Search NASA⌕ Search

SEARCH · Search NASA

Results for “LABS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Managing autonomous materials labs with multi-agent AI and its implications for the science of science

Self-driving lab systems (aka, autonomous experimentation) accelerate research - letting scientists learn faster, spend less resources, and fail smarter in well defined, narrow studies. The next-generation materials lab combines self-driving systems to tackle broader challenges - orchestrating complex research campaigns while optimizing lab resources. We propose that agent-based and agentic artificial intelligence will be an integral part of next-generation lab management and discuss potential implementation scenarios. Additionally, digital and physical sandboxes will allow scientists to evaluate diverse and dynamic research and lab management strategies. Beyond the immediate benefit to lab optimization, such sandboxes will enable realistic computational studies of the philosophy of science (i.e., science of science) to achieve higher level scientific efficiencies.

Computer science↗

Enhancements to Lab-on-a-Fish Technology: Final Report for I3T Project 81245

PNNL has engaged in discussions with several organizations regarding potential future collaborations. PNNL has developed the Lab-on-a-Fish prototypes and produced video instructions for an organization conducting research on shark eggs. Several organizations have expressed interest in using the Lab-on-a-Fish for their studies. We’ve also updated two versions of the Lab-on-a-Fish to expand its applications to a wider range of animal studies and accelerate its commercialization. The new design of the Lab-on-a-Fish, which incorporates PCB-based electrodes, has demonstrated the ability to capture clear ECG signals without the need for additional needle-shaped electrodes. This innovation eliminates the need for implanting electrodes beneath the fish's skin at specific locations, which is required with the current version of Lab-on-a-Fish. This change significantly simplifies the manufacturing and implantation process. For the Lab-on-a-Fish design that uses an optical pulse oximeter, the measurement results were primarily influenced by respiratory activity rather than heart rate. This occurred because the oximeter was placed beneath the operculum. Further research and development are needed to explore more suitable locations and methods for accurate pulse oximeter measurements.

59 BASIC BIOLOGICAL SCIENCES↗

Federated Access from DOE Labs to Distributed Storage in the EIC Era of Computing

The Electron Ion Collider (EIC) collaboration and future experiment is a unique scientific ecosystem within Nuclear Physics as the experiment starts right off as a crosscollaboration between Brookhaven National Lab (BNL) & Jefferson Lab (JLab). As a result, this muti-lab computing model tries at best to provide services accessible from anywhere by anyone who is part of the collaboration. While the computing model for the EIC is not finalized, it is anticipated that the computational and storage resources will be made accessible to a wide range of collaborators across the world. The use of federated ID seems to be a critical element to the strategy of providing such services, allowing seamless access to each lab site computing resources. However, providing Federated access to a Federated storage is not a trivial matter and has its share of technical challenges. In this contribution, we focus on the steps we took towards the deployment of a distributed object storage system that integrates with Amazon S3 and Federated ID. We will first cover for and explain the first stage storage solutions provided to the EIC during the detector design phase. Our initial test deployment consisted of Lustre storage using MinIO, hence providing an S3 interface. High Availability load balancers were added later to provide the initial scalability it lacked. Performance of that system will be shown. While this embryonic solution worked well, it had many limitations. Looking ahead, the Ceph object storage is considered a top-of-the-line solution in the storage community - since the Ceph Object Gateway is compatible with the Amazon S3 API out of the box, our next phase will use a native S3 storage. Our Ceph deployment will consist of erasure coded storage nodes to maximize storage potential along with multiple Ceph Object Gateways for redundant access. We will compare performance of our next stage implementations. Finally, we will present how to leverage OpenID Connect with the Ceph Object Gateway’s to enable Federated ID access. We hope this contribution will serve the community needs as we move forward with cross-lab collaborations and the need for Federated ID access to distributed compute facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Work function lowering of LaB 6 by monolayer hexagonal boron nitride coating for improved photo- and thermionic-cathodes

We report a lowering of work function for lanthanum hexaboride (LaB 6 ) by monolayer hexagonal boron nitride (hBN) coating. Photoemission electron microcopy (PEEM) and thermionic emission electron microscopy (TEEM) both revealed that the hBN coated region of a LaB 6 (100) single crystal has a lower work function compared to the bare (i.e., non-coated) and graphene coated regions. A broad and uniform brighter image of the hBN coated region in PEEM was quantitatively supported by a 0.4 eV decrease in the work function in photoelectron spectra compared to the bare region. TEEM results were consistent in that the hBN coated region exhibited thermionic emission at 905 °C, whereas the bare and graphene coated regions did not. A larger decrease in the work function for hBN coated LaB 6 (100) compared to graphene coated LaB 6 (100) was qualitatively supported by our density functional theory calculations. Adding an oxide layer in the calculations improved consistency between the calculation and experimental results. We followed up our calculations with synchrotron-radiation x-ray photoelectron spectroscopy and confirmed the presence of an oxide layer on our LaB 6 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructure, mechanical, and thermal properties of compositionally complex (Hf,Zr,Nb,Ti)B 2 ‒LaB 6 ceramics

Novel compositionally complex borides, (Hf,Zr,Nb,Ti)B 2 and (Hf,Zr,Nb,Ti)B 2 ‒LaB 6 , were fabricated using spark plasma sintering process. (Hf,Zr,Nb,Ti)B 2 ‒LaB 6 exhibits a dual-phase microstructure, in which (Hf,Zr,Nb,Ti)B 2 is a primary phase with the hexagonal structure and LaB 6 is a secondary phase with a cubic structure. The mechanical properties of both (Hf,Zr,Nb,Ti)B 2 and (Hf,Zr,Nb,Ti)B 2 ‒LaB 6 are comparable, with a combination of high hardness and moderate fracture toughness. Thermal diffusivity and conductivity of (Hf,Zr,Nb,Ti)B 2 are much lower than the individual transition metal borides but are significantly increased by the addition of LaB 6 . Herein, it is implied that the thermal properties of boride ceramics can be controlled through the appropriate design of principal metal element compositions.

borides↗

Siting Lab [SWR-24-95]

Siting Lab contains a collection of user-friendly tutorials and guides for working with the Siting Lab (https://data.openei.org/siting_lab) data within the context of the reV model. The python code examples demonstrate the creation and transformation of Siting Lab data into reV compliant format as well as working with the reV model inputs and outputs. Specifically, Siting Lab provides a collection of Jupyter Notebooks that serve as guides for working with data from NREL's spatial analysis portfolio. These notebooks teach users how to create and interact with reV data in order to facilitate external use of the model. The guides in this repository reference NREL's Supply Curve data as well as Siting Lab spatial data available on OEDI.

Lopez, Anthony↗

Serendipitous discovery connects grandfather and granddaughter at the Lab 60 years apart A third-generation employee learns about Los Alamos family history

The Lab’s enduring mission work means staff like Cameron Townsend are one of many family members who have careers at LANL. Cameron is her family’s third generation to work at the Lab, starting with her great grandparents, followed by her grandparents (skipping her parents), and now including her and her husband. She didn’t know about her family history at the Lab until she started working here three years ago when a typical day on the job became a serendipitous window into her family’s long history with the Lab. Cameron, who is an architect in EPC-ES: Environmental Stewardship and helps manage the Lab’s historic buildings program, was given a drawing from 1960 to aid in an assessment. The drafter’s name on the sketch: Ron Turner, her grandfather.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of Thin Triple-Pane Windows in the PNNL Lab Homes

In recent years, improvements in glass manufacturing have allowed the production of thin triple-pane windows, which are manufactured with a thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy is sponsoring laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. To examine the performance of thin triple-pane windows, the Pacific Northwest National Laboratory (PNNL) evaluated the windows at the PNNL Lab Homes, a matched pair of homes located on PNNL’s campus in Richland, Washington. In this study, one Lab Home contained a complete set of nine thin triple-pane windows, while the other Lab Home contained baseline double-pane windows. The Lab Homes experiments demonstrated significant that replacing clear glass double-pane windows with thin triple-pane windows provided year-round energy savings and reduced peak demand both in the heating and cooling seasons. The Lab Homes experiments also validated other performance benefits of the thin triple-pane windows including reduced condensation potential, more even temperatures throughout the home and near the windows, and reduced sound attenuation through the windows, leaving the home quieter and more comfortable for the occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laboratory Efficiency Strategies and the Smart Labs Program

Focusing on critical spaces, such as labs, will enable agencies to prioritize federal energy efficiency and decarbonization goals. FEMP's Smart Labs program is an example of emerging efficient laboratory building strategies. The benefits of this program include improved safety and health, reduced energy consumption and carbon emissions, lower operating costs, reduced degradation, and increased retention and recruitment of top talent researchers and sciences. In this session, with the help of our national lab partners, Sandia National Laboratory and Lawrence Berkeley National Laboratory, you will learn about the steps to implement a Smart Labs program of your own and the methods behind the high-performance laboratory building. The partners will share best practices in implementation, practical advice for building a team, and how to address these critical facilities.

decarbonization↗

Multi-lab study on the pure-gas permeation of commercial polysulfone (PSf) membranes: Measurement standards and best practices

Gas-separation membranes are a critical industrial component for a low-carbon and energy-efficient future. As a result, many researchers have been testing membrane materials over the past several decades. Unfortunately, almost all membrane-based testing systems are home-built, and there are no widely accepted material standards or testing protocols in the literature, making it challenging to accurately compare experimental results. Further, in this multi-lab study, ten independent laboratories collected high-pressure pure-gas permeation data for H 2 , O 2 , CH 4 , and N 2 in commercial polysulfone (PSf) films. Equipment information, testing procedures, and permeation data from all labs were collected to provide (1) accepted H 2 , O 2 , CH 4 , and N 2 permeability values at 35°C in PSf as a reference standard, (2) statistical analysis of lab-to-lab uncertainties in evaluating permeability, and (3) a list of best practices for sample preparation, equipment set-up, and permeation testing using constant-volume variable-pressure apparatuses. Results summarized in this work provide a reference standard and recommended testing protocols for pure-gas testing of membrane materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

UEMtomaton: A Source-Available Platform to Aid in Start-up of Ultrafast Electron Microscopy Labs

The steady rise in the number of ultrafast electron microscopy (UEM) labs, in addition to the opacity and lack of detailed descriptions of current approaches that would enable point-by-point construction, has created an opportunity for sharing common methods and instrumentation for (for example) automating data acquisition to assist in efficient lab start-up and to learn about common and robust protocols. In the spirit of open sharing of methods, we provide here a description of an entry-level method and user interface (UI) for automating UEM experiments, and we provide access to the source code and scripts (source-available) for ease of implementation or as a starting reference point for those entering or seeking to enter the field (https://github.com/CEMSFlannigan/UEMtomaton/releases/tag/v1.0). Core instrumentation and physical connections in the UEM lab at Minnesota are described. Interface communication schemes consisting of duo server-client pairs between critical components – the optical delay stage and the UEM digital camera – are presented, with emphasis placed on describing the logic and communications sequence designed to conduct automated series acquisitions. An application designed and programmed with C++/CLI as Windows Forms in Microsoft Visual Studio – dubbed UEMtomaton – is also presented. Key to the UI layout is centralization of the automation tasks and establishment of communication within the software rather than by interfacing with each individual workstation. It is our hope that this note provides useful insight for current and future UEM researchers, particularly with respect to generalizability and portability of the approach to emerging labs. Here, we note that while this basic, entry-level approach is certainly not the most sophisticated or comprehensive of those currently in use, we feel there is nevertheless value in clearly communicating a proven straightforward method to hopefully lower the barrier to entry into the field.

47 OTHER INSTRUMENTATION↗

Thermal expansion of LaB 6 from 298 to 998 K

We propose LaB 6 as a temperature calibration standard for high-temperature (HT) X-ray diffractometry owing to its high temperature stability. Such HT applications require a reliable HT lattice parameter or, equivalently, peak position data, which have not been readily accessible to the diffraction community to date. As such, the thermal expansion behavior of NIST SRM 660a LaB6 was assessed in the temperature range 298–998 K using HT Bragg–Brentano parafocusing θ:θ X-ray diffractometry in conjunction with Rietveld analysis. Data were collected in the 2θ range 20–150° at a data collection rate of 0.5° θ min −1 in air and at 1 atm. The temperature was stepped in 50 K increments. The cubic unit-cell lattice parameter [a(T)] of LaB 6 in Å was found to vary as a(T) = 4.15678 (±0.00001) + Ξ(T − 298 K) + Ψ(T − 298 K) 2 , where Ξ = 2.4645 × 10 −5 (±4.8904 × 10 −8 ) Å K −1 and Ψ = 1.0325 × 10 −8 (±6.7376 × 10 −11 ) Å K −1 . The isobaric volume thermal expansion coefficient (TEC) was obtained as α V P = (5.9291 × 10 −6 ) + (4.9680 × 10 −9 )(T − 298 K) K −1 , from which the corresponding linear TEC was obtained as α L P = (1.9764 × 10 −6 ) + (1.6560 × 10 −9 )(T − 298 K) K −1 . The 3 × 3 matrix representations of the single-crystal isobaric linear TEC and the volume expansivity were obtained for the cubic crystal class to which LaB 6 belongs. Also, the temperature dependence of the lattice parameter data of this study was compared with past landmark studies on LaB 6 by Dutchak et al. [Inorg. Mater. (1972), 8, 1877–1880] and Aivazov et al. [Inorg. Mater. (1979), 15, 1015–1016].

LaB6 standard material↗

Data for: Patel et al. Carbon flux estimates are sensitive to data source: A comparison of field and lab temperature sensitivity data

This dataset contains data and code used for the paper "Carbon flux estimates are sensitive to data source: A comparison of field and lab temperature sensitivity data" [DOI COMING SOON]A large literature exists on mechanisms driving soil production of the greenhouse gases CO2 and CH4. Measurements of these gases’ fluxes are often performed using closed-chamber incubations in the laboratory or in situ, i.e., in the field. Although it is common knowledge that measurements obtained through field studies vs. laboratory incubations can diverge because of the vastly different conditions of these environments, few studies have systematically examined these patterns. It is crucial to understand the magnitude and reasons for any differences, as these data are used to parametrize and benchmark ecosystem- to global-scale models, which are then susceptible to the biases of the source data. Here, we specifically examine how greenhouse gas measurements may be influenced by whether the measurement/incubation was conducted in the field vs. laboratory, focusing on CO2 and CH4 measurements. We use Q10 of greenhouse gas flux (temperature sensitivity) for our analyses, because of the ubiquity of this metric in biological and Earth system sciences and its importance to many modeling frameworks. We predicted that laboratory measurements would be less variable, but also less representative of true field conditions. However, there was greater variability in the Q10 values calculated from lab-based measurements of CO2 fluxes, because lab experiments explore extremes rarely seen in situ, and reflect the physical and chemical disturbances occurring during sampling, transport, and incubation. Overall, respiration Q10 values were significantly greater in laboratory incubations (mean = 4.19) than field measurements (mean = 3.05), with strong influences of incubation temperature and climate region/biome. However, this was in part because field measurements typically represent total respiration (Rs), whereas lab incubations typically represent heterotrophic respiration (Rh), making direct comparisons difficult to interpret. Focusing only on Rh-derived Q10, these values showed almost identical distributions across laboratory (n = 1110) and field (n = 581) experiments, providing strong support for using the former as an experimental proxy for the latter, although we caution that geographic biases in the extant data make this conclusion tentative. Due to a smaller sample size of CH4 Q10 data, we were unable to perform a comparable robust analysis, but we expect similar interactions with soil temperature, moisture, and environmental/climatic variables. Our results here suggest the need for more concerted efforts to document and standardize these data, including sample and site metadata. This dataset contains a compressed (.zip) archive of the data and R scripts used for this manuscript. The dataset includes files in .csv format, which can be accessed and processed using MS Excel or R. This archive can also be accessed on GitHub at https://github.com/kaizadp/field_lab_q10 (DOI: 10.5281/zenodo.7106554).

54 ENVIRONMENTAL SCIENCES↗

Early Lab scientists had questions, Plastic Man gave them answers

He was a willing subject in countless scientific experiments, a superstar of health physics, as well as a favorite photo prop -- and not just around Halloween time. He was Plastic Man. Beginning in the mid-1950s, the Lab (then called Los Alamos Scientific Laboratory) often relied on several life-sized synthetic test subjects to avoid experimenting on people. In the early days of the Laboratory, not much was known about how different radioisotopes interacted with the human body and how much it absorbed from different radiation sources. Answering queries like these is where Plastic Man came in. For example, during the 1950s and 1960s, the Lab was tasked with developing nuclear rockets for space exploration under the Rover Program. One of the concerns was how astronauts might be affected when exposed to radiation from these rocket engines. So, the Lab’s health group set up an experiment in which Plastic Man was placed in close proximity to an experimental Rover nuclear rocket engine. Running experiments like this using Plastic Man kept humans safer. How life-like was he? There were actually two variations of Plastic Man. Both had hard plastic exteriors, but one of the models encased a real human skeleton. They also had movable joints and simulated organs, such as a liver, a spleen, kidneys, lungs and a thyroid. Although Plastic Man in its entirety was used in experiments, much of the data collected were from research conducted inside on these replicated organs. In time, technology advanced and Plastic Man was able to retire from the Lab. He found a new home in 1964 as a display at the Laboratory’s science museum, and is sometimes displayed today in the Bradbury Science Museum in downtown Los Alamos.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Commuting again to work on-site? Lab’s first drivers faced their own challenges decades ago

After a long pause in commuting, more and more Lab staff are filling travel mugs, topping off their tanks, and heading up the hill for on-site work. As long as the Lab has existed, workers have snaked through tight mountain roads to get to their jobs. And, back in the early 1940s, drivers faced even more challenges. In the Lab’s earliest years, drivers likely worried about getting stuck in the mud, navigating intense switchbacks, or making sure important equipment, such as a disassembled power plant, didn’t fall off the back of the truck that was hauling it. Creative solutions could go a long way to get out of a jam. As many of us return onsite and get reacquainted with commuting, we look back at how transportation has changed since the Manhattan Project, the U.S. government’s top secret effort at Los Alamos to create the first atomic bombs to help end World War II. These stories and photos are part of the collections in the National Security Research Center, which is the Lab’s classified library and also houses unclassified artifacts from our past.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The WTP LAB stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the ANSI/HPS N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the DV of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The maximum 6 DV value from the scale model testing determines the maximum conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be = 20°. Second, the velocity uniformity at the full-scale stack must be = 20% COV. Finally, the velocity uniformity results for the actual and scale model stacks must agree within 5% COV. In general, these criteria were met through the full-scale stack tests at the LAB facility. Some specific items for each scale model and full-scale stack comparison should be noted in assessing the validity of the verification tests. The LB-C2 scale model stacks were performed with single fan operations at then-minimum flow conditions. These conditions resulted in DV values that were too low to meet the DV range criterion, and therefore are unable to be used in qualifying single fan operations on the full-scale stack. However, the single fan operations demonstrated COV values for velocity uniformity as well as flow angles that were comparable to the dual-fan operations at high flows. Overall, the test conditions and test results were within the range of acceptable values based on current design flow rates. Single fan operations are expected to only occur infrequently for maintenance needs and is therefore not a planned operating condition at this time. The LB-S1 scale model stacks were performed at three fan combinations, and in each combination, at least one test was performed at the then-minimum flow conditions as well as at then-maximum flow conditions. While the then-minimum flow conditions result in a DV range that is lower than the verification test DV value, and therefore does not meet the criterion, these tests are un-necessary for the verification test acceptance. The normal and maximum flow conditions from the scale model stack tests meet the DV range criterion, and the velocity uniformity test results compare favorably with the full-scale stack results. The LB-S2 scale model stacks were performed at nominally the same maximum flow condition; however, the 6 DV value for Fan A operation was slightly lower than the full-scale stack test DV. The COV values from the scale model stacks were comparable between the Fan A and Fan B results, and the overall test conditions are within the range of acceptable values. The stack verification is therefore considered acceptable for both Fan A and Fan B operations. The verification tests were performed at flows that were appreciably higher than the design conditions, and further elevated flow rates would be beyond the range of acceptable DV. Based on these stack verification test results, the three LAB filtered exhaust stacks meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the scale model test reports (Glissmeyer, Flaherty, and Piepel (2001), Glissmeyer and Geeting (2013)) may require additional tests and additional analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗