SEARCH · Search NASA
Results for “Initialization method”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A fully automatic method yielding initial models from high-resolution cryo-electron microscopy maps
Here, we report a fully automated procedure for the optimization and interpretation of reconstructions from cryo-electron microscopy (cryo-EM) data, available in Phenix as phenix.map_to_model. We applied our approach to 476 datasets with resolution of 4.5 Å or better, including reconstructions of 47 ribosomes and 32 other protein–RNA complexes. The median fraction of residues in the deposited structures reproduced automatically was 71% for reconstructions determined at resolutions of 3 Å or better and 47% for those at resolutions worse than 3 Å.
Hunting the most distant stars in the Milky Way: methods and initial results
We present a new catalog of 404 M giant candidates found in the UKIRT Infrared Deep Sky Survey (UKIDSS). The 2400 deg{sup 2} available in the UKIDSS Large Area Survey Data Release 8 resolve M giants through a volume four times larger than that of the entire Two Micron All Sky Survey. Combining near-infrared photometry with optical photometry and proper motions from the Sloan Digital Sky Survey yields an M giant candidate catalog with less M dwarf and quasar contamination than previous searches for similarly distant M giants. Extensive follow-up spectroscopy of this sample will yield the first map of our Galaxy's outermost reaches over a large area of sky. Our initial spectroscopic follow-up of ∼30 bright candidates yielded the positive identification of five M giants at distances ∼20-90 kpc. Each of these confirmed M giants have positions and velocities consistent with the Sagittarius stream. The fainter M giant candidates in our sample have estimated photometric distances ∼200 kpc (assuming [Fe/H] = 0.0), but require further spectroscopic verification. The photometric distance estimates extend beyond the Milky Way's virial radius, and increase by ∼50% for each 0.5 dex decrease in assumed [Fe/H]. Given the number of M giant candidates, initial selection efficiency, and volume surveyed, we loosely estimate that at least one additional Sagittarius-like accretion event could have contributed to the hierarchical build-up of the Milky Way's outer halo.
A GALACTIC MOLECULAR CLOUD CLUMP CATALOG FROM HI-GAL DATA: METHOD AND INITIAL RESULTS COMPARISON WITH BGPS
As the precursors to stellar clusters, it is imperative that we understand the distribution and physical properties of dense molecular gas clouds and clumps. Such a study has been done with the ground-based Bolocam Galactic Plane Survey (BGPS). Now the Herschel infrared GALactic plane survey (Hi-GAL) allows us to do the same with higher-quality data and complete coverage of the Galactic plane. We have made a pilot study comparing dense molecular gas clumps identified in Hi-GAL and BGPS, using six 2° × 2° regions centered at Galactic longitudes of ℓ=11{sup ∘}, 30°, 41°, 50°, 202°, and 217°. We adopted the BGPS methodology for identifying clumps and estimating distances, leading to 6198 clumps being identified in our substudy, with 995 of those having well-constrained distances. These objects were evenly distributed with Galactic longitude, a consequence of Hi-GAL being source confusion limited. These clumps range in mass from 10{sup −2} to 10{sup 5} M{sub ⊙} and have heliocentric distances of up to 16 kpc. When clumps found in both surveys are compared, we see that distances agree within 1 kpc and ratios of masses are of the order of unity. This serves as an external validation for BGPS and instills confidence as we move forward to cataloging the clumps from the entirety of Hi-GAL. In addition to the sources that were in common with BGPS, Hi-GAL found many additional sources, primarily due to the lack of atmospheric noise. We expect Hi-GAL to yield 2 × 10{sup 5} clumps, with 20% having well-constrained distances, an order of magnitude above what was found in BGPS.
A Conservative Finite-Volume Based Interface-Tracking Algorithm Using the Signed Distance Function
Methods for tracking an interface between two fluid phases are developed to ensure desired fluid properties, conservation, and stability are preserved in a finitevolume (FV) discretization. Here, the interface is tracked using a level set method where the signed distance function implicitly defines the interface. Marching methods are used to evaluate the value of the signed distance function, including a novel initialization method to initialize any implicit function to the signed distance function around sharp corners in the level set. Global conservation and consistency with a set of governing equations is enforced by a compression coefficient that measures the volumetric compression or expansion due to inaccuracies in the level set evaluation. A redistribution method is integrated into the volume correction to eliminate the small-cell instability while maintaining global conservation. This suite of methods is implemented and tested using static uniform velocity, and potential flow cases with multiple interface geometries. Results show these methods achieve up to second order accuracy, and are conservative. The application for these methods is intended to track the interface of a 3D printing filament in a finite-volume discretization of the all-speed Navier-Stokes equations.
Concept and simulation study of a novel localization method for robotic endoscopic capsules using multiple positron emission markers
Purpose: Over the last decade, wireless capsule endoscope has been the tool of choice for noninvasive inspection of the gastrointestinal tract, especially in the small intestine. However, the latest clinical products have not been equipped with a sufficiently accurate localization system which makes it difficult to determine the location of intestinal abnormalities, and to apply follow-up interventions such as biopsy or drug delivery. In this paper, the authors present a novel localization method based on tracking three positron emission markers embedded inside an endoscopic capsule. Methods: Three spherical {sup 22}Na markers with diameters of less than 1 mm are embedded in the cover of the capsule. Gamma ray detectors are arranged around a patient body to detect coincidence gamma rays emitted from the three markers. The position of each marker can then be estimated using the collected data by the authors’ tracking algorithm which consists of four consecutive steps: a method to remove corrupted data, an initialization method, a clustering method based on the Fuzzy C-means clustering algorithm, and a failure prediction method. Results: The tracking algorithm has been implemented inMATLAB utilizing simulation data generated from the Geant4 Application for Emission Tomography toolkit. The results show that this localization method can achieve real-time tracking with an average position error of less than 0.4 mm and an average orientation error of less than 2°. Conclusions: The authors conclude that this study has proven the feasibility and potential of the proposed technique in effectively determining the position and orientation of a robotic endoscopic capsule.
Inpainting with sparse linear combinations of exemplars
We introduce a new exemplar-based inpainting algorithm based on representing the region to be inpainted as a sparse linear combination of blocks extracted from similar parts of the image being inpainted. This method is conceptually simple, being computed by functional minimization, and avoids the complexity of correctly ordering the filling in of missing regions of other exemplar-based methods. Initial performance comparisons on small inpainting regions indicate that this method provides similar or better performance than other recent methods.
Effects of Trigger Method on Fire Propagation during the Thermal Runaway Process in Li-ion Batteries
Lithium-ion batteries are prone to fire hazards due to the possibility of thermal runaway propagation. During battery product development and subsequent safety tests for design validation and safety certification, the thermal runaway onset is triggered by various test methods such as nail penetration, thermal ramp, or external short circuit. This failure initiation method affects the amount of heat contributions and the composition of gas generations. This study compares two such trigger methods, external heating and using a thermally-activated internal short circuit device (ISCD). The effects of the trigger method on total heat generation are experimentally investigated within 18650 cylindrical cells at single cell level as well as at multiple cell configuration level. The severity of failure was observed to be worse for cells with ISCDs at single cell level, whereas quite the opposite results were observed at multiple cell configuration level. A preliminary numerical analysis was performed to better understand the battery safety performance with respect to thermal runaway trigger methods and heat transfer conditions.
Development of high throughput light-sheet fluorescence lifetime imaging microscopy for 3D functional imaging of metabolic pathways in plant and microorganisms (Final Technical Report)
This research program will enable new biochemical contrast in the nanosecond lifetime domain through use of the recently demonstrated electro-optic fluorescence lifetime imaging technique (EO-FLIM) for wide-field lifetime imaging. The Stanford/Stanford Linear Accelerator Center multidisciplinary collaboration -- physics, applied physics, and structural biology -- will develop a light-sheet fluorescence lifetime imaging microscope for functional studies of microbial and plant metabolic pathways and dynamic interactions between plants and microorganisms in the rhizosphere. The proposed approach overcomes the imaging time bottleneck associated with existing fluorescence lifetime imaging methods. Initial demonstrations have shown a factor of 100,000 improvement in photon throughput compared to existing methods. High photon efficiency allowed the first wide-field fluorescence lifetime imaging of single molecules. Recent work has improved the technique’s repetition rate to enable compatibility with mode-locked lasers and demonstrated the combination of wide-field fluorescence lifetime imaging with super-resolution localization microscopy, observations of single molecule dynamics, and observation of donor lifetime quenching in single-molecule imaging. These results were achieved on standard camera sensors and would not have been possible with other wide-field approaches. The throughput and photon economy of the EO-FLIM method enables new BER-relevant imaging opportunities. In particular, scanned single- and two-photon light-sheet excitation will be used to achieve volumetric imaging with time-domain contrast.
Spectroradiometric detection of competitor diatoms and the grazer Poteriochromonas in algal cultures
To address challenges in early detection of pond pests, we have extended a spectroradiometric monitoring method, initially demonstrated for measurement of pigment optical activity and biomass, to the detection of algal competitors and grazers. The method relies upon measurement and interpretation of pond reflectance spectra spanning from the visible into the near-infrared. Reflectance spectra are acquired every 5 min with a multi-channel, fiber-coupled spectroradiometer, providing monitoring of algal pond conditions with high temporal frequency. The spectra are interpreted via numerical inversion of a reflectance model, in which the above-water reflectance is expressed in terms of the absorption and backscatter coefficients of the cultured species, with additional terms accounting for the pigment fluorescence features and for the water-surface reflection of sunlight and skylight. With this method we demonstrate detection of diatoms and the predator Poteriochromonas in outdoor cultures of Nannochloropsis oceanica and Chlorella vulgaris, respectively. Further, the relative strength of these signatures is compared to microscopy and sequencing analysis. Spectroradiometric detection of diatoms is then further assessed on beaker-contained mixtures of Microchloropsis salina with Phaeodactylum tricornutum, Thalassiosira weissflogii, and Thalassiosira pseudonana, respectively, providing an initial evaluation of the sensitivity and specificity of detecting pond competitors.
Lab-Scale Demonstration of Plutonium Purification by Anion Exchange, Plutonium(IV) Oxalate Precipitation, and Calcination to Plutonium Oxide to Support the MOX Feed Mission
H-Canyon and HB-Line are tasked with the production of PuO 2 from a feed of plutonium metal. The PuO 2 will provide feed material for the MOX Fuel Fabrication Facility. After dissolution of the Pu metal in H-Canyon, the solution will be transferred to HB-Line for purification by anion exchange. Subsequent unit operations include Pu(IV) oxalate precipitation, filtration and calcination to form PuO 2 . This report details the results from SRNL anion exchange, precipitation, filtration, calcination, and characterization tests, as requested by HB-Line1 and described in the task plan. This study involved an 80-g batch of Pu and employed test conditions prototypical of HB-Line conditions, wherever feasible. In addition, this study integrated lessons learned from earlier anion exchange and precipitation and calcination studies. H-Area Engineering selected direct strike Pu(IV) oxalate precipitation to produce a more dense PuO 2 product than expected from Pu(III) oxalate precipitation. One benefit of the Pu(IV) approach is that it eliminates the need for reduction by ascorbic acid. The proposed HB-Line precipitation process involves a digestion time of 5 minutes after the time (44 min) required for oxalic acid addition. These were the conditions during HB-line production of neptunium oxide (NpO 2 ). In addition, a series of small Pu(IV) oxalate precipitation tests with different digestion times were conducted to better understand the effect of digestion time on particle size, filtration efficiency and other factors. To test the recommended process conditions, researchers performed two nearly-identical larger-scale precipitation and calcination tests. The calcined batches of PuO 2 were characterized for density, specific surface area (SSA), particle size, moisture content, and impurities. Because the 3013 Standard requires that the calcination (or stabilization) process eliminate organics, characterization of PuO 2 batches monitored the presence of oxalate by thermogravimetric analysis-mass spectrometry (TGA-MS). To use the TGA-MS for carbon or oxalate content, some method development will be required. However, the TGA-MS is already used for moisture measurements. Therefore, SRNL initiated method development for the TGA-MS to allow quantification of oxalate or total carbon. That work continues at this time and is not yet ready for use in this study. However, the collected test data can be reviewed later as those analysis tools are available.
A Radiotracer Assessment of Pulsatile Flow
Positron Emission Particle Tracking (PEPT) is a Lagrangian measurement technique used to examine flow behavior. In PEPT, tracer particles are labeled with a positron-emitting radionuclide. The emitted positron annihilates with a nearby electron, producing two back-to-back gamma rays of 511 keV. These gamma rays are detected using a Positron Emission Tomography (PET) scanner. The PET scanner monitors the detection sites and corresponding time in time steps on the order of milliseconds. The detection sites of the two gamma rays are connected via lines of response (LORs), and with multiple LORs a particle location is determined. Many methods have been explored in the past to track tracer particles in the field of view (FOV) of the scanner. The initial method for single particle PEPT was established by Parker et al. This method was refined to track multiple particles by Yang et al. Another method was developed by Bickell, et al based on the 'line density' of LORs in the scanner's FOV. This method was modified by Wiggins, et al to locate and track multiple particles in the FOV without a priori information about the particles. Pulsatile flow is seen in human blood flow and hydraulic and mechanical systems. The pressure gradient of the flow has been studied in an elastic tube with varying viscosity and stiffness by Anssari-Benam et al. Velocity and Reynold stresses have been examined in a rigid tube by Adamec et al. In this research, a new pulsatile flow system is constructed to analyze 3D velocity fields in Lagrangian specifications with capability of conversion to Eulerian specification. The absolute pressure across the test section is also examined. (authors)
The Development of the CMS Zero Degree Calorimeters to Derive the Centrality of AA Collisions
The centrality of РЬРЬ collisions is derived using correlations from the zero degree calorimeter (ZDC) signal and pixel multiplicity at the Compact Muon Solenoid (CMS) Experiment using data from the heavy ion run in 2010. The method to derive the centrality takes the two-dimensional correlation between the ZDC and pixels and linearizes it for sorting events. The initial method for deriving the centrality at CMS uses the energy deposit in the HF detector, and it is compared to the centrality derived Ьу the correlations in ZDC and pixel multiplicity. This comparison highlights the similarities between the results of both methods in central collisions, as expected, and deviations in the results in peripheral collisions. The ZDC signals in peripheral collisions are selected Ьу low pixel multiplicity to oЬtain а ZDC neutron spectrum, which is used to effectively gain match both sides of the ZDC
An improved method to access initial states in relativistic heavy-ion collisions
Abstract Observables in heavy-ion collisions are generally categorized into centralities, which reflect an average over events within a range of impact parameters including a wide variety of initial-state configurations. A multiple binning method using spectator neutrons within each centrality has been shown to provide access to events with rare initial-state conditions. This work suggests an improvement in quantifying the difference between standard centrality and spectator neutron binning towards accessing the initial-state properties. A selection of events with higher initial-state density at a fixed participating nucleon number was observed to result in larger final-state particle production and smaller elliptic flow. The relative difference between observables in centrality and spectator binning shows reduced sensitivity for the observables dominated by impact parameter fluctuations in the initial state, such as triangular flow. This property renders the spectator binning method a good candidate for separating geometric contributions from random fluctuations in the initial state towards final-state observables.
Quantifying EGS Reservoir Complexity with an Integrated Geophysical Approach-Improved Resolution Ambient Seismic Noise Interferometry
The primary goal of the project was met, as improved resolution (from kilometers to tens/hundreds of meters and to a depth of at least 3 km) was added to the seismic interferometry-estimated parameters relative to the work reported in AltaRock Energy Inc. (2014) for the Dixie Valley Geothermal Wellfield. A procedure for initial fault identification, using seismic interferometry, was developed. The project team further improved, and applied a new, cost-effective, and non-invasive exploration method, developed and validated since 2010, during two previous experiments, at Dixie Valley and Soda Lake, Nevada. The method, initially designed for hydrothermal exploration, was adapted to EGS exploration conditions, which require deeper crustal information. Regions of elevated energy for both the 2-7 Hz and 5-15 Hz frequency bands are located above intersections of multiple faults. Thus, an unprecedented, innovative seismic field deployment and ambient seismic noise and signal processing were successfully used to estimate crustal structure and to identify fault locations at depths up to 3 km, at a cost per kilometer of survey that in some cases may be as much as ten times less than the cost of a controlled-source survey. Based on valid and useful seismic data collected and analyzed during Phase I, in Phase II the team has further quantified statistically the advantage of using seismic analysis, in combination with other geological and geophysical techniques, for EGS target identification. A power spectral density analysis of the passive-seismic empirical Green’s functions reveals significantly higher power recorded over the exploration area at the power plant, and in the drilling area, near the BB station 10201, especially on the horizontal components. In this study, the most important relationship observed during the prior report, namely the one between velocity and temperature was explored. The areas that show anomalously high predicted temperature in the geostatistics occur where multiple faults intersect. Not surprisingly, such areas span between the Dixie Valley range front fault and the basin-ward Piedmont faults, in the vicinity of numerous wells. These locations also fall in the area of high EGS favorability from the prior 2014 study. The anomalies also coincide with the high power spectral density values. The result of altering all favorability criteria for the new data reached a maximum of 1/8th of a point and were not large enough to change any favorability value reported in the 2014 study. The new data reinforce the results obtained from the previous 2014 study. The current high-resolution ambient seismic noise project provided excellent results in defining faults in the wellfield. As such the identification of known faults by the project demonstrated the utility of this method for identifying faults at an exploration stage in geothermal development. Such fault identification, while extremely useful in exploration investigation, has not added sufficient new data for the generation of significantly different DVGW favorability maps in the current project. We believe the cost savings of our passive-seismic technique for EGS, over common industry active-source survey techniques, may have a minimum of 30%, and a maximum of 90%. There are many significant non-cost benefits of passive seismic surveys. Our passive-source method provides an environmentally-friendly seismic survey with minimal to negligible impacts. The economic benefit is greater EGS project feasibility.
Facile hydrothermal method synthesis of coralline-like Li{sub 1.2}Mn{sub 0.54}Ni{sub 0.13}Co{sub 0.13}O{sub 2} hierarchical architectures as superior cathode materials for lithium-ion batteries
Highlights: • A coralline-like Li{sub 1.20}Mn{sub 0.54}Ni{sub 0.13}Co{sub 0.13}O{sub 2} cathode was synthesized by hydrothermal method. • Initial discharge capacity of 250.2 mAh g{sup −1} for the cathode was obtained at 0.1 C. • A high reversible specific capacity of 210.2 mAh g{sup −1} after 100 cycles was acquired. • The high capacity retention of 84.5% was obtained even after 200 cycles at 10 C. - Abstract: A coralline-like lithium-rich layered cathode material with homogeneous composition of Li{sub 1.20}Mn{sub 0.54}Ni{sub 0.13}Co{sub 0.13}O{sub 2} has been successfully synthesized via a facile ethanolamine (EA)-mediated hydrothermal method route, with subsequent calcination at 850 °C. An initial specific discharge capacity of 250.2 mAh g{sup −1} and a reversible specific capacity of 210.2 mAh g{sup −1} after 100 cycles at a constant density of 25 mA g{sup −1} (1 C = 250 mA g{sup −1}) are acquired. Even at 10 C, it still delivers a discharge capacity of approximately 100 mA h g{sup −1}, thereby indicating its excellent high power performance. The sample also shows enhanced cycling performance with 88.5%, 79.9% and 90.5% of capacity retention after 100 cycles at 0.5, 5 and 10 C rates, respectively. Besides, 84.5% of initial capacity is retained even after 200 cycles at 10 C. Consequently, the fascinating electrochemical performance may facilitate the coralline-like LMNCO composite to be a promising alternative cathode for LIBs with a high application potential.
Benchmarking optimization methods for materials research: Gradient descent and Bayesian optimization for lithium-ion battery aging diagnostics
Accurate and efficient parameter estimation is essential for battery diagnostics and aging analysis. Here, in this study, we compare two optimization-based approaches—gradient descent and Bayesian optimization—for extracting parameters from differential voltage analysis in lithium-ion batteries. While these techniques are widely used, their relative strengths and limitations for this application are not well understood. The study evaluates the trade-offs between these methods in terms of result quality, computational cost, and reliability within this specific application. The diagnostic results from our battery data suggest adopting gradient descent as an initial method for rapid and efficient analysis, while employing more stable optimization techniques, such as Bayesian optimization, as a verification step to mitigate potential instability. Comparing the two methods provides information on algorithmic choice, while inspiring further discussions on selecting appropriate techniques for specific research tasks.
Overview of the SCEC/USGS Community Stress Drop Validation Study Using the 2019 Ridgecrest Earthquake Sequence
We present initial findings from the ongoing Community Stress Drop Validation Study to compare spectral stress-drop estimates for earthquakes in the 2019 Ridgecrest, California, sequence. This study uses a unified dataset to independently estimate earthquake source parameters through various methods. Stress drop, which denotes the change in average shear stress along a fault during earthquake rupture, is a critical parameter in earthquake science, impacting ground motion, rupture simulation, and source physics. Spectral stress drop is commonly derived by fitting the amplitude-spectrum shape, but estimates can vary substantially across studies for individual earthquakes. Sponsored jointly by the U.S. Geological Survey and the Statewide (previously, Southern) California Earthquake Center our community study aims to elucidate sources of variability and uncertainty in earthquake spectral stress-drop estimates through quantitative comparison of submitted results from independent analyses. The dataset includes nearly 13,000 earthquakes ranging from M 1 to 7 during a two-week period of the 2019 Ridgecrest sequence, recorded within a 1° radius. Here, in this article, we report on 56 unique submissions received from 20 different groups, detailing spectral corner frequencies (or source durations), moment magnitudes, and estimated spectral stress drops. Methods employed encompass spectral ratio analysis, spectral decomposition and inversion, finite-fault modeling, ground-motion-based approaches, and combined methods. Initial analysis reveals significant scatter across submitted spectral stress drops spanning over six orders of magnitude. However, we can identify between-method trends and offsets within the data to mitigate this variability. Averaging submissions for a prioritized subset of 56 events shows reduced variability of spectral stress drop, indicating overall consistency in recovered spectral stress-drop values.