Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inhalation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Canister valve and actuator deposition in metered dose inhalers formulated with low-GWP propellants

A challenge in pressurised metered-dose inhaler (pMDI) formulation design is management of adhesion of the drug to the canister wall, valve and actuator internal components and surfaces. Wall-material interactions differ between transparent vials used for visual inspection and metal canister pMDI systems. This is of particular concern for low greenhouse warming potential (GWP) formulations where propellant chemistry and solubility with many drugs are not well understood. In this study, we demonstrate a novel application of X-ray fluorescence spectroscopy using synchrotron radiation to assay the contents of surrogate solution and suspension pMDI formulations of potassium iodide and barium sulphate in propellants HFA134a, HFA152a and HFO1234ze(E) using aluminium canisters and standard components. Preliminary results indicate that through unit life drug distribution in the canister valve closure region and actuator can vary significantly with new propellants. For solution formulations HFO1234ze(E) propellant shows the greatest increase in local deposition inside the canister valve closure region as compared to HFA134a and HFA152a, with correspondingly reduced actuator deposition. This is likely driven by chemistry changes. For suspension formulations HFA152a shows the greatest differences, due to its low specific gravity. These changes must be taken into consideration in the development of products utilising low-GWP propellants.

60 APPLIED LIFE SCIENCES↗

Protecting building occupants against the inhalation of outdoor-origin aerosols

During normal operations, buildings can protect their occupants from outdoor airborne particle hazards of all types, including airborne pollutants. A long-term international research effort has advanced our knowledge of building protection physics. Recently we have developed an operationally efficient, regional-scale methodology - Regional Shelter Analysis - to account for both building protection effects and the typical distribution of people in and among buildings. To provide input to this capability, we estimate here the degree of protection afforded by the currently existing US building stock. Here, we first assemble and summarize the published literature relevant to indoor particle losses including (a) deposition to indoor surfaces, (b) losses that occur when particles penetrate through the building envelope, and (c) heating, ventilation and air conditioning (HVAC) system filtration efficiencies as well as general building operating conditions. Building protection against inhaling particulate hazards varies strongly, by orders of magnitude, according to particle size, airborne particle loss rate, and to a lesser extent building use (occupancy). Protection increases modestly as particle size increases from 0.1 to 1 μm and significantly as particle size increases from 1 to 10 μm. Model results are placed in context with previously reported measurements. Suggestions for future work, including enhanced validation datasets are provided.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Translating nanoparticle dosimetry from conventional in vitro systems to occupational inhalation exposures

As encouraged by Toxicity Testing in the 21st Century, researchers increasingly apply high-throughput in vitro approaches to identify and characterize nanoparticle hazards, including conventional aqueous cell culture systems to assess respiratory hazards. Translating nanoparticle dose from conventional toxicity testing systems to relevant human exposures remains a major challenge for assessing occupational risk of nanoparticle exposures. Here, we explored existing computational tools and data available to translate nanoparticle dose metrics from cellular test systems to inhalation exposures of silver nanoparticles in humans. We used the Multiple-Path Particle Dosimetry (MPPD) Model to predict deposition of humans exposed to 20 and 110 nm silver nanoparticles at 0.9 µg/m3 over an 8 hr period, the proposed a National Institute of Occupational Safety and Health (NIOSH) recommended exposure limit (REL). MPPD predicts 1.88 and 0.98 µg of silver deposited in an 8 hr period for 20 and 110 nm nanoparticles, respectively, with 20 nm particles displaying nearly 11-fold higher total surface area deposited. Peak nanoparticle concentrations occurred more proximal in the pulmonary tract compared to mass deposition patterns (generation 5 vs. generations 20-21, respectively) due to regional differences in lung lining fluid volumes. Assuming 0.4% nanoparticle dissolution by mass as previously measured, we predict peak concentrations of silver ions in cells of 0.24 and 0.17 µg/mL for 20 and 110 nm particles, respectively. Both predicted concentrations are below the measured toxic threshold of 1.7 µg/mL of silver ions in cells from in vitro assessments. Assuming 4% dissolution by mass, we predict 10-fold higher silver concentrations in tissues, peaking at 2.4 and 1.7 µg/mL, for 20 and 110 nm nanoparticles respectively, exceeding the observed in vitro toxic threshold and highlighting the importance and sensitivity of dissolution rates. Overall, this approach offers a framework for extrapolating nanotoxicity results from in vitro cell culture systems to human exposures. Aligning appropriate dose metrics from in vitro and in vivo hazard characterizations and human pulmonary doses from occupational exposures are critical components for successful nanoparticle risk assessment and worker protection and provide guidance for designing future in vitro studies aimed at relevant human exposures.

Smith, Jordan N.↗

Volatile propellant droplet evaporation measurements in metered dose inhaler sprays

Many aerosol products rely on the rapid vaporization of volatile propellants to produce a fine spray. In the simplest case, these are binary mixtures of propellant and a delivered product which undergo a flash-evaporation process leaving only the less volatile product in the resultant droplet. In more complex applications, such as pressurized metered-dose inhalers, the non-propellant component may contain dissolved or suspended drug which precipitates or dries to form a matured particle. The size and morphology of the particles depend strongly on the time-history of the droplet as the propellant evaporates. However, measuring the dynamic evaporation processes that occur in dense sprays containing millions of droplets is challenging. In this paper, we demonstrate a novel application of Ultra Small Angle X-ray Scattering to measure the bulk composition of volatile HFC134a–ethanol sprays and compare the obtained results with simple evaporation models in a dry nitrogen environment. The data reveal that diffusion-limiting processes inside the droplet are equally important as external convection and mixing-limited factors in determining evaporative timescales.

42 ENGINEERING↗

Modeling Plutonium Decorporation in a Female Nuclear Worker Treated with Ca-DTPA after Inhalation Intake

The present work models plutonium (Pu) biokinetics in a female former nuclear worker. Her bioassay measurements are available at the US Transuranium and Uranium Registries. The worker was internally exposed to a plutonium-americium mixture via acute inhalation at a nuclear weapons facility. She was medically treated with injections of 1 g Ca-DTPA on days 0, 5, and 14 after the intake. Between days 0 and 20, fecal and urine samples were collected and analyzed for 239 Pu and 241 Am. Subsequently, she was followed up for bioassay monitoring over 14 y, with additional post-treatment urine samples collected and analyzed for 239 Pu. The uniqueness of this dataset is due to the availability of: (1) both early and long-term bioassay data from a female with plutonium intake; (2) data on chelation therapy for a female; and (3) fecal measurement results. Chelation therapy with Ca- and/or Zn-salts of DTPA is known to aid in reducing the internal radiation dose by enhancing the excretion of plutonium and americium from the body. Such enhancement affects plutonium biokinetics in the human body, posing a challenge to the internal dose assessment. The current radiation dose assessment practice is to exclude the data affected by Ca-DTPA from the analysis. The present analysis is the first to explicitly model the chelation-affected bioassay data in a female by using a newly developed chelation model. Thus, the bioassay data collected during and after the Ca-DTPA administrations were used for biokinetic modeling and dose assessment. The Markov Chain Monte Carlo method was used to investigate model parameter uncertainty, based on the bioassay data and assumed prior probability distributions. A χ 2 /nData (number of data points) ≈ 1 was observed in this study, which indicates self-consistency of the data with the model. Results of this study show that the worker’s 239 Pu intake was 12 Bq, with a committed effective dose to the whole-body of 1.2 mSv and a committed equivalent dose to the bone surfaces, liver, and lungs of 37.8, 9.1, and 0.8 mSv, respectively. This study also discusses the worker’s dose reduction due to chelation treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Broadly neutralizing humanized SARS-CoV-2 antibody binds to a conserved epitope on Spike and provides antiviral protection through inhalation-based delivery in non-human primates

The COVID-19 pandemic represents a global challenge that has impacted and is expected to continue to impact the lives and health of people across the world for the foreseeable future. The rollout of vaccines has provided highly anticipated relief, but effective therapeutics are required to further reduce the risk and severity of infections. Monoclonal antibodies have been shown to be effective as therapeutics for SARS-CoV-2, but as new variants of concern (VoC) continue to emerge, their utility and use have waned due to limited or no efficacy against these variants. Furthermore, cumbersome systemic administration limits easy and broad access to such drugs. As well, concentrations of systemically administered antibodies in the mucosal epithelium, a primary site of initial infection, are dependent on neonatal Fc receptor mediated transport and require high drug concentrations. To reduce the viral load more effectively in the lung, we developed an inhalable formulation of a SARS-CoV-2 neutralizing antibody binding to a conserved epitope on the Spike protein, ensuring pan-neutralizing properties. Administration of this antibody via a vibrating mesh nebulization device retained antibody integrity and resulted in effective distribution of the antibody in the upper and lower respiratory tract of non-human primates (NHP). In comparison with intravenous administration, significantly higher antibody concentrations can be obtained in the lung, resulting in highly effective reduction in viral load post SARS-CoV-2 challenge. This approach may reduce the barriers of access and uptake of antibody therapeutics in real-world clinical settings and provide a more effective blueprint for targeting existing and potentially emerging respiratory tract viruses.

60 APPLIED LIFE SCIENCES↗

A Review of Variables Impacting the Indoor Inhalation Radon Equilibrium Factor (FEQ)

With radon and its daughter products estimated as the second leading cause of lung cancer in the United States, it is imperative to understand their relative equilibrium inside commercial, community, and residential dwellings. The radon indoor inhalation fractional equilibrium factor (F eq ) quantifies the disequilibrium between radon and its progeny in indoor air, and recent advances have shown how air exchange rates (ACH) influence F eq . These numerically derived ACH-dependent F eq values are incorporated into the U.S. EPA's Radon Vapor Intrusion Screening Level (RVISL) calculator, which assists risk assessors in evaluating radon exposure. To advance the risk assessment science of actinon (Rn-219), thoron (Rn-220), and radon (Rn-222), the impact of variables such as indoor aerosol concentration and composition, outdoor air quality, household-specific characteristics, and environmental/meteorological conditions on the F eq must be examined. The primary objective of this research is to analyze these additional variables to determine the usefulness of incorporating such adjustment factors into the RVISL calculator and to identify areas of future research. Studies regarding the influence of these parameters are presented along with recommendations regarding the adjustment of the numerically derived F eq value. For example, elevated indoor aerosol concentrations, such as those originating from outdoor PM 2.5 or cigarette smoke, increase the abundance of accumulation- mode particles indoors, which in turn raises F eq values by facilitating the attachment of radon progeny to these aerosols. Smoking increases both the bronchial dose and F eq , while regions with high smog levels demonstrate the impact of regional air quality on F eq . In contrast, air cleaning systems and purifiers have been shown to reduce the F eq , suggesting that these systems could help mitigate radon exposure. Additionally, higher F eq values are typically observed during winter when ventilation rates are lower. This paper presents adjustment factors that may be applied to the RVISL F eq , emphasizing the need for further research to refine these variables and ensure accurate risk assessments in diverse environments. Applying these adjustment factors will minimize calculator over- and underestimations, providing a more accurate representation of the real-world risk associated with radon.

54 ENVIRONMENTAL SCIENCES↗

Uncertainty Analysis of Inhalation Dose Coefficients for Nuclear Incident Response

This study addressed the need to characterize variability in inhalation dose coefficients due to uncertainties in respiratory tract deposition, systemic biokinetics, and physiological parameters. A Python-based implementation of the International Commission on Radiological Protection Publication 66 Human Respiratory Tract Model was developed called the Radiological Exposure Dose Calculator (REDCAL) to propagate parameter uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗

Olfactory bulb units - Activity correlated with inhalation cycles and odor quality.

Single olfactory bulb units were studied in two macrosmatic species of rodents under conditions intended to preserve the cyclical stimulation which normally accompanies nasal breathing. Patterns of unit activity related to the inhalation cycle were observed in all animals, often in the absence of specific stimuli, and could not be explained in simple mechanical terms. Distinctive changes in these patterns occurred in response to certain odors, and were generally independent of changes in the overall firing frequency. These findings indicate that a change in the overall firing frequency of unit discharges is neither a necessary nor sufficient measure of responsiveness to odors in the rodent olfactory bulb, and that stimulus-specific temporal distributions of unit firing may be involved in olfacto-endocrine activities.

Macrides, F.↗

Improved inhalation technology for setting safe exposure levels for workplace chemicals

Threshold Limit Values recommended as allowable air concentrations of a chemical in the workplace are often based upon a no-observable-effect-level (NOEL) determined by experimental inhalation studies using rodents. A 'safe level' for human exposure must then be estimated by the use of generalized safety factors in attempts to extrapolate from experimental rodents to man. The recent development of chemical-specific physiologically-based toxicokinetics makes use of measured physiological, biochemical, and metabolic parameters to construct a validated model that is able to 'scale-up' rodent response data to predict the behavior of the chemical in man. This procedure is made possible by recent advances in personal computer software and the emergence of appropriate biological data, and provides an analytical tool for much more reliable risk evaluation and airborne chemical exposure level setting for humans.

Stuart, Bruce O.↗

Toxicokinetics of inhaled bromotrifluoromethane (Halon 1301) in human subjects

Bromotrifluoromethane (Halon 1301, CBrF3), is used as a fire extinguishant in the Space Shuttle, where several scenarios, such as a fire or a faulty alarm, could lead to its discharge resulting in a Halon 1301 concentration of up to 1 percent in the cabin atmosphere. The effect of Halon 1301 on mental performance and physiologic function was investigated in a NASA-sponsored human inhalation study in which four pairs of male subjects were each exposed in a double-blind fashion for 24 hr to 1 percent Halon 1301 and to air in two exposures about 1 week apart. Blood and breath samples from the exposed subjects were collected to provide dosimetric and toxicokinetic information. Halon 1301 blood levels increased rapidly and approached a steady state within 2 hr of the beginning the exposure; the steady-state concentration was approximately 3-4.5 microg/ml. Breath samples collected during exposures closely reflected chamber concentrations. Analysis of postexposure blood samples revealed that Halon 1301 was eliminated biphasically with an average t(1/2) alpha and t(1/2) beta of 4.5 min and 200 min, respectively.

Lam, C. W.↗

Inhalation Toxicity of Ground Lunar Dust Prepared from Apollo-14 Soil

Within the decade one or more space-faring nations intend to return humans to the moon for more in depth exploration of the lunar surface and subsurface than was conducted during the Apollo days. The lunar surface is blanketed with fine dust, much of it in the respirable size range (<10 micron). Eventually, there is likely to be a habitable base and rovers available to reach distant targets for sample acquisition. Despite designs that could minimize the entry of dust into habitats and rovers, it is reasonable to expect lunar dust to pollute both as operations progress. Apollo astronauts were exposed briefly to dust at nuisance levels, but stays of up to 6 months on the lunar surface are envisioned. Will repeated episodic exposures to lunar dust present a health hazard to those engaged in lunar exploration? Using rats exposed to lunar dust by nose-only inhalation, we set out to investigate that question.

James, John T.↗

Tank 11H Low Temperature Aluminum Dissolution and Inhalation Dose Potential Analyses at Savannah River Site – 26018

Currently, there is approximately 34 million gallons of high-level radioactive tank waste in the Tank Farm at the Savannah River Site (SRS). The ultimate goal of operations at the Tank Farm is to remove the high level waste (HLW) from the tanks followed by stabilization of the waste through vitrification of the HLW into glass or grouting the decontaminated waste into saltstone. After bulk removal of the HLW consisting of sludge, saltcake, and supernatant, further efforts are made to reduce the residual waste present in the tank in order to declare preliminary cease waste removal (PCWR) signifying completion of HLW removal. These reduction efforts can include tank washing to remove soluble salts and radioisotopes and dissolution of solids including aluminum. Aluminum in the form of gibbsite and boehmite is relatively insoluble in water. Through addition of aqueous sodium hydroxide, the aluminum can be dissolved at mild temperatures. In order for the waste tank to meet closure mode requirements of the Concentration, Storage, and Transfer Facilities (CSTF), which includes the Tank Farm, Documented Safety Analysis (DSA), a component of the safety basis, the inhalation dose potential (IDP) and the radiolytic hydrogen generation rate of the stored waste must be demonstrated to be lower than their respective designated limits. These parameters are calculated from measured radiochemical analyses of isotopes that emit a high amount of radioactivity including Cs-137, Sr-90, Pu-238, Pu-239, Pu-240, Pu-241, Am-241, and Cm-244. Following the low temperature aluminum dissolution (LTAD) process, Tank 11H slurry samples were pulled from the tank and sent to Savannah River National Laboratory (SRNL) to measure the extent of aluminum dissolution, hydroxide concentration, densities of slurry and supernatant, weight percent solids analyses, and radionuclide activities. The analyses of the composite sample found that approximately 90% of the total aluminum in the slurry was dissolved, indicating successful reduction of the insoluble aluminum in the waste tank. Additionally, the weight percent insoluble solids (slurry basis) measurement of the composite sample was found to be approximately 1%, demonstrating that minimal solids still remain in the tank. Finally, the radiochemical analyses of the composite sample determined that the waste contents of the tank met the IDP and radiolytic hydrogen generation rate requirements of the CSTF DSA. These measurements have shown that the LTAD process in Tank 11H was successful in waste reduction efforts and a positive step towards declaring PCWR and tank closure at SRS.

Dekarske, John [Savannah River National Laboratory↗