Search NASA⌕ Search

SEARCH · Search NASA

Results for “LASER SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Stratospheric composition measurements of earth and Titan using high-resolution tunable diode laser spectroscopy

Field and laboratory measurements of species of atmospheric interest made as part of the JPL diode laser spectroscopy program are presented. Stratospheric measurements of NO2, NO, CO2, and H2O made in November 1985 using the BLISS instrument are reported, together with recent laboratory measurements of spectral line parameters of HNO3 and HO2NO2. In addition, a novel diode laser instrument concept for the in situ sensing of Titan's atmosphere is described for the Saturn Orbiter/Titan Probe (SOTP) Cassini Mission.

Webster, Christopher R.↗

Oxygen Spectroscopy Laser Sounding Instrument for Remote Sensing of Atmospheric Pressure

We report on the progress of an Oxygen spectroscopy laser sounding instrument designed as a calibration channel for a carbon dioxide (CO2) laser sounding instrument. We have developed a pulsed, frequency-doubled, fiber laser transmitter for use in an oxygen instrument. The instrument concept uses the pressure broadening of spectroscopic lines of the diatomic oxygen A-band to deduce atmospheric pressure. There are many uses for this measurement but we are developing it primarily to make a measurement of the dry mixing ratio of CO2. The CO2 measurement can be affected by changes in atmospheric properties such as humidity, temperature and pressure. To remove these variances requires measuring a stable, well-mixed gas like Oxygen. We will report on the basic theory behind the instrument, measurements made at a test site at Goddard, review the current state of the instrument technologies and the necessary steps to bring them to space readiness, and review the current state of the instrument development.

Stephen Mark A.↗

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk↗

In-gas-jet laser spectroscopy with S 3 -LEB

The Super Separator Spectrometer-Low Energy Branch (S 3 -LEB) is a low-energy radioactive ion beam experiment under commissioning as part of the GANIL-SPIRAL2 facility. It will be used for the production and study of exotic nuclei by in-gas laser ionization and spectroscopy (IGLIS), decay spectroscopy, and mass spectrometry. Here, we report recent results from the off-line commissioning of S 3 -LEB, including first laser spectroscopy measurements in both the gas cell and the supersonic gas jet, the determination of the transport efficiency of laser ions from the gas cell through the RFQ chain, and time-of-flight measurements with the multi-reflection time-of-flight mass spectrometer PILGRIM. The measurements were performed using erbium, introduced by evaporation from a heated filament in the gas environment. The reported laser spectroscopy results include a characterization of the pressure broadening in the gas cell, proof-of-principle isotope shift measurements, and hyperfine-structure measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of silicon-carbon clusters by infrared laser spectroscopy. The nu 1 band of SiC4

The nu 1 fundamental vibration of linear SiC4 has been observed by infrared diode laser spectroscopy of a supersonic cluster beam. Twenty-four rovibrational transitions were measured in the spectral region of 2094.6 to 2097.1 cm-1, the rotational temperature was 10 K. A combined least-squares fit of these transitions with previously reported microwave data yielded the following molecular constants: nu 1 = 2095.45806(37) cm-1, B" = 0.051161131(52) cm-1, and B' = 0.0509157(96) cm-1. These results are compared to vibrational spectroscopy measurements of SiC4 trapped in a solid Ar matrix and to ab initio calculations.

NASA Discipline Exobiology↗

Laser spectroscopy of indium Rydberg atom bunches by electric field ionization

This work reports on the application of a novel electric field-ionization setup for high-resolution laser spectroscopy measurements on bunched fast atomic beams in a collinear geometry. In combination with multi-step resonant excitation to Rydberg states using pulsed lasers, the field ionization technique demonstrates increased sensitivity for isotope separation and measurement of atomic parameters over previous non-resonant laser ionization methods. The setup was tested at the Collinear Resonance Ionization Spectroscopy experiment at ISOLDE-CERN to perform high-resolution measurements of transitions in the indium atom from the 5s 2 5d 2 D 5/2 and 5s 2 5d 2 D 3/2 states to 5s 2 np 2 P and 5s 2 nf 2 F Rydberg states, up to a principal quantum number of n=72 . The extracted Rydberg level energies were used to re-evaluate the ionization potential of the indium atom to be 46,670.107(4)cm -1 . The nuclear magnetic dipole and nuclear electric quadrupole hyperfine structure constants and level isotope shifts of the 5s 2 5d 2 D 5/2 and 5s 2 5d 2 D 3/2 states were determined for 113,115 In. The results are compared to calculations using relativistic coupled-cluster theory. A good agreement is found with the ionization potential and isotope shifts, while disagreement of hyperfine structure constants indicates an increased importance of electron correlations in these excited atomic states. With the aim of further increasing the detection sensitivity for measurements on exotic isotopes, a systematic study of the field-ionization arrangement implemented in the work was performed at the same time and an improved design was simulated and is presented. The improved design offers increased background suppression independent of the distance from field ionization to ion detection.

74 ATOMIC AND MOLECULAR PHYSICS↗

Laser spectroscopy of metastable palladium at 340 and 363 nm

Here we report measurements of the isotope shift of the mass 104, 105, 106, 108, and 110 stable palladium isotopes for transitions from the metastable state $4d^9(^2D_{5/2})5s$, $^2[5/2]_3 → 4d^9(^2D_{5/2})5p, ^2[7/2]^o_4$ at 340 nm, and $4d^9(^2D_{5/2})5_s, ^2[5/2]_3 → 4d^9(^2D_{5/2})5p, ^2[3/2]^o_2$ at 363 nm. For 105 Pd , we determine the hyperfine structure of both transitions. The measurements were performed by saturation absorption spectroscopy in a custom-built hollow cathode lamp and will serve as a reference for collinear laser spectroscopy of short-lived neutron-rich palladium isotopes. We also report on the observation of a population inversion for the 363-nm transition under certain discharge conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Instantaneous Three-Dimensional Temperature Measurements via Ultrafast Laser Spectroscopy with Structured Light

Detonations and flames are characterized by three-dimensional (3D) temperature fields, yet state-of- the-art temperature measurement techniques yield information at a point or along a line. The goal of the research documented here was to combine ultrafast laser spectroscopy and structured illumination to deliver an unprecedented measurement capability—three-dimensional, instantaneous temperature measurements in a gas-phase volume. To achieve this objective, different parts of the proposed technique were developed and tested independently. Structured illumination was used to image particulate matter (soot) in a turbulent flame at multiple planes using a single laser pulse and a single camera. Emission spectroscopy with structured detection was demonstrated for emission- based measurements of explosives with enhance dimensionality. Finally, an instrument for multi- planar laser-based temperature measurement technique was developed. Structured illumination techniques will continue to be developed for multi-dimensional and multi-parameter measurements. These new measurement capabilities will be important for heat transfer and fluid dynamic research areas.

42 ENGINEERING↗

An experiment concept to measure stratospheric trace constituents by laser heterodyne spectroscopy

Laser heterodyne spectroscopy (LHS) techniques were used to measure radical gases from Spacelab. Major emphasis was placed on the measurement of ClO, ClOnO2, HO2, H2O2, N2O5, and HOCl in solar occultation with vertical resolution less than or equal to 2-km and vertical range from 1O to 70-km. Sensitivity analyses were performed on ClO and O3 to determine design criteria for the LHS instrument. Results indicate that O3 and ClO vertical profiles can be measured with an accuracy more than or equal to 95% and more than or equal to 80%, respectively, over the total profile.

Allario, F.↗

Stable isotope laser spectroscopy

Recent advances in semiconductor laser technology have produced a reliable lightweight device ideally suited for a spacecraft high resolution molecular spectrometer. Lead-salt tunable diode lasers (TDL) emit in several spectral modes, each with a very narrow linewidth of -0.0003/cm. This spectral resolution is much narrower than typical Doppler broadened molecular linewidths in the mid-IR range. Thus it is possible to detect individual rotational lines within the vibrational band and measure their intensity, which can be used to determine gas concentration. The narrow spectral lines of any impurity gas tend to lie between the narrow lines of the gas of interest. This represents a major advantage over the accepted gas chromatograph mass spectrometer (GCMS) technique for measuring gas concentrations and isotope ratios. The careful and extensive gas purification procedures required to remove impurities for reliable GCMS measurements will not be required for an IR laser gas analysis. The infrared laser gas analysis technique is being developed to measure stable isotopic ratios of gases such as CO2, CH4, N2O, and NH3. This will eventually lead to development of instruments capable of in situ istopic measurements on planets such as Mars. The carbon (C-12, C-13) isotope ratio is indicative of the type of carbon fixation mechanisms (e.g., photosynthesis, respiration) in operation on a planet, while the nitrogen (N-14, N-15) isotope ratio can probably be used to date nitrogen-bearing Martian samples. The absorbance ratio of two adjacent lines of CO2 in the 2300/cm (4.3 micron) region of the spectrum was measured. The precision of the measurement is presently better than 1 percent and significant improvement is anticipated as rapid sweep-integration techniques and computer controlled data acquistion capabilities are incorporated.

Becker, J. F.↗

Infrared laser spectroscopy of jet-cooled carbon clusters - The bending dynamics of linear C9

We report improved measurements for the nu6 antisymmetric stretch fundamental and observation of the (nu6 + nu15) - nu15 and (nu6 + 2nu15) - 2nu15 hot bands of the linear C9 carbon cluster by direct absorption diode laser spectroscopy of a supersonic carbon cluster beam. Analysis of these bands characterizes C9 as a semirigid molecule with a bending potential similar to that of C5 and further evidences the alternation in degree of rigidity of linear carbon clusters with the g-u symmetry of the HOMO.

Van Orden, A.↗

Measurement of pressure-broadening and lineshift coefficients at 77 and 296 K of methane lines in the 727 nm band using intracavity laser spectroscopy

Pressure-broadening coefficients and pressure-induced lineshifts of several rotational-vibrational lines have been measured in the 727 nm absorption band of methane at temperatures of 77 and 296 K, using nitrogen, hydrogen, and helium as the foreign-gas collision partners. A technique involving intracavity laser spectroscopy is used to record the methane spectra. Average values of the broadening coefficients (/cm/atm) at 77 K are: 0.199, 0.139, 0.055, and 0.29 for collision partners N2, H2, He, and CH4, respectively. Typical average values of the pressure-induced lineshifts (/cm/atm) at 77 K and for the range of foreign gas pressures between 10 and 200 torr are -0.052 for N2, -0.063 for H2, and +0.031 for He. All the values obtained at 296 K are considerably different from the corresponding values at 77 K. This represents the first report of pressure-broadening and shifting coefficients for the methane transitions in a region where the delta nu(sub C-H) = 5 band occurs.

Singh, Kuldip↗

Structural trends in atomic nuclei from laser spectroscopy of tin

Tin is the chemical element with the largest number of stable isotopes. Its complete proton shell, comparable with the closed electron shells in the chemically inert noble gases, is not a mere precursor to extended stability; since the protons carry the nuclear charge, their spatial arrangement also drives the nuclear electromagnetism. We report high-precision measurements of the electromagnetic moments and isomeric differences in charge radii between the lowest 1/2 + , 3/2 + , and 11/2 - states in 117–131 Sn, obtained by collinear laser spectroscopy. Supported by state-of-the-art atomic-structure calculations, the data accurately show a considerable attenuation of the quadrupole moments in the closed-shell tin isotopes relative to those of cadmium, with two protons less. Linear and quadratic mass-dependent trends are observed. While microscopic density functional theory explains the global behaviour of the measured quantities, interpretation of the local patterns demands higher-fidelity modelling.

74 ATOMIC AND MOLECULAR PHYSICS↗

Methane overtone absorption by intracavity laser spectroscopy

Interpretation of planetary methane (CH4) visible-near IR spectra, used to develop models of planetary atmospheres, has been hampered by a lack of suitable laboratory spectroscopic data. The particular CH4 spectral bands are due to intrinsically weak, high overtone-combination transitions too complex for classical spectroscopic analysis. The traditional multipass cell approach to measuring spectra of weakly absorbing species is insufficiently sensitive to yield reliable results for some of the weakest CH4 absorption features and is difficult to apply at the temperatures of the planetary environments. A time modulated form of intracavity laser spectroscopy (ILS), has been shown to provide effective absorption pathlengths of 100 to 200 km with sample cells less than 1 m long. The optical physics governing this technique and the experimental parameters important for obtaining reliable, quantitative results are now well understood. Quantitative data for CH4 absorption obtained by ILS have been reported recently. Illustrative ILS data for CH4 absorption in the 619.7 nm and 681.9 nm bands are presented. New ILS facilities at UM-St. Louis will be used to measure CH4 absorption in the 700 to 1000 nm region under conditions appropriate to the planetary atmospheres.

Obrien, James J.↗

Laser-spectroscopy testbed for impurity monitoring in liquid metal-cooled fast reactors

A significant challenge in sodium-cooled fast reactors is controlling impurities, in particular oxygen impurities, within the sodium coolant, as they can accelerate corrosion and indicate leaks. Optical methods offer the potential to rapidly detect small concentrations of both gaseous and metal impurities that accelerate corrosion, plug coolant channels, and lead to increased activation of isotopes in the coolant. We present the design and performance of an apparatus designed to enable the application of multiple optical analytical techniques, such as laser-induced breakdown spectroscopy, to detect elemental impurities in the sodium melt with high sensitivity. Here, we experimentally demonstrate the detection of characteristic sodium and oxygen spectral lines in liquid sodium, which sets the stage for the optimization of its analytical sensitivity. A robust sensor of this type integrated with the sodium cooling loop has the potential to significantly improve the safety and operational efficiency of generation IV nuclear reactors.

47 OTHER INSTRUMENTATION↗

Monitoring The Atmosphere By Diode-Laser Spectroscopy

Report describes state of art of tunable-diode-laser second-harmonic spectroscopy applied to measurements of concentrations of trace constituents of atmosphere. Combination of temperature, composition, and drive-current tuning, wavelengths of tunable diode lasers varied over infrared range of 3 to 30 micrometer, containing spectral lines of many molecules of interest in atmospheric research.

Loewenstein, Max↗