Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ion-Selective Electrodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

24 records · Page 2

Development of a fully integrated analysis system for ions based on ion-selective optodes and centrifugal microfluidics

A fully integrated, miniaturized analysis system for ions based on a centrifugal microfluidics platform and ion-selective optode membranes is described. The microfluidic architecture is composed of channels, five solution reservoirs, a measuring chamber, and a waste reservoir manufactured onto a disk-shaped substrate of poly(methyl methacrylate). Ion-selective optode membranes, composed of plasticized poly(vinyl chloride) impregnated with an ionophore, a proton chromoionophore, and a lipophilic anionic additive, were cast, with a spin-on device, onto a support layer and then immobilized on the disk. Fluid propulsion is achieved by the centrifugal force that results from spinning the disk, while a system of valves is built onto the disk to control flow. These valves operate based on fluid properties and fluid/substrate interactions and are controlled by the angular frequency of rotation. With this system, we have been able to deliver calibrant solutions, washing buffers, or "test" solutions to the measuring chamber where the optode membrane is located. An analysis system based on a potassium-selective optode has been characterized. Results indicate that optodes immobilized on the platform demonstrate theoretical responses in an absorbance mode of measurement. Samples of unknown concentration can be quantified to within 3% error by fitting the response function for a given optode membrane using an acid (for measuring the signal for a fully protonated chromoionophore), a base (for fully deprotonated chromoionophore), and two standard solutions. Further, the ability to measure ion concentrations by employing one standard solution in conjunction with acid and base and with two standards alone were studied to delineate whether the current architecture could be simplified. Finally, the efficacy of incorporating washing steps into the calibration protocol was investigated.

NASA Discipline Life Sciences Technologies↗

Rechargeable alkaline zinc–manganese oxide batteries for grid storage: Mechanisms, challenges and developments

Rechargeable alkaline Zn–MnO 2 (RAM) batteries are a promising candidate for grid-scale energy storage owing to their high theoretical energy density rivaling lithium-ion systems (~400 Wh/L), relatively safe aqueous electrolyte, established supply chain, and projected costs below $100/kWh at scale. In practice, however, many fundamental chemical and physical processes at both electrodes make it difficult to achieve commercially competitive energy density and cycle life. In this paper, we present a detailed and timely analysis of the constituent materials, current commercial status, electrode processes, and performance-limiting factors of RAM batteries. We also examine recently reported strategies in RAM and related systems to address these issues through additives and modifications to the electrode materials and electrolyte, special ion-selective separators and/or coatings, and unconventional cycling protocols. We conclude with a critical summary of these developments and discussion of how future studies should be focused toward the goal of energy-dense, scalable, and cost-effective RAM systems.

25 ENERGY STORAGE↗

Self-contained, automated, long-term sensor system for monitoring of soil and water nutrients in fields

An automated, fieldable ion-selective sensor system for frequent detection of nutrients in soils or water is set forth. In one aspect, an integrated small form-factor housing includes a battery, processor, a fluid manipulation unit and reservoirs, and a chemical species detection cell. A flow-through sampling head can be connected to the detection cell and a waste reservoir by flexible tubing sealingly connected at opposite ends of the tube. In one aspect, improved performance of the ion-selective sensor includes adding an ion-to-electron transfer interlayer between an ion-selective membrane and its working electrode. In one aspect, the sensor is solid-state and uses printed polymeric composite of POT-MoS$_{2}$. The use of a porous tube for a sampling head and fluid connection at opposite ends allows not only fluid to be removed from the head to the detection cell for measurement but also flow in an opposite direction and out to a waste reservoir to clean and reset for a next sample measurement.

60 APPLIED LIFE SCIENCES↗

Electroconvection near an ion-selective surface with Butler–Volmer kinetics

We study the effects of interfacial kinetics on the electro-hydrodynamics of ion transport near an ion-selective surface using a combination of linear stability analysis and numerical simulation. The finite kinetics of the electrolyte–electrode interface affects the ion transfer and electroconvection in many ways. On a surface of fixed topography, such as a metal surface of slow and stable ion deposition or covered by a polymer membrane, the finite kinetics reduces the current in one-dimensional ion diffusion/migration, increases the critical voltage for the onset of the electroconvective instability, changes the dynamics of the electroconvection and the overlimiting current, and enhances the lateral ion diffusion within the interfacial layer. The first three effects are indirectly caused by the reaction kinetics and can be characterized by an effective voltage difference across the liquid electrolyte. In comparison, the last effect is controlled by a direct interplay between kinetics and nonlinear electroconvection. Scaling laws for ion transport and features of electroconvection are proposed. We also analyse the linear stability of a surface which evolves under ion deposition and find that the finite kinetics decreases the growth rate of both electroconvective and morphological instabilities and therefore modifies the wavenumber of the most unstable mode.

Mechanics↗

Electrodeposition of Zinc in Aqueous Electrolytes Containing High Molecular Weight Polymers

Strong polarization of the ion distribution in liquid electrolytes subjected to potential differences exceeding the thermal voltage, V T = kT/e, produces a hydrodynamic instability termed electroconvection at ion-selective interfaces. Electroconvection is desirable in some situations (e.g., electrodialysis) because it promotes mixing in a stagnant electrolyte layer, enhancing the ion flux at a fixed potential difference. It is undesirable in others (e.g., electrodeposition of metals) where early experiments show that convective fluid rolls associated with hydrodynamic instability in bounded electrolytes produce preferential metal deposition at localized regions on an electrode. Such localized deposition drives the family of morphological instabilities loosely termed dendritic electrodeposition. We experimentally investigate the effect of ultrahigh molecular weight polymer additives on the onset conditions and physical characteristics of both instabilities. Direct observations of electrodeposit morphology and tracer particle motions used in tandem with indirect electrokinetic measurements reveal that even at moderate concentrations, the polymer additives have a large beneficial effect in extending the range of electric potentials where stable electrodeposition is observed. Additionally, we report that at polymer concentrations above the entanglement threshold, high molecular weight polymers impart elasticity to liquid electrolytes which dampen electroconvective flow at a cation-selective interface but have at most a minimal effect on the bulk ionic conductivity of the liquid.

25 ENERGY STORAGE↗

Double ChemFET for the In-Line Monitoring of Silver Dosing in Potable Water Systems

With NASA Advanced Exploration Systems (AES) Life Support Systems (LSS)baselining ionic silver (Ag+) as the biocide of choice, development in silver monitoring technologies becomes necessary to monitor and control Ag+ release. Ion-selective field effect transistors (ISFETs) and chemically-sensitive field effect transistors (ChemFETs) are capable of selective detection of Ag+ with reversible and low detection limit responses. However, one major hurdle to ChemFET technologies is the requirement of a reference electrode, which can leak its fill solution into the potable water system and is prone to drift requiring frequent calibration. To circumvent this issue, a double chemically-sensitive field effect transistor (dChemFET) is proposed. The dChemFET uses a second ChemFET to selectively monitor the counter ion and serves in place of the reference electrode. This work reports on the development of the dChemFET, starting with the development of the Ag+ andNO3- ion selective membranes (ISMs) to be used in the ChemFETs. The Ag+ ISM was tested in 50-105 ppb Ag+ and showed linear, sub-Nernstian response. The NO3- ISM was tested in50-500 ppb silver ion equivalents of nitrate ion (Ag+ equiv. of NO3-) and shows linear, sub-Nernstian response as well . However, the Ag+ and NO3- ISMs face significant challenges in terms of drift that obstruct its application for long-term monitoring, but it can serve as a starting point for demonstrating the dChemFET proof of concept.

John Abdou↗