Search NASA⌕ Search

SEARCH · Search NASA

Results for “Kr irradiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Insights into Prismatic Loop Formation in Irradiated Fe–Cr Alloys from Hypothesis-Driven Active Learning and Causal Analysis

Neutron and electron irradiation experimental studies conducted on body-centered cubic Fe and Fe–Cr alloys have established two prismatic dislocation loop populations, which have Burgers vectors of either a/2$\langle$111$\rangle$ or a$\langle$100$\rangle$. Here, the loop formation depends on factors such as dose (D), dose rate (D rt ), temperature (T), chromium content (Cr%), and other alloying elements. Hence, it is important to understand how irradiation-induced dislocation loops evolve conditional upon the loop characteristics, such as loop density (DD), average loop size d̅, and irradiation parameters (D, D rt , T, and irradiation type), which is still an active area of research. To understand these complex structure–property relationships, machine learning (ML) is employed in a three-step approach. This includes imputing missing data with a k-nearest neighbor, generating functionalized features, and assessing feature importance with random forest classification and regression. Physics-based features are incorporated in a hypothesis-driven active learning scheme to overcome data unavailability challenges. Insights obtained from ML models (i) to categorize dislocation loop types, show the highest correlation with d̅; (ii) Log(DD), obtained through mathematical formulations involving D, Cr%, d̅, and T (e.g., Log(DD) ~ D + exp(-Cr%) + 1/d̅ and log(DD) ~ D + exp(-Cr%) + 1/T). Hypothesis-driven active learning is able to predict Log(DD) in which the experimental date is not known. Causal models verify cause–effect relationships for dislocation loop classification and irradiation factors in FeCr alloys.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of in-situ and ex-situ ion-irradiated additively manufactured 316L and 316H stainless steels

Additively manufactured (AM) 316 stainless steel (SS) differs from its wrought counterpart in its unique dislocation cell structure and the presence of segregation and oxide particles at the cell walls. This work investigated the evolution of the microstructure in laser powder bed fusion (LPBF) 316L and 316H SS under in-situ 1 MeV Kr ion irradiation at 600 °C to 5 dpa, and ex-situ 4 MeV Ni ion irradiation at 300 °C and 600 °C from 0.2 dpa to 10 dpa, with a dose rate for all experiments of 10 -3 dpa/s. The results reveal that the dislocation cell structure results in heterogeneous formation of dislocation loops and voids, particularly at 600 °C, where loops tend to form within the cell interiors while voids form at the cell boundaries. LPBF 316H has a reduced level of swelling compared to LPBF 316L due to prolonged incubation. Energy Dispersive X-ray Spectroscopy (EDS) mapping indicates Ni and Si segregation at void surfaces due to radiation-induced segregation. At 300 °C, where voids are absent, the distribution of dislocation loops and stacking fault tetrahedra appears to be uniform. Dislocation cell structures mostly disappeared by 2 dpa for all conditions in this work. M 23 C 6 carbides were observed in LPBF 316H at 600 °C as early as 0.2 dpa, but not in LPBF 316L. Nanoindentation was performed to obtain the hardness of irradiated materials. In conclusion, this work illustrated the influence of additive manufacturing processes on microstructure evolution under irradiation, revealing the differences as well as the similarities as compared with wrought 316 SS, and the AM-related phenomenon that can potentially occur under neutron irradiation in nuclear reactors.

36 - MATERIALS SCIENCE↗

Temperature dependence of irradiation-induced nanocrystallization in amorphous silicon carbide

Ion irradiation induced nucleation and growth in amorphous SiC at elevated temperatures are investigated in this study. Both as-deposited amorphous and Kr ion irradiation-amorphized SiC films are used for the investigation. Similar behavior of particle precipitation in the two types of the films is observed. It is found that the threshold temperature for nucleation is between 550 and 700 K, which is considerably higher than the critical temperature for full amorphization in SiC irradiated with Kr ions. There is a temperature regime up to at least 900 K, where the growth rates are only weakly dependent of the irradiation temperature. This temperature regime is potentially useful to tailor the size and density of nanocrystalline SiC precipitates by optimizing the ion irradiation conditions.

Ion irradiation, Nucleation and Growth, Silicon Ca↗

Effect of stacking fault energy on damage microstructure in ion-irradiated CoCrFeNiMn concentrated solid solution alloys

In order to understand the effect of stacking fault energy on microstructural evolution in concentrated solid solution alloys, Kr 2+ ion irradiation was performed for FCC-type CoCrFeNiMnx alloys. During Kr 2+ ion irradiation at 500 degrees C the formation of black dots, self-interstitial atom faulted loops and perfect loops were observed, but no observable voids were found in all the alloys. The comparison of microstructural evolution among CoCrFeNiMn x (x = 0.7, 1, 1.3) alloys revealed less faulted loop number density and size in CoCrFeNiMn 1.3 . The stacking fault energy of each alloy was investigated using the deformed CoCrFeNiMn x alloys, and it was revealed that CoCrFeNiMn 1.3 had the highest stacking fault energy, which is higher value than that of 316SS. From these results, it is suggested that FeCrNiMn-based concentrated solid solution alloys could be well-designed by controlling the stacking fault energy with optimized Mn concentration as one of high radiation resistance structure materials. (C) 2020 Elsevier B.V. All rights reserved.

36 MATERIALS SCIENCE↗

In situ study on radiation response of tungsten manufactured by laser powder bed fusion

Tungsten (W) produced by laser powder bed fusion (LPBF) was examined by in situ Krypton (Kr) ion irradiation at 400 °C up to 2.52 displacements per atom (dpa) to investigate its radiation response. Dislocation loops with identical Burgers vectors form aligned raft structures, inducing significant grain misorientation accumulation. Defect saturation was observed beyond 0.36 dpa, marked by constant loop density and raft spacing. WO 3 nanoparticles are found in the as-printed matrix and served as efficient defect sinks. Dislocation loops were absorbed at the W/WO 3 interface, facilitating defect annihilation and suppressing defect accumulation. In conclusion, these findings highlight the role of LPBF microstructure and oxide interfaces in mediating radiation-induced defect evolution, offering insights for designing radiation tolerant W-based materials.

Defect sink↗

Measuring sub-surface spatially varying thermal conductivity of silicon implanted with krypton

The thermal properties of semiconductors following exposure to ion irradiation are of great interest for the cooling of electronic devices; however, gradients in composition and structure due to irradiation often make the measurement difficult. Furthermore, the nature of spatial variations in thermal resistances due to spatially varying ion irradiation damage is not well understood. In this work, we develop an advancement in the analysis of time-domain thermoreflectance to account for spatially varying thermal conductivity in a material resulting from a spatial distribution of defects. We then use this method to measure the near-surface (≲1 μm) thermal conductivity of silicon wafers irradiated with Kr + ions, which has an approximate Gaussian distribution centered 260 nm into the sample. Our numerical analysis presented here allows for the spatial gradient of thermal conductivity to be extracted via what is fundamentally a volumetric measurement technique. We validate our findings via transmission electron microscopy, which is able to confirm the spatial variation of the sub-surface silicon structure, and provide additional insight into the local structure resulting from the effects of ion bombardment. Thermal measurements found the ion stopping region to have a nearly 50x reduction in thermal conductivity as compared to pristine silicon, while TEM showed the region was not fully amorphized. Our results suggest this drastic reduction in silicon thermal conductivity is primarily driven by structural defects in crystalline regions along with boundary scattering between amorphous and crystalline regions, with a negligible contribution being due to implanted krypton ions themselves.

36 MATERIALS SCIENCE↗

Mechanisms of ion irradiation induced ordering in amorphous TiO 2 nanotubes: Effects of ion mass and energy

Here, amorphous TiO 2 nanotubes were irradiated in-situ in a transmission electron microscope (TEM) with Kr + ions at energies of 46 keV, 150 keV, and 1 MeV and with 46 keV Xe + ions, to investigate the structural and morphological evolution of the nanotubes under irradiation. At all irradiation conditions, amorphous TiO 2 nanotubes exhibited significant morphological instability, and tended to undergo volumetric swelling with increasing ion counts, often until collapse of the original nanotube structure. Molecular dynamics (MD) simulations confirmed that irradiation-induced defects can explain the observed swelling. Structurally, nanotubes remain amorphous following all Kr + irradiation conditions, but irradiation with 46 keV Xe + leads to the formation of anatase nanocrystallites. Importantly, through systematically varying ion energy and ion species, we try to elucidate the influence of nuclear and electronic stopping power on ion irradiation induced changes. By contextualizing these results within the existing literature, we propose that the observed changes in TiO 2 nanotube morphology and structure could be due to a competition between two mechanisms: (1) disorder-induced swelling and (2) irradiation-induced amorphous-to-crystalline transformation.

36 MATERIALS SCIENCE↗

Synthesis and ion-irradiation tolerance of the Dy2TiO5 polymorphs

In developing improvements in nuclear fuels, work has been conducted in replacing boron with lanthanides to act as neutron absorbent materials. To further this development for the first time the three major polymorphs of Dy2TiO5 have been fabricated as bulk, single-phase materials in a systematic study. Crystal structure refinement has been carried out from powder x-ray diffraction data, with further structural detail attained via electron diffraction. A cubic phase, defect-pyrochlore, Fd-3m space group, was found with cell parameter a = 10.2996 (1) angstrom and oxygen x48f positional parameter = 0.331 (1). Dy2TiO5 was also fabricated as a bulk, single-phase compound with hexagonal symmetry, P6(3)/mmc space group, with cell parameters a = b = 3.6307(2), c = 11.8963(8) angstrom. The radiation response for each of the polymorphs has been investigated in-situ via 1 MeV Kr - ion-irradiation and transmission electron microscopy characterisation at the IVEM-TANDEM facility, Argonne National Laboratory. Critical temperatures, T-c, for maintaining crystallinity during irradiation were determined and showed Dy2TiO5 with either orthorhombic or cubic symmetry to perform the best, with the lowest T-c values of 711 and 761 K respectively when compared with the hexagonal form. These relatively low T-c values may be attributed to different characteristics for each phase; high anti-site defect formation energy for the orthorhombic symmetry, and the ability to accommodate disorder for the cubic symmetry.

Burnable poison↗

In situ transmission electron microscopy with dual ion beam irradiation and implantation

To study the helium effects and their interactions with displacement damage in irradiated materials, an in situ dual-ion beam irradiation capability with transmission electron microscopy was recently established at the IVEM-Tandem Facility at Argonne National Laboratory. Pure nickel was irradiated in situ individually with 1 MeV Kr ions for displacement damage study, 16 keV He ions for helium implantation, and simultaneously with 1 MeV Kr ions and 16 keV He ions at the rate of 1 at.% He/dpa to study the interaction of helium and displacement damage at 500 degrees C. Helium bubbles were formed and segregated within dislocation loops during the He implantation experiment and no bubbles were observed outside the loops. The loop size increased with increasing helium concentration. In contrast, helium bubbles were formed uniformly in the matrix when nickel was irradiated simultaneously with 1 MeV Kr ions and 16 keV He ions. Overall, it is suggested that the uniformly-distributed defect clusters formed under 1 MeV Kr ion irradiation serve as trapping sites of helium atoms resulting in homogeneous nucleation of helium bubbles under the dualion beam irradiation in nickel.

36 MATERIALS SCIENCE↗

Ta–Zr carbides: Synthesis advances via carbothermal reduction and defect evolution observed through transmission electron microscopy ion irradiation

The thermodynamic stability of six distinct compositions within the Zr—Ta—C ternary system is investigated in this study, marking the first report of their synthesis through carbothermic reduction in vacuum. A prolonged annealing process at 2200°C enabled high densification and phase equilibrium. Detailed phase identification and microstructural characterization through microscopy and X-ray diffraction techniques revealed clear compositional trends and stable phase formations. Two compositions ((Ta 0.2 Zr 0.8 )C 0.6 and (Ta 0.5 Zr 0.5 )C 1 ) were selected for ion irradiation experiments using 200 keV Kr + at 600°C—representing the first-ever irradiation study on the Zr—Ta—C system. The findings indicated defect accumulation and nanoscale cavity formation without any evidence of amorphization, highlighting the system's structural stability under irradiation. Together, the synthesis and irradiation results provide a basis for further investigation of the system and suggest its relevance for applications under extreme environments.

36 MATERIALS SCIENCE↗

Helium co-implantation effects on dislocation loop evolution during in situ ion irradiations of a novel additive-manufactured Fe-9Cr steel alloy

This study examines the impact of helium injection rate on dislocation loop evolution during ion irradiation of a novel, additively manufactured (AM) 9Cr reduced-activation ferritic/martensitic (RAFM) steel. Through in situ transmission electron microscopy ion irradiations and post-irradiation characterization, the effects of simultaneous 1 MeV Kr²⁺ and 12 keV He⁺ ion irradiation at 400°C to 5 dpa with varying helium levels were examined. The findings reveal that helium co-injection significantly increases dislocation loop density, primarily through the formation of small defect features exhibiting contrast and projected morphologies consistent with a⟨100⟩ loops (∼1 nm), while suppressing larger a/2⟨111⟩ loops. The findings underscore the complex interplay among continuously increasing helium content, temperature, and alloy composition in the evolution of dislocation loops under irradiation in RAFM steels. The study highlights the need for further investigation into helium-mediated mechanisms, such as proposed interactions between self-interstitial atoms and helium atoms, to enhance the performance of RAFM steels in advanced nuclear reactors.

ANA2↗

Dynamic observation of dual-beam irradiated Fe and Fe-10Cr alloys at 435 °C

The attractive mechanical properties and superior resistance to void-swelling make ferritic/martensitic alloys a promising structural material for advanced nuclear reactors. However, one anomaly that has intrigued researchers for more than 50 years is the proportion of two types of dislocation loops in Fe and Fe-Cr alloys with Burger vectors b=½<111> and b=<100>. Although the possible mechanisms responsible for the presence of <100> loops continue to be the subject of intense modeling studies, there remains incomplete experimental understanding of fundamental irradiation processes in Fe(Cr) alloys. Here, the dose dependence of the irradiation-induced microstructural evolution was examined from 0 to 20 displacement per atom (dpa) in high purity Fe and Fe-10Cr during simultaneous dual-beam (1 MeV Kr + 10 appm He/dpa) irradiation at 435 °C. We experimentally revealed that the mechanism for the formation of <100> loops may not follow the conventional simple dislocation reaction between two 1½<111> loops. Real-time dynamic formation and evolution of defects including black dot loops, loop coarsening, loop decoration, network dislocations, and cavities were demonstrated. Several results indicated that the addition of Cr and He could impede dislocation loop motion. The evolution of the defect size/density and relative fraction of ½<111> vs <100> loops were quantitatively summarized. With increasing dose, ½<111> loops became the dominant type of loop in both materials. Notably, <100> loops were predominantly observed near grain boundaries only for pure Fe, while arrays of nanoscale black dot defects composing the <100> loop strings were observed in plenty in Fe-10Cr.

36 MATERIALS SCIENCE↗

Radiation induced amorphization of carbides in additively manufactured and conventional ferritic-martensitic steels: In-situ experiments on extraction replicas

In-situ irradiations using 1 MeV Kr 2+ ions in a transmission electron microscope were performed on extraction replica samples containing M 23 C 6 carbides and MX carbonitrides from two ferritic-martensitic (FM) steels: (i) 9%Cr-1%W-TaV based Eurofer97 and (ii) 9%Cr-1%Mo-VNb (all in wt.%) based additively manufactured (AM) Grade91 steel. The irradiations were performed between 100 and 773 K up to a maximum dose of ~2.4 displacements per atom (dpa). The M 23 C 6 carbides are highly susceptible to radiation induced amorphization (RIA), while the MX type nanoprecipitates are highly amorphization resistant across the entire irradiation temperature range. Between 100 and 423 K, RIA of M 23 C 6 carbides occurs very rapidly with critical amorphization doses ranging between ~0.35 and 0.9 dpa, increasing to higher doses at 573 K. Complete amorphization of the M 23 C 6 carbides up to doses of ~2.4 dpa is not possible at 773 K under the present irradiation conditions. The critical amorphization dose of M 23 C 6 carbides increases nearly exponentially with irradiation temperature. The critical temperature for the crystalline-to-amorphous phase transformation (T c→a ) of M 23 C 6 carbides irradiated as replica samples, i.e. without the surrounding metal matrix, was estimated to be ~812 K. Comparing the present results with neutron irradiation data on bulk samples reveals a decrease in the critical amorphization dose for M 23 C 6 and an increase of T c→a , highlighting the effect of dose rate on the amorphization behavior that is qualitatively consistent with literature on other non-metals. Changes in the minor chemistry of M 23 C 6 , such as presence or absence of W, V, Nb, Mo, seems to have little effect on the amorphization behavior. Here, in-situ irradiations on extraction replica samples provide a novel pathway to explore radiation tolerance of nanoprecipitates in nuclear structural materials

36 MATERIALS SCIENCE↗

Effect of sink strength on coherency loss of precipitates in dilute Cu-base alloys during in situ ion irradiation

In situ irradiations with 1 MeV Kr ions at 50~613 K up to a fluence of 6.25 × 10 14 ions/cm 2 (~1.25 displacements per atom, dpa) have been performed on pre-aged dilute Cu-0.9%Co, Cu-0.9%Fe and Cu-0.8%Cr alloys containing uniform matrix dispersions of coherent precipitates in order to study the effects of initial precipitate sink strength, damage dose and irradiation temperature on radiation-induced coherency loss of precipitates. Coherent precipitates with different point defect sink strengths (2πNd, where N and d are the precipitate density and diameter) were used in this work to examine potential differences in atomic relaxation during absorption of point defects. In all cases, irradiation to low doses (<~1 dpa) was very effective at inducing loss of precipitate coherency. At low sink strengths (~10 13 m -2 ), loss of precipitate coherency could be induced for doses ~0.01 dpa. This suggests there might be an efficient preferential medium-range strain-induced bias for absorption of interstitial defects due to tensile strains emanating from the undersized precipitates, which induces relatively rapid loss of coherency at low precipitate sink strengths. High precipitate sink strength (~10 14 m -2 ) conditions were relatively resistant to the radiation-induced loss of coherency (requiring higher doses approaching ~1 dpa) and this might be due to nearly equal numbers of interstitial and vacancy defects arriving at the precipitate interface for such high sink strength conditions. The precipitate coherency loss was observed to have a weak dependence on irradiation temperature. Molecular dynamics simulations confirm a strong effect of precipitate sink strength on the probability of interstitial absorption at precipitates.

36 MATERIALS SCIENCE↗

Surprisingly high irradiation-induced defect mobility in Fe 3 O 4 as revealed through in situ transmission electron microscopy

Radiation-induced defects are expected to change the corrosion kinetics when a material is exposed to a corrosive environment. Characterization of the defects forming under irradiation and their ability to move/diffuse is therefore key to understanding how they impact the corrosion kinetics and possibly mechanisms. For that matter, Fe/Fe 3 O 4 interfaces were irradiated using 1 MeV Kr 2+ at temperatures of 273 K (25 °C), 573 K (300 °C) and 773 K (500 °C) to a maximum dose of 10 dpa (as measured in the Fe matrix) in situ in a transmission electron microscope. The evolution of the microstructure was followed as a function of the dose and temperature. The formation of defects was followed in the metal and the oxide as well as at the metal/oxide interface and characterized in terms of size and density. Additionally, the dynamic observation of the spatial distribution of the defects allowed for a qualitative assessment of the mobility of defects in the oxide as a function of temperature, revealing evidence for enhanced mobility even more so than in the Fe matrix. Mechanisms of induced defect mobility in the spinel are discussed to account for the observations.

36 MATERIALS SCIENCE↗

Trapping of noble gases in proton-irradiated silicate smokes

We have measured Ne, Ar, Kr, and Xe in Si2O3 'smokes' that were condensed on Al substrates, vapor-deposited with various mixtures of CH4, NH3, H2O3 and noble gases at 10 K and subsequently irradiated with 1 MeV protons to simulate conditions during grain mantle formation in interstellar clouds. Neither Ne nor Ar is retained by the samples upon warming to room temperature, but Xe is very efficiently trapped and retained. Kr is somewhat less effectively retained, typically depleted by factors of about 10-20 relative to Xe. Isotopic fractionation favoring the heavy isotopes of Xe and Kr of about 5-10-percent/amu is observed. Correlations between the specific chemistry of the vapor deposition and heavy noble gas retention are most likely the result of competition by the various species for irradiation-produced trapping sites. The concentration of Xe retained by some of these smokes exceeds that observed in phase Q of meteorites and, like phase Q, they do not seem to be carriers of the light noble gases.

Nichols, R. H., Jr.↗

Cosmic-ray-produced Kr in St. Severin core AIII

Kr isotopic abundances in 10 samples from core AIII of the St. Severin chondrite are reported, and the variation with depth of cosmic-ray produced Kr is discussed. It is shown that the ratio (Kr-78/Kr-83)c changes with depth and can be used as an irradiation hardness monitor. Cosmic-ray-produced Kr and Ne in the St. Severin core are compared with ratios observed in bulk chondrites. A linear correlation between (Ne-22/Ne-21)c and (Kr-78/Kr-83)c exists for bulk samples of chondrites of varying preatmospheric size, but does not exist in the St. Severin core. The calculated Kr-83 production rates, P83, are similar in H, L, and LL chondrites for samples of comparable shielding conditions. However, P83 rates increase by a factor of about 2 with shielding depth. The maximum observed P83 values correspond to (Kr-78/Kr-83)c factor of about 2 with shielding depth. The maximum observed P83 values correspond to (Kr-78/Kr-83)c less than about 0.14.

Lavielle, B.↗