ALSEP/SIDE/CCGE /Apollo Lunar Surface Experiments Package/Suprathermal Ion Detector Experiment/Cold Cathode Gauge Experiment/. Volume 2 - Appendix Final engineering report
Data for experiments for detecting lunar atmosphere and surface ion emission
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Data for experiments for detecting lunar atmosphere and surface ion emission
A compilation of reports and scientific papers is presented for the following topics: (1) the lunar ionosphere; (2) electric potential of the lunar surface; (3) ion activity on the lunar nightside; (4) bow shock protons; (5) magnetosheath and magnetotail; (6) solar wind-neutral gas cloud interactions at the lunar surface; (7) penetrating solar particles; and (8) rocket exhaust products from Apollo missions. Descriptions and photographs of ion detecting equipment at the lunar sites of Apollo 12, 13, 14, and 15 are given.
Explore the source record for details and available documents.
A new detector using an extremelly driven tuned circuit has been developed for use in ion cyclotron resonance spectroscopy experiments. Based on the Q-meter circuit, this detector will operate at frequencies greater than 1 MHz at rf levels less than 1 mV. Operation in the frequency range 1-15 MHz allows the use of higher magnetic fields for more efficient storage of low mass ions in the trapping mode of operation. In the frequency range 2-6 MHz electrons can be detected in the ion cyclotron resonance cell by their resonant motion in the trapping plane.
Fast-ion losses need to be monitored to avoid damage to plasma facing components. In existing experimental devices, the scintillator-based fast-ion loss detector (FILD) is the most advanced diagnostic for measuring fast-ion losses. However, FILDs provide only local information about the losses. Infrared (IR) thermography can be used as a complementary tool for more global monitoring of the deposition of fast-ion losses on the wall, at the expense of no velocity-space resolution. IR cameras measure the temperature of the plasma facing components. This measurement, determined by a combined effect of the thermal plasma, radiation, neutrons and fast-ion losses, can be decomposed to infer the fast-ion load on the tokamak wall. In this manuscript, a workflow to estimate fast-ion losses via IR thermography is applied to the MAST-U spherical tokamak, using a 1D approximation to extract the experimental heat flux on the FILD front face from IR data. To numerically estimate the different contributions to this total heat flux, the field-line tracing environment SMITER is used to calculate the thermal plasma contribution, the orbit-following Monte-Carlo code ASCOT to estimate the fast-ion losses, and bolometry measurements for the radiation. To validate the workflow, two discharges, L-mode plasmas with low MHD activity, were executed using on and off-axis beams, respectively. The experimentally and numerically estimated heat flux are of the same order of magnitude for the on-axis heated scenario, with a strong dependence of the estimated fast-ion losses contribution on the fit to the kinetic profiles used as input. This is also true for the off-axis heated scenario, where the total numerically estimated heat flux is 2.1 or 1.3 times higher than the maximum experimentally estimated heat flux, depending on the ASCOT input used.
Upgrades to electronic hardware and detector design have been made to the JET thin-foil Faraday cup fast ion loss detector in anticipation of the upcoming deuterium–tritium (DT) campaign. An improved foil stack design has been implemented, which greatly reduces the number of foil-to-foil shorts, and triaxial cabling has mitigated ambient noise pickup. Initial tests of 200 kHz digitizers, as opposed to the original 5 kHz digitizers, have provided enhanced analysis techniques and direct coherence measurements of fast ion losses with magnetohydrodynamic activity. Here, we present recent loss measurements in JET deuterium plasmas correlated with kink modes, fishbone modes, edge-localized modes, and sawteeth. Sources of systematic noise are discussed with emphasis on capacitive plasma pickup. Overall, the system upgrades have established a diagnostic capable of recording alpha particle losses due to a wide variety of resonant fast ion transport mechanisms to be used in future DT-experiments and modeling efforts.
Here, a conceptual design of a scintillator-based fast-ion loss detector (FILD) has been developed for the Wendelstein 7-X stellarator (W7-X). Simulations using the Monte Carlo codes ASCOT5 and BEAMS3D have been performed to calculate the expected flux of neutral beam injection (NBI)-generated fast hydrogen ions onto the conceptual detector probe head. These fast-ion loss fluxes have been calculated for several magnetic field configurations as well as probe insertion positions. At the maximum insertion position, both co-and counter-going losses with high incident pitch angles are observed; however, at retracted positions, only co-going fast ions reach the probe head. The FILDSIM code has been used to optimize the geometry of the detector entrance and collimating elements to achieve a wide velocity space coverage as well as a high velocity–space resolution. A synthetic FILD signal is calculated for the expected loss distribution via forward modeling using the instrument response function. The synthetic signal is found to largely retain the velocity space features of the loss distribution.
A new scintillator based fast-ion loss detector (FILD) system has been designed for the Wendelstein 7-X (W7-X) stellarator. The mechanical design of the system is presented here along with engineering analyses of the system. This includes an assessment of the structural loads which also considers electromagnetic forces calculated for possible disruption scenarios as well as a mode frequency analysis of the system. Furthermore, an analysis of the thermal characteristics of the actively cooled probe head under prescribed steady state and transient heat loads is presented. Finally, the optical relay system is described and its properties used to forward model synthetic camera signals using the FILDSIM code and based on theoretical fast-ion losses incident on the probe head calculated using the ASCOT5 code.
We report an analysis of one year of Suprathermal Ion Detector Experiment (SIDE) Total Ion Detector (TID) resonance events observed between January 1972 and January 1973. The study includes only those events during which upstream solar wind conditions were readily available. The analysis shows that these events are associated with lunar traversals through the dawn flank of the terrestrial magnetospheric bow shock. We propose that the events result from an increase in lunar surface electric potential effected by secondary electron emission due to primary electrons in the Earth's foreshock region (although primary ions may play a role as well). This work establishes (1) the lunar surface potential changes as the Moon moves through the terrestrial bow shock, (2) the lunar surface achieves potentials in the upstream foreshock region that differ from those in the downstream magnetosheath region, (3) these differences can be explained by the presence of energetic electron beams in the upstream foreshock region and (4) if this explanation is correct, the location of the Moon with respect to the terrestrial bow shock influences lunar surface potential.
Recent developments in the field of mass spectrometry taking place at the Caltech Jet Propulsion Laboratory are highlighted. The pertinent research and development is aimed at producing an ultrahigh sensitivity mass spectrograph for both spaceflight and terrestrial applications. The unique aspect of the JPL developed technology is an integrating focal plane ion detector that obviates the need for spectral scanning since all ions over a wide mass range are monitored simultaneously. The ion detector utilizes electro-optical technology and is therefore referred to as an Electro-Optical Ion Detector (EOID). A technical description of the JPL MS/EOID, some of the current applications, and its potential benefits for internal contamination analysis are discussed.
Abstract We present the first validated synthetic diagnostic for fast ion loss detectors (FILDs) in the Wendelstein 7-X (W7-X) stellarator. This model has been developed on, and validated against experimental data from, a FILD provided by the National Institute for Fusion Science (NIFS-FILD), with potential future applicability to the existing Faraday Cup FILD (FC-FILD) on W7-X as well as the scintillating FILD (S-FILD) currently under development. A workflow combining Monte Carlo codes BEAMS3D and ASCOT5 is used to track fast ions produced by neutral beam injection from the moment of ionization until they are thermalized or lost from the last closed flux surface, and from there to a virtual plane which serves as a projection of the entrance aperture to the FILD. Simulations in ASCOT5 are analyzed via a geometric method to determine the probability of transmission through the FILD aperture and onto the detector as a function of normalized momentum, pitch angle, gyrophase, and position at the virtual plane. This probability is then applied to the simulated ions arriving from the plasma, producing a simulated signal from a computationally tractable number of simulated fast ions. Simulated signals are presented for two W7-X experiments with neutral beam injection and quantitatively compared with experimental measurements from the NIFS-FILD diagnostic. An estimate of the frequency of charge-exchange with neutral particles in the edge is performed, and it is found that this process may have a significant impact on the measured signals.
Understanding how the Sun, Earth, and other objects in the solar system interact with the space radiation environment is crucial for improving activities of humans on Earth and in space. Low-power, low-noise, multidirectional robust detectors for detecting ions with a wide range of mass and energies will provide a more complete understanding of space environment physics. To meet these challenges, new ion detectors based on wide band gap (WBG) semiconductors are being developed for integration on a variety of deep space platforms. NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop supporting technologies to enable improved instruments for space science missions. New detector technologies being developed at GRC include SiC solid-state devices as practical robust, thermally stable large area detectors for LET measurements in compact, stacked charged particle telescope. The low-noise, thermally stable nature of the WBG detectors allows a small multidirectional array of charged particle telescopes to be packed in a 6U CubeSat without active cooling for operation in lunar orbit or deep space. Using a full variety of different WBG detectors, an extremely compact instrument to provide multi-directional, comprehensive (composition, velocity, and direction) in-situ measurements of heavy ions in space plasma environments can be realized.
A quantitative theoretical framework has been created to model neutral beam injection and fast ion losses in the Wendelstein 7-X (W7-X) stellarator, including a novel method to develop synthetic diagnostics for fast ion loss detectors (FILDs) of many types, such as scintillating and Faraday Cup FILDs. This is the first time that this has been done in stellarator geometry with this level of fidelity, providing a way for fast ion losses to be predicted more precisely in future stellarator experiments and in W7-X. Simulations of the signal seen by a Faraday Cup FILD have been completed for multiple W7-X plasmas and show close agreement with the measured signals. This method is now applied to an actively water-cooled, scintillator-based FILD, which is currently in development to measure the fast ion loss distribution in W7-X in greater detail. The design makes use of a double slit to measure energy-and-pitch-angle-resolved losses of both co-going and counter-going fast ions. The diagnostic, which can be inserted to different radial positions, has been designed to withstand steady-state heat fluxes of up to 120 kW/m 2 along with additional transient heat loads of 100 kW/m 2 lasting for up to 20 s at a time. Simulations of W7-X standard magnetic configuration show up to 8 × 10 13 (s –1 cm –2 ) ion fluxes onto the sensor from each neutral beam source and no signal from the counter-going slit. Finally, these simulations will help inform experimental proposals for future W7-X campaigns after installation of this diagnostic.
A rotating field mass and velocity analyzer having a cell with four walls, time dependent RF potentials that are applied to each wall, and a detector. The time dependent RF potentials create an RF field in the cell which effectively rotates within the cell. An ion beam is accelerated into the cell and the rotating RF field disperses the incident ion beam according to the mass-to-charge (m/e) ratio and velocity distribution present in the ion beam. The ions of the beam either collide with the ion detector or deflect away from the ion detector, depending on the m/e, RF amplitude, and RF frequency. The detector counts the incident ions to determine the m/e and velocity distribution in the ion beam.
Graphs depicting output of ion-electron scintillation counter flown on Explorer 12 satellite - August - December 1961
During a 14-hour period on Mar. 7, 1971, the Apollo 14 ALSEP suprathermal ion detector experiment (SIDE) observed an intense, prolonged series of bursts of 48.6-eV ions at the lunar surface. The SIDE mass analyzer showed the mass per unit charge of these ions to be characteristic of water vapor if singly ionized. The event was also observed by the SIDE total ion detectors (TIDs) at the Apollo 14 site and at Apollo 12 (located 183 km to the west). The TID data from SIDE 14 indicate that the energy spectrum was narrower than the 20-eV interval between energy channels. Ion spectra due to the LM exhaust gases are shown to be readily identified by the SIDE and are distinctly different in character from the spectra obtained on March 7. Detailed consideration of other possible sources of water, including the Apollo 14 CSM, leads to the conclusion that the water vapor did not come from a man-made source. Also, it is estimated that the event may have involved a quantity of water much greater than that which has been artificially introduced into the lunar environment. Consequently, it appears to be of lunar origin.
Ions from the lunar atmosphere are observed near the lunar terminators by the Apollo Suprathermal Ion Detector Experiments. These ions are accelerated toward the lunar surface by the interplanetary electric field and the lunar surface electric field. The ion implantation rates for these mechanisms are of the order of 7 and 0.4 g/sec, respectively. The removal rate into space by the interplanetary electric field is also approximately 7 g/sec. This measurement is used as a constraint to evaluate possible sources of the lunar atmosphere. Upper limits to the size of the lunar atmosphere in the past are established by computing the loss rate of denser lunar atmospheres.
Electrons and ions trapped with electromagnetic fields have long served as important high-precision metrological instruments, and more recently have also been proposed as a platform for quantum information processing. Here we point out that these systems can also be used as highly sensitive detectors of passing charged particles, due to the combination of their extreme charge-to-mass ratio and low-noise quantum readout and control. In particular, these systems can be used to detect energy depositions many orders of magnitude below typical ionization scales. As illustrations, we suggest some applications in particle physics. We outline a nondestructive time-of-flight measurement capable of sub-eV energy resolution for slowly moving, collimated particles. We also show that current devices can be used to provide competitive sensitivity to models where ambient dark matter particles carry small electric millicharges $\ll$e. Furthermore, our calculations may also be useful in the characterization of noise in quantum computers coming from backgrounds of charged particles.