To define a non-critical partition, we use a linear approximation of the critical curve to divide each critical cell into two non-critical subcells. The optimal choice of the cell size depends basically on the curvature of the critical curves. For typical applications in which the pixel of the magnification map is a small fraction of the Einstein radius, a one-to-one relationship between the cell and pixel sizes in the absence of lensing guarantees both the consistence of the method and a very high accuracy. This prescription is simple but very conservative. We show that substantially larger cells can be used to obtain magnification maps with huge savings in computation time.

97 MATHEMATICS AND COMPUTING↗

Ionization profile monitors for the IOTA proton beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors — one vertical and one horizontal — are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. Furthermore, in this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

Beam diagnostics↗

Absolute beam emittance measurements at RHIC using ionization profile monitors

In the past, comparisons between emittance measurements obtained using ionization profile monitors, Vernier scans (using as input the measured rates from the zero degree counters, or ZDCs), the polarimeters and the Schottky detectors evidenced significant variations of up to 100%. In this report we present studies of the RHIC ionization profile monitors (IPMs). After identifying and correcting for two systematic instrumental errors in the beam size measurements, we present experimental results showing that the remaining dominant error in beam emittance measurements at RHIC using the IPMs was imprecise knowledge of the local beta functions. After removal of the systematic errors and implementation of measured beta functions, precise emittance measurements result. Also, consistency between the emittances measured by the IPMs and those derived from the ZDCs was demonstrated.

43 PARTICLE ACCELERATORS↗

A New Perspective for the Calibration of Computational Predictor Models.

This paper presents a framework for calibrating computational models using data from sev- eral and possibly dissimilar validation experiments. The offset between model predictions and observations, which might be caused by measurement noise, model-form uncertainty, and numerical error, drives the process by which uncertainty in the models parameters is characterized. The resulting description of uncertainty along with the computational model constitute a predictor model. Two types of predictor models are studied: Interval Predictor Models (IPMs) and Random Predictor Models (RPMs). IPMs use sets to characterize uncer- tainty, whereas RPMs use random vectors. The propagation of a set through a model makes the response an interval valued function of the state, whereas the propagation of a random vector yields a random process. Optimization-based strategies for calculating both types of predictor models are proposed. Whereas the formulations used to calculate IPMs target solutions leading to the interval value function of minimal spread containing all observations, those for RPMs seek to maximize the models' ability to reproduce the distribution of obser- vations. Regarding RPMs, we choose a structure for the random vector (i.e., the assignment of probability to points in the parameter space) solely dependent on the prediction error. As such, the probabilistic description of uncertainty is not a subjective assignment of belief, nor is it expected to asymptotically converge to a fixed value, but instead it is a description of the model's ability to reproduce the experimental data. This framework enables evaluating the spread and distribution of the predicted response of target applications depending on the same parameters beyond the validation domain (i.e., roll-up and extrapolation).

Crespo, Luis Guillermo↗

A New Perspective for the Calibration of Computational Predictor Models

This paper presents a framework for calibrating computational models using data from several and possibly dissimilar validation experiments. The offset between model predictions and observations, which might be caused by measurement noise, model-form uncertainty, and numerical error, drives the process by which uncertainty in the models parameters is characterized. The resulting description of uncertainty along with the computational model constitute a predictor model. Two types of predictor models are studied: Interval Predictor Models (IPMs) and Random Predictor Models (RPMs). IPMs use sets to characterize uncertainty, whereas RPMs use random vectors. The propagation of a set through a model makes the response an interval valued function of the state, whereas the propagation of a random vector yields a random process. Optimization-based strategies for calculating both types of predictor models are proposed. Whereas the formulations used to calculate IPMs target solutions leading to the interval value function of minimal spread containing all observations, those for RPMs seek to maximize the models’ ability to reproduce the distribution of observations. Regarding RPMs, we choose a structure for the random vector (i.e., the assignment of probability to points in the parameter space) solely dependent on the prediction error. As such, the probabilistic description of uncertainty is not a subjective assignment of belief, nor is it expected to asymptotically converge to a fixed value, but instead it is a description of the model’s ability to reproduce the experimental data. This framework enables evaluating the spread and distribution of the predicted response of target applications depending on the same parameters beyond the validation domain (i.e., roll-up and extrapolation).

42 ENGINEERING↗

Ionization Profile Monitors for the IOTA Proton Beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. In this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

43 PARTICLE ACCELERATORS↗

Design of Ionization Profile Monitors at the Integrable Optics Test Accelerator Facility at Fermilab

The Integrable Optics Test Accelerator (IOTA) at Fermilab is transitioning from an electron beam facility to a proton beam facility for studies in nonlinear accelerator optics and space-charge dominated proton beams. This project involves the commissioning and fabrication of Ionization Profile Monitors (IPMs) to enable beam profile measurements at IOTA. In general, IPMs work on principle of residual gas ionization by the beam to generate beam profile. This work focuses on a mechanical design that leverages a controlled injection of noble gases, primarily Argon, as the ultra-high vacuum of the IOTA ring provides insufficient residual gas for ionization. Efforts to understand vacuum integration to ensure compatibility with the storage ring environment, the integration of real-time data acquisition systems and the commissioning of the IPMs will be discussed. This project provides a versatile diagnostic tool, supporting IOTA’s role as a testbed for larger-scale accelerator facilities and contributing to the broader understanding of beam physics in high-intensity, high-space-charge regimes.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057↗