Search NASA⌕ Search

SEARCH · Search NASA

Results for “LC resonator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

25 records · Page 2

Comments on Lambeck and Coleman - 'The earth's shape and gravity field: A report of progress from 1958 to 1982'

The accuracy and validation of global gravity models based on satellite data are discussed, responding to the statistical analysis of Lambeck and Coleman (1983) (LC). Included are an evaluation of the LC error spectra, a summary of independent-observation calibrations of the error estimates of the Goddard Earth Models (GEM) 9 and L2 (Lerch et al., 1977, 1979, 1982, 1983, and 1985), a comparison of GEM-L2 with GRIM-3B (Reigber et al., 1983), a comparison of recent models with LAGEOS laser ranging, and a summary of resonant-orbit model tests. It is concluded that the accuracy of GEMs 9, 10, and L2 is much higher than claimed by LC, that the GEMs are in good agreement with independent observations and with GRIM-3B, and that the GEM calibrations were adequate. In a reply by LC, a number of specific questions regarding the error estimates are addressed, and it is pointed out that the intermodel discrepancies of the greatest geophysical interest are those in the higher-order coefficients, not discussed in the present comment. It is argued that the differences among the geoid heights of even the most recent models are large enough to call for considerable improvements.

Lerch, F. J.↗

Steady-state and dynamic characteristics of a 20-kHz spacecraft power system - Control of harmonic resonance

A detailed computer simulation was used to illustrate the steady-state and dynamic operating characteristics of a 20-kHz resonant spacecraft power system. The simulated system consists of a parallel-connected set of DC-inductor resonant inverters (drivers), a 440-V cable, a node transformer, a 220-V cable, and a transformer-rectifier-filter (TRF) AC-to-DC receiver load. Also included in the system are a 1-kW 0.8-pf RL load and a double-LC filter connected at the receiving end of the 20-kHz AC system. The detailed computer simulation was used to illustrate the normal steady-state operating characteristics and the dynamic system performance following, for example, TRF startup. It is shown that without any filtering the given system exhibits harmonic resonances due to an interaction between the switching of the source and/or load converters and the AC system. However, the double-LC filter at the receiving-end of the AC system and harmonic traps connected in series with each of the drivers significantly reduce the harmonic distortion of the 20-kHz bus voltage. Significant additional improvement in the waveform quality can be achieved by including a double-LC filter with each driver.

Wasynczuk, O.↗

Wireless Capacitive Pressure Sensor With Directional RF Chip Antenna for High Temperature Environments

This paper presents the design, fabrication and characterization of a wireless capacitive pressure sensor with directional RF chip antenna that is envisioned for the health monitoring of aircraft engines operating in harsh environments. The sensing system is characterized from room temperature (25 C) to 300 C for a pressure range from 0 to 100 psi. The wireless pressure system consists of a Clapp-type oscillator design with a capacitive MEMS pressure sensor located in the LC-tank circuit of the oscillator. Therefore, as the pressure of the aircraft engine changes, so does the output resonant frequency of the sensing system. A chip antenna is integrated to transmit the system output to a receive antenna 10 m away.The design frequency of the wireless pressure sensor is 127 MHz and a 2 increase in resonant frequency over the temperature range of 25 to 300 C from 0 to 100 psi is observed. The phase noise is less than minus 30 dBcHz at the 1 kHz offset and decreases to less than minus 80 dBcHz at 10 kHz over the entire temperature range. The RF radiation patterns for two cuts of the wireless system have been measured and show that the system is highly directional and the MEMS pressure sensor is extremely linear from 0 to 100 psi.

Pressure sensor↗

Demonstration of a Packaged Capacitive Pressure Sensor System Suitable for Jet Turbofan Engine Health Monitoring

In this paper, the development and characterization of a packaged pressure sensor system suitable for jet engine health monitoring is demonstrated. The sensing system operates from 97 to 117 MHz over a pressure range from 0 to 350 psi and a temperature range from 25 to 500 deg. The sensing system consists of a Clapp-type oscillator that is fabricated on an alumina substrate and is comprised of a Cree SiC MESFET, MIM capacitors, a wire-wound inductor, chip resistors and a SiCN capacitive pressure sensor. The pressure sensor is located in the LC tank circuit of the oscillator so that a change in pressure causes a change in capacitance, thus changing the resonant frequency of the sensing system. The chip resistors, wire-wound inductors and MIM capacitors have all been characterized at temperature and operational frequency, and perform with less than 5% variance in electrical performance. The measured capacitive pressure sensing system agrees very well with simulated results. The packaged pressure sensing system is specifically designed to measure the pressure on a jet turbofan engine. The packaged system can be installed by way of borescope plug adaptor fitted to a borescope port exposed to the gas path of a turbofan engine.

Harsh environment↗

Nuclear Magnetic Resonance Used to Quantify the Effect of Pyrolysis Conditions on the Oxidative Stability of Silicon Oxycarbide Ceramics

This work was undertaken in support of the Low Cost Ceramic Composite Virtual Company, (LC^3), whose members include Northrop Grumman Corporation, AlliedSignal Inc., and Allison Advanced Development Company. LC^3 is a cost-shared effort funded by the Advanced Research Projects Agency (ARPA) and the LC^3 participants to develop a low-cost fabrication methodology for manufacturing ceramic matrix composite structural components. The program, which is being administered by the U.S. Air Force Wright Laboratory Materials Directorate, is focused on demonstrating a ceramic matrix composite turbine seal for a regional aircraft engine. This part is to be fabricated by resin transfer molding of a siloxane polymer into a fiber preform that will be transformed into a ceramic by pyrolytic conversion.

Source record↗

Novel High-Voltage, High-Power Piezoelectric Transformer Developed and Demonstrated for Space Communications Applications

Improvements in individual piezoelectric transformer (PT) performance and the combination of these PTs in a unique modular topology under a Phase I contract with the NASA Glenn Research Center have enabled for the first time the simultaneous achievement of both high voltage and high power at much higher levels than previously obtained with any PT. Feasibility was demonstrated by a prototype transformer (called a Tap-Soner), which is shown in the preceding photograph as part of a direct-current to direct-current (dc-dc) converter having two outputs rated at 1.5 kV/5 W and 4.5 kV/20 W. The power density of 3.5 W/cm3 is significantly lower than for magnetic transformers with the same voltage and power output. This development, which is being done under a Small Business Innovation Research (SBIR) contract by Face Electronics, LC (Norfolk, VA), is based on improvements in the materials and design of Face's basic patented Transoner-T3 PT, shown in the left in the following figure. The T3 PT is most simply described as a resonant multilayer transducer where electrical energy at the input section is efficiently mechanically coupled to the output section, which then vibrates in a fundamental longitudinal mode to generate a high gain in voltage. The piezoelectric material used is a modified lead-zirconium-titanate-based ceramic. One of the significant improvements in PT design was the incorporation of a symmetrical double input layer, shown on the right in the following figure, which eliminated the lossy bending vibration modes characteristic of a single input layer. The performance of the improved PT was optimized to 1.5 kV/5 W. The next step was devising a way to combine the individual PTs in a modular circuit topology needed to achieve the desired high voltage and power output. Since the optimum performance of the individual PT occurs at resonance, the most efficient operation of the modular transformer was achieved by using a separate drive circuit for each PT. The output section consists of a separate output rectifier for each PT connected in series.

Carazo, Alfredo V.↗

Coronal Polarimetry: Determining the Magnetic Origins of Coronal Mass Ejections

Synopsis: The mechanism for the release of stored magnetic energy in solar eruptions remains a major unsolved problem of Heliophysics. Choosing between triggers requires knowledge of pre-eruptive magnetic fields (B). Although linear polarization in visible/infrared (VIR) coronal emission lines reveals intriguing clues about coronal mass ejection (CME) precursor topology, small telescope apertures limit current capability for measuring vector field. Current coronal observations are insufficient to diagnose 3D coronal magnetic fields in CME precursors. Coronal cavities are the ideal candidates for CME precursor studies. BLOS in cavities is a direct measure of stored magnetic free energy, and the presence and location of topological X-points (reconnection locations) and O-points (circulation of B about axis) distinguish predictions of the flux rope-torus-instability and sheared-arcade-breakout CME models. - Finding: Coronal cavities are ubiquitous throughout the solar cycle, erupt as CMEs, and have coronal polarimetric signatures that distinguish between model predictions. - Recommendation: Coronal cavities should be targeted in a comprehensive multiwavelength study of CME precursors & associated eruption-driving mechanisms. Large ground-based VIR telescopes can measure both coronal magnetic field topology and strength through a combination of the saturated Hanle and BLOS -sensitive Zeeman effects. - Finding: The 4m Daniel K. Inouye Solar Telescope (DKIST) and proposed 1.5m Coronal Solar Magnetism Observatory Large Coronagraph (COSMO-LC) make a major leap forward in VIR coronal sensitivity, enabling measurement of vector B. - Recommendation: A dedicated coronal synoptic telescope with a large field-of-view (i.e., COSMO-LC) is needed to identify the dominant CME driving mechanisms, by measuring coronal magnetic fields from precursor state into eruption. In the UV, a new opportunity has arisen to make use of the strong H I Lyman-α coronal line, which obtains a measurement of B that is independent of the Zeeman effect. - Finding: Small-telescope spectropolarimetric capability in the unsaturated Hanle regime provides an independent and complementary coronal magnetic diagnostic to large ground-based telescope measurements. - Recommendation: The proposed 12-cm Coronal Lyman-α Resonance Observatory (CLARO) spectropolarimetric coronagraph demonstrates a path forward for space-based observations of the coronal magnetic field that should be incorporated into future missions away from the Sun-Earth line (e.g., COMPLETE).

magnetic energy↗