Search NASA⌕ Search

SEARCH · Search NASA

Results for “Industrial Assessment Center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Industrial Assessment Center Technical Field Manager

The work to be performed involves managing Industrial Assessment Centers through a portfolio of activities. The core activities to be performed are in the general areas of; quality assurance of IAC operations, enhancement of the student IAC experience, program development for improving assessments and implementing smart manufacturing projects, program outreach to carry assessment successes beyond the program, and program integration with other DOE/manufacturing assistance programs. The IAC Technical Field Management Organization (FMO) works in close collaboration with DOE and provides technical management for the IAC program working under policy guidelines established by DOE.

42 ENGINEERING↗

Industrial Assessment Center – integration of education and practice. Final progress report

The goal of the DOE’s Industrial Assessment Center (IAC) program is twofold: first, to help US manufacturing competitiveness by providing assessments and recommendations for small and medium-sized enterprises (SMEs) on energy efficiency, productivity, sustainability and competitiveness – including measuring the impacts of these recommendations on reducing greenhouse gas emissions; and second, to address a growing shortage of engineering professionals with applied energy and manufacturing-related skills by training a diverse cross-section of engineering students through hands-on involvement in these assessments. IUPUI has an IAC, which was established in 2011, in the Department of Mechanical and Energy Engineering, Purdue School of Engineering and Technology, IUPUI. The IAC has won the awards twice. We have built the center that has the expertise and infrastructure for quality energy assessments to manufactures and commercial building owners and aligned our current research and teaching activities to the DOE’ training mission with programs to train the next generation of industrial energy efficiency experts, with theory and hands-on experience in conducting energy assessment for small and median manufacturing enterprises. We have made recommendations that have the potential to save about $20M annually. We also initiated research projects to meet DOE priorities, specifically in the areas of smart manufacturing and cybersecurity. On the energy assessment side, the Center has provided energy assessments to 144 qualified companies, primarily located in Indiana. On the training side, the center has trained students in various programs, such as the department’s Bachelor of Science (BS) programs in Mechanical Engineering (ME) and BS in Energy Engineering (EEN), both are ABET accredited engineering programs, as well as a graduate level Energy Management and Assessment certificate program. At the present, the center has trained 95 students, 43 or them received the DOE issued certificates. Research projects were developed within the center to advance energy efficiency related technologies, which provided excellent opportunities for our trainees. The center has also been building a professional network with utilities, Manufacturing Extension Partnership (MEP), government agencies, and manufacturing companies, to increase our client base and promote collaborations. The center received the 2019 Center of Excellence of the Year Award and three students received the “Outstanding Achievement in Energy Engineering by an IAC Student” awards in the past five years.

42 ENGINEERING↗

UF Industrial Assessment Center - Budget Periods 2017-2021. Final Report

This report summarizes the work performed at the University of Florida’s Industrial Assessment Center (UF-IAC) during the five budget periods (BPs) in the years 2017 through 2021 under DOE Award No. DE-EE0007707. The objective of the work is to perform industrial assessments to small- and medium-sized manufacturing facilities in the State of Florida and to train students in industrial energy management and in performing industrial assessments. Specific details about the activities of the UF-IAC (referred to as the Center) during that time can be found in the 20 quarterly reports that were submitted throughout the duration of the contract. The project start and end dates are September 1, 2016 and August 31, 2021, respectively. The project was granted a six-month no-cost extension till February 28, 2022, to accommodate unexpected delays due to the COVID-19 pandemic. This project was performed by the University of Florida (PI: Dr. SA Sherif). The scope of work includes six milestone whose description and outcomes are listed in the Statement of Project Objectives (SOPO).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industrial Assessment Center Program. Final Progress Report

In the past five years, University of Wisconsin-Milwaukee (UWM) Industrial Assessment Center (IAC) has established a high reputation in Wisconsin through the dedicated, continuous, and extraordinary efforts made by the WM IAC team. Our center has developed a broad range of partners in Wisconsin to promote and support our IAC program. We have established a partnership with We Energies, the primary utility company in Wisconsin, to provide high-quality energy assessments for their customers. We also acquired comprehensive support from Focus on Energy, the state energy agency, to promote the IAC among their state-wide networks. We have partnered with Wisconsin State Government agencies, the Office of Energy Innovation, and the Office of Sustainability and Clean Energy. We have been working on our best to make UWM IAC an outstanding program in Wisconsin. WM-IAC attracted the US Administration, and US Vice President, Kamala Harris, visited UWM IAC in May 2021 and conducted a Round Table discussion. In addition, in March 2021, one of the WM IAC student members was invited to the Round Table on supporting America's Manufacturing, and Industrial Workers arranged by the US Secretary of Energy, Jennifer Granholm, on March 8, 2021.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industrial Assessment Center for Underserved Delmarva Area

This report summarizes the work done by the Industrial and Training Assessment Center at the University of Delaware under the award number DE-EE0008796. The 38 audits performed during this period (DL0178 – DL0214) happened from October 2019 to October 2022. The facilities audited belong to a total of 27 industry types, according to the Standard Industry Classification (SIC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industrial Assessment Center for Energy Efficiency, Smart Manufacturing and Cyber Security of Illinois and Northwestern Indiana Small and Medium Sized Manufacturing Companies and Water Facilities (Final Technical Report)

The University of Illinois Chicago (UIC) established and implemented a U.S. Department of Energy (DOE) sponsored Industrial Assessment Center (IAC) from September 1, 2016 through December 31, 2021. The established UIC IAC focused on providing 1) technical assistance to small and medium-sized enterprises (SMEs) and water and wastewater facilities in Illinois and northwestern Indiana and 2) education and training university students developing the future energy workforce. The technical assessments incorporated energy efficiency, increasing productivity via smart manufacturing, energy management systems, enhancing on-site cyber security practices, and the promotion of DOE best practices and tools. The educational training enabled UIC faculty and staff to provide classroom education, exposure to industry research, multiple targeted training sessions, real world experience with industry professionals, and live training to implement professional grade audits and recommendations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Oklahoma State University – Industrial Assessment Center (Final Report)

Our first primary objective is to provide industrial assessments to clients in Oklahoma, Arkansas, Kansas, and north and northwest Texas, including the Texas Panhandle (about 10% of the state of Texas). This geographical region extends about 400 miles north and south and about 600 miles east and west. In addition, the partnership links two universities, Oklahoma State University (OSU) and Wichita State University (WSU) within our region together in a significant collaboration focused on improving our region’s industrial competitiveness. Our second primary objective is to produce competent, motivated energy engineers. Student training will be a combination of classroom work, individual mentoring, and on-the-job training. The focus will be on energy conservation technologies, in conjunction with increased productivity, the economics of the same, and client relationships including client recruiting, on-site assessment, reporting, and client-related communications. Finally, we will work to provide resources and expertise to complement the first two primary objectives. The effectiveness and efficiency of our IAC will be measured, internally, by four broad criteria: (1) client benefits, (2) student development and acceptance after graduation, (3) regional/national contribution to lowering energy use and reducing pollutants, and (4) compliance with DOE/FM requirements. Client-related benefits include client contacts, timeliness of assessments and reports, the value of recommendations provided, and the value of recommendations implemented. Student development includes many students trained and the level of training provided in energy, waste, and productivity-related technologies as well as teamwork and communication skills. The contribution to lower national energy use and waste production is a natural outcome of the program. Compliance with DOE/FM requirements includes timeliness of reports, participation in Best Practices activities, contributions to EERE goals and objectives, and other requirements as communicated to the IAC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Midwest Industrial Assessment Center (Final Technical Report)

The Midwest IAC’s prime center was at the University of Missouri (MU) and the satellite center was at Wichita State University, Kansas. During the 5-year period we conducted at least 96 energy assessments, with recommended energy cost savings of $10.3 million of which $6.5 million was implemented savings. The implemented energy savings were 0.63 Terra BTU and CO2 emissions reduction was 400,000 tons. Thirty-five students completed requirements for a certificate of completion from DOE. IAC students received training in cybersecurity basics and application to manufacturing, fundamentals of energy efficiency, ISO50001, smart manufacturing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Extension Industrial Assessment Center in Eastern Great Lakes Region

The extension IAC at CWRU is funded for 3 years to conduct 10 assessments of small and medium-sized manufacturing facilities each year in Eastern Great Lakes region. Total 30 assessments was proposed in the SOPO but due to the Covid-19 pandemic, the IAC program was suspended for 1.5 years. A total of 20 assessments was contracted to the extension IAC at CWRU which have been successfully accomplished. In the proposal, we proposed to train 18 students in the extension IAC program, and actually we selected and trained 19 students even though the IAC project was suspended during half of its project period.

42 ENGINEERING↗

NCSU Industrial Assessment Center

Renewable energy technologies are becoming more attractive and gaining more attention as the world becomes increasingly aware of the negative impacts of global warming and greenhouse gas (GHG) emissions. Two such emerging technologies are geothermal heat pumps (GHP) and solar thermal heating which can be used for heating and cooling of buildings. GHP systems are a well-studied technology that have been proven to be more efficient than traditional air-source heat pumps for space conditioning of buildings. Solar thermal heating has become more common as a way to heat domestic hot water (DHW) in homes, but the two technologies are not often combined. This study presents the findings of combining an open-loop GHP with 100 ft2 of flat plate solar thermal panels and a 5,655-gallon sensible water storage tank for space heating and DHW heating needs of a residential home in Bozeman, MT, USA. The goal of this system was to use energy from the solar panels and storage tank first to decrease pumping energy from the GHP well. The open loop system was designed to be a backup system to the solar thermal panels and sensible storage tank. An actual home was modeled to determine potential energy and cost savings of such a system compared to a traditional propane boiler. Then, a case study was performed on the installed system from January to June 2021. Results obtained from April 2nd to June 5th, 2021 indicated that the combination system supplied all necessary heat, and that heat was supplied from the thermal storage tank 55% of the time. This represents a savings of 330 kWh of energy and $36 compared to operating just the open loop geothermal system. From April 2nd to June 5th the combination system consumed a total of 2,510 kWh of energy and cost $274 to operate. Based on data obtained, there is significant potential for energy savings compared to a propane boiler, however only small potential for cost savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Establishment of an Industrial Assessment Center (IAC) site at Arizona State University (ASU)

In this document we report the overall accomplishments of the IAC site at ASU. The report is organized in three different areas: conduct industrial assessments; provide training, research, and educational opportunities to IAC students; and other activities. The report includes those assessments made between September 2016 to August 2021.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Collaborative Industrial Assessment Center (IAC) for Expanded Outreach within the Southeast

This GA-FL IAC had impacts on workforce development and economic impact for regional small- and medium-sized enterprises. Qualified faculty and campus staff educated and trained cohorts of students regarding state-of-the-art industrial assessments. Students gained hands-on experiences in learning about manufacturing processes, energy systems, developing assessment recommendations/calculations, and client interaction. These skills were complemented by the incorporation of IAC themes into some course curricula. As far as economic impact, the center conducted 66 assessments over 5 years primarily in Georgia and Florida. These represented hundreds of thousands of dollars in potential annual resource savings to the clients and region.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industrial Assessment Center Program Final Progress Report

This final progress report details the work completed between Fiscal Years 2017 and 2021, including a no-cost extension partially through FY2022. Dr. Bryan Rasmussen served as the center director (2017-2022), with James Eggebrecht (2017-2022) and Heather Lewis (2021-2022) as Assistant Directors. The results in this report were compiled by Dr. Rasmussen from available records, and are correct to the best of our knowledge. The following should only be considered a partial listing of center activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Analysis: Ways to Save Energy and Reduce the Emissions in Wastewater Treatment Plants

The key of this study is to explore the primary energy consumers in wastewater treatment plants, which is considered as one of the major energy consumers, and introduces the best solution to save energy and reduce emissions in these facilities. This study is based on the energy assessment and analyses of eleven wastewater treatment plants. Through the investigation, it was found that plants can save up to 44,158 MWh of the energy consumption which is 47% from the total electricity consumption with a 17% reduction in the total utility bills and that about 2.5 million dollars cost savings after reviewing the currently facilitated energy system. Additionally, an average of five years' payback period resulted in most energy-saving recommendations. A vast potential of greenhouse gas emissions can be reduced with a total range reduction between 13 to 35 million kg of CO 2 based on the speed reduction percentage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficiency for the growing South Carolina manufacturing industries. Final Report

The overall goals of the proposed project were to establish a DOE Industrial Assessment Center with Clemson University as the main center and to cement the Clemson IAC as the "go to" resource for energy efficiency expertise and assistance to manufacturing businesses in the state of South Carolina. The Clemson IAC included a satellite support center through partnership with the SCE&G Energy Innovation Center at the Clemson University Restoration Institute (CURI) in North Charleston, SC. The Clemson IAC was the first IAC based in the state with the goal to serve the entire state. The Clemson IAC provided SMEs with no-cost energy assessments, trained the next generation of energy-savvy engineers, and provided outreach to non-participating SMEs. Project objectives were structured into five 12-month Budget Periods. In the first Budget Period, the primary objective was to establish methods and materials for Clemson IAC assessments, training, and outreach. In the remaining Budget Periods, the primary objectives were to perform assessments, train students, and pursue outreach to hard-to-reach SMEs that did not participate in energy assessments. Expected outcomes in the first Budget Period included the development of standard procedures for performing energy assessments, including data acquisition, processing, and communication both within the team and in assessment reports prepared for SMEs. Outcomes related to student training in the first Budget Period included detailed curriculum and internship plans for students pursuing the DOE IAC Certificate and energy-related Clemson University certificates. Outcomes in the first Budget Period also included the development of outreach materials and plans for outreach events. In Budget Periods 2 through 5, major expected outcomes are trained students and completed energy assessments and reports for SMEs. Decision points and Go-No Go criteria for the end of each Budget Period, presented in more detail below, are based on the number of students in training and the number of energy assessments performed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The current state of the industrial energy assessment and its impacts on the manufacturing industry

Energy-intensive manufacturing is the greatest contributor to the U.S. industrial energy consumption today. Globally, manufacturing facilities are being directed to reduce their energy consumption to prepare for a sustainable future. Industrial energy assessment plays a crucial role in helping facilities meet their energy efficiency goals by encouraging the implementation of cost-effective, energy-saving recommendations to the existing equipment and processes. Across the world, programs such as the U.S. Department of Energy (DOE) sponsored Industrial Assessment Centers (IACs) (operational across several states in the U.S. for over four decades), are transforming the future of industrial energy consumption by offering free industrial energy assessments to qualifying facilities. In this review paper, the industrial energy assessment approach and practices are comprehensively reviewed with focus on popular recommendations, procedures, and the current practices of the industrial energy assessment program. Specifically, opportunities for improvement in the most energy-intensive manufacturing processes are examined, concentrating on the energy savings and other non-energy benefits of each of these measures, such as cost savings and emissions reduction. Furthermore, this paper also reviews how these energy-saving opportunities are procedurally evaluated and how factors, such as level and cost of assessments, and assessment metrics, are currently defining industrial energy assessment. In final considerations, existing research on energy management, decarbonization through electrification, and renewable energy in industry is reviewed and discussed, and how these advancements will shape the future of industrial energy assessment is addressed through forward-looking lenses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗