Search NASA⌕ Search

SEARCH · Search NASA

Results for “LCLS-II”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Materials Science of the Interstitial Doping Process

Particle accelerators are an increasingly important tool for frontier science. Growing initial and operating costs are a significant barrier for upgrades and for new machines. While everything matters, the major cost contributor is the SRF cavities and their ancillary facilities (e.g., cryoplant). Accordingly, the accelerator science community devotes much R&D effort to improving their energy efficiency (increased Q o ) and gradient (E acc ). While improved gradient is at the forefront for certain machines (ILC), improved quality factor has broader impact, benefitting all SRF applications. An important opportunity for accelerator science and technology to move forward arose in the course of building the LCLS-II, the second generation Linac Coherent Light Source at SLAC. At more or less the same time, researchers at Fermilab discovered that introducing a small amount of nitrogen to the niobium surface could improve the mid-range quality factor as much as three-fold. A firm resolution of how nitrogen confers its benefit attracts much current research interest. The key elements of the “nitrogen doping” process were vacuum bake at 800 °C, brief exposure to mTorr of nitrogen at several hundred degrees followed by electropolish (EP) to remove several microns from the surface to eliminate unwanted nitrides: While the process as a whole was novel, the comprising unit operations are familiar to the accelerator community. It was judged reasonable to adopt it as a cost-reduction technology for LCLS-II. Researchers carried out a program of varying process parameters and measuring performance in single-cell cavities, leading to a consensus stable protocol for the project. The transition to vendor fabrication and multiple niobium sources has presented unforeseen challenges of performance variation evidently not connected to anything that could be incorporated in a purchase specification. Moving beyond the high temperature N-doping process above, researchers reported a simplified process consisting entirely of tens of hours anneal in a N atmosphere at low temperatures (~120°C – 160°C) after 800 °C UHV bake. These processes typically yield a few-nm doped layer while the high temperature process yields at least a few to many micron doped layer. Even more recently, oxygen has been used to dope instead of nitrogen which leaves a few-µm O-alloyed layer upon vacuum annealing for 300 °C for ~3 hours. The investigation of these materials is just beginning, but the process simplification they may offer is surely attractive. The very low quantity of material that appears to be significant in the “infusion” process indicates the need for very careful control of gas species available for diffusion into the surface during low temperature treatment, both for process control and research to characterize the underlying dynamics. Oxygen alloying offers the further opportunity to utilize the decomposition of the surface native oxide as the dopant source. It is necessary to understand and (thus) manage this process. We have been supported by the Department of Energy Offices of High Energy Physics and Nuclear Physics to pursue this goal.

36 MATERIALS SCIENCE↗

Numerical Analysis of High-Order Modes in SRF Resonators for Particle Accelerators

Over the past decades, superconducting technology has rapidly evolved towards high accelerating gradients and low surface resistance, making it possible to operate particle accelerators with high average beam currents and large duty factors. However, RF losses due to coherent excitation of the HOM become the limiting factor for these regimes. Unlike the cavity operating mode, which is tuned separately, the HOM parameters can significantly vary from one cavity to another due to finite mechanical tolerances during the manufacturing process. Thus, it is of utmost importance to know the HOM parameter spread in advance in order to predict unexpected cryogenic losses, overheating of beam line components and maintain stable beam dynamics. In this paper, we present a method for generating cavity geometry with an arbitrary spread of mechanical imperfections and numerically evaluating HOM statistics. Knowing the spread of HOM parameters, we calculated the probability of resonant HOM losses in SRF accelerating cavities used in CW beam current machines such as the PIP-II and LCLS-II linacs, as well as for the SRF crab-cavity for the ILC project. Finally, we present experimental results of HOM spectra measurements in hundreds of 1.3 GHz cavities installed in LCLS-II cryomodules. Studying the effects of HOM excitation results in specifications of the SRF cavity and cryomodule and can significantly impact the efficiency and reliability of the machine operation.

Lunin, Andrei [Fermilab] (ORCID:0000000290096792)↗

LLRF System Analysis for the Fermilab PIP-II Superconducting LINAC

PIP-II is a superconducting linac that is in the initial acceleration chain for the Fermilab accelerator complex. The RF system consists of a warm front-end with an RFQ and buncher cavities along with 25 superconducting cryo-modules comprised of cavities with five different acceleration \(β\). The LLRF system for the linac has to provide field and resonance control for a total of 125 RF cavities. Various components of the LLRF system have been tested with and without beam at the PIP-II test stands. The LLRF system design is derived from the LCLS-II project with its self-excited loop architecture used in the majority of the cryo-modules. The PIP-II beam loading at 2 mA is much higher than the LCLS-II linac. The control system architecture is analyzed and evaluated for the operational limits of feedback gains and their ability to meet the project regulation requirements for cavity field amplitude and phase regulation.

Varghese, P. [Fermilab] (ORCID:0009000925131983)↗

The chemRIXS Instrument for Solution-Phase Resonant Inelastic X-ray Scattering at the Linac Coherent Light Source

The chemRIXS instrument at the Linac Coherent Light Source (LCLS) offers new opportunities for studying solution-phase systems with time-resolved soft X-ray spectroscopic methods such as resonant inelastic X-ray scattering (RIXS) using the recently commissioned high-repetition-rate LCLS-II X-ray free electron laser. The orders-of-magnitude X-ray flux improvement provided by the superconducting accelerator, combined with corresponding advances in the optical laser system and the liquid jet recirculation system, enables studies on dilute systems with high signal-to-noise compared to what was possible with the LCLS-I copper accelerator. These capabilities open up time-resolved X-ray absorption spectroscopy and RIXS to entirely new classes of samples, as well as enabling the development of new soft X-ray spectroscopic methods on liquid samples. An overview of the beamline components and the first LCLS-II commissioning results are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photon-rejection power of the Light Dark Matter eXperiment in an 8 GeV beam

The Light Dark Matter eXperiment (LDMX) is an electron-beam fixed-target experiment designed to achieve comprehensive model independent sensitivity to dark matter particles in the sub-GeV mass region. An upgrade to the LCLS-II accelerator will increase the beam energy available to LDMX from 4 to 8 GeV. Using detailed GEANT4-based simulations, we investigate the effect of the increased beam energy on the capabilities to separate signal and background, and demonstrate that the veto methodology developed for 4 GeV successfully rejects photon-induced backgrounds for at least 2 × 10 14 electrons on target at 8 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A hybrid neural architecture: Online attosecond x-ray characterization

The emergence of high-repetition-rate x-ray free-electron lasers (XFELs), such as SLAC’s LCLS-II, serves as our canonical example for autonomous controls that necessitate high-throughput diagnostics paired with streaming computational pipelines capable of single-shot analysis with extremely low latency. We present the deterministic characterization with an integrated parallelizable hybrid resolver architecture, a hybrid machine learning framework designed for fast, accurate analysis of XFEL diagnostics using angular streaking-based sinogram images. This architecture integrates convolutional neural networks and bidirectional long short-term memory models to denoise input, identify x-ray sub-spike features, and extract sub-spike relative delays with sub-30 attosecond temporal resolution. Deployed on low-latency hardware, it achieves over 10 kHz throughput with 168.3 μs inference latency, indicating scalability to 14 kHz with field-programmable gate array integration. By transforming regression tasks into classification problems and leveraging optimized error encoding, we achieve high precision with low-latency performance that is critical for real-time streaming event selection and experimental control feedback signals. This represents a key development in real-time control pipelines for next-generation autonomous science, generally, and high repetition-rate x-ray experiments in particular.

Accelerator Physics (physics.acc-ph)↗

Integration of a new Cryogenic Liquefier into the IB-1 Cryogenic Test Facility

The increase over the last years of the testing activities related to quantum systems, SRF cavities for the PIP-II and the LCLS-II projects, as well as superconducting magnets for the HL-LHC project and Fusion research activities, has required the addition of a new Helium cryogenic plant into the existing IB-1 Industrial Cryogenic Test Facility. The new cryogenic plant is composed of a cryogenic liquefier (Cold Box) able to provide up to 340 L/h, a 4 kL Dewar and two Mycom ® compressors providing up to 120 g/s. AL-AT (Air Liquide Advanced Technologies) has taken part of this project by designing and manufacturing the cryogenic liquefier. This new cryogenic plant is connected through a cryogenic distribution system to a 10 kL Dewar, which is part of the existing cryogenic test facility, itself composed of another Cold Box and a Sullair ® compressor. The new cryogenic plant has two main operating modes: one allows to transfer liquid helium at 1.7 bar between the two Dewars, the other allows to transfer supercritical Helium at 2 bar or more between the new Cold Box and the 10 kL Dewar. The entire industrial cryogenic facility is handled by a common Inventory Control System, composed of three control valves, and 9 tanks giving a total buffer volume of more than 1000 m3. This paper presents the technical features of the new Helium cryogenic plant, as well as the main results of the liquefier commissioning phase and details of the helium transfer between the two Dewars, making the connection between the cryogenic plants at the IB-1 Industrial Cryogenic Test Facility.

43 PARTICLE ACCELERATORS↗

Design, tuning, and blackbox optimization of laser systems

Chirped pulse amplification (CPA) and subsequent nonlinear optical (NLO) systems constitute the backbone of myriad advancements in semiconductor manufacturing, communications, biology, defense, and beyond. Accurately and efficiently modeling CPA+NLO-based laser systems is challenging because of the complex coupled processes and diverse simulation frameworks. Our modular start-to-end model unlocks the potential for exciting new optimization and inverse design approaches reliant on data-driven machine learning methods, providing a means to create tailored CPA+NLO systems unattainable with current models. To demonstrate this new, to our knowledge, technical capability, we present a study on the LCLS-II photo-injector laser, representative of a high-power and spectro-temporally non-trivial CPA+NLO system.

47 OTHER INSTRUMENTATION↗

Twinac: initiation of a community-driven accelerator digital twin framework

We present the initiation of a community-driven framework for the integration of accelerator digital twins into control systems: Twinac. Few facilities have fully integrated accelerator digital twins like at Cornell’s CHESS. Many facilities have active research to employ surrogate models to aid in operational decisions like at Argonne’s ALS, MSU’s FRIB, SLAC’s LCLS-II, and Fermilab’s FAST/IOTA, PIP-II, and main complex. To lower the barrier to entry for all accelerator facilities to build and benefit from a digital twin of their own accelerators, we propose the following software framework. Twinac will provide the capability to compose one’s own digital twin using reusable components engineered at other facilities. With this model in place, Twinac will also support tools for (1) predictive maintenance systems; (2) discovery of correlated but uncontrolled environmental factors, like seasonal temperature variations causing performance changes on power supplies, magnets, etc.; and (3) prototyping and updating sophisticated optimization and controls algorithms. The Twinac framework will enable sharing and simplified deployment of modeled components and control algorithms at all facilities. With an inter-facility team to build and support the Twinac framework, it will be easy to publish and try out the latest advancements at one’s own facility.

Miceli, Tia [Fermilab]↗

Xopt and Badger: a machine learning ecosystem for real-time accelerator control and optimization

Machine learning (ML)-based black-box optimization algorithms have demonstrated significant improvements in accelerator optimization speed, often by orders of magnitude. However, deploying these algorithms in real-time facility control remains challenging due to the specialized expertise and infrastructure required. To bridge this gap, we introduce the Xopt ecosystem, a versatile suite of tools designed to make advanced ML-based optimization accessible to the broader accelerator community. This ecosystem includes Xopt, a modular Python framework that facilitates the integration of ML-based optimization algorithms with arbitrary control problems, and Badger, a graphical user interface built on top of Xopt, which enables seamless deployment of ML algorithms in real-time control systems. The Xopt ecosystem has been successfully applied towards solving challenging real-time control problems at leading international accelerator facilities, including SLAC, LBNL, Argonne, Fermilab, BNL, DESY, and ESRF, demonstrating its effectiveness in real-world optimization tasks. In this presentation, we provide an overview of Xopt’s capabilities and illustrate its impact through case studies from SLAC accelerator facilities including LCLS, LCLS-II, and FACET-II.

Roussel, Ryan [SLAC]↗

Results from extended range SRF cavity tuner tests for LCLS-II-HE

The LCLS-II HE superconducting linac can produce multi-energy beams by supporting multiple undulator lines simultaneously. This could be achieved by using the cavity SRF tuner in the off-frequency detune mode. This off-frequency operation method was tested in 8 cryomodules at Fermilab at 2 K. In all the tests the tuners successfully achieved a frequency shift of -565±80 kHz from the 1.3 GHz value. This study discusses the cavity frequency during each stage of assembly from the cryomodule string to when they are finally tested at 2 K. Monitoring the cavity frequency from this initial stage contributed in reaching this large frequency shift. The specific procedures of tuner setting during assembly will be presented.

43 PARTICLE ACCELERATORS↗

SIMS CHARACTERIZATION OF NITROGEN DOPING OF LCLS-II-HE PRODUCTION CAVITIES

The thermal diffusion of nitrogen into the surface of niobium has been shown to yield superior low-loss SRF performance. An effective solution was identified and promptly employed in the production of cryomodules for LCLS-II. With added experience and R&D, a modified process was chosen for use in the upgrade for LCLS-II-HE. Largely motivated by this circumstance, supporting research has significantly refined the technique for making calibrated secondary ion mass spectrometry (SIMS) measurements of the N concentration depth profiles produced by production processes. Standardized reference samples were included with four HE production cavities in their N-doping furnace runs. We report the calibrated dynamic SIMS depth profiles of N, C, and O for these samples, together with the cryogenic acceptance test performance of the associated cavities. Interpretation and comparison with similar samples acquired in other furnaces highlights the importance of intentional process quality control of furnace conditions.

Reece, Charles↗

Integration of a new Cryogenic Liquefier into the IB-1 Cryogenic Test Facility

aThe increase over the last years of the testing activities related to superconducting quantum materials, SRF cavities for the PIP-II and the LCLS-II projects, as well as superconducting magnets for the HL-LHC project and Fusion research activities, has required the addition of a new Helium cryogenic plant into the existing IB-1 Industrial Cryogenic Test Facility. The new cryogenic plant is composed of a cryogenic liquefier (Cold Box) able to provide up to 340 L/h, a 4kL Dewar and two Mycom compressors providing up to 120 g/s. AL-AT (Air Liquide Advanced Technologies) has taken part of this project by designing and manufacturing the cryogenic liquefier. This new cryogenic plant is connected through a cryogenic distribution system to a 10 kL Dewar, which is part of the existing cryogenic test facility, itself composed of another Cold Box and a Sullair compressor. The new cryogenic plant has two main operating modes: one allows to transfer liquid helium at 1.7 bar between the two Dewars, the other allows to transfer supercritical Helium at 2 bar or more between the new Cold Box and the 10 kL Dewar. The entire industrial cryogenic facility is handled by a common Inventory Control System, composed of three regulatory valves, and 9 tanks giving a total buffer volume of more than 1000 m3. This paper presents the technical features of the new Helium cryogenic plant, as well as the main results of the liquefier commissioning phase and details of the helium transfer between the two dewars, making the connection between the cryogenic plants at the IB-1 Industrial Cryogenic Test Facility.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Extensible High Energy Density Modeling Tool for Extreme Regimes

The overreaching goal of the project is to develop a simulation capability to model an entire High Energy Density (HED) target heated by an X-ray Free Electron Laser (XFEL) beam including the surrounding material with a focus on target material associated with subsequent shots. Our primary objective is to study target fratricide problems, where radiation/debris from the current shot degrade the target for subsequent shots. This work will have a large impact on research being conducted at HED facilities where the quality of data is directly related to the effective repetition rate of the driver, which is often limited by target fratricide problems. This project focuses on a stream of closely spaced droplet targets that are appropriate for new very high repetition rate sources such as the ~1 MHz LCLS-II upgraded XFEL. The capability of the PISALE (Pacific Island Structured-AMR with ALE) code is extended to model this class of problems. We summarize the capability and improvements made to the HED branch of the PISALE code. We discuss our simulations of target fratricide for small (5 micron) hydrogen droplets heated by an XFEL beam at SLAC. We also compare simulations of the initial dynamics of larger (50 micron) water droplets, heated by the same XFEL beam, with experimental data. We briefly discuss training, dissemination, and related activities associated with this project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experience of developing highly reliable Tuner components (piezo actuators and cold stepper motor actuators) for SRF Linac

The resonance control team at FNAL has led the design of the LCLS-II SRF Linac SRF cavity tuner subsystem. The Linac is expected to operate for over 30 years, and the longevity of the tuner is crucial to the overall reliability of the Linac. When the tuner's design was started, there were no active actuators (stepper and piezo) that could meet the longevity requirements of the Linac. The FNAL resonance control team, in collaboration with industrial partners (Phytron and PI), has developed actuators that have been shown to withstand a cryogenic and insulating vacuum environment for over 100 years in accelerated lifetime tests. Details of actuators design and longevity testing will be presented. Now, practically all (small and large) SRF systems that are under construction around the world are using actuators developed at FNAL. A review of possible actuators improvement will be presented.

Pischalnikov, Yuriy [Fermilab]↗

Cavity Preparation and Assembly: Challenges and Future R&D Directions

This presentation described the state of the art in cavity string assembly for the LCLS-II, HE, and PIP-II projects, as well as cavity performance statistics. The presentation also described the knowledge gap, opportunities for improvement, and future R&D recommendations.

Wu, Genfa [Fermilab]↗

Cavity Preparation and Assembly: Challenges and Future R&D Directions

This presentation described the state of the art in cavity string assembly for the LCLS-II, HE, and PIP-II projects, as well as cavity performance statistics. The presentation also described the knowledge gap, opportunities for improvement, and future R&D recommendations.

Wu, Genfa [Fermilab]↗

LDMX -- The Light Dark Matter eXperiment

LDMX, The Light Dark Matter eXperiment, is a missing momentum search for hidden sector dark matter in the MeV to GeV range. It will be located at SLAC in End Station A, and will employ an 8 GeV electron beam parasitically derived from the SLAC LCLS-II accelerator. LDMX promises to expand the experimental sensitivity of these searches by between one and two orders of magnitude depending on the model. It also has sensitivity in visible ALP searches as well as providing unique data on electron-nucleon interactions.

Appert, Stephen [Caltech]↗