Search NASA⌕ Search

SEARCH · Search NASA

Results for “Intercalibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Spectral Gap Filling Method Using the Spectral Information from CLARREO-Pathfinder Measured Earth-Reflected Solar Spectra to Support CPF-CERES Intercalibration

The high-accuracy Earth-reflected solar spectral radiances from CLARREO Pathfinder (CPF) will serve as in-orbit benchmark measurements for intercalibrating other satellite imagers. The CPF team is developing a state-of-the-art intercalibration method to calibrate the shortwave channel (300-5000 nm) of the CERES instrument against the CPF reference with an uncertainty of 0.3%. Because the CPF instrument only covers spectral range from 350 nm to 2300 nm, the team has developed a spectral extension method to fill in the gaps between the spectral domains of CPF and the CERES shortwave channel. The method solely relies on using the hyperspectral information from the CPF wavelengths to predict the radiances below 350 nm and above 2300 nm. To quantify the relationship between the CPF spectrum and the non-overlapping portions of the spectrum between CPF and CERES, the team has simulated a large ensemble of spectra that cover the spectral range for both CPF and CERES. A hyperspectral bidirectional reflectance model for land surface based on thousands of measured land surface reflectance has been developed. This land surface model as well as the Cox-Munk model for ocean surface are used in the spectral gap filling. Various water/ice clouds, aerosols, atmosphere profiles and surfaces were used to simulate Earth-reflected radiances from 200 nm to 15 um under different solar and sensor geometries. The targeted uncertainty for the CPF-extended broadband CERES radiances is less than 0.1%. The previously derived training spectra were updated to replace the Kurucz solar irradiance model with the TSIS-1 Hybrid Solar Reference Spectrum. The influence of the scalar assumption in radiative transfer model equations on the uncertainty in estimating the broadband radiances was also investigated.

Hyperspectral↗

Volume 14: The first SeaWiFS intercalibration round-robin experiment, SIRREX-1, July 1992

The results of the first Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-1), which was held at the Center for Hydro-Optics and Remote Sensing (CHORS) at San Diego State University (SDSU) on 27-31 July 1992 are presetend. Oceanographic radiometers to be used in the SeaWiFS Calibration and Validation Program will be calibrated by individuals from the National Aeronautics and Space Administration's (NASA's) Goddard Space Flight Center (GSFC), CHORS, and seven other laboratories. The purpose of the SIRREX experiments is to assure the radiometric standards used in all of these laboratories are referenced to the same scales of spectral irradiance and radiance, which will be maintained by GSFC and periodically recalibrated by the National Institute of Standards and Technology (NIST). The spectral irradiance scale of GSFC's FEL lamp number F269 (recalibrated by NIST in October 1992) was transferred to lamps belonging to the 9 participating laboratories; l set of lamp transfer measurements (involving 4 of the lamps) was precise to within less than 1 percent and meets SeaWiFS goals, but a second set (involving another 14 lamps) did not. The spectral radiance scale of the GSFC 40-inch integrating sphere source was transferred to integrating sphere radiance sources belonging to four of the other laboratories. Reflectance plaques, used for irradiance-to-radiance transfer by five of the laboratories, were compared, but spectral bidirectional reflectance distribution functions (BRDF's) were not determined quantitatively. Also reported are results of similar comparisons (in October 1992) between the GSFC scales of spectral irradiance and radiance and those used by the Hughes/Santa Barbara Research Center (SBRC) to calibrate and characterize the SeaWiFS instrument. This first set of intercalibration round-robin experiments was a valuable learning experience for all participants, and led to several important procedural changes, which will be implemented in the second SIRREX, to be held at CHORS in June 1993.

Mueller, James L.↗

Comparing the Ocean Color Measurements Between MOS and SeaWiFS: A Vicarious Intercalibration Approach for MOS

One of the primary goals of the NASA Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) project is to develop methods for meaningful comparison and possible merging of data products from multiple ocean color missions. The Modular Optoelectronic Scanner (MOS) is a German instrument that was launched in the spring of 1996 on the Indian IRS-P3 satellite. With the successful launch of NASA's Sea-viewing Wide Field-of-view Sensor (SeaWiFS) in the summer of 1997, there are now two ocean color missions in concurrent operation and there is interest within the scientific community to compare data from these two sensors. In this paper, we describe our efforts to retrieve ocean optical properties from both SeaWiFS and MOS using consistent methods. We first briefly review the atmospheric correction, which removes more than 90% of the observed radiances in the visible, and then describe how the atmospheric correction algorithm used for the SeaWiFS data can be modified for application to other ocean color sensors. Next, since the retrieved water-leaving radiances in the visible between MOS and SeaWiFS are significantly different, we developed a vicarious intercalibration method to recalibrate the MOS spectral bands based on the optical properties of the ocean and atmosphere derived from the coincident SeaWiFS measurements. We present and discuss the MOS retrieved ocean optical properties before and after the vicarious calibration, and demonstrate the efficacy of this approach. We show that it is possible and efficient to vicariously intercalibrate sensors between one and another.

Wang, Menghua↗

GPM Plans for Radiometer Intercalibration

The international Global Precipitation Measurement (GPM) mission led by NASA and JAXA is planned as a multi-radiometer constellation mission. A key mission component is the ability to intercalibrate the Tb from the partner constellation radiometers and create inter-calibrated, mission consistent Tc. One of the enabling strategies for this approach is the launching of a joint NASA/JAXA core satellite which contains a JAXA/NICT provided dual precipitation radar and a NASA provided Microwave Imaging passive radiometer. The observations from these instruments on the core satellite provide the opportunity to develop a transfer reference standard that can then be applied across the partner provided constellation radiometers that enables the creation of mission consistent brightness temperatures. The other aspect of the strategy is the development of a community consensus intercalibration algorithm that will be applied to the Tb observations from partner radiometers and create the best calibrated Tc. Also described is the development of the framework in which the inter-calibration is included in the final algorithm. A part of the latter effort has been the development of a generic, logical structure which can be applied across radiometer types and which guarantees the user community that key information for using Tc properly is recorded. Key

Stocker, Erich Franz↗

STEREO SECCHI COR1-A/B Intercalibration at 180 deg Separation

The twin Solar Terrestrial Relations Observatory (STEREO) spacecraft reached a separation angle of 180 degrees on 6 February 2011. This provided a unique opportunity to test the intercalibration between the Sun-Earth Connection Coronal and Heliospheric Investigation (SECCHI) telescopes on both spacecraft for areas above the limb. So long as the corona is optically thin, at 180 degree separation each spacecraft sees the same corona from opposite directions. Thus, the data should appear as mirror images of each other. We report here on the results of the comparison of the images taken by the inner coronagraph (COR1) on the STEREO Ahead and Behind spacecraft in the hours when the separation was close to 180 degrees. We find that the intensity values seen by the two telescopes agree with each other to a high degree of accuracy. This validates both the radiometric intercalibration between the COR1 telescopes, and the method used to remove instrumental background from the images. The relative error between COR1-A and COR1-B is found to be less than 10(exp -9) B/B solar over most of the field-of-view, growing to a few x 10(exp -9) B/B solar for the brighter pixels near the edge of the occulter. The primary source of error is the background determination. We also report on the analysis of star observations which show that the absolute radiometric calibration of either COR1 telescope has not changed significantly since launch.

Thompson, W. T.↗

STEREO SECCHI COR1-A/B Intercalibration at 180 deg Separation

The twin Solar Terrestrial Relations Observatory (STEREO) spacecraft reached a separation angle of 180 deg on 6 February 2011. This provided a unique opportunity to test the intercalibration between the Sun-Earth Connection Coronal and Heliospheric Investigation (SECCHI) telescopes on both spacecraft for areas above the limb. So long as the corona is optically thin, at 180 deg separation each spacecraft sees the same corona from opposite directions. Thus, the data should appear as mirror images of each other. We report here on the results of the comparison of the images taken by the inner coronagraph (COR1) on the STEREO-Ahead and -Behind spacecraft in the hours when the separation was close to 180 deg. We find that the intensity values seen by the two telescopes agree with each other to a high degree of accuracy. This validates both the radiometric intercalibration between the COR1 telescopes, and the method used to remove instrumental background from the images. The relative error between COR1-A and COR1-B is found to be less than 10-9 B/B over most of the field-of-view, growing to a few 10-9 B/B for the brighter pixels near the edge of the occulter. The primary source of error is the background determination. We also report on the analysis of star observations which show that the absolute radiometric calibration of either COR1 telescope has not changed significantly since launch.

Thompson, W. T.↗

Opportunities to Intercalibrate Radiometric Sensors From International Space Station

Highly accurate measurements of Earth's thermal infrared and reflected solar radiation are required for detecting and predicting long-term climate change. We consider the concept of using the International Space Station to test instruments and techniques that would eventually be used on a dedicated mission such as the Climate Absolute Radiance and Refractivity Observatory. In particular, a quantitative investigation is performed to determine whether it is possible to use measurements obtained with a highly accurate reflected solar radiation spectrometer to calibrate similar, less accurate instruments in other low Earth orbits. Estimates of numbers of samples useful for intercalibration are made with the aid of year-long simulations of orbital motion. We conclude that the International Space Station orbit is ideally suited for the purpose of intercalibration.

Roithmayr, C. M.↗

CEOS Visualization Environment (COVE) Tool for Intercalibration of Satellite Instruments

Increasingly, data from multiple instruments are used to gain a more complete understanding of land surface processes at a variety of scales. Intercalibration, comparison, and coordination of satellite instrument coverage areas is a critical effort of space agencies and of international and domestic organizations. The Committee on Earth Observation Satellites Visualization Environment (COVE) is a suite of browser-based applications that leverage Google Earth to display past, present, and future satellite instrument coverage areas and coincident calibration opportunities. This forecasting and ground coverage analysis and visualization capability greatly benefits the remote sensing calibration community in preparation for multisatellite ground calibration campaigns or individual satellite calibration studies. COVE has been developed for use by a broad international community to improve the efficiency and efficacy of such calibration efforts. This paper provides a brief overview of the COVE tool, its validation, accuracies and limitations with emphasis on the applicability of this visualization tool for supporting ground field campaigns and intercalibration of satellite instruments.

Kessler, Paul D.↗

Intercalibration of AMSR2 NASA Team 2 Algorithm Sea Ice Concentrations with AMSR-E Slow Rotation Data

Sea ice estimates from AMSR2 are intercalibrated with AMSR-E fields through a two-step process. First, slow rotation 2 r/min AMSR-E data is used to derive regression equations from colocated pairs of AMSR2 and AMSR-E brightness temperatures (Tb s). The regression equations are used to modify AMSR2 Tb s into AMSR-E equivalent Tb s that are then input into the NASA Team 2 (NT2) sea ice concentration algorithm used for the AMSR-E standard products. The regressed Tb s result in changes in sea ice concentration of a few percent compared to using the original un-regressed AMSR2 Tb s. Next, sea ice estimates from the F17 SSMIS sensor are used as a bridge to compare AMSR-E total sea ice extent estimates in 2010 with AMSR2 total sea ice extent estimates in 2013. Based on this comparison, a further adjustment is made to a weather filter threshold used in the NT2 algorithm to minimize the total extent bias between AMSR2 and AMSR-E using a double-differencing approach. The adjustments reduced apparent bias with AMSR-E from 200 000 km2 for the original unmodified AMSR2 Tb s to –700 and 4700 km2 for the Arctic and Antarctic, respectively. These differences are within the range of previous passive microwave sea ice intercalibrations. The adjusted AMSR2 sea ice fields provide a nearly 15-year time series of sea ice change; depending on the lifetime of AMSR2 and possible follow on sensors, AMSR2 has the potential to be part of a multidecadal record of sea ice change.

remote sensing↗

Comments on the intercalibration of multisensor, multitemporal, multichannel digital radiance data

When comparing the recorded radiance data obtained on a given date by means of different sensors or on different dates using the same sensor, the values in question must be referred to some common datum. It is presently noted that more data are required for remote sensing instruments, and that these should consist of gain, offset, spectral response and point spread function for each bandpass. Such information will be the bases for studies of sensor intercalibration procedure.

Duggin, M. J.↗

Intercalibration of the hard X-ray spectrometers on the PVO and ICE (ISEE-3) spacecraft

The energetic photon spectrometers aboard the ICE and PVO (Pioneer Venus Orbiter) are described briefly, and the procedure for their in-flight calibrations is discussed. Successful intercalibration of these two instruments led to stereoscopic observations of 100 keV-2 MeV photon sources in solar flares and the study of the directivity and height structure of these sources. The impulsive hard X-ray source is found to extend from the chromosphere to the corona, the brightness of the source decreasing rapidly with increase in height above the chromosphere. The analysis so far indicates no systematic directivity for the hard X-ray source. The observations are consistent with energetic electrons accelerated in the corona propagating downward toward the chromosphere. However, when avaraged over the duration of an impulsive hard X-ray flare, the 'beaming' of electrons is found to be small in most flares.

Kane, S. R.↗

LASSO experiment: Intercalibrations of the LASSO ranging stations

Presented are equations for time synchronization of laser ranging stations. The system consists of a satellite fitted with laser retroreflectors associated to a light detector and an event timer and two laser ranging stations with their own event timers. Methods of determining the Lasso intercalibration constant are given.

Gaignebet, J.↗

SeaWiFS technical report series. Volume 16: The second SeaWiFS Intercalibration Round-Robin Experiment, SIRREX-2, June 1993

The results of the second Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-2), which was held at the Center for Hydro-Optics and Remote Sensing (CHORS) at San Diego State University on 14-25 Jun. 1993 are presented. SeaWiFS is an ocean color radiometer that is scheduled for launch in 1994. The SIRREXs are part of the SeaWiFS Calibration and Validation Program that includes the GSFC, CHORS, NIST, and several other laboratories. GSFC maintains the radiometric scales (spectral radiance and irradiance) for the SeaWiFS program using spectral irradiance standards lamps, which are calibrated by NIST. The purpose of each SIRREX is to assure that the radiometric scales which are realized by the laboratories who participate in the SeaWiFS Calibration and Validation Program are correct; that is, the uncertainties of the radiometric scales are such that measurements of normalized water-leaving radiance using oceanographic radiometers have uncertainties of 5%. SIRREX-1 demonstrated, from the internal consistency of the results, that the program goals would not be met without improvements to the instrumentation. The results of SIRREX-2 demonstrate that spectral irradiance scales realized using the GSFC standard irradiance lamp (F269) are consistent with the program goals, as the uncertainty of these measurements is assessed to be about 1%. However, this is not true for the spectral radiance scales, where again the internal consistency of the results is used to assess the uncertainty. This is attributed to inadequate performance and characterization of the instrumentation. For example, spatial nonuniformities, spectral features, and sensitivity to illumination configuration were observed in some of the integrating sphere sources. The results of SIRREX-2 clearly indicate the direction for future work, with the main emphasis on instrument characterization and the assessment of the measurement uncertainties so that the results may be stated in a more definitive manner.

Hooker, Stanford B.↗

SeaWiFs Technical Report Series. Volume 34: The Third SeaWiFS Intercalibration Round-Robin Experiment (SIRREX-3), 19-30 September 1994

This report presents results of the third Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round- Robin Experiment (SIRREX-3), which was held at the San Diego State University (SDSU) Center for Hydro-Optics and Remote Sensing (CHORS) on 19-30 September 1994. Spectral irradiances of FEL lamps belonging to each participant were intercompared by reference to the National Institute of Standards and Technology (NIST) scale of spectral irradiance using secondary standard lamps F268, F269, and F182, with a Type A uncertainty between 1.1-1.5%. This level of uncertainty was achieved despite difficulties with lamp F269. The average spectral irradiances of FEL lamps, compared in both SIRREX-2 and SIRREX-3, differed between the two experiments by 1.5%, which probably indicates that the values assigned to the secondary standard lamp at the time of SIRREX-2 were in error. With two exceptions, spectral radiance values of integrating sphere sources were measured during SIRREX-3 with uncertainties in temporal stability of less than 0.3% and absolute uncertainties of 1.5-2.0%. This is a significant improvement over similar intercomparisons in SIRREX- I and SIRREX-2. Plaque reflectances were intercompared with an uncertainty of about 1-2%, but the absolute uncertainty is undefined. Although this is an improvement over results of previous SIRREXS, the sources and magnitude of uncertainty associated with transfers of spectral radiance using plaques requires further evaluation in future experiments.

Hooker, Stanford B.↗

Sea WiFS Technical Report Series: The fourth SeaWIFS Intercalibration Round-Robin Experiment (SIRREX-4), May 1995

This report documents the fourth Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-4), which was held at the National Institute of Standards and Technology (NIST) on 3-10 May 1995. The agenda for SIRREX-4 was established by a consensus reached at the conclusion of SIRREX-3: there should be an emphasis on training and work to foster and encourage uniform use of accepted protocols for calibrating radiometric instruments in the laboratory. The goal was to host the activity in a setting where proper techniques could be discussed and demonstrated. It seemed appealing to split the day between morning lectures and afternoon laboratory exercises or practicals. The former gave the user community a chance to present what was important to them and discuss it with acknowledged experts in radiometry, while the latter presented a unique opportunity for training and evaluation in the presence of these same experts. The five laboratory sessions were concerned with (1) determining the responsivity of a spectroradiometer and the spectral radiance of an unknown integrating sphere source, (2) demonstrating spectral field calibration procedures for an integrating sphere using three different instruments, (3) measuring spectral radiance using the plaque method, (4) setting up and aligning lamp calibration transfer standards using the NIST specifications for irradiance measurements, and (5) characterizing radiometric instruments. In addition to documenting some supplemental studies performed outside the laboratory sessions, this report includes an evaluation of the hardware that has been used during the SIRREX activities plus a critical evaluation of SIRREX objectives.

Johnson, B. Carol↗

The Sixth SeaWiFS/SIMBIOS Intercalibration Round-Robin Experiment (SIRREX-6)

For the sixth Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-6), NASA personnel carried the same four Satlantic in-water radiometers to nine separate laboratories and calibrated them. Two of the sensors were seven-channel radiance heads and two were seven-channel irradiance heads. The calibration and data reduction procedures used at each site followed that laboratory's normal procedures. The reference lamps normally used for the calibration of these types of instruments by the various laboratories were also used for this experiment. NASA personnel processed the data to produce calibration parameters from the various laboratories

Riley, Thomas↗

SeaWiFS Postlaunch Technical Report Series: The Fifth Sea-WiFS Intercalibration Round-Robin Experiment (SIRREX-5), July 1996 - Volume 7

This report documents the fifth Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-5), which was held at the National Institute of Standards and Technology (NIST) on 23-30 July 1996. The agenda for SIRREX-5 was established based on recommendations made during SIRREX-4. For the first time in a SIRREX activity, instrument intercomparisons were performed at field sites, which were near NIST. The goals of SIRREX-5 were to continue the emphasis on training and the implementation of standard measurement practices, investigate the calibration methods and measurement chains in use by the oceanographic community, provide opportunities for discussion, and intercompare selected instruments. As at SIRREX-4, the day was divided between morning lectures and afternoon laboratory exercises. A set of core laboratory sessions were performed: 1) in-water radiant flux measurements; 2) in-air radiant flux measurements; 3) spectral radiance responsivity measurements using the plaque method; 4) device calibration or stability monitoring with portable field sources; and 5) various ancillary exercises designed to illustrate radiometric concepts. Before, during, and after SIRREX-5, NIST calibrated the SIRREX-5 participating radiometers for radiance and irradiance responsivity. The Facility for Automated Spectroradiometric Calibrations (FASCAL) was scheduled for spectral irradiance calibrations for standard lamps during SIRREX-5. Three lamps from the SeaWiFS community were submitted and two were calibrated.

Hooker, Stanford B.↗

Intercalibration of Meteorological Satellite Imagers Using VIRS, ATSR-2 and MODIS

Global retrievals of surface, cloud and radiative properties from geostationary (GEO) and low-Earth-orbit (LEO) meteorological satellites require accurate calibration of their imagers. An accurate and consistent calibration increases the reliability and effectiveness of long-term monitoring of climate changes. More emphasis has been placed on calibrating the thermal infrared (IR) channel. The lack of on-board calibration in the visible (VIS) channel has prompted efforts to characterize the degradation of the VIS sensor using vicarious post-launch calibration techniques that measure bright stable desert targets from space and aircraft or using satellite-to-satellite normalizations. While such inter-calibrations are valuable and widely used, the lack of a well-characterized calibration reference source and the lengthy time delay between updates have minimized their effectiveness in climate monitoring. To address these shortcomings, this paper examines the use of research satellite imagers to provide stable calibration references for the visible (VIS, approximately 0.65 micrometers) channels and develops a method for rapid intercalibration of existing satellites. Calibration coefficients are determined for the Geostationary Operational Environmental Satellites (GOES-8 to GOES-10), Geostationary Meteorological Satellite (GMS-5), Meteosat-7, and the NOAA-14 Advanced Very High Resolution Radiometer (AVHRR). As a reference calibration source, this technique uses the self-calibrating sensors on the Tropical Rainfall Measuring Mission (TRMM) Visible Infrared Radiometers (VIRS) or the ERS-2 Along Track Scanning Radiometer (ATSR-2). GOES-8 is calibrated with VIRS and then its calibration is transferred to other GEO or LEO satellites. The absolute accuracy of this technique relies on the assumption that the on-board calibration is stable and well maintained. Minnis et al. assessed the VIRS calibration using comparisons with other self-calibrated satellite sensors including the broadband Clouds and Earth's Radiant Energy System (CERES) scanners, the ERS-2 Along Track Scanning Radiometer (ATSR-2), and the Terra Moderate-resolution Imaging Spectrometer (MODIS). Thus, the VIRS data can be confidently used as the initial reference source.

Nguyen, Louis↗