Characterization of InGaAs Linear Array for Applications to Remote Sensing

An Indium Gallium Arsenide linear photodiode array in the 1.1-2.5 micron spectral range was characterized. The array has 1024x1 pixels with a 25 micron pitch and was manufactured by Sensors Unlimited, Inc. Characterization and analysis of the electrical and optical properties of a camera system were carried out at room temperature to obtain detector performance parameters. The signal and noise were measured while the array was uniformly illuminated at varying exposure levels. A photon transfer curve was generated by plotting noise as a function of average signal to obtain the camera gain constant. The spectral responsivity was also measured, and the quantum efficiency, read noise and full-well capacity were determined. This paper describes the characterization procedure, analyzes the experimental results, and discusses the applications of the InGaAs linear array to future earth and planetary remote sensing mission.

Garcia, Christopher S.↗

Multispectral linear array focal plane

A description is provided of a sensor chip array for a unified multispectral focal plane for the Multispectral Linear Array (MLA) instrument. The involved concept of sensing multispectral earth resources imagery through the use of spectral filters deposited directly on a single row of silicon charge-coupled device (CCD) chips has been considered for a number of years. A simplified focal plane was designed after a number of experiments. Technology considerations regarding the design of the multispectral focal plane are discussed. Experimental data are presented which show that the arising problems have been or can be solved.

Hall, J. A.↗

A proof of the Woodward-Lawson sampling method for a finite linear array

An extension of the continuous aperture Woodward-Lawson sampling theorem has been developed for a finite linear array of equidistant identical elements with arbitrary excitations. It is shown that by sampling the array factor at a finite number of specified points in the far field, the exact array factor over all space can be efficiently reconstructed in closed form. The specified sample points lie in real space and hence are measurable provided that the interelement spacing is greater than approximately one half of a wavelength. This paper provides insight as to why the length parameter used in the sampling formulas for discrete arrays is larger than the physical span of the lattice points in contrast with the continuous aperture case where the length parameter is precisely the physical aperture length.

Somers, Gary A.↗

The pointable multispectral linear array system and the large format camera for early 1980 shuttle payloads

Design options are described for the multispectral linear arrays which will provide data and facilities beyond those obtained by LANDSAT 1, 2, 3, and D (the thematic mapper) are considered. The features, uses, and risks of a 10M fine resolution pointable imager, a 15M/30M dual resolution pointable imager, a 30M selectable spectral resolution pointing imager, a 30M electronically pointable multi-temporal sampler, and a 40M/80M mixed resolution imager are described. A large format camera scheduled for 1981 shuttle launch which can obtain high spatial ground resolution (approximately 10M), a relative position accuracy of plus or minus 14M, and a relative heightening accuracy, by virtue of stereographic coverage, of between 7 and 28M depending on the base-to-height ratio used. A potential problem of the system is that it will orbit in the shuttle.

Slater, P. N.↗

Multispectral linear array (MLA) focal plane mechanical and thermal design

The mechanical and thermal design of an integrated focal plane subsystem of a Multispectral Linear Array (MLA) instrument is discussed in terms of focal-plane alignment, thermoelastic performance, and thermal requirements. The modular construction and thermal control of the focal plane array are discussed.

Mitchell, A. S.↗

On resolving 2M - 1 narrow-band signals with an M sensor uniform linear array

Length 2M real signal vectors are used to address the problem of determining the maximum number of narrow-band signals whose parameters can be estimated with a linear array of M equally spaced sensors. It is shown that 2M of these real vectors are linearly independent with probability one, and, thus in the presence of additive white noise, the parameters of 2M - 1 signals can be estimated. An algorithm for determining directions and amplitudes is presented.

Williams, Douglas B.↗

Honeywell multispectral linear array (MLA) instrument design A system overview

In support of NASA's Experimental Land Observing System, a simple, reliable and relatively inexpensive multispectral linear array (MLA) instrument concept has been developed. The design satisfies requirements for multichannel radiometry and wide field imaging. A reflective off-axis anastigmat telescope is mounted in a highly strength-to-weight efficient truss structure, coupled to a solid beamsplitter assembly. Attention is given to the optical design of the MLA instrument, the telescope structure, the detector arrays, detector cooling, on-orbit calibration, signal processing electronics, the spacecraft interfaces, the modulation transfer function, the signal-to-noise ratio, radiometric accuracy, and spatial registration.

Eyring, D.↗

Maximum theoretical angular accuracy of planar and linear arrays of sensors

The maximum theoretical accuracy in the angular location of a radiating object that can be obtained by using a planar or linear array is studied. The elements are assumed to have identical radiation patterns and the complex voltages observed at their ports are assumed to be subject to phase measurement errors, having normal probability density. An optimum scheme for the statistical extraction of the parameters defining the direction is established noting that the presence of thermal noise does not affect the structure of the estimator. Comparisons with the conventional multiple interferometric techniques are made.

Borgiotti, G. V.↗

Optical Scanner for Linear Arrays

Optical scanner instantaneously reads contiguous lines forming scene or target in object plane. Reading active or passive and scans, continuous or discrete. Scans essentially linear with scan angle and symmetric about axial ray. Nominal focal error, resulting from curvature of scan, well within Rayleigh limit. Scanner specifically designed to be fully compatible with general requirements of linear arrays.

Finkel, M. W.↗

The linear array multi-band selection device role in remote-sensing instrument design

A figure-of-merit parameter for the scientific utility of multispectral linear array (MLA) instruments for civil remote sensing is presented. The number of spectral band-pair choices available to the user of a given MLA instrument is proposed as a useful measure of the flexibility and overall utility of that particular instrument design. The multiband selection device capability is analyzed mathematically, and a basis for a cost-benefit comparison of alternative multispectral instrument designs is provided.

Speaker, E. E.↗

Slow-scan operation of long linear CCD arrays

Linear CCD arrays used singly or in optically butted assemblies permit practical implementation of long line array systems with 6000 or more picture elements per line with readout rates in excess of 5 MHz. Display and tape recording of slow scan imagery with over 1000 picture elements per line also presents unique challenges. This paper discusses performance results and the operation of 1728-element CCD arrays for generation of high resolution slow scan imagery and some approaches for recording and display of the imagery. The implication of dark current and its control are discussed.

Vicars-Harris, M.↗

Multispectral linear array multiband selection device

An apparatus for detecting multiple spectral bands, individually or concurrently, using linear detector arrays is described. The system employs a beamsplitter to divide the optical source into two or more optical beams which are directed at the linear detector arrays. Filter trays are positioned in the focal planes of the optical beams so that the beams pass through the filter trays prior to impinging upon the detector arrays. Multiple filters are placed on the filter trays. Linear actuators positioned adjacent the filter trays translate the trays across the focal planes of the optical beams so that individual filters are positioned in the path of beams such that those frequencies of the beams that fall within the spectral ranges of the individual bandpass filter through which it passes may be detected by the detector arrays for further examination and analysis.

Richard, H. L.↗

Multispectral Linear Array (MLA) science and technology program

A Goddard Space Flight Center program of science studies and technology development to provide the basis for future earth observation sensors employing multispectral linear array (MLA) technology is described. Establishment of MLA performance parameters and performance modeling make up the primary science activities. Critical technologies being developed include: short-wave infrared (SWIR) detector arrays, visible/and near infrared detector arrays, and passive cryogenic coolers. Supporting activities include: test and field instrument development, focal plane research and assessment laboratory, system simulation laboratory, calibration sources and techniques, optics, and thermal infrared arrays.

Barnes, W. L.↗

Studies of optical and biological properties of terrestrial land cover using multispectral linear array technology

A series of experiments to study the optical and biological properties of terrestrial land cover are planned for late 1987 using a six-channel imaging spectroradiometer based on newly developed multispectral linear array (MLA) detector technology. Data from selected portions of the Sahel and rain forests of Africa and South America will be used to delineate biomass classes and estimate spherical albedos. A spatial resolution of 15 meters in the four visible-near IR channels and 30 meters in two shortwave IR channels, including a 'new' channel centered at 1.24 micrometers when combined with a spectral width of 20 nm for all channels, will be used to investigate possible improvements in land cover classification. Technology demonstrations include a test of data compression on data quality, the first spaceborne utilization of short wave infrared Schottky barrier Pd2Si detector arrays, and the use of close-butted, multi-array modules with attached spectral filters.

Barnes, W. L.↗

Near-infrared linear array spectrometer for space applications

A 128-element InSb linear detector array read out with a field effect transistor (FET) multiplexing scheme has been developed at the Jet Propulsion Laboratory. State-of-the-art NEP, uniform response, on-detector charge integration, and very low focal plane heat load compared to that of discrete detector arrays allows this type of array to open new possibilities for spaceborne near-infrared imaging spectrometers. Large number of cooled detector elements are feasible with the new technology, making it practical to design sensitive spectrometers even for spinning spacecraft where simultaneous wavelength coverage is necessary to avoid confusion of spatial with spectral variations.

Apt, J.↗