Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image Transmission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Obtaining a tomographic image from transmission projections

Technique for obtaining tomographic images work directly in signal space and is used to find object configuration by simple summation of density values. Image is reconstructed by precise inverse of scanning. Signal values corresponding to density of projection are added as constant terms along line corresponding to original path between two probes that give rise to that density value.

Heyser, R. C.↗

Bandwidth compression of the digitized HDTV images for transmission via satellites

This paper investigates a subband coding scheme to reduce the transmission bandwidth of the digitized HDTV images. The HDTV signals are decomposed into seven bands. Each band is then independently encoded. The based band is DPCM encoded and the high bands are encoded by using nonuniform Laplacian quantizers with a dead zone. By selecting the dead zone on the basis of energy in the high bands an acceptable image quality is achieved at an average of 45 Mbits/sec (Mbps) rate. This rate is comparable to some very hardware intensive schemes of transform compression or vector quantization proposed in the literature. The subband coding scheme used in this study is considered to be of medium complexity. The 45 Mbps rate is suitable for transmission of HDTV signals via satellites.

Al-Asmari, A. KH.↗

Transmission of Images on High-Temperature Nuclear-Grade Metallic Pipe with Ultrasonic Elastic Waves

Transmission of information using elastic ultrasonic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall, with minimal modification of the existing hardware. Because bit rates on the order of kilobits per second are achievable, relatively large volumes of data, such as images, can be transmitted. A viable candidate for an ultrasonic communication channel is a stainless steel pipe of the chemical volume control system (CVCS) that penetrates through the reactor containment building wall through a sealed tunnel. To study ultrasonic communication under simulated nuclear facility conditions of high temperature, a test article was developed by installing heating tapes, temperature controllers, and thermal insulation on a laboratory CVCS-like stainless steel pipe. High temperature and radiation-resilient lithium niobate ultrasonic transducers were utilized for information transmission on the heated pipe. The amplitude shift keying (ASK) digital communication protocol was developed and implemented in a GNU Radio software-defined radio environment. A root-raised-cosine filter was introduced to suppress ultrasonic transducer ringing and thus reduce inter-symbol interference. This resulted in the enhancement of the data transmission bit rate compared to information encoding with square pulses. Demonstrations of communication at high temperature included transmission of a 90-KB image at the bit rate of 10 Kbps with a bit error rate of 10 -3 across a 6-ft-long straight pipe heated up to 230 degrees C. Additional preliminary studies were conducted to evaluate ultrasonic communication system resilience to environmental degradation and damage.

42 ENGINEERING↗

Visualizing Intrinsic 3D-Strain Distribution in Gold Coated ZnO Microstructures by Bragg Coherent X-Ray Diffraction Imaging and Transmission Electron Microscopy with Respect to Piezotronic Applications

Novel devices ranging from bio magnetic field sensors to energy harvesting nano machines utilize the piezotronic effect. For optimal function, understanding the interaction of electrical and strain phenomena within the semiconductor crystal is necessary. Here, studies of a model piezotronic system are presented, consisting of a ZnO microrod coated by a thin layer of gold, which forms a Schottky contact with the piezoelectric ZnO material. Coherent X-ray diffraction imaging (CXDI) and transmission electron microscopy (TEM) are used to visualize the structure and strain distribution, showing that the ZnO microrod exhibits strains of multiple origins in the bulk and at the interface. Strain values of -6 × 10 -4 have been measured by CXDI at the ZnO/Au interface. The origin is shown to be a combination of an interface strain, possibly caused by the Schottky contact formation, and distinct, localized electrical fields inside the crystal which are assigned to electron depletion and screening in a bent ZnO/Au piezotronic rod. These findings will contribute to sensor development and to a better understanding of piezotronic applications.

36 MATERIALS SCIENCE↗

Ultrafast time-resolved 2D imaging of laser-driven fast electron transport in solid density matter using an x-ray free electron laser

High-power, short-pulse laser-driven fast electrons can rapidly heat and ionize a high-density target before it hydrodynamically expands. The transport of such electrons within a solid target has been studied using two-dimensional (2D) imaging of electron-induced Kα radiation. However, it is currently limited to no or picosecond scale temporal resolutions. Here, we demonstrate femtosecond time-resolved 2D imaging of fast electron transport in a solid copper foil using the SACLA x-ray free electron laser (XFEL). An unfocused collimated x-ray beam produced transmission images with sub-micron and ~10 fs resolutions. The XFEL beam, tuned to its photon energy slightly above the Cu K-edge, enabled 2D imaging of transmission changes induced by electron isochoric heating. Time-resolved measurements obtained by varying the time delay between the x-ray probe and the optical laser show that the signature of the electron-heated region expands at ~25% of the speed of light in a picosecond duration. Time-integrated Cu Kα images support the electron energy and propagation distance observed with the transmission imaging. The x-ray near-edge transmission imaging with a tunable XFEL beam could be broadly applicable for imaging isochorically heated targets by laser-driven relativistic electrons, energetic protons, or an intense x-ray beam.

47 OTHER INSTRUMENTATION↗

Gamma-Ray and Cosmic Ray Muon Modalities for Cargo Inspection

Screening and inspection of cargo containers are two essential methods to nondestructively examine the contents of shipment. These methods enable the detection of illicit transportation of unauthorized materials such as nuclear and radioactive materials, explosives, drugs, and so on, typically at borders or secure facilities. Although high-energy X-ray transmission is a standard system and is widely used for cargo inspection, the inherent challenges of high false-positive rates and high attenuation factors necessitate the development of complementary techniques that can increase the detection efficiency and accuracy in large and dense materials. Gamma-rays, which possess higher penetration characteristics because of their high energy, offer an alternative nonintrusive modality for cargo scanning. They represent a promising inspection method when compared to X-rays for three reasons: (1) improved ability to detect nuclear and radioactive materials, (2) higher inspection throughput rates, and (3) lower false-positive rates. Currently, there are two main gamma-ray inspection techniques, active and passive interrogation. Active interrogation can be further grouped into (1) gamma-ray transmission imaging and (2) neutron-induced gamma-ray emission detection. Gamma-ray transmission imaging utilizes differences in material densities for mapping the shipment contents and detecting anomalies. It is analogous to the X-ray transmission method; however, the high-energy photons make it more difficult to shield against, which enables more efficient performance in large and dense material inspection. Neutron-induced gamma-ray emission inspection is designed for the detection of nuclear and radioactive material because those materials emit characteristic gamma-rays when they are activated by neutron absorption. On the other hand, passive interrogation techniques rely on high-efficiency detectors to detect radiation emitted from hidden special nuclear or other radioactive materials. Similar to passive interrogation, cosmic ray muon monitoring and imaging are relatively new techniques that do not require external radioactive sources. These techniques have received attention as a potential next-generation radiographic probe to identify illicit transportation of nuclear and radioactive materials in cargo containers. Cosmic ray muons have unique features, (1) much higher energies than X-rays or gamma-rays (on the order of 10−1—104 GeV), (2) enhanced penetration capability, and (3) natural occurrence, thereby eliminating the need for induced radiation sources. These features enable cosmic ray muons to be utilized for detection of special nuclear materials in high-background-noise environments. By analyzing incoming and outgoing muon trajectories, scattering angles, and energies, it has been shown that it would be possible to locate hidden and well-shielded materials in cargo containers via three-dimensional muon tomography images or signal analysis. Gamma-rays, cosmic ray muons, and other nonintrusive cargo inspection modalities are complementary to each other, allowing them to address various cargo inspection conditions (i.e., scanning time, cost, radiation exposure level, and types of target materials). This chapter presents a detailed review of the theoretical fundamentals and technical principles behind the current gamma-ray and cosmic ray muon modalities for cargo inspection. Additionally, critical assessments and suggestions for the future directions to advance the use of gamma and muon modalities are discussed.

Bae, Junghyun↗

A new ultrasonic imaging system using time delay spectrometry

A new method of forming a visual image by ultrasound is described. A shadowgraphic transmission image similar to an X-ray radiograph is produced by the application of a technique known as Time Delay Spectrometry. The system uses a repetitive frequency sweep with a linear relationship between frequency and time and the transmitting and receiving crystal are scanned in raster fashion about the subject. By electronic processing, an image may be built up which represents the energy transmitted through the specimen with a given time delay. An intensity modulated picture encompassing the full shades-of-gray capability of the recording system can be produced. A second type of image showing transmission time through the specimen may also be formed. Brightness changes in the displayed image in this case correspond to changes in the ultrasonic transmission time through the specimen.

Heyser, R. C.↗

Grating-Based Imaging-Scattering with Portable Neutron Generator

Company: Adelphi Technology, Inc. Title: Grating-Based Imaging-Scattering with Portable Neutron Generator PI: Dr. Jay Theodore Cremer, Jr. Topic: 26a Statement of the problem or situation that is being addressed. Successful plant growth depends upon an efficient and robust root system. The plant root is part of a larger system of water and microbial flows in the soil system. While much effort has been exerted to develop an imaging system for water, microbes, and roots, the problem is challenging, and no widely accepted imaging method currently exists. The optical solutions use a highly modified soil system. X-ray imaging methods are insensitive to the soft tissues in the presence of sand. Thermal neutron imaging has been often tested, but found inadequate, due to limited access and low image resolution. This project will develop a new strategy for neutron imaging of plant/soil systems. The project will allow long duration experiments in greenhouse environments and increase the image information content to the micron scale. General statement of how this problem is being addressed. Portable, rugged thermal and fast neutron sources are being developed where portable means a two-soldier team can carry the source and power unit to survey rough terrain for explosives. In the past decade, microfabrication of X-ray and thermal/cold neutron optics has opened a new imaging strategy. The standard transmission image is now supplemented with simultaneous acquisition of a phase contrast image and an image revealing scattering features. In materials science, the interferometric neutron scattering image has been used to detect early crack formation in stressed additive manufacturing test samples. The detection requires sensitivity to scattering features at the 1-micron scale. By addition of our proposed grating-optic to Adelphi Technology’s radiographic/tomographic imaging system, which is based on portable thermal neutron source, the resulting thermal neutron scatter image of the plant/soil system, will reveal details at 1-micron. Commercial Applications and Other Benefits Neutron interferometry imaging has greater penetration through large metal components compared to industrial X-ray imaging. The low-cost, large area optics developed for greenhouse applications, combined with the robust, portable neutron generator, can then be marketed as a system for inspection of additive manufactured components. In the aerospace industry, all freshly printed components are validated with X-ray CT. Scheduled maintenance again requires X-ray CT as the ability to predict aerospace component lifetime does not yet exist. Large aerospace components are only partially observed with X-ray imaging. Key Words Neutron radiography/tomography, grating interferometry, thermal neutron generator imaging, plant root and soil imaging, rhizosphere imaging, deployable neutron imaging systems Summary for Members of Congress A rugged, portable source of thermal neutrons is adapted for neutron interferometry imaging with the addition of low-cost, 3D printed optics. The first application of our proposed deployable, compact thermal neutron generator imaging system, using a grating optic, is plant root/soil science in greenhouse settings and agricultural laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast image decompression for telebrowsing of images

Progressive image transmission (PIT) is often used to reduce the transmission time of an image telebrowsing system. A side effect of the PIT is the increase of computational complexity at the viewer's site. This effect is more serious in transform domain techniques than in other techniques. Recent attempts to reduce the side effect are futile as they create another side effect, namely, the discontinuous and unpleasant image build-up. Based on a practical assumption that image blocks to be inverse transformed are generally sparse, this paper presents a method to minimize both side effects simultaneously.

Miaou, Shaou-Gang↗

Deep Learning Segmentation of Complex Features in Atomic-Resolution Phase-Contrast Transmission Electron Microscopy Images

Phase-contrast transmission electron microscopy (TEM) is a powerful tool for imaging the local atomic structure of materials. TEM has been used heavily in studies of defect structures of two-dimensional materials such as monolayer graphene due to its high dose efficiency. However, phase-contrast imaging can produce complex nonlinear contrast, even for weakly scattering samples. It is, therefore, difficult to develop fully automated analysis routines for phase-contrast TEM studies using conventional image processing tools. For automated analysis of large sample regions of graphene, one of the key problems is segmentation between the structure of interest and unwanted structures such as surface contaminant layers. In this study, we compare the performance of a conventional Bragg filtering method with a deep learning routine based on the U-Net architecture. We show that the deep learning method is more general, simpler to apply in practice, and produces more accurate and robust results than the conventional algorithm. We provide easily adaptable source code for all results in this paper and discuss potential applications for deep learning in fully automated TEM image analysis.

47 OTHER INSTRUMENTATION↗

Neutron Imaging of Al6061 Prepared by Solid-State Friction Stir Additive Manufacturing

Solid-state Friction Stir Additive Manufacturing has recently gained attention as a result of its capacity to fabricate large-scale parts while preserving the mechanical properties of the feedstock material. However, the correlation between the quality of layer-by-layer bonding of the deposited metal and processing parameters has remained unknown. Neutron imaging techniques, with 90% total transmission per cm, are employed for Al6061 parts fabricated by MELD ® Technology as a non-destructive evaluation approach for the first time to investigate the layer-by-layer structure of a stadium-shaped ingot in different sections. The post-processed results show the fabricated parts with an optimized set of processing parameters are void-free. However, the hydrocarbon-based feedstock lubricant segregates between the layers, which consequently may lead to non-uniform weaker mechanical properties along the build direction and stimulate crack initiation during mechanical loading. The tensile test results show 14% lower strain-to-failure values in alleged contaminated areas in transmission imaging results. Additionally, layer bonding is significantly impacted by hot-on-hot and hot-on-cold layer deposition schemes, especially for larger layer thicknesses.

36 MATERIALS SCIENCE↗

Polarized neutron measurements of the internal magnetization of a ferrimagnet across its compensation temperature

We present the first polarized neutron transmission image of a model Néel ferrimagnetic material, polycrystalline terbium iron garnet (Tb 3 Fe 5 O 12 , TbIG for short), as it is taken through its compensation temperature T comp where the macroscopic magnetization vanishes. Our polarized neutron imaging data and the additional supporting measurements using neutron spin echo spectroscopy and SQUID magnetometry are all consistent with a vanishing internal magnetization at T comp .

Ferrimagnetism↗

Orthogonal spatial coding with stimulated parametric down-conversion

Orthogonal optical coding is widely used in classical multi-user communication networks. Using the phase conjugation property of stimulated parametric down-conversion, we extend the current time-domain orthogonal optical coding scheme to the spatial domain to encode and decode image information. In this process, the idler beam inherits the complex conjugate of the field information encoded in the seed beam. An encoding phase mask introduced onto the input seed beam blurs the image transferred to the idler. The original image is restored by passing the coded transferred image through a corrective phase mask placed in the momentum space of the idler beam. We expect that this scheme can also inspire new techniques in secure image transmission, aberration cancellation, and frequency conversion imaging.

Xu, Yang↗

Investigating the dielectric properties of barium titanate nanocomposites using transmission electron microscopy image processing

Abstract Barium titanate (BTO) is a ferroelectric perovskite material used in energy storage applications because of its high dielectric constant. A previous study showed that the dielectric constant for BTO nanoparticles drastically increases to over 15,000 at a particle size of 70 nm. This result is highly contested, but its implications to energy storage motivated our investigation into the dielectric constants of BTO nanoparticles that are incorporated into a polymer matrix. We developed a novel method of using image processing techniques on transmission electron microscope images of BTO-polymer nanocomposites. Data on the positions, shapes, sizes, and orientations of BTO nanoparticles were used to build more realistic computational models that simulate the dielectric behavior of the nanocomposites. Here, we investigate the relationship between regions of enhanced electric field and the composite dielectric constant.

36 MATERIALS SCIENCE↗

Image data compression investigation

NASA continuous communications systems growth has increased the demand for image transmission and storage. Research and analysis was conducted on various lossy and lossless advanced data compression techniques or approaches used to improve the efficiency of transmission and storage of high volume stellite image data such as pulse code modulation (PCM), differential PCM (DPCM), transform coding, hybrid coding, interframe coding, and adaptive technique. In this presentation, the fundamentals of image data compression utilizing two techniques which are pulse code modulation (PCM) and differential PCM (DPCM) are presented along with an application utilizing these two coding techniques.

Myrie, Carlos↗

Original images, ground truth annotations, and precited masks from U-NET for a fungal species x nitrogen experiment

This document describes the “MicroVision-MV003” dataset. This folder contains three subfolders: “originals”, “predicted_masks”, and “gt_masks”. The “originals” folder contains 720 original images acquired using two imaging modalities: 360 images from overhead imaging and 360 images from transmission (raw) imaging. Naming scheme:YYYY-MM-dd__plate_strain_nitrogen-level_replication_experiment_imaging-modalityYYYY-MM-dd: 2024-12-20, 2024-12-21, 2024-12-22,2024-12-23,2024-12-24,2024-12-25,2024-12-26,2024-12-27,2024-12-28,2024-12-29,2024-12-30,2024-12-31.plate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30.strain: FG, LE.nitrogen-level: N-1, N-10, N-100.replication: 1, 2, 3, 4, 5.experiment: MV.003.imaging-modality: overhead, transmission (raw). For example, the image2024-12-20__1_FG_N-10_3_MV.003_overheadwas taken on 2024-12-20. The plate number is 1, the fungal strain is FG, the nitrogen treatment is N-10, and the replication number is 3 for experiment MV.003, acquired using the overhead imaging modality. The “predicted_masks” folder contains masks generated by a trained U-Net model for the transmission imaging modality.The “gt_masks” folder contains 326 human hand-traced masks that serve as ground truth.

09 BIOMASS FUELS↗