Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrared light”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Instruments for Reading Direct-Marked Data-Matrix Symbols

Improved optoelectronic instruments (specially configured digital cameras) for reading direct-marked data-matrix symbols on the surfaces of optically reflective objects (including specularly reflective ones) are undergoing development. Data-matrix symbols are two-dimensional binary patterns that are used, like common bar codes, for automated identification of objects. The first data-matrix symbols were checkerboard-like patterns of black-and-white rectangles, typically existing in the forms of paint, ink, or detachable labels. The major advantage of direct marking (the marks are more durable than are painted or printed symbols or detachable labels) is offset by a major disadvantage (the marks generated by some marking methods do not provide sufficient contrast to be readable by optoelectronic instruments designed to read black-and-white data-matrix symbols). Heretofore, elaborate lighting, lensing, and software schemes have been tried in efforts to solve the contrast problem in direct-mark matrix- symbol readers. In comparison with prior readers based on those schemes, the readers now undergoing development are expected to be more effective while costing less. All of the prior direct-mark matrix-symbol readers are designed to be aimed perpendicularly to marked target surfaces, and they tolerate very little angular offset. However, the reader now undergoing development not only tolerates angular offset but depends on angular offset as a means of obtaining the needed contrast, as described below. The prototype reader (see Figure 1) includes an electronic camera in the form of a charge-coupled-device (CCD) image detector equipped with a telecentric lens. It also includes a source of collimated visible light and a source of collimated infrared light for illuminating a target. The visible and infrared illumination complement each other: the visible illumination is more useful for aiming the reader toward a target, while the infrared illumination is more useful for reading symbols on highly reflective surfaces. By use of beam splitters, the visible and infrared collimated lights are introduced along the optical path of the telecentric lens, so that the target is illuminated and viewed from the same direction.

Schramm, Harry F.↗

Near-infrared observations of a new molecular feature in IRC + 10216

This letter presents a spectrum of IRC + 10216 in the 3000-4400-kayser region at 9-kayser resolution. A molecular feature at 3400-3600 kaysers has been detected which is attributed to an unspecified N-H bonded molecule; the feature appears to be variable in phase with the infrared light curve. Evidence is given for temperature variations of the emitting dust shell in phase with the infrared light curve. The results suggest that the variability of the molecular feature is due to reversible dissociation of the responsible molecule, which could occur at the higher temperatures accompanying the maxima of the light curve.

Krassner, J.↗

Infrared variability of SS 433

New JHKLM photometry of SS 433 showing short time scale variabilities is reported for the period of 1983 July 16-22 UT. The entire body of infrared data included in this paper, Giles et al. (1980), and Catchpole et al. (1981), is examined with reference to periods of 164 days and 13.08 days. Comparison of the infrared light curves with the optical light curves of Leibowitz et al. (1984) makes it possible to conclude, within the context of an accretion disk model, that the majority of the infrared flux in the SS 433 system comes from the disk, and that the hot spot responsible for the 'hump' in the visual and infrared light curves has a color similar to the average of the disk. A two-dimensional Fourier analysis of the infrared data suggests that the brightness maximum occurs when, seen from the compact star, the noncompact companion passes through a fixed elongation relative to the disk line of nodes with the orbital plane, if the precession is prograde.

Kodaira, K.↗

Strength of mineral absorption features in the transmitted component of near-infrared reflected light - First results from RELAB

Bidirectional reflectance measurements are the only type of reflectance data available to the remote observer. For compositional interpretations, data are desired not only for identification of possible mineral components but also for modal abundance. The latter requires detailed information about the strength of absorption features. Using a new laboratory facility, the RELAB, laboratory data in the near infrared are presented that document effects of particle size, mineral mixtures, and viewing geometry for selected materials with well-developed absorption bands. The commonly observed increase in reflectance with decrease in particle size is also observed for absorption bands as well as a related decrease in absorption strength. For small particles in parts of the spectrum of maximum reflectance, however, a minor decrease in reflectance with a decrese in particle size is sometimes observed. Small particles dominate the observed characteristics of particulate surfaces, which contain a range of particle sizes. The mean optical path length (transmission through particles) of reflected radiation measured for a variety of particle sizes has an apparent upper limit of about 2 mm for particles of less than 250 microns. The typical number of particles involved in the optical path is less than 50.

Pieters, C. M.↗

First-Generation Jet Propulsion Laboratory "Hockey-Puck" Free-Flying Magnetometers for Distributed In-Situ Multiprobe Measurement of Current Density Filamentation in the Northern Auroral Zone: Enstrophy Mission

The sub-orbital rocket mission was a collaborative project between the University of New Hampshire, Cornell University, and the Jet Propulsion Laboratory (JPL) to study filamentation phenomena in the northern Auroral zone. The Enstrophy mission test flies the JPL Free-Flying Magnetometer (FFM) concept. The FFM technology development task has been funded by NASA develop miniaturized, low-power, integrated "sensorcrafts". JPL's role was to design, integrate, test, and deliver four FFMs for deployment from the sounding rocket, allowing a unique determination of curl-B. This provides a direct measurement of magnetic-field-aligned current density along the rocket trajectory. A miniaturized three-axis fluxgate magnetometer was integrated with a 4-channel 22-bit sigma-delta Analog to Digital Converter (ADC), four temperature sensors, digital control electronics, seven (Li-SOCl2) batteries, two (4 deg x 170 deg field of view) sun-sensors, a fan-shaped-beam laser diode beacon, a (16 MHz) stable Temperature Compensated Crystal Oscillator (TCXO) clock, Radio Frequency (RF) communication subsystem, and an antenna for approximately 15 minutes of operation where data was collected continuously and transmitted in three (3) bursts (approximately 26 seconds each) to ground station antennas at Poker Flat, Alaska. FFMs were stowed within two trays onboard the rocket during the rocket launch and were released simultaneously using the spinning action of the rocket at approximately 300 km altitude (approximately 100 sec. into the flight). FFMs were deployed with spin rate of approximately 17 Hz and approximately 3 m/sec linear velocity with respect to the rocket. For testing purposes while the rocket was in the launch pad and during flight prior to release of FFMs from the rocket, commands (such as "power on", "test", "flight", "power off', and clock "Reset" signal) were transmitted via a infrared Light Emitting Diode to an infrared detector in the FFM. Special attention was paid to low magnetic signature electronic design and choice of materials in packaging. The miniaturized fluxgate magnetometers had a range of 1-60000 nT with 0.1% full-scale linearity. The frequency range of interest for magnetic measurement was 10 mHz - 50 Hz. Digital data from the magnetometer's three axes were placed in a 4MB Static Random Access Memory (SRAM) in data packages (frames) formatted together with time tags and frame ID. After a specified time was elapsed, the data were Viterbi encoded and transmitted at a rate of 100 kbps (BPSK). Each of the four FFMs transmitted at different frequency. These carrier frequencies were in the range of 2200-2300 MHz. The antenna was a single patch on a high dielectric constant substrate covering one end-plate of the hockey-puck-sized unit. The local clocks aboard the FFMs were reset at the start of the mission and stayed synchronized within 3 msec during the mission. Position of each FFM with respect to the rocket is calculated by the knowledge of its release velocity (measured at exit point of the FFM launcher tract) providing an accuracy of 1 m over the maximum range of 3 km. Spatial and temporal nature of observants can be separated to within 3 m in space or 3 msec time interval.

Javadi, H.↗

Benchtop Detection of Proteins

A process, and a benchtop-scale apparatus for implementing the process, have been developed to detect proteins associated with specific microbes in water. The process and apparatus may also be useful for detection of proteins in other, more complex liquids. There may be numerous potential applications, including monitoring lakes and streams for contamination, testing of blood and other bodily fluids in medical laboratories, and testing for microbial contamination of liquids in restaurants and industrial food-processing facilities. A sample can be prepared and analyzed by use of this process and apparatus within minutes, whereas an equivalent analysis performed by use of other processes and equipment can often take hours to days. The process begins with the conjugation of near-infrared-fluorescent dyes to antibodies that are specific to a particular protein. Initially, the research has focused on using near-infrared dyes to detect antigens or associated proteins in solution, which has proven successful vs. microbial cells, and streamlining the technique in use for surface protein detection on microbes would theoretically render similar results. However, it is noted that additional work is needed to transition protein-based techniques to microbial cell detection. Consequently, multiple such dye/antibody pairs could be prepared to enable detection of multiple selected microbial species, using a different dye for each species. When excited by near-infrared light of a suitable wavelength, each dye fluoresces at a unique longer wavelength that differs from those of the other dyes, enabling discrimination among the various species. In initial tests, the dye/antibody pairs are mixed into a solution suspected of containing the selected proteins, causing the binding of the dye/antibody pairs to such suspect proteins that may be present. The solution is then run through a microcentrifuge that includes a membrane that acts as a filter in that it retains the dye/antibody/protein complexes while allowing any remaining unbound dye/antibody pairs to flow away. The retained dye/antibody/protein complexes are transferred to a cuvette, wherein they are irradiated with light from a miniature near-infrared laser delivered via a fiber-optic cable. The resulting fluorescence from the dye(s) is measured by use of a miniature spectrometer, the output of which is digitized, then analyzed by laptop computer. The software running in the computer identifies the protein species by the wavelengths of their spectral peaks and determines the amounts of the proteins, and thus, one day, microbes of the various species from the intensities of the peaks. The abovementioned removal of the unbound dye/antibody pairs during centrifugation prevents false positive readings. The process proves successful in detecting proteins in solution and thus can now be employed for use in microbe detection.

Scardelletti, Maximilian C.↗

Delayed detonation models for normal and subluminous type Ia sueprnovae: Absolute brightness, light curves, and molecule formation

We compute optical and infrared light curves of the pulsating class of delayed detonation models for Type Ia supernovae (SN Ia's) using an elaborate treatment of the Local Thermodynamic Equilbrium (LTE) radiation transport, equation of state and ionization balance, expansion opacity including the cooling by CO, Co(+), and SiO, and a Monte Carlo gamma-ray deposition scheme. The models have an amount of Ni-56 in the range from approximately or equal to 0.1 solar mass up to 0.7 solar mass depending on the density at which the transition from a deflagration to a detonation occurs. Models with a large nickel production give light curves comparable to those of typical Type Ia supernovae. Subluminous supernovae can be explained by models with a low nickel production. Multiband light curves are presented in comparison with the normally bright event SN 1992bc and the subluminous events Sn 1991bg and SN 1992bo to establish the principle that the delayed detonation paradigm in Chandrasekhar mass models may give a common explosion mechanism accounting for both normal and subluminous SN Ia's. Secondary IR-maxima are formed in the models of normal SN Ia's as a photospheric effect if the photospheric radius continues to increase well after maximum light. Secondary maxima appear later and stronger in models with moderate expansion velocities and with radioactive material closer to the surface. Model light curves for subluminous SN Ia's tend to show only one 'late' IR-maximum. In some delayed detonation models shell-like envelopes form, which consist of unburned carbon and oxygen. The formation of molecules in these envelopes is addressed. If the model retains a C/O-envelope and is subluminous, strong vibration bands of CO may appear, typically several weeks past maximum light. CO should be very weak or absent in normal Sn Ia's.

Hoflich, P.↗

Photoelectronic Monitor of Motion Sickness

Instrument includes gallium arsenide light-emitting diode (LED) and silicon phototransistor with infrared filter, all cast in single plastic housing. Housing attached to subject's face with transparent doublesided adhesive tape. LED directs pulses of infrared light to skin, which reflects them to phototransistor. Phototransistor produces signal that is processed by external circuits to yield plot of infrared reflectance with time. External circuits temperature-compensated and respond only to pulsed component of detector output, rejecting those components caused by stray light. Circuits also extract blood-volume pulse amplitude and heart rate.

Oman, C. M.↗

The infrared echo of Type II supernovae with circumstellar dust shells. II - A probe into the presupernova evolution of the progenitor star

This paper studies the spectral appearance and evolution of the infrared light curve, also referred to as the infrared echo, of Type II supernovae embedded in carbon- or oxygen-rich circumstellar dust shells. The distinct spectral signature of the echo and its temporal evolution can be used to estimate the mass of the shell and identify the composition of the dust. Since the shell mass and dust composition are determined by the combined effect of stellar mass loss and the dredging of newly synthesized heavy elements to the stellar surface, observations of the infrared echo may provide useful clues to the presupernova evolution of the progenitor star.

Dwek, E.↗

Analytical study of the effects of clouds on the light produced by lightning

Researchers consider the scattering of visible and infrared light due to lightning by cubic, cylindrical and spherical clouds. The researchers extend to cloud physics the work by Twersky for single and multiple scattering of electromagnetic waves. They solve the interior problem separately to obtain the bulk parameters for the scatterer equivalent to the ensemble of spherical droplets. With the interior solution or the equivalent medium approach, the multiple scattering problem is reduced to that of a single scatterer in isolation. Hence, the computing methods of Wiscombe or Bohren specialized to Mie scattering with the possibility for absorption were used to generate numerical results in short computer time.

Phanord, Dieudonne D.↗

Type Ia supernovae: Pulsating delayed detonation models, IR light curves, and the formation of molecules

We computed optical and infrared light curves of the pulsating class of delayed detonation models for Type Ia supernovae (SNe Ia). It is demonstrated that observations of the IR light curves can be used to identify subluminous SNe Ia by testing whether secondary maxima occur in the IR. Our pulsating delayed detonation models are in agreement with current observations both for subluminous and normal bright SN Ia, namely SN1991bg, SN1992bo, and SN1992bc. Observations of molecular bands provide a test to distinguish whether strongly subluminous supernovae are a consequence of the pulsating mechanism occurring in a high-mass white dwarf (WD) or, alternatively, are formed by the helium detonation in a low-mass WD as was suggested by Woosley. In the latter case, no carbon is left after the explosion of low-mass WDs whereas a log of C/O-rich material is present in pulsating delayed detonation models.

Hoflich, Peter↗

The low state of AM Herculis - Observations from 0.12 to 10 microns

Observations of AM Her during a low state over a wavelength range from 0.12 to 10 microns are reported. These include IUE ultraviolet spectra, light curves at U, B, V, R, J, H, K, and magnitudes at L, M, and N. The UV observations reveal a nearly Rayleigh-Jeans continuum spectral distribution and broad Lyman-alpha absorption from a hot (effective temperature = 50,000 K) white dwarf. Of the strong emission lines present in the high state, only weak C IV (1550 A) and Mg II (2800 A) features remain. The optical light curves are markedly different from the high state, while the infrared light curves are similar in appearance to the high state. The infrared variations cannot be explained solely by the ellipsoidal variations of a secondary star which is heated by an accretion column. The 10 micron flux is less than the high state, but it is not possible to tell if the excess noted during the high state is still present. The large available wavelength range is used to constrain the relative contributions of the white dwarf, the red dwarf, and the accretion columns.

Szkody, P.↗

Fiat Lux, Let There Be Light!

Most of us think of light as helping us see things, but it is so much more important than that. Light is electromagnetic energy moving in waves through space, interacting with atoms and molecules as it goes. So are radio waves, microwaves, infrared light, ultraviolet, x-rays and gamma rays - all of them are electromagnetic energy, and the only real difference is the spacing between the wave crests. So light gives us communications with each other with radio and TV, and it gives us the ability to travel through the universe using telescopes and our imagination. But light also gives us access to scientific questions, such as: what holds the atoms and molecules together? How does the mysterious quantum mechanics work? And understanding all these, how can we build electronic devices for modern life? And if we are very ambitious, we build accelerators like the Large Hadron Collider, and particles collide and concentrate electromagnetic energy into tiny spaces, and according to Einstein's E equals mc squared, we turn energy into new particles to learn, perhaps what the universe was like when it was a tiny fraction of a second old.

telescopes↗

Solid-State Laser Source of Tunable Narrow-Bandwidth Ultraviolet Radiation

A solid-state laser source of tunable and narrow-bandwidth UV light is disclosed. The system relies on light from a diode laser that preferably generates light at infrared frequencies. The light from the seed diode laser is pulse amplified in a light amplifier, and converted into the ultraviolet by frequency tripling, quadrupling, or quintupling the infrared light. The narrow bandwidth, or relatively pure light, of the seed laser is preserved, and the pulse amplifier generates high peak light powers to increase the efficiency of the nonlinear crystals in the frequency conversion stage. Higher output powers may be obtained by adding a fiber amplifier to power amplify the pulsed laser light prior to conversion.

PATENTS↗

A comparison of the near-infrared spectral features of early-type galaxies in the Coma Cluster, the Virgo cluster and the field

Earlier researchers derived the relative distance between the Coma and Virgo clusters from color-magnitude relations of the early-type galaxies in each cluster. They found that the derived distance was color-dependent and concluded that the galaxies of similar luminosity in the two clusters differ in their red stellar populations. More recently, the color-dependence of the Coma-Virgo distance modulus has been called into question. However, because these two clusters differ so dramatically in their morphologies and kinematics, it is plausible that the star formation histories of the member galaxies also differed. If the conclusions of earlier researchers are indeed correct, then some signature of the resulting stellar population differences should appear in the near-infrared and/or infrared light of the respective galaxies. We have collected near-infrared spectra of 17 Virgo and 10 Coma early-type galaxies; this sample spans about four magnitudes in luminosity in each cluster. Seven field E/S0 galaxies have been observed for comparison. Pseudo-equivalent widths have been measured for all of the field galaxies, all but one of the Virgo members, and five of the Coma galaxies. The features examined are sensitive to the temperature, metallicity, and surface gravity of the reddest stars. A preliminary analysis of these spectral features has been performed, and, with a few notable exceptions, the measured pseudo-equivalent widths agree well with previously published values.

Houdashelt, Mark L.↗

Optical and infrared masers

Ongoing research progress in the following areas is described: (1) tunable infrared light sources and applications; (2) precision frequency and wavelength measurements in the infrared with applications to atomic clocks; (3) zero-degree pulse propagation in resonant medium; (4) observation of Dicke superradiance in optically pumped HF gas; (5) unidirectional laser amplifier with built-in isolator; and (6) progress in infrared metal-to-metal point contact tunneling diodes.

Source record↗

Physical processes in comets

When this program began in 1975 only limited photometry had been carried out on comets at any wavelength. Program goals were to observe many comets, including faint periodic comets, at a range of heliocentric distances in order to begin to understand the range of behavior among comets and in a given comet during its approach and departure from the sun. Then a study of the continuum of scattered light from dust was added. More recently the value of joint team observations in visible and infrared light has been recognized and utilized as often as possible. All 1978 to 1982 data was reanalyzed and 1983 to 1986 data analyzed in the framwork of the post-Halley paradigm, covering 25 comets in all. Four observing runs (June, July, Sept., and Jan.) with Hanner produced excellent results on Wilson, Bradfield, P/Klemola, and P/Borrelly and lesser data on other objects, including the last reported IR photometry of P/Halley. The Wilson and Halley data have been reduced.

Newburn, Ray L., Jr.↗