Search NASASearch

SEARCH · Search NASA

Results for “Imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Thermal IR imaging system using a self-scanned HgCdTe/CCD detector array

It is likely that future high resolution earth observation imaging systems will utilize self-scanned IR detectors. In an initial step toward this goal, an IR imaging system operating in the 10 to 12 micron spectral region has been developed. This system uses a 9-element HgCdTe/CCD linear array operating in the photoconductive mode, nine pre-amplifiers and a silicon CCD multiplexer integrated into a focal plane assembly. Opto-mechanical techniques are used to scan the scene and images are produced in real time. The imaging performance of this system is described and measurements of noise, responsivity, specific detectivity, and detector sensitivity profiles are presented. The requirements for more advanced detector arrays for use in future NASA remote sensing missions are also discussed.

Husain-Abidi, A. S.

MRS proof-of-concept on atmospheric corrections. Atmospheric corrections using an orbital pointable imaging system

The feasibility of using a pointable imager to determine atmospheric parameters was studied. In particular the determination of the atmospheric extinction coefficient and the path radiance, the two quantities that have to be known in order to correct spectral signatures for atmospheric effects, was simulated. The study included the consideration of the geometry of ground irradiance and observation conditions for a pointable imager in a LANDSAT orbit as a function of time of year. A simulation study was conducted on the sensitivity of scene classification accuracy to changes in atmospheric condition. A two wavelength and a nonlinear regression method for determining the required atmospheric parameters were investigated. The results indicate the feasibility of using a pointable imaging system (1) for the determination of the atmospheric parameters required to improve classification accuracies in urban-rural transition zones and to apply in studies of bi-directional reflectance distribution function data and polarization effects; and (2) for the determination of the spectral reflectances of ground features.

Slater, P. N.

A physical parameter method for the design of broad-band X-ray imaging systems to do coronal plasma diagnostics

The technique commonly used for the analysis of data from broad-band X-ray imaging systems for plasma diagnostics is the filter ratio method. This requires the use of two or more broad-band filters to derive temperatures and line-of-sight emission integrals or emission measure distributions as a function of temperature. Here an alternative analytical approach is proposed in which the temperature response of the imaging system is matched to the physical parameter being investigated. The temperature response of a system designed to measure the total radiated power along the line of sight of any coronal structure is calculated. Other examples are discussed.

Kahler, S.

Transonic applications of the Wake Imaging System

The extension of a rapid flow field survey method (wake imaging system) originally developed for low speed wind tunnel operation, to transonic wind tunnel applications is discussed. The advantage of the system, beside the simplicity and low cost of the data acquisition system, is that the probe position data are recorded as an optical image of the actual sensor and thus are unaffected by the inevitable deflections of the probe support. This permits traversing systems which are deliberately flexible and have unusual motions. Two transverse drive systems are described and several typical data images are given.

Crowder, J. P.

Peformance evaluation of a passive microwave imaging system

A test program was conducted to evaluate the passive microwave imaging system for possible application in the NASA Earth Resources Program. In addition to test data analysis, the report gives a brief description of the radiometer, its software, and the ground support equipment. The microwave image quality is adequate for remote sensing applications studies. Instrument problems are described, and suggestions are given for possible improvements and potential applications.

Mcallum, W. E.

A real-time electronic imaging system for solar X-ray observations from sounding rockets

A real-time imaging system for displaying the solar coronal soft X-ray emission, focussed by a grazing incidence telescope, is described. The design parameters of the system, which is to be used primarily as part of a real-time control system for a sounding rocket experiment, are identified. Their achievement with a system consisting of a microchannel plate, for the conversion of X-rays into visible light, and a slow-scan vidicon, for recording and transmission of the integrated images, is described in detail. The system has a quantum efficiency better than 8 deg above 8 A, a dynamic range of 1000 coupled with a sensitivity to single photoelectrons, and provides a spatial resolution of 15 arc seconds over a field of view of 40 x 40 square arc minutes. The incident radiation is filtered to eliminate wavelengths longer than 100 A. Each image contains 3.93 x 10 to the 5th bits of information and is transmitted to the ground where it is processed by a mini-computer and displayed in real-time on a standard TV monitor.

Davis, J. M.

Thermal surveillance of Cascade Range volcanoes using ERTS-1 multispectral scanner, aircraft imaging systems, and ground-based data communication platforms

A combination of infrared images depicting areas of thermal emission and ground calibration points have proved to be particularly useful in plotting time-dependent changes in surface temperatures and radiance and in delimiting areas of predominantly convective heat flow to the earth's surface in the Cascade Range and on Surtsey Volcano, Iceland. In an integrated experiment group using ERTS-1 multispectral scanner (MSS) and aircraft infrared imaging systems in conjunction with multiple thermistor arrays, volcano surface temperatures are relayed daily to Washington via data communication platform (DCP) transmitters and ERTS-1. ERTS-1 MSS imagery has revealed curvilinear structures at Lassen, the full extent of which have not been previously mapped. Interestingly, the major surface thermal manifestations at Lassen are aligned along these structures, particularly in the Warner Valley.

Friedman, J. D.

Analysis and design of a refractive virtual image system

The optical performance of a virtual image display system is evaluated. Observation of a two-element (unachromatized doublet) refractive system led to the conclusion that the major source of image degradation was lateral chromatic aberration. This conclusion was verified by computer analysis of the system. The lateral chromatic aberration is given in terms of the resolution of the phosphor dots on a standard shadow mask color cathode ray tube. Single wavelength considerations include: astigmatism, apparent image distance from the observer, binocular disparities and differences of angular magnification of the images presented to each of the observer's eyes. Where practical, these results are related to the performance of the human eye. All these techniques are applied to the previously mentioned doublet and a triplet refractive system. The triplet provides a 50-percent reduction in lateral chromatic aberration which was the design goal. Distortion was also reduced to a minimum over the field of view. The methods used in the design of the triplet are presented along with a method of relating classical aberration curves to image distance and binocular disparity.

Kahlbaum, W. M.

Onboard processing for future space-borne imaging systems

There is a strong rationale for increasing the rate of information return from imaging class experiments aboard both terrestrial and planetary spacecraft. Future imaging systems will be designed with increased spatial resolution, broader spectral range and more spectral channels (or higher spectral resolution). The data rate implied by these improved performance characteristics can be expected to grow more rapidly than the projected telecommunications capability. One solution to this dilemma is the use of improved onboard data processing. The use of onboard classification processing in a multispectral imager can result in orders of magnitude increase in information transfer for very specific types of imaging tasks. Several of these processing functions are included in the conceptual design of an Infrared Multispectral Imager which would map the spatial distribution of characteristic geologic features associated with deposits of economic minerals.

Wellman, J. B.

Contrast changes in fluoroscopic imaging systems and statistical variations of these changes

Experimental studies have indicated that: (1) The response of digitized fluoroscopic imaging systems is linear systems is linear with contrast over a rather wide range of absorber and cavity thicknesses. (2) Contrast changes associated with the addition of aluminum, iodine containing contrast agents and air of thicknesses 1mm or less can be detected with a 95% confidence level. (3) The standard deviation associated with such determination using clinically available X-ray generators and video disc recording is less than 1 percent. A large flat screen X-ray image intensifier has been constructed and some preliminary results obtained. Sensitivity achieved makes dose reduction a factor often greater than previously reported for a system using a conventional X-ray image intensifier.

Bailey, N. A.

The MVM imaging system and its spacecraft interactions

The present work describes the main considerations and steps taken in determining the functional design of the imaging system of the Mariner Venus/Mercury (MVM) spacecraft and gives examples of some of the interactions between the spacecraft and the imaging instrument during the design and testing phases. Stringent cost and scheduling constraints dictated the use of the previous Mariner 9 dual-camera TV system. The TV parameters laid the groundwork for the imaging definition. Based on the flyby distances from Venus and Mercury and the goal of surface resolution better than 500 meters per sample pair, calculation was performed on focal length, format size, planetary coverage, and data rates. Some problems encountered in initial mechanical operation and as a result of spacecraft drift during the mission are also discussed.

Vescelus, F. E.