Search NASA⌕ Search

SEARCH · Search NASA

Results for “LAR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

TinyTPC: A Test Stand for LAr Doping

LArTPCs are widely used in neutrino experiments at the GeV scale. They measure the charge and light produced by interactions between charged particles and argon atoms. While charge is collected efficiently, light is not. TinyTPC is a small scale LArTPC with a pixelated readout for R&D with photosensitive dopants, which convert light into charge. TinyTPC studies the effects of adding photosensitive dopants and xenon to liquid argon to enhance charge signals of events in the MeV scale.

Rodriguez Thorne, Paloma↗

Calorimetric Identification of Composite Nuclei in LAr

In neutrino-nucleus interactions, Final State Interactions (FSI) can cause nucleons to scatter or form heavier composite particles like deuterons and tritons. Observing these particles would provide direct evidence of FSI and help improve interaction models, which is essential for precise neutrino energy reconstruction in future experiments like DUNE. Our Goal: Develop an analysis to detect particles heavier than protons in ICARUS data to better constrain FSI models.

McCright, Hannah [Maryland U., College Park]↗

Commissioning of the trigger system for the ICARUS T600 LAr-TPC detector in SBN Program

The ICARUS experiment at Fermilab is the far detector of the Short Baseline Neutrino Program (SBN), aimed at studing the neutrino oscillation to find a fourth type of neutrino, called sterile neutrino. A key component for this detector is the trigger system, which aims to identify and isolate the physical interactions from the background events. In this framework my internship program was dedicated to the development of trigger logic and trigger inhibit mechanism in order to select the genuine neutrino interaction and to guarantee a correct functioning of the readout system. These two steps, that represent a part of the commissioning of the trigger system, were implemented with LabVIEW Software. The obtained results are a fundamental step towards a succesful activation of the detector in the next few months.

43 PARTICLE ACCELERATORS↗

Uncertainty Propagation within Chained Models for Machine Learning Reconstruction of Neutrino-LAr Interactions

Sequential or chained models are increasingly prevalent in machine learning for scientific applications, due to their flexibility and ease of development. Chained models are particularly useful when a task is separable into distinct steps with a hierarchy of meaningful intermediate representations. In reliability-critical tasks, it is important to quantify the confidence of model inferences. However, chained models pose an additional challenge for uncertainty quantification, especially when input uncertainties need to be propagated. In such cases, a fully uncertainty-aware chain of models is required, where each step accepts a probability distribution over the input space, and produces a probability distribution over the output space. In this work, we present a case study for adapting a single model within an existing chain, designed for reconstruction within neutrino-Argon interactions, developed for neutrino oscillation experiments such as MicroBooNE, ICARUS, and the future DUNE experiment. We test the performance of an input uncertainty-enabled model against an uncertainty-blinded model using a method for generating synthetic noise. By comparing these two, we assess the increase in inference quality achieved by exposing models to upstream uncertainty estimates.

97 MATHEMATICS AND COMPUTING↗

Examination of simulated behavior of ND-LAr and TMS detectors using CAFAna for DUNE analysis framework

Simulations are run using the new DUNE CAFAna framework to generate pseudo-data modeling the interactions of neutrinos in the DUNE near detector at truth-level and detector-level. Truth-level analysis of neutrino kinematics reveals strong agreement with expected behavior, validating the kinematic portion of the simulation. Examination of the detector-level reconstructions of coordinates of interaction vertex appear consistent with an interaction density independent of detector position. Track lengths of particles resultant from neutrino interactions are aligned with varied particle identities, but are misaligned with prediction of uniform position density.

Fein, Jarrett [Fermilab]↗

Overview of Collaborative Research Between UNICAMP in Brazil and Fermilab in Cryogenics

The Long-Baseline Neutrino Facility (LBNF) situated at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, serves as the host for the Deep Underground Neutrino Experiment (DUNE), employing cryostats with nearly 70,000 metric tons of high purity liquid argon (LAr). The integrity of LAr quality is pivotal in determining the electron lifetime within DUNE, directly impacting its signal-to-noise ratio. Specifically, Far Detector 1 (FD-1) in cryostat 1 requires an electron lifetime over 3 ms within its 3.5 m drift, corresponding to less than 100 parts-per-trillion (ppt) Oxygen equivalent contamination. Far Detector 2 (FD-2) in cryostat 2 demands over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen equivalent contamination. Nitrogen (N2) absorption of LAr scintillation light, known as quenching, necessitates N2 contamination in LAr to remain below 1 ppm to minimize photon loss and enhance energy reconstruction. Studies indicate that at 1 ppm N2, approximately 20% of scintillation light is lost, highlighting the importance of minimizing N2 contamination. Brazil State University of Campinas's (UNICAMP) contribution to LBNF focuses on developing argon purification and regeneration for DUNE FD-1 and FD-2. To that effect, they constructed a test facility to perform studies on LAr purification at a smaller scale, the Purification Liquid Argon Cryostat (PuLArC) with approximately 90 liters of LAr. One of the filtration materials was considered and tested Li-FAU molecular sieve. Value engineering on argon purification media was conducted, leading to the identification of Li-FAU zeolite's ability to effectively capture N2 impurities during LAr circulation. Testing at UNICAMP's PuLArC facility demonstrated that 1 kg of Li-FAU is capable of reducing N2 contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours of circulation. In October 2023, testing at the Iceberg cryostat in Fermilab's Noble Liquid Test Facility (NLTF), with approximately 2,625 liters of LAr, confirmed the efficacy of 3 kg of Li-FAU in reducing N2 contamination from ~ 5 ppm of injected N2 down to less than 1 ppm over 96-hour cycles, showcasing its potential for larger-scale LAr cryostats. Further tests are planned to validate Li-FAU's use as a possible alternative to Molecular Sieve 4A in LBNF-DUNE and related liquid argon experiments. This contribution will describe how the research was performed and present the test setups and results in detail. This advancement not only has the potential to enhance DUNE's precision but also to elevate liquid argon experiments globally, showcasing the power of international scientific collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fun- damental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr- based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared

Gallego-Ros, Ana↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fundamental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr-based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared.

Gallego Ros, Ana↗

A risk-informed assessment tool to support review of license amendment requests for spent nuclear fuel dry cask storage systems

We report that while risk-informed safety evaluations are common methodologies used by the U.S. Nuclear Regulatory Commission (NRC), their application in the field of commercial spent nuclear fuel (SNF) dry storage has received limited attention. For instance, license amendment requests (LARs) for SNF dry cask storage systems (DCSSs) are evaluated according to U.S. NRC standard review plans (SRPs). However, risk-informed LAR review strategies could improve the understanding of critical system modifications, and lead to more predictable, efficient, and consistent LAR review processes. A methodology to develop a risk-informed LAR review tool is presented. Although focused on DCSSs, this methodology can be used to develop similar tools for a broad spectrum of safety-relevant systems. The end product (i.e., the tool) includes a tree diagram to help visualize the review risk significances assigned to a predefined set of system modifications and supporting rationale documentation. Instructions support correct tool application and provide the user with a path to incorporate currently unevaluated modifications in the tool structure. The demonstration of the methodology leads to the conclusion that risk-informed reviews of DCSS LARs are possible, although the tool precision could benefit from additional risk information. Further, the results indicate that many typical LARs involve low-risk or medium-risk modifications.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Noble Liquid Test Facility at Fermilab

The Noble Liquid Test Facility (NLTF) at Fermilab is a liquid argon detector R\&D facility open to the national and international HEP community. The facility consists of 4 permanent cryostats, ranging from 250L up to 3000L, open space for small open dewar testing, and an optical test stand facility capable of measuring the optical properties of materials and characterizing photon detectors. NLTF’s strongest advantage is its capability to provide ultra-pure LAr in a reliable manner. Its inline filters are capable of filtering all of the three biggest contaminants for standard LAr detectors, O$_2$ and H$_2$O down to $< 1$ppb and N$_2$ $< 1$ppm. This is critical for the users of the test stands as small levels of impurities can dramatically change the efficiency of LArTPCs for the collection of charge and light. The smallest cryostat is mainly used for material testing, a service provided to the international HEP community interested in understanding how the introduction of a specific material might affect the electron lifetime in LAr. The test stands can be equipped with a purity monitor, which allows measuring the electron lifetime in real time, as well as gas sampling and analyzing, and in the near future, local recirculation and filtering. The facility has hosted many successful R\&D projects, which have published their results in well-known journals and talks. A few examples of such projects are: NIR light production in LAr and GAr, the characterization of VUV metalenses, the testing of new filter media capable of filtering N$_2$ from LAr, high voltage studies and direct charge amplification in LAr, and various doping studies.

Blaszczyk, Flor María [Fermilab]↗

Modeling impurity concentrations in liquid argon detectors

Impurities in noble liquid detectors used for neutrino and dark matter experiments can significantly impact the quality of data. We present an experimentally verified model for describing the dynamics of impurity distributions in liquid argon (LAr) detectors. The model considers sources, sinks, and transport of impurities within and between the gas and liquid argon phases. Measurements of oxygen concentrations in a 20-L LAr multi-purpose test stand are compared to calculations made with this model to show that an accurate description of the concentrations under various operational conditions can be obtained. A result of this analysis is a determination of Henry’s coefficient for oxygen in LAr. Additionally, these calculations also show that some processes have small effects on the impurity dynamics and excluding them yields a solution as a sum of two exponential terms. This solution provides a simple way to extract Henry’s coefficient with negligible approximation error. It is applied to the data and the Henry’s coefficient for oxygen in LAr is obtained as 0.84 +0.09 -0.05 , consistent with literature results. Finally, based on the analysis of the data with the model, we further suggest that, for a large liquid argon detector, barriers to flow (“baffles”) installed in the gas phase to restrict flow can help reduce the ultimate impurity concentration in the LAr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of xenon doping in the scintillation light in a large liquid-argon TPC

The use of xenon-doped liquid argon (Xe-doped LAr) is a promising alternative for large-scale liquid argon Time Projection Chambers (LAr-TPC), since it mitigates the light suppression due to impurities and it also improves the photon-detection efficiency and uniformity with the distance. This study analyses the impact of using Xe-doped LAr in ProtoDUNE Dual-Phase, a 750 ton Dual-Phase LAr-TPC placed at CERN. ProtoDUNE Dual-Phase completed a Xe-doping data-taking campaign in summer 2020 by re-filling the detector with 230 tons of Xe-doped LAr contaminated with nitrogen, and performing dedicated nitrogen injections. The effects of the presence of Xe at 5.8 ppm in the scintillation light production and propagation are analysed in this paper, showing an increase of the collected photons, but a suppression of the light signal amplitude. A 60% increase of the light attenuation length is measured. The impact on the scintillation time profile is also studied. A model to fit the time profile is proposed and the time constants of the physics processes are obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the liquid argon scintillation pulse shape using differentiable simulation in the coherent CAPTAIN-Mills experiment

The coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and beyond Standard Model physics signatures. Two hundred eight-inch photomultiplier tubes instrument the seven-ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM’s light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with 𝒪⁡(1) parts per million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte Carlo simulation and detailed photomultiplier tube response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

Cherenkov detectors↗

Exploring the Nature of Neutrinos with the Deep Underground Neutrino Experiment (DUNE)

The Deep Underground Neutrino Experiment (DUNE) is a next-generation experimental program designed to study the behaviour of neutrino oscillation. DUNE will utilize a neutrino beam originating at Fermilab, near Chicago, and will leverage a detector at Fermilab (Near Detector) and a detector 1300 km away in South Dakota (Far Detector), south of Saskatchewan. In the first phase of DUNE, its Far Detector will comprise of two 10,000 ton (fiducial) liquid argon (LAr) time-projection chamber (TPC) modules – powerful tracking calorimeter detectors – placed nearly a mile underground. With this large, sensitive, underground detector, DUNE aims to collect a high statistics and pure sample of neutrinos at the Far Detector. This setup also offers the potential to study non-beam physical processes via e.g. neutrinos produced in the atmosphere, supernova neutrino bursts, and/or solar neutrinos, etc. A second phase will aim to add more detector mass and expand the program. The Near Detector will consist of a LAr TPC module as well: critical to constraining systematic uncertainties in the oscillation analysis. However, this LAr TPC will have a novel design using a pixel-based readout instead of the traditional wire-based readout. This and the segmentation of the LAr TPC into multiple units are crucial in mitigating the high multiplicity of neutrino interactions expected in any readout window given its proximity to the beam. The Near Detector will feature additional components and capability beyond the LAr TPC, allowing one to deeply characterize the neutrino flux. Due to the complexity of this experimental program, several smaller-scale prototype detectors have been operating to test, validate, and improve both the technical designs and software for processing and analyzing events. By operating in charged particle test beams or neutrino beams, several of the prototypes are also capable of producing valuable results. Canadian institutions are involved in the realization of the DUNE through efforts with both the Near and Far Detectors and prototypes. DUNE is anticipated to begin operating near the end of this decade/the beginning of the next. This talk will focus on the overall DUNE program, for example its ultimate plans, status, and the efforts with prototypes.

Howard, Bruce [York U., Canada; Fermilab]↗

Understanding neutrinos with accelerator beams and liquid argon time-projection chambers: ICARUS and DUNE

A global program of experiments has worked towards characterizing neutrino oscillation over the past few decades. However, important parameters remain to be measured, and mysteries remain to be elucidated. Current and upcoming experiments are targeting the open questions and probing the consistency of the neutrino oscillation paradigm. Likewise, the liquid argon (LAr) time-projection chamber (TPC) has emerged as a sensitive particle detection technology for neutrino experiments. A current generation of LAr TPC detectors are being used to study neutrinos while also gaining important experience in operating and analyzing with this technology. SBND, MicroBooNE, and ICARUS have collected or are collecting data from beams at Fermilab (near Chicago) to explore the possibility of a sterile neutrino and/or other beyond Standard Model (BSM) physics. SBND and ICARUS will be used to conduct a two-detector analysis as part of the Short Baseline Neutrino (SBN) Program. Additionally, these detectors are enabling important neutrino interaction studies necessary to prepare for the next generation of oscillation experiments. One such oscillation experiment that will come online over the next years is the Deep Underground Neutrino Experiment (DUNE), which will install multiple 10 kiloton LAr TPCs underground in South Dakota (south of Saskatchewan) to conduct oscillation measurements with neutrinos originating in a beamline at Fermilab. A detector complex will be installed at Fermilab as well, to study the beam before the expected flavour oscillations. This “near detector” will also employ a LAr TPC, with a segmented and pixel-based design, as well as other technologies to constrain uncertainties in the oscillation measurement by characterizing the beam and neutrino interactions. This talk will discuss the ICARUS and DUNE experiments, the LAr TPC detector technology, and the efforts to realize and leverage these experiments to better understand the properties of neutrinos.

Howard, Bruce L. [Fermilab]↗

Xenon doping of liquid argon in ProtoDUNE single phase

The Deep Underground Neutrino Experiment (DUNE) will be the next generation long-baseline neutrino experiment. The far detector is designed as a complex of four LAr-TPC (Liquid Argon Time Projection Chamber) modules with 17 kt of liquid argon each. The development and validation of the first far detector technology is pursued through ProtoDUNE Single Phase (ProtoDUNE-SP), a 770 t LAr-TPC at CERN Neutrino Platform. Crucial in DUNE is the photon detection system that will ensure the trigger of non-beam events — proton decay, supernova neutrino burst and BSM searches — and will improve the timing and calorimetry for neutrino beam events. Doping liquid argon with xenon is a known technique to shift the light emitted by argon (128 nm) to a longer wavelength (178 nm) to ease its detection. The largest xenon doping test ever performed in a LAr-TPC was carried out in ProtoDUNE-SP. From February to May 2020, a gradually increasing amount of xenon was injected to also compensate for the light loss due to air contamination. The response of such a large TPC has been studied using the ProtoDUNE-SP Photon Detection System (PDS) and a dedicated setup installed before the run. With the first it was possible to study the light collection efficiency with respect to the track position, while with the second it was possible to distinguish the xenon light (178 nm) from the LAr light (128 nm). The light shifting mechanism proved to be highly efficient even at small xenon concentrations (<20 ppm in mass) furthermore it allowed recovering the light quenched by pollutants. The light collection improved far from the detection plane, enhancing the photon detector response uniformity along the drift direction and confirming a longer Rayleigh scattering length for 178 nm photons, with respect to 128 nm ones. The charge collection by the TPC was monitored proving that xenon up to 20 ppm does not impact its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗