Absolute measurement of vacuum ultraviolet photon flux in an inductively coupled plasma using a Au thin film

A new method for absolute measurement of the vacuum ultraviolet (VUV) photon flux at the edge of a plasma is described. The light produced by the plasma was allowed to strike a negatively biased, gold-coated copper substrate remote from the plasma. The resulting photoelectron emission current was measured, and the absolute photon flux was then found from the known photoelectron yield of Au. The method was used to quantify the amount of VUV light produced by an Ar/He inductively coupled plasma (ICP). Strong emissions at 104.82 and 106.67 nm, corresponding to the 1s 2 and 1s 4 resonant states of Ar, were observed. The maximum, integrated VUV photon flux measured at the remote location was 3.2 × 10 13 photons/cm 2 s. This was estimated to correspond to a flux of 5 × 10 15 photons/cm 2 s at the edge of the ICP, in the range of reported values under similar conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Utilizing metal cation reactions with carbonyl sulfide to remove isobaric interferences in tandem inductively coupled plasma mass spectrometry analyses

Carbonyl sulfide (OCS) was used as a reaction gas to investigate gas phase metal (M + ) ion-molecule reactions using the Agilent 8900 inductively coupled plasma tandem mass spectrometer (ICP-MS/MS) to yield insight on how this gas may be used to remove isobaric interferences in analytical measurements. The experimental work was paired with density functional theory (DFT) calculations of the reaction enthalpy to predict whether M + will react with OCS. A multi-element standard containing 46 elements ranging from 9 to 208 u was analyzed in the presence and absence of OCS. When a reaction was observed, the dominant product was the sulfide (MS + ). Oxide products were also observed for many M + but formation was less efficient with OCS than previously observed with other reaction gases. This is likely due to the weaker OC-S bond that makes MS + formation more favorable. Increasing the flow rate from 0.1 to 0.2 mL/min (corresponding to a change in reaction gas pressure from 0.35 to 0.53 Pa (2.6 to 4.0 mTorr)) generally resulted in greater MS + production, including the secondary product MS 2 + for a few cations. The early lanthanide series ions (La + , Ce + , Pr + and Nd + ) produced greater quantities of MO + at the higher pressure, although MS + products were still the dominant product. The DFT-predicted reaction enthalpies were consistent with the observed sulfide formation, with an accuracy >90%; however, model predictions were less accurate for the minor and higher order products (< 77% for MO + ). Finally, the work presented here continues a systematic study of ion-molecule reactions in ICP-MS/MS to understand and develop new and novel ways to analyze complex mixtures with minimal pre-analysis treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An improved method for uranium separation from urine for rapid bioassay by inductively coupled plasma mass spectrometry

Bioassay monitoring is an important capability for any facility that works with significant amounts of radioactive material. The speed at which these analyses can be made is critical in the event of a potential exposure. Here, we present a new method that facilitates the rapid separation of uranium from a urine matrix for assay and isotopic determination by inductively coupled plasma mass spectrometry. This method is validated with archived urine samples that were previously analyzed using established, more time consuming methods. The sources of uncertainty for uranium assay and isotopic measurements are modelled using the Monte Carlo method to better understand the precision and accuracy of this method at the limit of quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Electron density measurement using a partially covered hairpin resonator in an inductively coupled plasma

Hairpin probes are used to determine electron densities via measuring the shift of the resonant frequency of the probe structure when immersed in a plasma. This manuscript presents new developments in hairpin probe hardware and theory that have enabled measurements in a high electron density plasma, up to approximately 10 12 cm -3 , corresponding to a plasma frequency of about 9 GHz. Hardware developments include the use of both quarter-wavelength and three-quarter-wavelength partially covered hairpin probes in a transmission mode together with an easily reproducible implementation of the associated microwave electronics using commercial off-the-shelf components. The three-quarter-wavelength structure is operated at its second harmonic with the purpose of measuring higher electron densities. New theory developments for interpreting the probe measurements include the use of a transmission line model to find an accurate relationship between the resonant frequency of the probe and the electron density, including effects of partially covering the probes with epoxy. Measurements are taken in an inductively coupled plasma sustained in argon at pressures below 50 mTorr. Results are compared with Langmuir probe and interferometry measurements.

47 OTHER INSTRUMENTATION↗

TOFHunter—unlocking rapid untargeted screening of inductively coupled plasma–time-of-flight–mass spectrometry data

This study provides an overview of a newly developed open source program written in Python, TOFHunter, which permits the rapid and untargeted screening of inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) datasets. ICP-TOF-MS is an analytical tool capable of providing quasi simultaneous detection of all nuclides from Li to Pu. This capability has triggered an increase in studies investigating single-particle analysis in which the TOF-MS provides correlated elemental/isotopic signatures on a particle basis in time. Similarly, laser ablation mapping has seen rapid growth owing to ICP-TOF-MS's capacity to handle fast washout times (<10 ms) while providing a broad nuclide coverage. The caveat to this broad mass coverage and high time resolution comes in the form of large, overwhelming datasets. With datasets typically on the scale of gigabytes, it is easy for a user to only focus on very targeted analytes; however, this focus diminishes the opportunity offered by the TOF-MS detector. TOFHunter applies chemometric methods, principal component analysis (PCA), and interesting features finder (IFF) on ICP-TOF-MS data, allowing for investigation of correlations, major and minor variance sources, and sample screening. The unique spectra identified by the (IFF) are used to generate a list of mass peaks, which are then matched with both nuclides and potential interferences before being exported for the user to investigate. Several case studies are discussed herein, demonstrating TOFHunter's ability to screen aqueous injections, single-particle/single-cell analysis, and probe laser ablation mapping files for unique regions of interest.

47 OTHER INSTRUMENTATION↗

Effect of hydrogen isotope on plasma impedance and thermal pinching induced by single aerosol droplets injected into an inductively coupled plasma

The mass of the hydrogen isotope in micrometer-sized aqueous droplets introduced into an ICP has been found to affect the degree of resulting plasma perturbation. Studied plasma perturbations include local plasma cooling, plasma shrinkage due to thermal pinching, and changes in plasma impedance. The local cooling effect caused by a vaporizing aerosol droplet was found to be similar between H 2 O and D 2 O. This finding is likely a result of the similar heat capacities and vaporization rates of H 2 O and D 2 O droplets and of the comparable thermal conductivities and dissociation kinetics of H 2 O and D 2 O vapor. In contrast, a clear isotope effect was observed for plasma shrinkage and impedance change, with H 2 O causing a considerably stronger effect. Plasma shrinkage, gauged by the reduction in Ar emission at the edge of the plasma, was detected at all observation heights within the load-coil region, with D 2 O droplets causing as much as 30% less of an effect than H 2 O. Likewise, D 2 O droplets induce significantly less change in plasma impedance than H 2 O droplets. Depending on experimental conditions and the probing method, changes in plasma impedance caused by monodisperse D 2 O droplets were only 52%–80% that of H 2 O. The lower influence on plasma shrinkage and impedance change for D 2 O droplets is believed to be related to the much lower thermal conductivity of atomic deuterium, around 70% that of atomic hydrogen (protium). The time required for the plasma impedance to return to its original steady-state value was comparatively long (~10 ms) and similar for H 2 O and D 2 O droplets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Thermodynamic insight into AnO 2 + bonding from ThH + /UH + reactions studied by inductively coupled plasma tandem mass spectrometry

The bonding mechanisms of actinides have been a focus of fundamental research over the past few decades. In the present study, reactions of the simplest actinide-containing species, ThH + and UH + , with O 2 and CO 2 are investigated by inductively coupled plasma tandem mass spectrometry. The reactions of ThH + and UH + with O 2 are efficient, and the reactions of ThH + and UH + with CO 2 display reduced reaction efficiencies. For both reactions involving CO 2 , ThO 2 + and UO 2 + are observed; however, there is a clear barrier to ThO 2 + formation whereas UO 2 + forms through an exothermic, barrierless process. The experimental observations and available thermodynamic information are used to predict the outcomes of reactions involving the later AnH + . The anticipated reaction enthalpies for Pa–Am display a clear correlation with the promotion energy of An + to a 6d 2 electronic configuration, E p (6d 2 ), although a shift in the slope of the correlation of reaction enthalpies and E p (6d 2 ) suggests that there is likely a change in bonding mechanism that starts with Np + . Similar shifts have also been noted in previous studies. Beginning with Np + , the 6d orbitals become less accessible than they are for the earlier An + as measured by E p (6d 2 ), and this accessibility of the 6d orbitals may drive actinide bonding.

5f orbitals↗

Determining P, S, Br, and I content in uranium by triple quadrupole inductively coupled plasma mass spectrometry

The trace impurities of a uranium ore concentrate (UOC) can be examined to determine mine source, methods of production, and quality. This study presents a method to determine the concentration of halides and main group elements, specifically P, S, Br and I, utilizing triple quadrupole inductively coupled plasma–mass spectrometry. These analytes were measured in a uranium matrix to simulate a UOC sample. The concentrations determined with this method showed agreement with known values. Solutions with and without uranium were compared. A UOC certified reference material, CUP-2, was analyzed to further demonstrate the effectiveness of the method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Quantifying Phospholipids in Organic Samples Using a Hydrophilic Interaction Liquid Chromatography–Inductively Coupled Plasma High-Resolution Mass Spectrometry (HILIC-ICP-HRMS) Method

Here, in this study, a novel method using hydrophilic interaction liquid chromatography (HILIC) coupled with inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) was introduced for the quantification of phospholipids in oil samples. The method employed a bridged ethyl hybrid (BEH) stationary phase HILIC column with a tetrahydrofuran (THF)/water mobile phase, enhancing the solubility and detection of phospholipids. During the study, a gradient/matrix effect on ICP-HRMS sensitivity was observed and successfully compensated for experimentally, ensuring reliable quantification results. This approach has proven effective for a wide range of different oil samples including vegetable oils, animal fats, and phospholipid supplements. Notably, this method allowed the direct quantification of phospholipids in oil samples, bypassing the need for prior sample preparation methods, such as solid phase extraction (SPE), thereby streamlining the analytical process. The precision, accuracy, and reduced need for extensive sample preparation offered by this method mark a significant advancement in lipids analysis. Its robustness and broad applicability have substantial implications for industries such as food and renewable energy production, where both efficient and accurate lipid identification and quantification are crucial.

09 BIOMASS FUELS↗

A preliminary investigation into the feasibility of laser ablation U–Pb isotope ratio measurement via all‐faraday cup detection with 10 11 ‐ and 10 13 ‐Ω amplifiers on the Neoma multicollector‐inductively coupled plasma‐mass spectrometer

Rationale Signal detection for uranium–lead (U–Pb) dating of zircon is typically performed via ion counters. Here, we develop a preliminary understanding of the strengths and limitations of faraday‐cup‐based detection. Methods A suite of zircon reference materials and the NIST‐610 glass were sampled using laser ablation followed by U–Pb isotope ratio measurement on a Neoma multicollector‐inductively coupled plasma‐mass spectrometer. Results We were able to produce geologically accurate 207 Pb/ 206 Pb, 206 Pb/ 238 U, and 207 Pb/ 235 U ratios for the NIST‐610 glass and the zircon standards, with ages ranging from ~2.5 Ga to ~337 Ma (TanBrown A, Oracle, 91550, Mud Tank, Temora, and Plešovice). Two of the younger zircon standards examined (94‐35, ~55.6 Ma, and Fish Canyon, 28.6 Ma) yielded accurate 206 Pb/ 238 U but not 207 Pb/ 235 U or 207 Pb/ 206 Pb ratios, whereas the youngest zircon standard (Penglai, ~4.4 Ma) failed for all three ratios of interest. The accuracy and precision of the all‐faraday method are directly tied to signal intensity, with reliable data capable of being produced even when both isotopes in a ratio have signals below ~0.001 V (equivalent to ~62 500 cps on an ion counter). Conclusion The all‐faraday cup multicollection method provides sufficient sensitivity to obtain geologically meaningful U–Pb data, with possible advantages being that laser pit depth‐dependent changes in the observed interelemental fractionation behavior may be easier to correct using a static collector configuration compared to when the ion beam is swept across a single detector while also removing the need for an interdetector‐type calibration. Further work is needed to refine the all‐faraday cup method (e.g., application of background subtraction and common Pb corrections, outlier removal, and interelement as well as down‐hole fractionation corrections), but our initial results demonstrate that the faraday detector method has sufficient sensitivity to warrant further study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phosphorus speciation analysis of fatty-acid-based feedstocks and fast pyrolysis biocrudes via gel permeation chromatography inductively coupled plasma high-resolution mass spectrometry

Renewable feedstocks, such as lignocelulosic fast pyrolysis oils and both vegetable oil and animal fats, are becoming a viable alternative to petroleum for producing high-quality renewable transportation fuels. However, the presence of phosphorus-containing compounds, mainly from phospholipids, in these renewable feedstocks is known to poison and deactivate hydrotreating catalysts during fuel production. In this work, gel permeation chromatography (GPC) combined with inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) was used to analyze feedstocks including unprocessed soybean oil, animal fat, and pyrolysis oils from red oak and milorganite to identify phosphorus species. The results have shown the presence of a wide range of different phosphorous compounds among all the samples analysed in this work. The GPC-ICP-HRMS analyses of a vegetable oil and two animal fats have shown different fingerprints based on the molecular weight of each of the samples, highlighting the structural differences among their corresponding phosphorus-containing compounds. While the presence of low-molecular-weight species, such as phospholipids, was expected, several high-molecular-weight species (MW > 10 000 Da) have been found, suggesting that high-molecular-weight micelles or liposomes might have been formed due to the high concentration of phospholipids in these samples. Results obtained through the hydroxylation of a mix of phospholipids (asolectin) and its posterior GPC-ICP-HRMS agree with this hypothesis. With respect to the lignocellulosic catalytic fast pyrolysis oil samples, the GPC-ICP-HRMS results obtained suggest that either aggregation or polymerization reactions might have occurred during the pyrolysis process, yielding phosphorus-containing compounds with an approximate molecular weight above 91 000 kDa. In addition, an aggregation phenomenom has been observed for those phosphorus species present within the fast pyrolysis oils after being stored for 3 months, especially for those pyrolysis oils contaning pre-processed feedstocks, such as milorganite.

09 BIOMASS FUELS↗

Simultaneous Determination of Halogens and Metals in Waste Plastic Pyrolysis Oil by Inductively Coupled Plasma Mass Spectrometry

A major barrier to integrating pyrolysis-derived oil into conventional refinery technology is the presence of impurities, particularly halogens and metals, that can deactivate catalysts. This study presents a novel, cost-effective approach for the simultaneous analysis of a subset of halogens, metals, nonmetals, and metalloids in complex, industrially relevant distilled pyrolysis oil samples, this was previously achievable only through multiple techniques. Excellent results were obtained using a widely accessible inductively coupled plasma mass spectrometry (ICP-MS) method with helium gas mode and standard laboratory consumables, enabling high-throughput analysis and efficient evaluation of adsorbent performance. Sample preparation is straightforward, requiring only dilution in a compatible matrix, and provides accurate and precise quantification, with 75%–137% spike recovery for Be, Ti, V, Cr, Fe, Ni, Co, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, and 62%–65% spike recovery for Cl and 109%–133% spike recovery for Br. Additionally, an enhanced version of the method using ICP-MS/MS and hydrogen gas is described, which has higher accuracy with 69%–112% spike recovery for Be, B, Ti, V, Fe, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, with 85%–102% spike recovery for Cl and 63%–93% spike recovery for Br. Helium mode detection limits for industrially relevant elements (V, Fe, Ni, Cu, As, and Pb) are less than 1.7 µg/kg, and less than 0.2 mg/kg for Br and Cl. Furthermore, this methodology facilitates rapid systematic evaluation of adsorption capacities of materials under time-on-stream conditions and supports robust comparisons across diverse operating environments.

Lazarcik, James [University of Wisconsin-Madison, ↗

An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices

Accurate actinide measurements are critical within the field of nuclear science. Traditional methods for actinide quantification require time-consuming sample processing prior to analysis. There is a need for rapid analytical techniques that still maintain a high degree of accuracy. In this work, actinide reactivity was assessed for multiple oxygen-containing reaction gases using quadrupole inductively coupled plasma tandem mass spectrometry (Q-ICP-MS/MS) to evaluate actinide analysis in complex sample matrices without analyte-matrix separation. A novel method was developed to measure 241 Am/ 241 Pu in complex sample matrices using O 2 /He reaction gas with no matrix removal or analyte pre-concentration. This inline method reduces matrix-derived polyatomic interferences that complicate traditional ICP-MS analyses by mass-shifting to 241 Am 16 O + and 241 Pu 16 O 2 + , allowing Am and Pu to be mass separated for simultaneous analysis. While mass shifting is efficient, a small portion of Am + (<1.3%) and Pu + (<1.4%) react to from AmO 2 + and PuO + , respectively. Therefore, a mass balance approach was used, in combination with reactivity determined from 242 Pu and 243 Am standard solutions, to correct for residual 241 PuO + and 241 AmO 2 + . The method was validated by measuring 241 Am/ 241 Pu in Pu isotope standards CRM-136 and CRM-137 (separated in March/April 1970 and February 2022, respectively) in both neat solutions and complex matrices containing diluted soil (NIST SRM 2711a, >1000 µg·g -1 ). Method detection limits of 15.9 and 9.6 fg·g -1 were determined for 241 Am and 241 Pu, respectively, and 241 Am/ 241 Pu ratios were measured with accuracies within <3.5%. In conclusion, this work presents the first direct analysis of 241 Am/ 241 Pu in unseparated complex matrices, advancing capabilities for rapid actinide measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid and automated separation of uranium ore concentrates for trace element analysis by inductively coupled plasma – optical emission spectroscopy/triple quadrupole mass spectrometry

The present study documents an automated approach to performing elemental analysis on a large group uranium ore concentrate (UOC) samples. In this work, 17 UOC samples, 2 quality control samples, and 26 process blanks were purified sequentially through a single 500 μL Uranium and TEtra Valent Actinides (UTEVA®) column. For each sample, the trace elemental impurities were separated from its dissolved uranium matrix on the UTEVA column and collected for analysis by inductively coupled plasma – optical emission spectroscopy / triple quadrupole mass spectrometry (ICP-OES/TQMS). The UTEVA column was subsequently regenerated prior to separation of the following sample. The column was efficiently regenerated, for each UOC, even after processing ~50 mg of uranium, cumulatively. The validity of the method was established by determining the trace impurities of two quality control uranium reference samples (CRM 124–1 and CUP-2). The current trace element measurements from the 17 UOC samples were compared to previously reported values from an interlaboratory comparison exercise, when available. The methodology employed here produces trace elemental analysis with excellent correlation to the previously reported data for many of the elements / samples, particularly when viewed through the context of existing geochemical comparisons tools (e.g. chondrite normalized variation plots).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elemental Analysis of Bio-Oils by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). Laboratory Analytical Procedure (LAP), Issue Date: May 13, 2022

Concentrations of inorganic elements is a key quality metric for bio-oils as certain elements impact upgrading processes and product quality. Unless reduced or removed during production and processing, alkali and alkaline metals native to lignocellulosic biomass can carry over into bio-oils contributing to ash content and degraded catalyst performance during upgrading to hydrocarbon fuels or chemical products. Non-metallic elements such as sulfur and phosphorus can also negatively impact upgrading catalysts and product quality. Inductively coupled plasma optical emission spectroscopy (ICP-OES) can be used to measure inorganic elements of interest in bio-oils. This procedure covers the preparation and analysis of fast pyrolysis (FP) and catalytic fast pyrolysis (CFP) bio-oils. The concentrations of these elements can indicate potential bio-oil quality from the perspective of deoxygenation processes. The implications of elemental composition will depend on process parameters such as upgrading catalyst sensitivities. This Laboratory Analytical Procedure (LAP) covers two methods for quantification of inorganic elements by ICP-OES: Procedure A uses microwave assisted digestion with concentrated nitric acid, and Procedure B is an organic ICP-OES method utilizing a diglyme solvent.

09 BIOMASS FUELS↗

The balance of orbital overlap and orbital energy in the activation of methane by actinide cations: insights from inductively coupled plasma tandem mass spectrometry

The actinides present a unique challenge to chemical theory. The classical view of covalent bonding is driven by the extent of spatial overlap of valence orbitals. Modern theory has expanded assessments of covalency to include considerations of orbital energy degeneracy to assess orbital energy mixing between metal and ligand valence orbitals. Actinide–ligand (An–L) bonding has more recently been described as a balance between orbital overlap and orbital energy mixing, where 5f and L valence orbital overlap decreases while energy mixing between An 5f and L valence orbitals increases across the series. To test these existing views, we employed inductively coupled plasma tandem mass spectrometry to examine the kinetic energy dependences of reactions of actinide cations, Th + –Am + , with methane. Further, this is the first experimental report of the energy dependences of methane activation reactions involving the cations of Pa, Np, Pu, and Am and the first experimental determination of transuranic An + –D, An + –CD 2 , An + –CD 3 , and An + –CD bond dissociation energies. The correlation of the measured An + –CD 2 bond energies with E p (6d 2 ) indicates that An + 6d orbitals are the dominant contributors in the An + –CD 2 bonds. Close examination of the relative reactivities of An + offers additional support that the balance of classical and modern views of molecular bonding may lie between Np + and Pu + and that the increased reactivity of Th + –Np + may be attributed to the increased spatial extension of the 5f orbitals whereas covalent An + bond formation may be more driven by the decreasing energies of the 5f orbitals across the actinide series.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗