Search NASA⌕ Search

SEARCH · Search NASA

Results for “Isotope generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An engineering perspective on evaluating mechanisms governing ductility in pure molybdenum

The United States lacks a stable domestic supply of 99 mTc, a critical medical imaging isotope generated from 99 Mo. Accelerator-based production using 100 Mo targets (aMo) introduces mechanical concerns due to the ductile-to-brittle transition temperature inherent to refractory metals like Mo. This study evaluates the tensile behavior of aMo targets from 25 to 1000 °C, compared to powder-metallurgy-processed natural Mo (PMo) and cast-and-rolled Mo (RMo), both as-received and after 5 ppm O 2 exposure in flowing He. RMo showed superior ductility (7.3% at 25 °C, 48% at 1000 °C) and strength, attributed to its fine, elongated grains and high geometrically necessary dislocation density. PMo exhibited variable ductility (up to 33%), while aMo remained brittle, with a maximum elongation of 10.4% at 600 °C. EBSD analysis revealed weak texture in PMo and aMo, but high defect density in aMo limited dislocation mobility. This work links processing, microstructure, and deformation mechanisms to guide fabrication of ductile refractory targets.

Hyer, Holden C. [Oak Ridge National Laboratory (OR↗

Oak Ridge National Laboratory Shutdown Dose Rate Code Suite

The Oak Ridge National Laboratory (ORNL) shutdown dose rate (SDDR) code suite calculates gamma dose rates at a location of interest due to activation of materials. The code suite is based on the rigorous two-step (R2S) method that involves two radiation transport calculations: (1) neutron radiation transport to determine neutron fluxes in the material for which activation calculations will be performed and (2) gamma radiation transport to determine dose rates at a location of interest, due to material activation. The ORNL SDDR code suite is used to determine an importance function that characterizes the neutron’s importance to the final SDDR when the Monte Carlo radiation transport method is used. This report demonstrates how the ORNL SDDR code suite is implemented through the following codes: Monte Carlo N-Particle (MCNP) code Version 5-1.60, Oak Ridge Isotope Generator (ORIGEN), MSX suite of utilities, Neutron Activation Gamma Source Sampler (NAGSS), and Automated Variance Reduction Generator (ADVANTG). For this demonstration, the International Thermonuclear Experimental Reactor (ITER) SDDR benchmark problem is used and the dose rate result is compared to previously published work.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis with the ORIGEN Module of PNAR Spent Fuel Measurements for Nuclear Safeguards Applications

This report documents the analysis of the Passive Neutron Albedo Reactivity (PNAR) measurements for 23 boiling water reactor spent fuel assemblies that were performed in Finland under Action Sheet 65, which is an international collaboration on spent fuel safeguards verification methods in the context of the Finnish spent fuel encapsulation/repository system. PNAR measures the passive neutron and gamma emission rates from each of the spent fuel assemblies like a Fork detector, and it also measures the PNAR ratio, which is expected to correlate with the net neutron multiplication of the measured fuel assembly. The analysis was performed with the Oak Ridge Isotope Generation and Depletion (ORIGEN) Data Analysis Module, which was originally developed for predicting Fork detector spent fuel measurement signals in real time and has been integrated into the Integrated Review and Analysis Package developed by Euratom and the International Atomic Energy Agency. The module includes the ORIGEN burnup analysis code and integrates detector response functions pregenerated using the MCNP Monte Carlo transport code to predict the detector signals in several seconds per assembly. In this study, new response functions specific to the analyzed PNAR measurements were generated for the ORIGEN Module. The study also analyzes the impact of using detailed fuel design and operation information vs. standard safeguards information on the results calculated with the ORIGEN Module. Using detailed information reduced the standard deviation of the relative differences between calculated and measured neutron count rates among the 23 assemblies from ~10% to ~4%. The results obtained using standard safeguards information for these PNAR measurements were similar to those obtained for the Fork detector. A clear trend was found between the calculated net neutron multiplications and the measured PNAR ratios of the 23 assemblies. An uncertainty assessment of the calculations was also performed to estimate the potential impact of the accuracy and the completeness of declaration information on the calculated results for the count rates and net neutron multiplications. The ORIGEN Module predictions for PNAR signals and net neutron multiplication are expected to directly support the safeguards inspectors’ efforts to verify operator declarations of a spent fuel assembly in real time in safeguards practices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of Frozen Chemistry for Molten Salt Reactors (MSRs)

Understanding accident progression and the potential/conditions for fission product release from fuel is necessary to evaluate safety for any nuclear reactor system. Molten Salt Reactors (MSRs) under development need such analysis to support safety evaluations. Fission product chemistry specific to MSR concepts is a critical area that introduces distinct considerations relative to the current state-of-knowledge in reactor safety, primarily developed for water-moderated nuclear reactor systems. In Light Water Reactor (LWR) systems, it is necessary to capture the chemical interaction of fission products with the reactor evironment, containment and confinement systems. The overall effects at this point are relatively well understood for the purposes of performing safety evaluations. A key insight from LWR studies is that fission product chemical behavior can be reasonably captured by modeling approaches where the chemistry is "frozen". These modeling approaches assume that radionuclide reaction and speciation can be represented by chemical classes, each with characteristic transport behavior that is invariant under a broad range of thermochemical conditions. However, radionuclides can exhibit a range of behavior in the liquid salt-melt phase of the coolant used in MSRs. Radionuclides, salt, and the metal containment surfaces (i.e. pipes) can co-exist in dynamic equilibrium that could evolve with small system mass changes. A detailed investigation to the degree the equilibrium state can dynamically evolve with changes in the conditions of the molten salt mixture has not been previously conducted. It is currently not well understood where frozen chemistry assumptions are valid. Expanding the state-of-knowledge in this regard is relevant to better assessing the range of chemical effects that should be incorporated as part of MSR safety assessments. This investigation used the Oak Ridge Isotope GENeration (ORIGEN) module of the Standardized Computer-Analysis for Licensing Evaluation (SCALE) code to generate simulated radionuclide inventories for the MSR Experiment (MSRE) and then modeled reactor chemical speciation using the Molten Salt Thermodynamic Database – Thermochemical (MSTDB-TC) coupled with Thermochimica. The effect of composition variation during decay of fission product inventory in a molten salt over a period of 500 days prolonged post- at multiple temperatures was studied. Mass fractions for fluorine and berilium were varied in order to probe the effects of free fluorine control. Finally, speciation of fluoride reactors were showed by comparing MSRE readionuclide inventories with a FLiBe based molten salt breeder reactor (MSBR). The results showed that fission product mass change has little effect on phase mass changes and vapor pressures for fluoride species, but differ with varying carrier and fuel salt compositions. However, iodine species were found to have a vapor pressure not only dependent on temperature, but also the free fluorine potential, releasing iodine when the free fluorine potential is equal to the iodine inventory. This observation, however, arose under free fluorine potentials that are very unlikely to be realized in typical molten salt mixtures. Despite this observation, temperature was found to be the dominant parameter that drove phase change and fission product species vapor pressure. The results indicate that the current frozen chemistry approach is adequate for MSR analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Burnup Monitoring for Pebble Bed Reactor Systems

A pebble burnup monitoring system is a required component for domestic reactor safety and safeguards applications associated with pebble bed reactors (PBRs). One of the main requirements of a PBR burnup monitoring system is that it needs to be capable of rapid measurements to assess the burnup of each individual pebble to determine whether to recirculate it in the reactor or discard it as spent fuel. This report considers three different approaches for a burnup monitoring system for pebbles discharged from the reactor core in a pebble bed modular reactor-400: • passive gamma spectrometry measurement, • passive neutron coincidence measurement, and • active neutron counter based on the differential die-away technique. Conceptual designs have been created for each of these detectors, and preliminary analysis has been performed using Monte Carlo N-Particle and Oak Ridge Isotope Generation code simulations. The advantages and practical limitations (e.g., high radiation background) of each system were identified. Simulations suggest that each of the three measurement techniques can be successfully employed to distinguish between pebbles based on their number of passes through the core and to quantify the burnup of pebbles.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

JMOCUP Physics Depletion Calculations for the As-Run AGR-5/6/7 TRISO Particle Experiment in ATR Northeast Flux Trap

This ECAR documents the as-run Jim Sterbentz’s MCNP ORIGEN Coupled Utility Program (JMOCUP) physics depletion calculation and the calculated results for the AGR-5/6/7 irradiation experiment in the Advanced Test Reactor (ATR). AGR 5/6/7 was irradiated for nine power cycles in the northeast flux trap. The depletion calculations were performed to provide input data for a variety of other engineering analyses supporting the AGR-5/6/7 experiment along with post-irradiation characterization of the tri-structural isotropic (TRISO) particle fuel compacts. Detailed full-core MCNP models and Oak Ridge Isotope Generation (ORIGEN2) radionuclide generation models were specifically developed as part of the JMOCUP Monte Carlo depletion calculations. The MCNP ORIGEN2 computer codes were coupled using the well-established JMOCUP utility modules to couple the two codes and run the depletion calculations. The physics calculations were performed in support of the Advanced Gas Reactor (AGR) program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High temperature and high beam current compatible targets and methods thereof for generating noble gas/radiohalogen generators for medical isotopes

A method of providing alpha particle emitters and materials suitable for use in generating the alpha particles for medical treatment is disclosed. Metal oxide targets, preferentially Bi 2 O 3 pellets and Bi 2 O 3 coatings on metallic or metal oxide substrates are formed. The targets placed in a heated vacuum chamber subjecting to irradiation using a 6 Li beam at an elevated temperature below the melting point of the target generate a radioactive gas, such as 211 Rn, the radioactive gas is carried by an inert gas which is delivered a carrier for, such as a carbon column or oil for delivery to a treatment facility. The radioactive gas such as 211 Rn generates 211 At, which has a useable half-life of at least about 14 hours, in turn releases alpha particles which are effective for use in medical procedures.

Sampathkumaran, Uma↗

Gas generation and intramolecular isotope study in laboratory pyrolysis of the Springfield coal from the Illinois Basin

Position-specific (PS) isotopes of propane have been proposed as a potential geochemical tool to decipher various geological processes (e.g., thermal cracking, biodegradation, H exchange) in natural reservoirs. The limited studies have been conducted on the PS isotopes of propane from the pyrolysis gases from marine shales, and natural gases sourced from lacustrine and marine kerogens, but little is known on gases produced from the humic kerogen. Here, this study investigated the PS δ 13 C of propane in the closed-system pyrolysis of the Springfield coal, Illinois Basin, Indiana, at 310 to 470 °C (Easy %Ro: 0.76 to 3.07). The C kinetic isotope effect (KIE) of CH 4 produced in both this study and previous low-temperature pyrolysis of the same coal indicates the cleavage of C—O bonds is the main generation pathway at the early kerogen cracking stage, followed by the breakdown of alkyl groups. At the wet-gas cracking stage, C 3 H 8 production from thermally stable compounds has a significant influence on the bulk and position-specific C KIE in the pyrolysis of marine Woodford kerogen and Springfield coal. According to the PS δ 13 C of propane, the central site is likely more enriched in 13 C and the δ 13 C of the terminal site is relatively heterogeneous within the propyl group attached to different functional groups of the gas-prone kerogen. Our findings based on the pyrolysis experiments and natural gas samples indicate thermal cracking and biodegradation appear to alter the δ 13 C cen values more significantly than the δ 13 C ter values of propane. The larger magnitude of ΔC c-t in the kMC simulations (Peterson et al., 2018) compared with those from the marine shale and coal possibly implies the non-random distributions of 13 C of propane precursors in the kerogens. As a new dimension of intramolecular isotopic information of propane, the PS δ 13 C values can contribute to fingerprinting the gas origins and identifying the various geological processes (e.g., kerogen cracking, wet-gas cracking, microbial activities) in sedimentary basins.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Projected network performance for multiple isotopes using next-generation xenon monitoring systems

Since about 2000 (Bowyer et al., 1998), radioxenon monitoring systems have been under development and testing for the verification of the Comprehensive Nuclear Test-Ban Treaty (CTBT). Operation of the systems since then has resulted in development of a next-generation of systems that are nearly ready for operational deployment. By 2010, the need to screen out civilian sources was well known (Auer et al., 2010; Saey, 2009), and isotopic ratio approaches were soon considered (Kalinowski et al., 2014) to identify specific sources. New generation systems are expected to improve the ability to verify the absence of nuclear tests by using isotopic ratios when multiple isotopes are detected. In this work, thousands of releases were simulated to compute the global detection probability of 131m Xe, 133m Xe, 133 Xe, and 135 Xe at 39 noble gas systems in the International Monitoring System (IMS) for both current and next-generation systems. Three release scenarios are defined at 1 h, 1 d, and 10 d past a 1 kt TNT equivalent 235U explosion event. Multiple cases using from one part in a million to the complete release of the xenon isotopic activity are evaluated for each scenario. Coverage maps and global integrals comparing current and next-generation monitoring systems are presented showing that next-generation noble gas systems will create measurable improvements in the IMS. The global detection probability for 133 Xe is shown to be strong in all scenarios, but only modestly improved by next-generation equipment. However, the detection probability for 131m Xe and 133m Xe increased to about 50% in different scenarios, providing a second detectable isotope for many events. As anticipated from shorter sampling intervals, the expected number of detecting samples roughly doubled and the expected number of detecting stations rose by approximately 50% for all release scenarios. Thus, it might be anticipated that future events would consist of multiple 133 Xe detections and one or more second isotope detections. In conclusion, signals of this nature should increase detection confidence, tighten release location estimates, improve rejection of civilian signals, and lessen the impacts from individual systems being offline for maintenance or repair reasons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Refining Methods to Determine the Isotopic Composition of Uranium Particles by Laser Ablation MC-ICP-MS

We report on efforts to mitigate the generation of isotopic anomalies during the ablation of micrometer-sized uranium oxide particles and analysis by MC-ICP-MS. The results of testing on particles of U200 indicate that laser fluence and frequency can affect isotopic data produced by laser ablation, but no settings were tested that could eradicate the signal spiking effect and generation of anomalous isotopic data for 234U/238U and 236U/238U. These anomalies are more frequent in samples with higher 235U enrichments, which is expected given their higher abundances of 234U and 236U. Of the standards tested here, only U005-A was anomaly-free. Efforts to compare the laser traces for particles with normal and anomalous isotopic compositions showed subtle differences in the behavior of the 234U/238U and 236U/238U ratios. However, it would be challenging to identify anomalous data points from a population of unknowns using this distinction, i.e., this is unlikely to be diagnostic. Thus, using current analytical hardware, we cannot eradicate the signal spiking phenomenon and cannot unambiguously identify isotopic anomalies from laser ablation traces. Ultimately, laser ablation ICP-MS would either require dramatic improvement to the ablation process and generation of more homogenous aerosols and/or improvements to detector electronics to identify and correct for the spiking phenomenon. Even if the reliability of the technique could be improved, a broader question to address is whether current data quality is of a high enough standard for laser ablation MC-ICP-MS to be used as a complementary technique to LG-SIMS for Safeguards.

organic↗

Compact assembly for production of medical isotopes via photonuclear reactions

The invention provides a method for generating medical isotopes, the method comprising contacting a primary radiation beam with a converter for a time sufficient to produce a secondary beam of gamma particles, and contacting the beam of gamma particles to a target, where the cross section dimension of the beam of gamma particles is similar to the cross section dimension of the target. Both the converter and target are small in diameter and very closely spaced. Also provided is a system for producing medical isotopes, the device comprising a housing having a first upstream end and a second downstream end, a radiotransparent channel (collimator) with a first upstream end and a downstream end, wherein the upstream end is adapted to receive a radiation beam, a target positioned downstream of the downstream end of the channel and coaxially aligned with the channel, wherein the target has a cross section that is similar to the cross section of the channel.

Nolen, Jr., Jerry A.↗

Improvements of Nuclear Data Evaluations for Lead Isotopes in Support of Next Generation Lead-Cooled Fast Systems

The neutron evaluation of the isotopes that comprise natural lead were undertaken as a part of DOE-NEUP Project #19-16739. The goal of the project was to update the neutron cross sections to account for new differential measurements and incorporate the most up-to-date physics. Shortcomings in the lead cross sections was made known by several independent reports. The work performed here repeated the simulation of all the “benchmark” validation systems and concluded that the major issue is the scattering cross sections in the major lead isotopes above 100 keV. Re-evaluation of 206,207,208 Pb included both the resolved resonance region and fast region evaluations of the cross sections. Combined these regions cover energies from thermal to 20 MeV. The most drastic improvement is the resolved resonance region evaluation of 208 Pb which is now extended from 1.0 to 1.5 MeV. Parameterization of these resonances in the R-matrix provides a superior reconstruction of not only the experimental cross section but also the scattering distributions via the Blatt-Biedenharn formalism. Fast region evaluations of the three major isotopes were done to include new inelastic experimental data from the neutron Time-of-Flight facility at CERN. The culmination of all the changes to the cross section is a drastic improvement in the scattering kernel as shown in Rensselaer Polytechnic Institute (RPI) Quasi-Differential scattering measurements and improved prediction of keff for fast integral experiments. Alongside the new cross sections, new nuclear data covariance (uncertainties) have been computed and are included in the evaluation. Little is changed in the magnitude of the uncertainties but the correlations within the covariance display non-trivial changes. The new evaluations of 206,207,208 Pb have been submitted to the National Nuclear Data Center to be included in the ENDF/B-VIII.1 library. While the cross sections have been updated extensively, knowledge and modeling of the cross sections between 1.0 and 3.0 MeV for the isotopes remain a challenge. Most notably is the double differential elastic cross section for 208 Pb and 206 Pb. New quasi-differential measurements for pure samples of these two nuclei would go a long way in reducing compensating errors in the evaluations. Qualitatively, the project has produced a prosperous collaboration between the nuclear data group at RPI with staff scientists at Brookhaven National Laboratory, Naval Nuclear Laboratory, Oak Ridge National Laboratory, Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratories. Quantitatively this is reflected in seven conference presentations, at least one journal submission, and one doctoral thesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Systematic Investigation of the Effects of Standard-Sample Concentration Mismatch during Fe Isotope Measurement by MC-ICP-MS

Advances in multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) have led to the widespread use of iron (Fe) isotopes to elucidate the (bio)geochemical history of a range of environments. To generate Fe isotope ratio measurements, standard-sample bracketing (SSB) is commonly used to correct for instrumental mass bias inherent to MC-ICP-MS. However, SSB is only accurate when sample and isotope standard Fe concentrations match, in addition to the bulk solution matrix. When the Fe concentrations differ, Fe isotope ratio measurement results may be inaccurate, a phenomenon known as the "self-induced matrix effect." Here, this study systematically characterised the self-induced matrix effect for dry plasma Fe isotope ratio measurements on three MC-ICP-MS instruments and three introduction systems. Our extensive dataset indicates that: (1) the degree of mass bias is consistent regardless of MC-ICP-MS front-end design, (2) the degree of mass bias becomes less reproducible as the concentration difference between the sample and bracketing standard increases, and (3) this applies to both pure Fe solutions and solutions from geological materials. This study reinforces the requirement to match bracketing standard and sample concentrations within 10% and provides a correction method for that fall beyond the recommended concentration range to subsequently allow for proper concentration matching during SSB.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Evolution of Radioisotope Thermal Generators (RTG)

Introduction The advancement of space exploration owes a lot to the development of nuclear power in space. The Radio Isotopic thermal generator (RTG) was first invented in 1954 and earned its place in the inventor’s hall of fame in 2015. The RTG was and still it the key to our success in the exploration of deep space

Belian, Olivian↗

Advanced Design for the WIQ Magnet With Steering Corrector Function

The Facility for Rare Isotopes Beams (FRIB) delivers heavy-ion primary beams at energies of up to 300 MeV/u at 10 kW of beam power to generate rare isotope beams for experiments and will eventually operate at beam power of 400 kW. The preseprator of the Advanced Rare Isotope Separator (ARIS) is equipped with six warm-iron quadrupole (WIQ) singlets and two dipoles integrated right after the production target. They have a compact structure and operate in a high radiation vacuum environment within a hot cell having remote handling capabilities for installation and maintenance. Due to asymmetry with respect to the quadrupole poles, nested sextupole excitations in WIQs induce vertical dipoles that offset the centroid trajectory; Magnet misalignments also result in trajectory offsets. Such offsets degrade separator performance but can be minimized by changing the current distribution on sextupole and octupole coils. In this work, we show how modifications to the WIQ coil design can allow superimposed dipole fields to be included to the octupole and sextupole windings, as well as addition of dipole components by splitting coil currents over groups with separator power supplies. Adjusting the group currents can cancel the sextupole-induced vertical dipole component which can be as high as 0.012 Tm. Octupole coil changes may superimpose a horizontal dipole integrated strength as high as 0.0332 Tm. Unwanted higher harmonics induced as a side effect of the new design are kept to a minimum such that separator performance is preserved as much as possible.

Accelerator magnets↗

The Evolution of of Radioisotope Thermal Generators

Introduction The advancement of space exploration started in 1957 with the launch of Sputnik 1 which was quickly followed by the launch of Explorer 1 in 1958. The advancement in space exploration had much to do about the development of nuclear power in space. Enabling satellites to draw more power than before and carry out long term mission. The Radio Isotopic thermal generator (RTG) was first invented in 1954 and earned its place in the inventor’s hall of fame in 2015. The RTG has been the key to our success in the exploration of deep space. With in this paper the evolution of the RTG will be covered including the missions they facilitated. In addition, the ever present political and public view of nuclear material will play a role in the history of the RTG and the modern possibilities for nuclear power in space.

Belian, Olivia↗

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗