At least 37 records · Page 2

Advanced Distributed Optical Fiber Sensor Systems for Pipeline Integrity Monitoring

Distributed fiber optic sensors allow the measurement of structural parameters such as static/dynamic strain, temperature, pressure, and vibrations at thousands of locations along a single fiber cable. Deep neural network (DNN) algorithms were developed for rapid data processing speed and vibration event classification.

Lalam, Nageswara↗

Fiber-Optic Defect and Damage Locator System for Wind Turbine Blades

IFOS in collaboration with Auburn University demonstrated the feasibility of a Fiber Bragg Grating (FBG) integrated sensor system capable of providing real time in-situ defect detection, localization and quantification of damage. In addition, the system is capable of validating wind turbine blade structural models, using recent advances in non-contact, non-destructive dynamic testing of composite structures. This new generation method makes it possible to analyze wind turbine blades not only non-destructively, but also without physically contacting or implanting intrusive electrical elements and transducers into the structure. Phase I successfully demonstrated the feasibility of the technology with the construction of a 1.5 kHz sensor interrogator and preliminary instrumentation and testing of both composite material coupons and a wind turbine blade.

17 WIND ENERGY↗

Wireless Integrated Microelectronic Vacuum Sensor System

NASA Stennis Space Center's (SSC's) large rocket engine test facility requires the use of liquid propellants, including the use of cryogenic fluids like liquid hydrogen as fuel, and liquid oxygen as an oxidizer (gases which have been liquefied at very low temperatures). These fluids require special handling, storage, and transfer technology. The biggest problem associated with transferring cryogenic liquids is product loss due to heat transfer. Vacuum jacketed piping is specifically designed to maintain high thermal efficiency so that cryogenic liquids can be transferred with minimal heat transfer. A vacuum jacketed pipe is essentially two pipes in one. There is an inner carrier pipe, in which the cryogenic liquid is actually transferred, and an outer jacket pipe that supports and seals the vacuum insulation, forming the "vacuum jacket." The integrity of the vacuum jacketed transmission lines that transfer the cryogenic fluid from delivery barges to the test stand must be maintained prior to and during engine testing. To monitor the vacuum in these vacuum jacketed transmission lines, vacuum gauge readings are used. At SSC, vacuum gauge measurements are done on a manual rotation basis with two technicians, each using a handheld instrument. Manual collection of vacuum data is labor intensive and uses valuable personnel time. Additionally, there are times when personnel cannot collect the data in a timely fashion (i.e., when a leak is detected, measurements must be taken more often). Additionally, distribution of this data to all interested parties can be cumbersome. To simplify the vacuum-gauge data collection process, automate the data collection, and decrease the labor costs associated with acquiring these measurements, an automated system that monitors the existing gauges was developed by Invocon, Inc. For this project, Invocon developed a Wireless Integrated Microelectronic Vacuum Sensor System (WIMVSS) that provides the ability to gather vacuum-gauge measurements automatically and wirelessly, in near-real time - using a low-maintenance, lowpower sensor mesh network. The WIMVSS operates by using a self-configuring mesh network of wireless sensor units. Mesh networking is a type of networking where each sensor or node can capture and disseminate its own data, but also serve as a relay to receive and transmit data from other sensors. Each sensor node can synchronize with adjacent sensors, and propagate data from one sensor to the next, until the destination is reached. In this case, the destination is a Network Interface Unit (NIU). The WIMVSS sensors are mounted on the existing vacuum gauges. Information gathered by the sensors is sent to the NIU. Because of the mesh networking, if a sensor cannot directly send the data to the NIU, it can be propagated through the network of sensors. The NIU requires antenna access to the sensor units, AC power, and an Ethernet connection. The NIU bridges the sensor network to a WIMVSS server via an Ethernet connection. The server is configured with a database, a Web server, and proprietary interface software that makes it possible for the vacuum measurements from vacuum jacketed fluid lines to be saved, retrieved, and then displayed from any Web-enabled PC that has access to the Internet. Authorized users can then simply access the data from any PC with Internet connection. Commands can also be sent directly from the Web interface for control and maintenance of the sensor network. The technology enabled by the WIMVSS decreases labor required for gathering vacuum measurements, increases access to vacuum data by making it available on any computer with access to the Internet, increases the frequency with which data points can be acquired for evaluating the system, and decreases the recurring cost of the sensors by using off-the-shelf components and integrating these with heritage vacuum gauges.

Krug, Eric↗

Inertial navigation sensor integrated obstacle detection system

A system that incorporates inertial sensor information into optical flow computations to detect obstacles and to provide alternative navigational paths free from obstacles. The system is a maximally passive obstacle detection system that makes selective use of an active sensor. The active detection typically utilizes a laser. Passive sensor suite includes binocular stereo, motion stereo and variable fields-of-view. Optical flow computations involve extraction, derotation and matching of interest points from sequential frames of imagery, for range interpolation of the sensed scene, which in turn provides obstacle information for purposes of safe navigation.

Bhanu, Bir↗

Sensor Integrated Pilot Mask for On-Board, Real-Time, Monitoring of Pilot Breathing Gas

A pilot's job is unique in the demands it places on the human body, and many conditions can seriously affect pilot performance, threatening mission completion and pilot safety. The gas in a flight mask contains key indicators of the pilot's physiological state, including oxygen inhaled and carbon dioxide exhaled, which can signal hypoxia, hyperoxia, hypocapnia, and hypercapnia. A fiber optic-based sensor system, integrated into the pilot mask, has been developed to monitor in real time, during flight, the pilot breathing gas levels. Monitoring the partial pressure of oxygen and carbon dioxide in the pilot mask supports real-time closed loop control of the on-board oxygen generation system, based on a direct reading of what the pilot is actually breathing. The pilot Mask Sensor (MASES) system incorporates luminescence sensors for pO2, pCO2, relative humidity, pressure, and temperature in a compact probe in the pilot mask; it is based on sensor technology developed for gas monitoring in space suit systems, in work supported by NASA under the Small Business Innovation Research program. Relevant requirements for the MASES system include sensor operation while wet, operation at reduced pressure, ability to withstand rapid decompression, operation in a pure oxygen atmosphere, low power consumption, a compact readout unit, and flexible miniature sensors; many of these requirements are shared with gas monitors in space suits. Data are presented from tests conducted with human subjects in an altitude chamber and in a centrifuge.

Delgado Alonso, Jesus↗

Nondestructive Modular Leak Detection in 3D Printed 316L Stainless Steel Pipes via Laser Powder Bed Fusion

This research investigates the leak detection features of 316L Stainless Steel pipe structures manufactured via Laser Powder Bed Fusion (LPBF). This work involves the design of a modular sensor system integrating nondestructive evaluation (NDE) methods, including thermal imaging and ultrasonic frequency detection to detect and characterize leaks in components. This aims to improve leak detection sensitivity within medium-pressure gas systems, during continuous operation without halting flow or introducing safety risks. The system could be adaptable for use on unmanned aerial vehicles (UAVs), enabling remote leak detection in active environments. A custom pneumatic system incorporating temperature and pressure sensors was assembled to detect leaks in LPBF-printed 316L SS tee pipes. Experimental results and simulations confirm the system’s effectiveness in leak detection and material evaluation. This research program also integrated a Python-based image recognition platform based on a metallography and optical microscopy to assess the porosity and complement the leak detection data on the printed structures. This allows a detailed analysis of pore distribution and internal leak paths, which could compromise structural integrity, critical for quality control during manufacturing. Findings suggest that the investigated approach holds potential for enhancing leak detection technologies and adapt them for advanced manufactured parts.

36 MATERIALS SCIENCE↗

Laboratory testing methods to evaluate the reliability of occupancy sensors for commercial building applications

The energy performance of commercial buildings is greatly influenced by occupants which are highly variable and among the most unpredictable components of a building's operation. While most building control systems use fixed, predetermined occupancy schedules, these fixed occupancy levels can be quite different from actual occupancy. This can cause unnecessary energy consumption, particularly from heating, ventilation, and air conditioning (HVAC) and lighting systems which are responsible for approximately 60% of commercial buildings' energy use. The use of occupancy counting sensor systems integrated with building management system controls is one method that can be used to improve the energy-consuming performance of buildings. However, there is no standardized universal methodology and metrics to evaluate their reliability. The aim of this research is to develop a uniform evaluation methodology to assess the reliability of occupancy counting sensor systems in a controlled laboratory environment. The developed testing methodology includes both “typical” scenarios representing the occupancy scenarios of a typical commercial building, and “failure” testing scenarios which represent a range of potential scenarios that may impact a sensor system's reliability. These methods were then implemented in a case study to evaluate the performance of two novel occupancy counting sensor systems (i.e., door-centric, and camera-based). Results suggest that typical testing results can be used to compare the overall performance of the occupancy counting sensor systems; however, failure testing is also important to understand the weaknesses of the sensor system in order to select the suitable one for the intended use of the commercial building. In addition, the proposed methodology includes a modified confusion matrix which enables the ability to identify if failures are caused by over or under counting occupants and to what extent this occurs over the testing period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of SMART sensor displays for multidimensional precision control of Space Shuttle remote manipulator

An enhanced proximity sensor and display system was developed at the Jet Propulsion Laboratory (JPL) and tested on the full scale Space Shuttle Remote Manipulator at the Johnson Space Center (JSC) Manipulator Development Facility (MDF). The sensor system, integrated with a four-claw end effector, measures range error up to 6 inches, and pitch and yaw alignment errors within + or 15 deg., and displays error data on both graphic and numeric displays. The errors are referenced to the end effector control axes through appropriate data processing by a dedicated microcomputer acting on the sensor data in real time. Both display boxes contain a green lamp which indicates whether the combination of range, pitch and yaw errors will assure a successful grapple. More than 200 test runs were completed in early 1980 by three operators at JSC for grasping static and capturing slowly moving targets. The tests have indicated that the use of graphic/numeric displays of proximity sensor information improves precision control of grasp/capture range by more than a factor of two for both static and dynamic grapple conditions.

Bejczy, A. K.↗

MO-FG-303-02: BEST IN PHYSICS (THERAPY): Cherenkov Emission Dosimetry: Feasibility for Electron Radiotherapy

Purpose: To investigate from first principles, corroborated by Monte Carlo simulations and experimental measurements, the feasibility of developing a relative Cherenkov emission (CE) dosimetry protocol for electron beam radiotherapy. Methods: Monte Carlo (MC) simulations of mono-energetic electrons incident on water were carried out in Geant4. Percent depth Cherenkov emission (PDCE) and dose (PDD) distributions were scored for incidence energies of 4, 6, 9, 12, 15, and 18 MeV. PDCE-to-PDD analytical conversion models were developed from least-squares data fits generated for PDD as a function of PDCE at the same depth and at different depths. Experimental techniques for validation of these models are examined. Results: Same-depth PDD versus PDCE data fits indicate that although the relationship is linear to first order (correlation r > 0.9 for all energies), it is much more accurately approximated by separate linear and quadratic models for the build-up and drop-off regions, respectively (r > 0.999), which is theoretically underpinned. To understand the source of this relationship and its basis for developing robust conversion models, an approximate quadratic first-principles model was derived and found in agreement with MC/measured data (20% deviation at worst). Conversely, data fits of PDD versus different-depth PDCE unveiled a depth-invariant effective point of measurement of 1.5–2.1 mm downstream with 4–18 MeV incidence, respectively (r > 0.999 in the drop-off region). We present an analytical first-principles justification for this shift. This method led to errors of <1% in drop-off region PDD (<2% for PDD<20% with 4 MeV incidence) and <0.2 mm in practical range prediction. Conclusion: We present robust quantitative prediction models, derived from first-principles and supported by simulation and measurement, for relative dose from Cherenkov emission by high-energy electrons. This constitutes a major step towards development of protocols for routine clinical quality assurance as well as real-time in vivo Cherenkov dosimetry in radiotherapy. The authors acknowledge partial support by Fonds de recherche du Quebec - Nature et technologies (FRQNT), CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council of Canada (NSERC), CREATE Integrated Sensor Systems grant of NSERC, the Canadian Institutes of Health Research (CIHR), and NSERC.

60 APPLIED LIFE SCIENCES↗

Multifunctional Integrated Sensors (MFISES)

Many emerging IoT applications require sensing of multiple physical and environmental parameters for: completeness of information, measurement validation, unexpected demands, improved performance. For example, a typical outdoor weather station measures temperature, humidity, barometric pressure, light intensity, rainfall, wind speed and direction. Existing sensor technologies do not directly address the demand for cost, size, and power reduction in multi-paramater sensing applications. Industry sensor manufacturers have developed integrated sensor systems for inertial measurements that combine accelerometers, gyroscopes, and magnetometers, but do not address environmental sensing functionality. In existing research literature, a technology gap exists between the functionality of MEMS sensors and the real world applications of the sensors systems.

42 ENGINEERING↗

Optimum satellite orbits for accurate measurement of the earth's radiation budget, summary

The optimum set of orbit inclinations for the measurement of the earth radiation budget from spacially integrating sensor systems was estimated for two and three satellite systems. The best set of the two were satellites at orbit inclinations of 80 deg and 50 deg; of three the inclinations were 80 deg, 60 deg and 50 deg. These were chosen on the basis of a simulation of flat plate and spherical detectors flying over a daily varying earth radiation field as measured by the Nimbus 3 medium resolution scanners. A diurnal oscillation was also included in the emitted flux and albedo to give a source field as realistic as possible. Twenty three satellites with different inclinations and equator crossings were simulated, allowing the results of thousand of multisatellite sets to be intercompared. All were circular orbits of radius 7178 kilometers.

Campbell, G. G.↗

Integrating Low-Cost Sensor Systems and Networks to Enhance Air Quality Applications

Recent advances in low-cost air quality sensor systems are rapidly increasing the accessibility of air quality information around the world. At the same time, there are many technical challenges to appropriately and effectively using of the information they provide. A key opportunity to increase the applicability and actionability of low-cost sensor data is to use these devices at network scale and combine their information with insights from other air quality data sources such as numerical models and satellite remote sensing. When the limitations of low-cost sensors are understood and acknowledged, and appropriate complementary data are used to overcome these limitations, low cost sensors can support a variety of applications such as improving location-specific air quality forecasting and estimation, quantifying local source impacts, identifying air quality disparities, assessing the benefits of mitigation actions, and promoting community engagement with air quality issues. This presentation will first provide an overview and summarize key findings from a recently released World Meteorological Organization report discussing how networks of low-cost air quality sensor systems can be integrated to effectively support such applications. The presentation will also give a brief overview of an ongoing NASA-funded effort to create accessible tools for integrating multiple sources of air quality information, including global forecasting models, satellite remote sensing data, and in-situ information from both regulatory and low-cost monitors.

Carl Malings↗

Smart Sensors' Role in Integrated System Health Management

During the last decade, there has been a major effort in the aerospace industry to reduce the cost per pond of payload and become competitive in the international market. Competition from Europe, Japan, and China has reduced this cost to almost a third from 1990 to 2000. This cost has leveled in recent years to an average price of around $12,000/pound of payload. One of NASA's goals is to promote the development of technologies to reduce this cost by a factor of 10 or more Exploration of space, specially manned exploration missions, involves very complex launch and flight vehicles, associated ground support systems, and extensive human support during all phases of the mission. When considering the Space Shuttle Program, we can see that vehicle and ground support systems' processing, operation, and maintenance represent a large percentage of the program cost and time. Reducing operating, processing and maintenance costs will greatly reduce the cost of Exploration programs. The Integrated System Health Management (ISHM) concept is one of the technologies that will help reduce these operating, processing and maintenance costs. ISHM is an integrated health monitoring system applicable to both flight and ground systems. It automatically and autonomously acquires information from sensors and actuators and processes that information using the ISHM-embedded knowledge. As a result, it establishes the health of the system based on the acquired information and its prior knowledge. When this concept is fully implemented, ISHM systems shall be able to perform failure prediction and remediation before actual hard failures occurs, preventing its costly consequences. Data sources, sensors, and their associated data acquisition systems, constitute the foundation of the system. A smart sensing architecture is required to support the acquisition of reliable, high quality data, required by the ISHM. A thorough definition of the smart sensor architectures, their embedded diagnostic agents, and communication protocols need to be established and standardized to allow the embedding and exchange of health information among sensors and ISHM. This workshop is aimed to foster the exchange of ideas and lessons learned between government, industry and academia to aid in the establishment of ISHM (and smart sensors) standards and guidelines as well as to identify present technology gaps that will have to be overcome to successfully achieve this goal.

Perotti, Jose M.↗

An Integrated MEMS Sensor Cluster System for Aerospace Applications

Efforts to reduce viscous drag on airfoils could results in a considerable saving for the operation of flight vehicles including those of space transportation. This reduction of viscous drag effort requires measurement and active control of boundary layer flow property on an airfoil. Measurement of viscous drag of the boundary layer flow over an airfoil with minimal flow disturbance is achievable with newly developed MEMS sensor clusters. These sensor clusters provide information that can be used to actively control actuators to obtain desired flow properties or design a vehicle to satisfy particular boundary layer flow criteria. A series of MEMS sensor clusters has been developed with a data acquisition and control module for local measurements of shear stress, pressure, and temperature on an airfoil. The sensor cluster consists of two shear stress sensors, two pressure sensors, and two temperature sensors on a surface area of 1.24 mm x 1.86 mm. Each sensor is 300 microns square and is placed on a flexible polyimide sheet. The shear stress sensor is a polysilicon hot-film resistor, which is insulated by a vacuum cavity of 200 x 200 x 2 microns. The pressure sensors are silicon piezoresistive type, and the temperature sensors are also hot film polysilicon resistors. The total size of the cluster including sensors and electrical leads is 1 Omm x 1 Omm x 0.1 mm. A typical sensitivity of shear stress sensor is 150 mV/Pascal, the pressure sensors are an absolute type with a measurement range from 9 to 36 psia with 0.8mV/V/psi sensitivity, and the temperature sensors have a measurement resolution of 0.1 degree C. The sensor clusters are interfaced to a data acquisition and control module that consists of two custom ASICs (Application Specific Integrated Circuits) and a micro-controller. The data acquisition and control module transfers data to a host PC that configures and controls a total of three sensor clusters. Functionality of the entire system has been tested in the laboratory, and preliminary test results are presented.

Kahng, Seun↗

A Fault Tolerant System for an Integrated Avionics Sensor Configuration

An aircraft sensor fault tolerant system methodology for the Transport Systems Research Vehicle in a Microwave Landing System (MLS) environment is described. The fault tolerant system provides reliable estimates in the presence of possible failures both in ground-based navigation aids, and in on-board flight control and inertial sensors. Sensor failures are identified by utilizing the analytic relationships between the various sensors arising from the aircraft point mass equations of motion. The estimation and failure detection performance of the software implementation (called FINDS) of the developed system was analyzed on a nonlinear digital simulation of the research aircraft. Simulation results showing the detection performance of FINDS, using a dual redundant sensor compliment, are presented for bias, hardover, null, ramp, increased noise and scale factor failures. In general, the results show that FINDS can distinguish between normal operating sensor errors and failures while providing an excellent detection speed for bias failures in the MLS, indicated airspeed, attitude and radar altimeter sensors.

Caglayan, A. K.↗