Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integrated Science Instrument Module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation-Hardened GaN-Based Wireless Communications Architectures for Terrestrial Nuclear Reactor Sensing and Instrumentation

Wireless technologies have become increasingly common in applications, ranging from close proximity inductive communication links in medical devices to short-range Bluetooth and WiFi communications and longer-range cellular communications. Nonetheless, these technologies are unsuitable for use in or around nuclear reactors due to the extreme radiation and temperatures inherent in these environments and their associated significant degradative effects on electronics hardware. However, recent work in wide bandgap– based electronics has shown promise for gallium nitride (GaN) as an emerging technology for the realization of practical wireless communications systems for use in harsh environments. This report presents initial progress on the development of wireless communications architectures designed specifically for nuclear reactor application, based on inherently radiation-hardened (rad-hard) GaN technology. Prior work on rad-hard analog communications topologies is reviewed, and several digital modulation and encoding schemes that utilize GaN-based electronics devices are newly proposed for application in reactor environments. Continuous-time and discrete-time system simulations were performed, and results are presented for the preliminary transmitter and receiver designs, respectively. In addition, an overview of a software-defined radio testbed, designed for communications protocol development, is provided. Future work will focus on implementing candidate radiation-resistant wireless architectures using a research AlGaN/GaN high electron mobility transistor (HEMT) integrated circuit process, which is available at the Ohio State University, and irradiation studies will be carried out to assess the true potential of this technology for reactor application.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Progress Towards Microcalorimeter Gamma Spectroscopy Analysis for Nuclear Fuel Separations

The High Efficiency and Resolution Microcalorimeter Spectrometer, 400 pixels (HERMES-400) is an ultra-high resolution gamma-ray spectrometer at Idaho National Laboratory’s Materials and Fuels Complex. HERMES-400 is intended to enable precise nondestructive analysis of advanced fuel cycle materials. Key upgrades and repairs of the instrument were performed this year to improve performance. First, the fourth and final microcalorimeter detector module was installed, meeting the milestone for its integration into the system. Operation with all four modules enables higher detector efficiency than any previous microcalorimeter gamma-ray system. Second, a thinner magnetic shield was installed. This shields the sensitive microcalorimeter pixels from stray magnetic fields while allowing transmission of lower-energy gamma rays, which are important to isotopic analysis. Finally, the cryostat, which provides cooling of the modules to their operating temperature, was found to have a helium coolant leak, which was repaired. HERMES-400 is in a stable state to perform repeated, long-term gamma-ray measurements with good detector efficiency and energy resolution. In FY25, irradiated TRISO fuel and salts from advanced electrochemical recycling techniques are candidates for microcalorimeter measurements. A final upgrade of the magnetic shielding and vibration damping of the system is also planned to maximize the system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters↗

Broadband Fourier-Transform-Detected EPR at W-Band

This manuscript reports development of wideband Fourier transform (FT) electron paramagnetic resonance (EPR) detection capability at the uniquely high frequency of 94 GHz. Here, this technique is based on the HiPER spectrometer developed at the University of St. Andrews, into which we have integrated an arbitrary waveform generator (AWG) that is used to modulate the output from a solid-state multiplier chain prior to amplification, generating up to 1 kW microwave power with 1 GHz bandwidth. Benchmark experiments are presented for a standard TEMPOL radical, which comprises a 500 MHz broad EPR spectrum at 94 GHz. Using a single frequency-swept microwave pulse, efficient inversion of this spectrum is demonstrated, enabling frequency-dependent studies of the magnetization relaxation in the time-domain, again via broadband echo detection. From these measurements, an anisotropy in the spin–lattice relaxation time, T 1 , can be determined with ease for TEMPOL. In addition, we implement the FT detection scheme for multi-dimensional (electron–electron double resonance, or ELDOR) experiments, demonstrating the full capabilities of the HiPER spectrometer. As an example, we present FT-detected version of the ELDOR-detected nuclear magnetic resonance technique for the TEMPOL radical. We also describe potential applications of the new instrumentation for studies of gadolinium qubits.

36 MATERIALS SCIENCE↗

Evaluating the performance of a high resolution SLIM IM module integrated with an Agilent 6560 IM-QTOF MS - CRADA 413 (Final Report)

Developing new technologies that enhance our abilities to identify molecular signatures is important for the health of the public, the environment, and national security. Deploying these novel technologies requires multiple stages of validation and evaluation. This project focused on evaluating a technology developed at PNNL named Structures for Lossless Ion Manipulations (SLIM) in the context of a commercially available ion mobility mass spectrometer instrument from Agilent Technologies. There is a benefit to integrating the recently developed SLIM module into a real-world instrument platform. Data from the combined instrument will provide new standards for characterizing samples using ion mobility. These standards, related to both the drift time of ions and their resulting collisional cross sections (CCS) will be of value in characterizing samples from both humans and environmental samples, such as soil microbiomes. Because no previous instrument has been designed and implemented to simultaneously analyze the same sample in both constant and oscillating drift fields, the project will provide a new research capability that will support research in a wide variety of applications. The evaluation approach included measuring the resolving power, mass range, sensitivity, and accuracy of two SLIM variations (constant and oscillating fields). Although SLIM performed similarly to the commercial instrument in terms of sensitivity, mass range, and accuracy the resolving power of SLIM far exceeded that of the commercially-available instrument. This validation will provide critically useful data to our commercial partners which they can use to reach informed decisions on the advantages of the SLIM technology such as the outstanding performance and the low cost of manufacturing.

42 ENGINEERING↗

Prototype hardware design and testing of the global common module for the global trigger subsystem of the ATLAS phase-II upgrade

We report the High-Luminosity Large Hadron Collider (HL-LHC) will deliver more than ten times the integrated luminosity of the previous runs combined. Meeting its stricter throughput requirements poses new challenges to the Trigger and Data Acquisition (TDAQ) systems of the LHC experiments. Introduced in the framework of the ATLAS experiment’s HL upgrade, the Global Trigger (GT) is a new subsystem which will perform offline-like algorithms on full-granularity calorimeter data. The implementation of the GT’s functionality is firmware-focused and is composed of three layers: multiplexing (or data aggregating), global event processing, and demultiplexing interface to the central trigger processor. Each layer will be composed of several, similar nodes, hosted on replicas of identical hardware, the Global Common Module (GCM), an ATCA front board which is designed to be adopted throughout the entire GT subsystem. This article proceeds from the TWEPP 2021 conference and presents the GCM hardware design, performed in 2020, and focuses on some key results of its extensive testing performed in 2021.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave radiometer, sun-photometer and GNSS multi-comparison of integrated water vapor in Southwestern Europe

This work presents a comparison of integrated water vapor (IWV) data recorded from microwave radiometer (MWR) and sun-photometer (SP) using global navigation satellite system (GNSS) IWV as reference in five mid-latitude sites of Portugal and Spain (2003–2021). A very high correlation is obtained for both instruments (R2 between 0.94 and 0.98), although, while MWR shows a wet bias, SP exhibits a dry one. In addition, a dependence of mean bias error (MBE) and standard deviation (SD) on IWV has been observed, increasing (larger discrepancies) both indices as IWV increases. The solar zenith angle (SZA) dependence is also studied, finding slightly larger discrepancies for the MWR than for SP in comparison with GNSS for very high values of SZA. Finally, a marked seasonal dependence is observed for SP-GNSS differences, modulated by the IWV dependence explained above. In contrast, the seasonal dependence for MWR is quite weaker than it is for SP. Therefore, in spite of the excellent agreement found among the different instruments, it is recommended that: i) the dependence with IWV be studied and corrected to further increase the performance of the instruments, and ii) metadata be used to filter out situations in which the instrument cannot operate properly.

54 ENVIRONMENTAL SCIENCES↗

Creating a Simulation Platform for Research and Development of Advanced Control Methods

Advanced nuclear reactors are essential to meet the changing energy requirements throughout both the United States and the rest of world. In addition to other features, they are designed to enable deployment in remote locations and operate in a fully (or near-fully) autonomous manner, which will require a new control paradigm. To realize autonomously operating reactors, the U.S. Department of Energy’s Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET ASI) program conducts research and development into the enabling technologies and methods needed, including digital twins, machine learning, and risk modeling, in addition to various types of control methods. These technologies and methods are the key foundations needed to achieve fully autonomous systems. To develop and evaluate the technologies and methods necessary for achieving autonomous operations, it is critical to identify a software tool capable of integrating all the required elements. In surveying the available solutions, no software platforms were identified that could accomplish what was needed without introducing drawbacks. This challenge was the motivation for the current effort: to develop a software platform that can seamlessly integrate autonomouscontrol-enabling technologies and methods, allowing for accelerated research and development and transfer of ideas. The resulting platform, known as the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND), is Python-based, and leverages open-source tools to provide flexibility and facilitate building upon prior research. It is designed to enable advanced reactor developers to deploy and test advanced control technologies and methods coupled with their own models, solutions, and hardware. Given the substantial undertaking of developing such a platform, the current effort focused on laying down scalable, flexible software foundations and infrastructure, then demonstrating the platform via a use case. These foundations included developing generic modules, which contain the base variable and system blocks (the information and functional building blocks, respectively, that can be used to design a simulation) and the data handling and storage blocks needed to exchange information between the various blocks; as well as enablingtechnology-specific modules. This platform was evaluated via a use case, which was to simulate and control a process for the Microreactor Automated Control System (MACS) test bed. While MACS is not currently directly coupled to any specific microreactor physics, it was initially developed in concert with the Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor, and so the MARVEL physics are used here. As part of this use case, several enabling-technology-specific blocks within COMMAND were integrated, including a proportional integral derivative (PID) control block, a Reactor Excursion and Leak Analysis Program (RELAP5-3D) block, and an anomaly detection block. The COMMAND software platform was successfully demonstrated to achieve the scalability and flexibility objectives of this effort and will be leveraged by the program’s research efforts to advance state of the art control methodologies towards autonomous operations of advanced reactors. As new use cases are created and implemented, it is anticipated that COMMAND will continue to grow and evolve to meet new requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma

Monolithic, millimeter wave “system-on-chip” technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75–110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. Finally, a significant aspect of imaging measurement is focusing on artificial intelligence for science applications.

47 OTHER INSTRUMENTATION↗

Photon Detection System for DUNE Low-Energy Physics Study and the Demonstration of a Timing Resolution of a Few Nanoseconds Using ProtoDUNE-SP PDS

Photon detection systems (PDS) are an integral part of liquid-argon neutrino detectors. Besides providing the timing information for an event, which is necessary for reconstructing the drift coordinates of ionizing particle tracks, photon detectors can be effectively used for other purposes, including triggering events, background rejection, and calorimetric energy estimation. PDS in particular for the DUNE Far Detector Module 2 is designed to achieve a more extended optical coverage (→4 ) with new-generation large-size PD modules based on the ARAPUCA technology. This will provide enhanced opportunities for the study of low-energy neutrino physics using PDS. The ARAPUCA technology was extensively tested within the ProtoDUNE-SP detector operated at the CERN neutrino platform. Here, we present a study of the timing resolution of ARAPUCA detectors using light emitted from a sample of energetic cosmic ray muons traveling parallel to the PDS. An intrinsic timing resolution in the order of 3 ns is observed for the ARAPUCA detectors. The excellent timing resolution ability of PDS can be exploited for further enhancing physics studies using the DUNE far detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-modality deep learning for pulse prediction in homogeneous nonlinear systems via parametric conversion

In this Letter, we introduce FusionNet, a multi-modality deep learning framework designed to predict and analyze output pulses in high-power rare-earth-doped laser systems driving parametric conversion in homogeneous guided nonlinear media. FusionNet integrates temporal, spectral, and physical experimental conditions to model ultrafast nonlinear phenomena, including parametric nonlinear frequency conversion, self-phase modulation, and cross-phase modulation in homogeneous guided systems such as gas-filled hollow-core fibers. These systems bridge physical models with experimental data, advancing our understanding of light-guiding principles and nonlinear interactions while expediting the design and optimization of on-demand high-power, high-brightness systems. Our results demonstrate a 73% reduction in prediction error and an 83% improvement in computational efficiency compared to conventional neural networks. This work establishes a new paradigm for accelerating parametric simulations and optimizing experimental designs in high-power laser systems, with further implications for high-precision spectroscopy, quantum information science, and distributed entangled interconnects.

47 OTHER INSTRUMENTATION↗

Spin-textured neutron beams with orbital angular momentum

In this work, we present a rigorous theoretical framework underpinning the technique of spin-echo modulated small-angle neutron scattering (SEMSANS), and show how the technique can be extended in order to generate spin-textured neutron beams with orbital angular momentum (OAM) via birefringent neutron spin-polarization devices known as magnetic Wollaston prisms. Neutron OAM beams are mathematically characterized by a “cork-screw” phase singularity e iℓΦ about the propagation axis where ℓ is the OAM quantum number. To understand the precise relationship between the emergent OAM state and the variety of spin textures realized by various setups, we have developed a path-integral approach that in the interferometric limit makes a judicious use of magnetic Snell's law. We show that our proposed technique produces a complex two-dimensional pattern of spin-OAM entangled states which may be useful as a probe of quantum magnetic materials. We compare our path-integral approach to the well-known single-path Larmor precession model and present a pedagogical derivation of magnetic Snell's law of refraction for both massive and massless particles based on Maupertuis's action principle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining the tilt of the Raman laser beam using an optical method for atom gravimeters

The tilt of a Raman laser beam is a major systematic error in precision gravity measurement using atom interferometry. The conventional approach to evaluating this tilt error involves modulating the direction of the Raman laser beam and conducting time-consuming gravity measurements to identify the error minimum. In this work, we demonstrate a method to expediently determine the tilt of the Raman laser beam by transforming the tilt angle measurement into characterization of parallelism, which integrates the optical method of aligning the laser direction, commonly used in freely falling corner-cube gravimeters, into an atom gravimeter. A position-sensing detector (PSD) is utilized to quantitatively characterize the parallelism between the test beam and the reference beam, thus measuring the tilt precisely and rapidly. After carefully positioning the PSD and calibrating the relationship between the distance measured by the PSD and the tilt angle measured by the tiltmeter, we achieved a statistical uncertainty of less than 30 µrad in the tilt measurement. Furthermore, we compared the results obtained through this optical method with those from the conventional tilt modulation method for gravity measurement. The comparison validates that our optical method can achieve tilt determination with an accuracy level of better than 200 µrad, corresponding to a systematic error of 20 µGal in g measurement. This work has practical implications for real-world applications of atom gravimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multichannel Silicon Package for Large-Scale Skipper-CCD Experiments

The next generation of experiments for light-dark-matter and neutrino searches based on skipper charge-coupled devices (skipper-CCDs) introduces new challenges for the sensor packaging and readout architecture. Scaling the active mass while simultaneously reducing the experimental backgrounds in orders of magnitude requires a novel high-density silicon-based package that must be massively produced and tested. In this work, we present a silicon multichip module design capable of hosting up to 16 skipper-CCDs, along with the fabrication process for the first prototypes. We thoroughly tested and characterized the assembled prototypes to build an empirical model for the video output signal of skipper-CCDs integrated into the silicon package. We then used this model in simulations to optimize the fabrication process and achieve the robust performance required for the full-scale array, which we validated through a new round of prototype fabrication. We outline the specifications selected for the ongoing production of 1500 silicon wafers that will ultimately add up to a 10-kg skipper-CCD array with 24000 readout channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-throughput feedback-enabled optogenetic stimulation and spectroscopy in microwell plates

Abstract The ability to perform sophisticated, high-throughput optogenetic experiments has been greatly enhanced by recent open-source illumination devices that allow independent programming of light patterns in single wells of microwell plates. However, there is currently a lack of instrumentation to monitor such experiments in real time, necessitating repeated transfers of the samples to stand-alone analytical instruments, thus limiting the types of experiments that could be performed. Here we address this gap with the development of the optoPlateReader (oPR), an open-source, solid-state, compact device that allows automated optogenetic stimulation and spectroscopy in each well of a 96-well plate. The oPR integrates an optoPlate illumination module with a module called the optoReader, an array of 96 photodiodes and LEDs that allows 96 parallel light measurements. The oPR was optimized for stimulation with blue light and for measurements of optical density and fluorescence. After calibration of all device components, we used the oPR to measure growth and to induce and measure fluorescent protein expression in E. coli . We further demonstrated how the optical read/write capabilities of the oPR permit computer-in-the-loop feedback control, where the current state of the sample can be used to adjust the optical stimulation parameters of the sample according to pre-defined feedback algorithms. The oPR will thus help realize an untapped potential for optogenetic experiments by enabling automated reading, writing, and feedback in microwell plates through open-source hardware that is accessible, customizable, and inexpensive.

59 BASIC BIOLOGICAL SCIENCES↗

A New Concept for Kilotonne Scale Liquid Argon Time Projection Chambers

We develop a novel Time Projection Chamber (TPC) concept suitable for deployment in kilotonne-scale detectors, with a charge-readout system free from reconstruction ambiguities, and a robust TPC design that reduces high-voltage risks while increasing the coverage of the light-collection system and maximizing the active volume. This novel concept could be used as a far detector module in the Deep Underground Neutrino Experiment (DUNE). For the charge-readout system, we used the charge-collection pixels and associated application-specific integrated circuits currently being developed for the liquid argon (LAr) component of the DUNE Near Detector design, ArgonCube. In addition, we divided the TPC into a number of shorter drift volumes, reducing the total voltage used to drift the ionization electrons, and minimizing the stored energy per TPC. Segmenting the TPC also contains scintillation light, allowing for precise trigger localization and a more expansive light-readout system. Furthermore, the design opens the possibility of replacing or upgrading components. These augmentations could substantially improve the reliability and the sensitivity, particularly for low-energy signals, in comparison to traditional monolithic LArTPCs with projective-wire charge readouts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗