Search NASA⌕ Search

SEARCH · Search NASA

Results for “Isotope generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An atom probe tomography and inventory calculation examination of second phase precipitates in neutron irradiated single crystal tungsten

Tungsten is the prime candidate material for the plasma facing divertor system and first wall armor of future nuclear fusion reactors. However, the understanding of the microstructural and chemical evolution of pure tungsten under neutron irradiation is relatively unknown, in part due to a lack of experimental data on this topic. Here, single crystal tungsten has been irradiated in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory at a nominal temperature of 700–800 °C to damage levels of 0.1 and 1.8 displacements per atom (dpa). Inventory calculations of the neutron irradiation experiments have been used to track isotope generation and decay to inform atom probe tomography (APT) results in the determination of the transmutation-induced precipitate compositions. Furthermore, APT crystallography has been used to show the relationship between precipitates and matrix. The composition of the precipitates is shown to progress towards that of the σ-phase at the highest dose studied, with those precipitates lying along crystallographic planes similar to those of displacement-induced dislocations. This work also sets the framework for APT studies of materials that contain isotopic ratios far from those observed in the natural state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of PBR Spent Fuel Criticality and Dose Rate Compliance for Storage and Transportation

Spent tri-structural isotropic (TRISO)–based fuels have a strong track record in storage and transportation without documented incidents. This work seeks to reduce uncertainty to aid in more informed spent fuel management of TRISO-based fuels by modeling both fresh and spent pebble bed reactor (PBR) fuel and comparing the results to the regulatory standards from 10 CFR 71. SCALE was used for all modeling due to it having fast and accurate methods for handling PBR fuel modeling, as well as having an efficient method for shielding calculations in monaco with automated variance reduction using importance calculations (MAVRIC), which utilizes the consistent adjoint-driven importance sampling (CADIS) and the forward-weighted consistent adjoint-driven importance sampling (FW-CADIS) methods. KENO-VI was used for all criticality calculations, TSUNAMI was used for uncertainty quantification on k-effective, TRITON and the Oak Ridge isotope generation code (ORIGEN) were both used for depletion of the fuel, and MAVRIC was used for shielding calculations. For criticality assessments, this study focused on the requirement that the value of the neutron multiplication factor, k-effective (k-eff), would not exceed a peak value of 0.95, including uncertainty, with 95% confidence. Criticality was initially examined by modeling fresh fuel from three different designs—HTR-10 fuel, PBMR-400 fuel, and demonstration fuel representative of a TRISO-fueled modern high-temperature gas reactor (HTGR) design, henceforth referred to as Demo HTGR—and placing them into various sized containers with conditions described in 10 CFR 71 to quantify the peak k-eff state. When the peak value of 0.95 k-eff was exceeded, mitigation methods were examined in those scenarios. Burnup credit, pebble displacement in areas of strong neutron multiplication, and random pebble replacement using pebbles of various compositions and replacement fractions were examined. In summary, the criticality of PBR fuels can be well accounted for by restricting container size, taking credit for burnup, or by displacing/replacing pebbles. Uncertainty of the k-eff due to nuclear data uncertainties was recorded at ~0.6644%Δk/k, or roughly 664% mil (pcm). The nuclear data–induced uncertainty was relatively small and should not require significant modification in the design to be accounted for. Revisions to the evaluated nuclear data file values have been shown to have a larger impact than nuclear data–induced uncertainty. For dose rate aspects, U.S. Nuclear Regulatory Commission regulations require a maximum dose rate of 10 millirem per hour (mrem/h) at 2 meters. In examining the dose rate behavior of spent PBR fuel, the representative Demo HTGR fuel was modeled exclusively due to it possessing the highest target burnup of the examined fuels. Equilibrium cycle modeling methods were used to produce a higher-fidelity discharge isotopic composition than simple assumptions, such as reflected pebbles. The discharge composition was used as a source term in the fixed-source transport shielding calculations, and dose rates were calculated at 2 m for the shortest possible cooling time. The low concentration of fuel material led to dose rates that were in line with regulatory limits, despite the high burnup when compared to traditional light water reactor fuels. In conclusion, the methods employed in this study would require more work to further verify and validate and are limited to the criticality and dose rate analyses performed.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Behavior of selenium and arsenic in $\mathrm{HCl}$ and $\mathrm{HNO}$ 3 on $\mathrm{TRU, TEVA, DGA,}$ and $\mathrm{Pb}$ extraction chromatography resins

The uptake behavior of 73 As and 75 Se was studied in HCl and HNO 3 -H 2 O 2 solutions on commercial extraction chromatography resins (TEVA, TRU, DGA, and Pb resin). There was no uptake of 73 As or 75 Se from HNO 3 media. From HCl, there was 75 Se uptake at high concentrations on all the resins and no uptake of 73 As. Separations of 75 Se and 73 As on these resins have high yields and high radiopurity for 73 As, but limited recovery of 75 Se. TRU and TEVA resin may have potential for use in isotope generators as 75 Se can be retained for at least 26 days with repeated elutions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Synthesis and characterization of isotopically barcoded nickel, molybdenum, and tungsten taggants for intentional nuclear forensics

Intentional nuclear forensics is a concept wherein the deliberate addition of benign and persistent material signatures to nuclear material can be used to reduce the time between the discovery of material outside of regulatory control and determination of its original provenance. One concept within intentional nuclear forensics involves the use of perturbed stable isotopes to generate unique isotope ratio “barcodes” to encode information (e.g., production batch, location, etc.) and track material throughout the nuclear fuel cycle. Synthesis of taggant species of nickel (Ni), molybdenum (Mo), and tungsten (W) was undertaken via a double-spike mechanism, wherein two highly enriched isotopes of interest per elemental taggant were mixed to form an enriched “double-spike” which was subsequently isotopically diluted with bulk material having a natural isotopic composition. Two taggant species perturbing isotopic ratios, alpha (α) and beta (β), for each of Ni, Mo, and W were synthesized. Independent measurements of double spikes and alpha and beta taggant species agreed within uncertainty and are clearly resolvable from natural compositions. High-precision analyses were independently performed by MC-ICP-MS at two U.S. National Laboratories, with consensus values and uncertainties calculated for all samples. Observed isotopic perturbations in the final taggant species measured on the order of hundreds to thousands of permille (‰) with respect to natural for isotope ratios of interest (e.g., 60 Ni/ 58 Ni, 100 Mo/ 98 Mo, 186 W/ 183 W). Discrepancies between modeled and measured isotopic compositions were observed and are largely attributed to imprecise vendor assay values for starting materials. Using measured starting material compositions as inputs for the mixing model improved the level of agreement between predicted and measured α and β taggant isotope ratios. Overall, characterization of all taggant species demonstrates that this “barcode” concept could have viability for use in nuclear forensics. Finally, it is expected that for any two-isotope mixing array dozens of isotopic barcodes could be encoded into a material system and subsequently resolved utilizing modern mass spectrometric methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

An engineering perspective on evaluating mechanisms governing ductility in pure molybdenum

The United States lacks a stable domestic supply of 99 mTc, a critical medical imaging isotope generated from 99 Mo. Accelerator-based production using 100 Mo targets (aMo) introduces mechanical concerns due to the ductile-to-brittle transition temperature inherent to refractory metals like Mo. This study evaluates the tensile behavior of aMo targets from 25 to 1000 °C, compared to powder-metallurgy-processed natural Mo (PMo) and cast-and-rolled Mo (RMo), both as-received and after 5 ppm O 2 exposure in flowing He. RMo showed superior ductility (7.3% at 25 °C, 48% at 1000 °C) and strength, attributed to its fine, elongated grains and high geometrically necessary dislocation density. PMo exhibited variable ductility (up to 33%), while aMo remained brittle, with a maximum elongation of 10.4% at 600 °C. EBSD analysis revealed weak texture in PMo and aMo, but high defect density in aMo limited dislocation mobility. This work links processing, microstructure, and deformation mechanisms to guide fabrication of ductile refractory targets.

Hyer, Holden C. [Oak Ridge National Laboratory (OR↗

Oak Ridge National Laboratory Shutdown Dose Rate Code Suite

The Oak Ridge National Laboratory (ORNL) shutdown dose rate (SDDR) code suite calculates gamma dose rates at a location of interest due to activation of materials. The code suite is based on the rigorous two-step (R2S) method that involves two radiation transport calculations: (1) neutron radiation transport to determine neutron fluxes in the material for which activation calculations will be performed and (2) gamma radiation transport to determine dose rates at a location of interest, due to material activation. The ORNL SDDR code suite is used to determine an importance function that characterizes the neutron’s importance to the final SDDR when the Monte Carlo radiation transport method is used. This report demonstrates how the ORNL SDDR code suite is implemented through the following codes: Monte Carlo N-Particle (MCNP) code Version 5-1.60, Oak Ridge Isotope Generator (ORIGEN), MSX suite of utilities, Neutron Activation Gamma Source Sampler (NAGSS), and Automated Variance Reduction Generator (ADVANTG). For this demonstration, the International Thermonuclear Experimental Reactor (ITER) SDDR benchmark problem is used and the dose rate result is compared to previously published work.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis with the ORIGEN Module of PNAR Spent Fuel Measurements for Nuclear Safeguards Applications

This report documents the analysis of the Passive Neutron Albedo Reactivity (PNAR) measurements for 23 boiling water reactor spent fuel assemblies that were performed in Finland under Action Sheet 65, which is an international collaboration on spent fuel safeguards verification methods in the context of the Finnish spent fuel encapsulation/repository system. PNAR measures the passive neutron and gamma emission rates from each of the spent fuel assemblies like a Fork detector, and it also measures the PNAR ratio, which is expected to correlate with the net neutron multiplication of the measured fuel assembly. The analysis was performed with the Oak Ridge Isotope Generation and Depletion (ORIGEN) Data Analysis Module, which was originally developed for predicting Fork detector spent fuel measurement signals in real time and has been integrated into the Integrated Review and Analysis Package developed by Euratom and the International Atomic Energy Agency. The module includes the ORIGEN burnup analysis code and integrates detector response functions pregenerated using the MCNP Monte Carlo transport code to predict the detector signals in several seconds per assembly. In this study, new response functions specific to the analyzed PNAR measurements were generated for the ORIGEN Module. The study also analyzes the impact of using detailed fuel design and operation information vs. standard safeguards information on the results calculated with the ORIGEN Module. Using detailed information reduced the standard deviation of the relative differences between calculated and measured neutron count rates among the 23 assemblies from ~10% to ~4%. The results obtained using standard safeguards information for these PNAR measurements were similar to those obtained for the Fork detector. A clear trend was found between the calculated net neutron multiplications and the measured PNAR ratios of the 23 assemblies. An uncertainty assessment of the calculations was also performed to estimate the potential impact of the accuracy and the completeness of declaration information on the calculated results for the count rates and net neutron multiplications. The ORIGEN Module predictions for PNAR signals and net neutron multiplication are expected to directly support the safeguards inspectors’ efforts to verify operator declarations of a spent fuel assembly in real time in safeguards practices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of Frozen Chemistry for Molten Salt Reactors (MSRs)

Understanding accident progression and the potential/conditions for fission product release from fuel is necessary to evaluate safety for any nuclear reactor system. Molten Salt Reactors (MSRs) under development need such analysis to support safety evaluations. Fission product chemistry specific to MSR concepts is a critical area that introduces distinct considerations relative to the current state-of-knowledge in reactor safety, primarily developed for water-moderated nuclear reactor systems. In Light Water Reactor (LWR) systems, it is necessary to capture the chemical interaction of fission products with the reactor evironment, containment and confinement systems. The overall effects at this point are relatively well understood for the purposes of performing safety evaluations. A key insight from LWR studies is that fission product chemical behavior can be reasonably captured by modeling approaches where the chemistry is "frozen". These modeling approaches assume that radionuclide reaction and speciation can be represented by chemical classes, each with characteristic transport behavior that is invariant under a broad range of thermochemical conditions. However, radionuclides can exhibit a range of behavior in the liquid salt-melt phase of the coolant used in MSRs. Radionuclides, salt, and the metal containment surfaces (i.e. pipes) can co-exist in dynamic equilibrium that could evolve with small system mass changes. A detailed investigation to the degree the equilibrium state can dynamically evolve with changes in the conditions of the molten salt mixture has not been previously conducted. It is currently not well understood where frozen chemistry assumptions are valid. Expanding the state-of-knowledge in this regard is relevant to better assessing the range of chemical effects that should be incorporated as part of MSR safety assessments. This investigation used the Oak Ridge Isotope GENeration (ORIGEN) module of the Standardized Computer-Analysis for Licensing Evaluation (SCALE) code to generate simulated radionuclide inventories for the MSR Experiment (MSRE) and then modeled reactor chemical speciation using the Molten Salt Thermodynamic Database – Thermochemical (MSTDB-TC) coupled with Thermochimica. The effect of composition variation during decay of fission product inventory in a molten salt over a period of 500 days prolonged post- at multiple temperatures was studied. Mass fractions for fluorine and berilium were varied in order to probe the effects of free fluorine control. Finally, speciation of fluoride reactors were showed by comparing MSRE readionuclide inventories with a FLiBe based molten salt breeder reactor (MSBR). The results showed that fission product mass change has little effect on phase mass changes and vapor pressures for fluoride species, but differ with varying carrier and fuel salt compositions. However, iodine species were found to have a vapor pressure not only dependent on temperature, but also the free fluorine potential, releasing iodine when the free fluorine potential is equal to the iodine inventory. This observation, however, arose under free fluorine potentials that are very unlikely to be realized in typical molten salt mixtures. Despite this observation, temperature was found to be the dominant parameter that drove phase change and fission product species vapor pressure. The results indicate that the current frozen chemistry approach is adequate for MSR analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Burnup Monitoring for Pebble Bed Reactor Systems

A pebble burnup monitoring system is a required component for domestic reactor safety and safeguards applications associated with pebble bed reactors (PBRs). One of the main requirements of a PBR burnup monitoring system is that it needs to be capable of rapid measurements to assess the burnup of each individual pebble to determine whether to recirculate it in the reactor or discard it as spent fuel. This report considers three different approaches for a burnup monitoring system for pebbles discharged from the reactor core in a pebble bed modular reactor-400: • passive gamma spectrometry measurement, • passive neutron coincidence measurement, and • active neutron counter based on the differential die-away technique. Conceptual designs have been created for each of these detectors, and preliminary analysis has been performed using Monte Carlo N-Particle and Oak Ridge Isotope Generation code simulations. The advantages and practical limitations (e.g., high radiation background) of each system were identified. Simulations suggest that each of the three measurement techniques can be successfully employed to distinguish between pebbles based on their number of passes through the core and to quantify the burnup of pebbles.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

JMOCUP Physics Depletion Calculations for the As-Run AGR-5/6/7 TRISO Particle Experiment in ATR Northeast Flux Trap

This ECAR documents the as-run Jim Sterbentz’s MCNP ORIGEN Coupled Utility Program (JMOCUP) physics depletion calculation and the calculated results for the AGR-5/6/7 irradiation experiment in the Advanced Test Reactor (ATR). AGR 5/6/7 was irradiated for nine power cycles in the northeast flux trap. The depletion calculations were performed to provide input data for a variety of other engineering analyses supporting the AGR-5/6/7 experiment along with post-irradiation characterization of the tri-structural isotropic (TRISO) particle fuel compacts. Detailed full-core MCNP models and Oak Ridge Isotope Generation (ORIGEN2) radionuclide generation models were specifically developed as part of the JMOCUP Monte Carlo depletion calculations. The MCNP ORIGEN2 computer codes were coupled using the well-established JMOCUP utility modules to couple the two codes and run the depletion calculations. The physics calculations were performed in support of the Advanced Gas Reactor (AGR) program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High temperature and high beam current compatible targets and methods thereof for generating noble gas/radiohalogen generators for medical isotopes

A method of providing alpha particle emitters and materials suitable for use in generating the alpha particles for medical treatment is disclosed. Metal oxide targets, preferentially Bi 2 O 3 pellets and Bi 2 O 3 coatings on metallic or metal oxide substrates are formed. The targets placed in a heated vacuum chamber subjecting to irradiation using a 6 Li beam at an elevated temperature below the melting point of the target generate a radioactive gas, such as 211 Rn, the radioactive gas is carried by an inert gas which is delivered a carrier for, such as a carbon column or oil for delivery to a treatment facility. The radioactive gas such as 211 Rn generates 211 At, which has a useable half-life of at least about 14 hours, in turn releases alpha particles which are effective for use in medical procedures.

Sampathkumaran, Uma↗

Gas generation and intramolecular isotope study in laboratory pyrolysis of the Springfield coal from the Illinois Basin

Position-specific (PS) isotopes of propane have been proposed as a potential geochemical tool to decipher various geological processes (e.g., thermal cracking, biodegradation, H exchange) in natural reservoirs. The limited studies have been conducted on the PS isotopes of propane from the pyrolysis gases from marine shales, and natural gases sourced from lacustrine and marine kerogens, but little is known on gases produced from the humic kerogen. Here, this study investigated the PS δ 13 C of propane in the closed-system pyrolysis of the Springfield coal, Illinois Basin, Indiana, at 310 to 470 °C (Easy %Ro: 0.76 to 3.07). The C kinetic isotope effect (KIE) of CH 4 produced in both this study and previous low-temperature pyrolysis of the same coal indicates the cleavage of C—O bonds is the main generation pathway at the early kerogen cracking stage, followed by the breakdown of alkyl groups. At the wet-gas cracking stage, C 3 H 8 production from thermally stable compounds has a significant influence on the bulk and position-specific C KIE in the pyrolysis of marine Woodford kerogen and Springfield coal. According to the PS δ 13 C of propane, the central site is likely more enriched in 13 C and the δ 13 C of the terminal site is relatively heterogeneous within the propyl group attached to different functional groups of the gas-prone kerogen. Our findings based on the pyrolysis experiments and natural gas samples indicate thermal cracking and biodegradation appear to alter the δ 13 C cen values more significantly than the δ 13 C ter values of propane. The larger magnitude of ΔC c-t in the kMC simulations (Peterson et al., 2018) compared with those from the marine shale and coal possibly implies the non-random distributions of 13 C of propane precursors in the kerogens. As a new dimension of intramolecular isotopic information of propane, the PS δ 13 C values can contribute to fingerprinting the gas origins and identifying the various geological processes (e.g., kerogen cracking, wet-gas cracking, microbial activities) in sedimentary basins.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A dynamic isotope power system portable generator for the moon or Mars

The dynamic isotope power systems (DIPS) demonstration program is focused on a standardized 2.5 kWe portable generator for multiple uses on the lunar or Martian surface. A variety of potential remote or mobile applications has been identified by NASA. These applications include remote power to science packages, surface rovers for both short and extended duration missions, and backup to central base power. Reviews conducted on alternative power sources for these applications are described. These include the comparison of DIPS to regenerative fuel cells (RFCs). Recent work is presented refining the 2.5 kWe design to assure compatibility with the Martian environment while imposing only a minor mass penalty on lunar operations. This was accomplished by limiting temperatures, except in the heat source unit (HSU), to the nonrefractory materials regime and protecting the necessary refractories in the HSU from the environment. Design changes to the HSU are described. Work related to recent concerns regarding astronaut radiation doses is described. This work includes the bases for the calculations to determine the necessary shielding or operational limitations.

Johnson, Richard A.↗

Projected network performance for multiple isotopes using next-generation xenon monitoring systems

Since about 2000 (Bowyer et al., 1998), radioxenon monitoring systems have been under development and testing for the verification of the Comprehensive Nuclear Test-Ban Treaty (CTBT). Operation of the systems since then has resulted in development of a next-generation of systems that are nearly ready for operational deployment. By 2010, the need to screen out civilian sources was well known (Auer et al., 2010; Saey, 2009), and isotopic ratio approaches were soon considered (Kalinowski et al., 2014) to identify specific sources. New generation systems are expected to improve the ability to verify the absence of nuclear tests by using isotopic ratios when multiple isotopes are detected. In this work, thousands of releases were simulated to compute the global detection probability of 131m Xe, 133m Xe, 133 Xe, and 135 Xe at 39 noble gas systems in the International Monitoring System (IMS) for both current and next-generation systems. Three release scenarios are defined at 1 h, 1 d, and 10 d past a 1 kt TNT equivalent 235U explosion event. Multiple cases using from one part in a million to the complete release of the xenon isotopic activity are evaluated for each scenario. Coverage maps and global integrals comparing current and next-generation monitoring systems are presented showing that next-generation noble gas systems will create measurable improvements in the IMS. The global detection probability for 133 Xe is shown to be strong in all scenarios, but only modestly improved by next-generation equipment. However, the detection probability for 131m Xe and 133m Xe increased to about 50% in different scenarios, providing a second detectable isotope for many events. As anticipated from shorter sampling intervals, the expected number of detecting samples roughly doubled and the expected number of detecting stations rose by approximately 50% for all release scenarios. Thus, it might be anticipated that future events would consist of multiple 133 Xe detections and one or more second isotope detections. In conclusion, signals of this nature should increase detection confidence, tighten release location estimates, improve rejection of civilian signals, and lessen the impacts from individual systems being offline for maintenance or repair reasons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Refining Methods to Determine the Isotopic Composition of Uranium Particles by Laser Ablation MC-ICP-MS

We report on efforts to mitigate the generation of isotopic anomalies during the ablation of micrometer-sized uranium oxide particles and analysis by MC-ICP-MS. The results of testing on particles of U200 indicate that laser fluence and frequency can affect isotopic data produced by laser ablation, but no settings were tested that could eradicate the signal spiking effect and generation of anomalous isotopic data for 234U/238U and 236U/238U. These anomalies are more frequent in samples with higher 235U enrichments, which is expected given their higher abundances of 234U and 236U. Of the standards tested here, only U005-A was anomaly-free. Efforts to compare the laser traces for particles with normal and anomalous isotopic compositions showed subtle differences in the behavior of the 234U/238U and 236U/238U ratios. However, it would be challenging to identify anomalous data points from a population of unknowns using this distinction, i.e., this is unlikely to be diagnostic. Thus, using current analytical hardware, we cannot eradicate the signal spiking phenomenon and cannot unambiguously identify isotopic anomalies from laser ablation traces. Ultimately, laser ablation ICP-MS would either require dramatic improvement to the ablation process and generation of more homogenous aerosols and/or improvements to detector electronics to identify and correct for the spiking phenomenon. Even if the reliability of the technique could be improved, a broader question to address is whether current data quality is of a high enough standard for laser ablation MC-ICP-MS to be used as a complementary technique to LG-SIMS for Safeguards.

organic↗

Constraints on triple oxygen isotope kinetics

Triple oxygen isotope measurements have been used as tracers for classifying meteorites, as indicators of atmospheric chemistry and as a proxy for primary productivity among other uses. These utilities rely on the mass dependency of most chemical reactions: δ17O is proportional to δ18O by roughly a factor of 0.5. However,in detail it is known that mass-dependency factorsvary. Constraints on mass dependency are well established for equilibrium isotope effects, but similar constraints for kinetic isotope effects are lacking.Here, we provide constraints for isotope effects generated by unidirectional chemical reactions (i.e. kinetic isotope effects, KIEs). A simplified Monte Carlo model is used to estimatethe range of kinetic isotope effects. It is found that the range of KIEs exceeds the range of equilibrium isotope effects such that some mass dependent kinetic isotope effects could be mistaken for being mass-independent. For the16O-17O-18O system,Δ′17Ovariations as large 0.8‰ can be generated from a single reaction step. Two case studies from published literature, on the thermal decomposition of calcite (CaCO3) and brucite (Mg(OH)2), are used to test the extreme limits of the modeled results. Isotope fractionationsgenerated fromdensity functional theory models of the surface reaction steps are shownto match the published data. The fractionation models are strictly mass dependent thus this result suggests thermal decomposition of calcite is also mass dependent. Although oxygen is the focus here, our approach applies to any system with more than two isotopes.

J. A. Hayles↗

Visual imaging control systems of the Mariner to Jupiter and Saturn spacecraft

Design and fabrication of optical systems for the Mariner Jupiter Saturn (Voyager) mission is described. Because of the long distances of these planets from the sun, the spacecraft was designed without solar panels with the electricity generated on-board by radio-isotope thermal generators (RTG). The presence of RTG's and Jupiter radiation environment required that the optical systems be fabricated out of radiation stabilized materials. A narrow angle and a wide angle camera are located on the spacecraft scan platform, with the narrow angle lens a modification of the Mariner 10 lens. The optical system is described, noting that the lens was modified by moving the aperture correctors forward and placing a spider mounted secondary mirror in the original back surface of the second aperture corrector. The wide angle lens was made out of cerium doped, radiation stabilized optical glass with greatest blue transmittance, which would be resistant to RTG and Jupiter radiation.

Larks, L.↗

Compact assembly for production of medical isotopes via photonuclear reactions

The invention provides a method for generating medical isotopes, the method comprising contacting a primary radiation beam with a converter for a time sufficient to produce a secondary beam of gamma particles, and contacting the beam of gamma particles to a target, where the cross section dimension of the beam of gamma particles is similar to the cross section dimension of the target. Both the converter and target are small in diameter and very closely spaced. Also provided is a system for producing medical isotopes, the device comprising a housing having a first upstream end and a second downstream end, a radiotransparent channel (collimator) with a first upstream end and a downstream end, wherein the upstream end is adapted to receive a radiation beam, a target positioned downstream of the downstream end of the channel and coaxially aligned with the channel, wherein the target has a cross section that is similar to the cross section of the channel.

Nolen, Jr., Jerry A.↗