ALSEP/SIDE/CCGE /Apollo Lunar Surface Experiments Package/Suprathermal Ion Detector Experiment/Cold Cathode Gauge Experiment/. Volume 2 - Appendix Final engineering report
Data for experiments for detecting lunar atmosphere and surface ion emission
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Data for experiments for detecting lunar atmosphere and surface ion emission
A compilation of reports and scientific papers is presented for the following topics: (1) the lunar ionosphere; (2) electric potential of the lunar surface; (3) ion activity on the lunar nightside; (4) bow shock protons; (5) magnetosheath and magnetotail; (6) solar wind-neutral gas cloud interactions at the lunar surface; (7) penetrating solar particles; and (8) rocket exhaust products from Apollo missions. Descriptions and photographs of ion detecting equipment at the lunar sites of Apollo 12, 13, 14, and 15 are given.
Explore the source record for details and available documents.
A new detector using an extremelly driven tuned circuit has been developed for use in ion cyclotron resonance spectroscopy experiments. Based on the Q-meter circuit, this detector will operate at frequencies greater than 1 MHz at rf levels less than 1 mV. Operation in the frequency range 1-15 MHz allows the use of higher magnetic fields for more efficient storage of low mass ions in the trapping mode of operation. In the frequency range 2-6 MHz electrons can be detected in the ion cyclotron resonance cell by their resonant motion in the trapping plane.
We report an analysis of one year of Suprathermal Ion Detector Experiment (SIDE) Total Ion Detector (TID) resonance events observed between January 1972 and January 1973. The study includes only those events during which upstream solar wind conditions were readily available. The analysis shows that these events are associated with lunar traversals through the dawn flank of the terrestrial magnetospheric bow shock. We propose that the events result from an increase in lunar surface electric potential effected by secondary electron emission due to primary electrons in the Earth's foreshock region (although primary ions may play a role as well). This work establishes (1) the lunar surface potential changes as the Moon moves through the terrestrial bow shock, (2) the lunar surface achieves potentials in the upstream foreshock region that differ from those in the downstream magnetosheath region, (3) these differences can be explained by the presence of energetic electron beams in the upstream foreshock region and (4) if this explanation is correct, the location of the Moon with respect to the terrestrial bow shock influences lunar surface potential.
Recent developments in the field of mass spectrometry taking place at the Caltech Jet Propulsion Laboratory are highlighted. The pertinent research and development is aimed at producing an ultrahigh sensitivity mass spectrograph for both spaceflight and terrestrial applications. The unique aspect of the JPL developed technology is an integrating focal plane ion detector that obviates the need for spectral scanning since all ions over a wide mass range are monitored simultaneously. The ion detector utilizes electro-optical technology and is therefore referred to as an Electro-Optical Ion Detector (EOID). A technical description of the JPL MS/EOID, some of the current applications, and its potential benefits for internal contamination analysis are discussed.
Understanding how the Sun, Earth, and other objects in the solar system interact with the space radiation environment is crucial for improving activities of humans on Earth and in space. Low-power, low-noise, multidirectional robust detectors for detecting ions with a wide range of mass and energies will provide a more complete understanding of space environment physics. To meet these challenges, new ion detectors based on wide band gap (WBG) semiconductors are being developed for integration on a variety of deep space platforms. NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop supporting technologies to enable improved instruments for space science missions. New detector technologies being developed at GRC include SiC solid-state devices as practical robust, thermally stable large area detectors for LET measurements in compact, stacked charged particle telescope. The low-noise, thermally stable nature of the WBG detectors allows a small multidirectional array of charged particle telescopes to be packed in a 6U CubeSat without active cooling for operation in lunar orbit or deep space. Using a full variety of different WBG detectors, an extremely compact instrument to provide multi-directional, comprehensive (composition, velocity, and direction) in-situ measurements of heavy ions in space plasma environments can be realized.
A rotating field mass and velocity analyzer having a cell with four walls, time dependent RF potentials that are applied to each wall, and a detector. The time dependent RF potentials create an RF field in the cell which effectively rotates within the cell. An ion beam is accelerated into the cell and the rotating RF field disperses the incident ion beam according to the mass-to-charge (m/e) ratio and velocity distribution present in the ion beam. The ions of the beam either collide with the ion detector or deflect away from the ion detector, depending on the m/e, RF amplitude, and RF frequency. The detector counts the incident ions to determine the m/e and velocity distribution in the ion beam.
Graphs depicting output of ion-electron scintillation counter flown on Explorer 12 satellite - August - December 1961
During a 14-hour period on Mar. 7, 1971, the Apollo 14 ALSEP suprathermal ion detector experiment (SIDE) observed an intense, prolonged series of bursts of 48.6-eV ions at the lunar surface. The SIDE mass analyzer showed the mass per unit charge of these ions to be characteristic of water vapor if singly ionized. The event was also observed by the SIDE total ion detectors (TIDs) at the Apollo 14 site and at Apollo 12 (located 183 km to the west). The TID data from SIDE 14 indicate that the energy spectrum was narrower than the 20-eV interval between energy channels. Ion spectra due to the LM exhaust gases are shown to be readily identified by the SIDE and are distinctly different in character from the spectra obtained on March 7. Detailed consideration of other possible sources of water, including the Apollo 14 CSM, leads to the conclusion that the water vapor did not come from a man-made source. Also, it is estimated that the event may have involved a quantity of water much greater than that which has been artificially introduced into the lunar environment. Consequently, it appears to be of lunar origin.
Ions from the lunar atmosphere are observed near the lunar terminators by the Apollo Suprathermal Ion Detector Experiments. These ions are accelerated toward the lunar surface by the interplanetary electric field and the lunar surface electric field. The ion implantation rates for these mechanisms are of the order of 7 and 0.4 g/sec, respectively. The removal rate into space by the interplanetary electric field is also approximately 7 g/sec. This measurement is used as a constraint to evaluate possible sources of the lunar atmosphere. Upper limits to the size of the lunar atmosphere in the past are established by computing the loss rate of denser lunar atmospheres.
To improve sensitivity of flame ionization detectors chop flow of sample into flame so resulting ionization will be modulated and therefore readily amplified independently of steady-state background ionization, thermoelectric effects, contact potentials, etc. Detector should discriminate sharply between desired signal and undesired signals.
The suprathermal ion detector experiment regularly observes ion events normally ranging from 250 eV/q to 1000 eV/q all through the lunar night. These ion events occur most often 2 to 3 days prior to the sunrise terminator. There is also a secondary activity peak 3 to 4 days after local sunset on the moon. The events are normally of 4 hr or less in duration, and the integral flux is 1 million ions per sq cm/sec/sr. This article discussed the character of these events and presents preliminary findings of a detailed study on this subject.
Observations of MeV heavy ions obtained by Explorer 45 in an equatorial earth orbit during a 7 month period in 1972 are presented, including data from four major magnetic storms. The spacecraft contained a heavy ion detector telescope and heavy ion discriminator electronics. Heavy ions were distinguished from protons and electrons, and He ions and ions heavier than F were recorded on separate data channels. The L equals 2.25 to L equals 4 zones were probed, and it was found that the relative enhancement in heavy ion fluxes in the radiation belts over the prestorm ion flux intensities tends to increase with increasing ion mass and/or increasing ion energy in the MeV range. The radial profiles of ions with nucleon number greater than nine peak at L equals 2.9, and MeV ions in this class decay on time scales from 23 days at L equals 3.25 to 55 days at L equals 2.25. Indirect evidence indicated a solar source for the very heavy ions in the magnetosphere.
Only outer portion of ion beam sampled to prevent unnecessary energy losses. Measurement device allows only periphery of beam to pass through scintillation material. Total flux in uniform beam inferred from peripheral flux. Device provides readings without reducing energy of ions in middle of beam. Measurement device developed for ion beams used in studies of how fast heavy ions affect integrated-circuit chips.
A detector for detecting ions and/or electrons present in a resonance cell of an ICR spectrometer is disclosed. The detector which operates on the Q-meter principle is driven by an external rf oscillator capable of providing rf frequencies up to about 15MHz at an adjustable low rf signal level, e.g., below 20mV. The detector is connected across the resonance of the cell to detect ions by detecting their cyclotron frequency. Electrons are detectable by connecting the detector across the cell's trapping plates and thereby detect the electrons' trapping motion, the frequency of which is in the megahertz range.
Grant NAG5-5084 was awarded to support the participation of South West Research Institute (SwRI) in building the energy per unit charge particle detectors for the Cusp Transient Features Campaign and analysis of flight data from these instruments. The detectors are part of an instrumented payload (Rocket 36.152, Dr. R. Pfaff, P.I.) launched from Svalbard on December 3, 1997, into the dark cusp. The particle instruments, a Cusp Electron Detector (CED) and a Cusp Ion Detector (CID), built on this project, provided differential energy and angular measurements along the rocket trajectory throughout the flight.
The ionization of neutral atoms in the lunar atmosphere produces an ionosphere around the moon. These ions are accelerated by the interplanetary electric field and local surface fields to energies of 10 to 500 eV. The Suprathermal Ion Detector Experiment (SIDE) has been observing these ions from the lunar atmosphere. The observations have been divided into four categories based on the acceleration mechanism.