Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOADS, LANDING - IMPACT, LAND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Design of a 3.4-MW wind turbine with integrated plasma actuator-based load control

Historically, cost reduction in wind energy has been accomplished by increasing hub heights and rotor diameters to capture more energy per turbine. The growth in rotor and turbine costs with increasing turbine sizes is also driven by the additional structure that must be added to withstand unsteady aerodynamic loads caused by turbulence, gusts, wind shear, misaligned yaw, upwind wakes, and the tower shadow. In this paper, we present a holistic design solution to integrate active load control using a controllable Gurney flap based on plasma actuators. We illustrate the design solution for a land-based 3.4-MW wind turbine rotor. Comparisons to a baseline reference 3.4-MW wind turbine show significant load reduction (15–18% DEL reduction for flap-wise blade root moments), rotor mass reduction (5–8%), and LCOE reduction (1.16–3.11%). To achieve these results, a comprehensive sequential-iterative design procedure is introduced to integrate the controllable Gurney flap into the turbine design and to drive the design solution toward the best LCOE reduction solution. Results are presented for mapping fatigue load reductions into cost reductions. In addition, an evaluation of active load control extended from Region-III to also include Region-II showed a further 34% reduction in DEL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Groundwater flowpath characteristics drive variability in per- and polyfluoroalkyl substances (PFAS) loading across a stream-wetland system

Groundwater dependent ecosystems in areas with industrial and military land use are at risk of direct exposure to a wide range of contaminants, including PFAS chemicals. Glaciated terrain often has mixed high and low permeability sediments coupled with groundwater flow-through lake features. These hydrogeologic attributes create highly complex ‘source to seep’ dynamics that make spatiotemporal contaminant transport patterns difficult to predict. We investigated one such system in detail using a suite of heat-tracing and chemical methods. Numerous (n=57) preferential groundwater discharge zones (vertical flux rates ranging 0.2 to 3.2 m/d) were identified across the upper Quashnet River stream-wetland system in Mashpee, MA, USA, adjacent to an Air Force Base with several known PFAS source areas. Surface-water and groundwater samples were collected and analyzed (n=145) for precursors and terminal PFAS compounds between March and September 2022. Samples were collected at identified seeps along the Quashnet River (n=59), from wells upgradient from the stream-wetland system (n= 44), from contributing flow-through kettle lakes (n=8), and at multiple locations along the Quashnet River (n=34). Samples from seeps and wells had measured PFAS concentrations ranging from non-detect to approximate 3,500 ng/L (mean= 1,650 ng/L), and a range of deuterium excess values (3.2 to 15.9 per mil) indicative of varying degrees of groundwater-lake interaction prior to emergence at the discharge zones. Groundwater-lake interaction along flowpaths that sourced the sampled seeps was farther supported by significant correlations (p < 0.01) between deuterium excess and %PFAS precursors, and between %PFAS precursors and multiple terminal PFAS compounds (e.g., PFPeS, PFBS, PFHxS). However, some sampled seeps contributing groundwater to the stream-wetland system had much higher total PFAS concentrations (>1000 ng/L) than the upgradient kettle lakes, despite showing lake (evaporative) isotopic signatures, indicating the potential for groundwater flowpath convergence at wetland discharge zones and the influence of lakebed PFAS precursor reactions. PFAS compounds and water isotopic composition at sampled multilevel groundwater wells, rivers, lakes, and seeps suggest that a complex mixture of source groundwater and flowpath characteristics are responsible for diverse observed PFAS mixtures at preferential discharge zones across the stream-wetland system. Further, total PFAS loading patterns to the Quashnet River via groundwater discharge remained remarkably similar from winter to summer to fall conditions, despite a regional dry period in late summer 2022 with the upper river channel completely drying. This work addresses gaps in the existing PFAS literature by demonstrating the importance of subsurface fate and transport on PFAS compound concentrations in controlling contaminant mass loading in preferential groundwater discharge zones and presents a transferrable field toolkit for efficient characterization of spatially preferential PFAS transport dynamics.

Contaminant transport↗

Appliance level battery-based energy storage

A powered building system that includes an electric power distribution system configured to distribute electrical power to a plurality of receptacles; one or more load sources; and one or more battery systems associated with: a respective receptacle of the plurality of receptacles and a respective load source of the one or more load sources.

Griffith, Saul Thomas↗

Groundwater Inflows to the Columbia River Along the Hanford Reach and Associated Nitrate Concentrations

Healthy river ecosystems require the interaction of many physical and biological processes to maintain their status. One physical process supporting biogeochemical cycling is hydrologic exchange (i.e., hydrologic exchange flows, HEFs) between relatively fast-flowing channel waters and slower-flowing surface and subsurface waters (lateral and vertical). Land uses adjacent to rivers have the potential to alter the water quality of off-channel surface and subsurface waters, and HEFs therefore have the potential to deliver solutes associated with river-adjacent land uses to rivers. HEFs can be nonpoint, diffuse sources of pollution, making the ultimate pollution source difficult to identify, especially in large rivers. Here, we seek to identify HEFs in the Columbia River near Richland, WA by looking for anomalies in temperature and electrical conductivity (EC) along the bed of the river in February, June, July, August, and November 2018. These are ultimately the “ends” of HEFs as they are locations of subsurface inflow to the river. We found these anomalies to be a combination of warmer or colder and higher (but not lower) EC than river water. We identified a majority of warm anomalies in February and July 2018, and majority cold anomalies in June, August, and November 2018. High-EC anomalies were found mostly in February, August, and November. Combined, we observe a shift from warm, high EC anomalies dominating in February to equivalent EC, warm anomalies in June, to equivalent EC, cool anomalies dominating July. In August, we also measured dissolved nitrate ($NO^-_3$) in-situ to determine whether anomalies were associated with increased $NO^-_3$ loading to the river, especially along the eastern shoreline, which is dominated by agricultural land use. Inflows along the eastern shoreline have greater concentrations of nitrate than river water (up to 10 mg $N–NO^-_3$/L). This research demonstrates that HEFs are temporally and spatially dynamic transferring heat and solutes to rivers.

54 ENVIRONMENTAL SCIENCES↗

Structuring Nutrient Yields throughout Mississippi/Atchafalaya River Basin Using Machine Learning Approaches

To minimize the eutrophication pressure along the Gulf of Mexico or reduce the size of the hypoxic zone in the Gulf of Mexico, it is important to understand the underlying temporal and spatial variations and correlations in excess nutrient loads, which are strongly associated with the formation of hypoxia. This study’s objective was to reveal and visualize structures in high-dimensional datasets of nutrient yield distributions throughout the Mississippi/Atchafalaya River Basin (MARB). For this purpose, the annual mean nutrient concentrations were collected from thirty-three US Geological Survey (USGS) water stations scattered in the upper and lower MARB from 1996 to 2020. Eight surface water quality indicators were selected to make comparisons among water stations along the MARB over the past two decades. Principal component analysis (PCA) was used to comprehensively evaluate the nutrient yields across thirty-three USGS monitoring stations and identify the major contributing nutrient loads. The results showed that all samples could be analyzed using two main components, which accounted for 81.6% of the total variance. The PCA results showed that yields of orthophosphate (OP), silica (SI), nitrate–nitrites (NO 3 -NO 2 ), and total suspended sediment (TSS) are major contributors to nutrient yields. It also showed that land-planted crops, density of population, domestic and industrial discharges, and precipitation are fundamental causes of excess nutrient loads in MARB. These factors are of great significance for the excess nutrient load management and pollution control of the Mississippi River. It was found that the average nutrient yields were stable within the sub-MARB area, but the large nitrogen yields in the upper MARB and the large phosphorus yields in the lower MARB were of great concern. t-distributed stochastic neighbor embedding (t-SNE) revealed interesting nonlinear and local structures in nutrient yield distributions. Clustering analysis (CA) showed the detailed development of similarities in the nutrient yield distribution. Moreover, PCA, t-SNE, and CA showed consistent clustering results. This study demonstrated that the integration of dimension reduction techniques, PCA, and t-SNE with CA techniques in machine learning are effective tools for the visualization of the structures of the correlations in high-dimensional datasets of nutrient yields and provide a comprehensive understanding of the correlations in the distributions of nutrient loads across the MARB.

54 ENVIRONMENTAL SCIENCES↗

Arbuscular mycorrhizal fungal response to fire and urbanization in the Great Smoky Mountains National Park

Wildfires are increasing in frequency and intensity as drier and warmer climates increase plant detrital fuel loads. At the same time, increases in urbanization position 9% of fire-prone land within the United States at the wildland–urban interface. While rarely studied, the compounded effects of urbanization and wildfires may have unknown synergistically negative effects on ecosystems. Previous studies at the wildland–urban interface often focus on aboveground plant communities, but belowground ecosystems may also be affected by this double disturbance. In particular, it is unclear how much fire and urbanization independently or interactively affect nutritional symbioses such as those between arbuscular mycorrhizal (AM) fungi and the majority of terrestrial plants. In November 2016, extreme drought conditions and long-term fire suppression combined to create a wildfire within the Great Smoky Mountains National Park and the neighboring exurban city of Gatlinburg, TN. To understand how the double disturbance of urbanization and fire affected AM fungal communities, we collected fine roots from the 5 dominant understory species in September 2018 at each of 18 sites spanning 3 burn severities in both exurban and natural sites. Despite large variation in burn severity, plant species identity had the largest influence on AM fungi. AM fungal colonization, richness, and composition all varied most among plant species. Fire and urbanization did influence some AM fungal metrics; colonization was lower in burned sites and composition was more variable among exurban locations. There were no interactions among burn severity and urbanization on AM fungi. Our results point to the large influence of plant species identity structuring this obligate nutritional symbiosis regardless of disturbance regime. Therefore, the majority of AM fungal taxa may be buffered from fire-induced ecosystem changes if plant community composition largely remains intact, plant species life history traits allow for AM fungal persistence after fire disturbance, and/or nearby undisturbed habitat can act as an inoculum source for recolonization following fires. Thus, it is critical to maintain natural, undisturbed habitats interspersed within the wildland–urban interface.

59 BASIC BIOLOGICAL SCIENCES↗

Techno-economic feasibility of borehole thermal energy storage system connected to geothermal heat pumps for seasonal heating load of two buildings in Fairbanks, Alaska

Borehole thermal energy storage (BTES) is an effective solution for managing imbalanced heating and cooling loads in cold regions. This study evaluated the long-term feasibility of a BTES system in the Fairbanks area, Alaska, through building energy modeling, resource characterization, and numerical modeling. The system was designed to store waste heat from a nearby coal power plant during summer and provide thermal energy during winter to geothermal heat pumps supplying heating loads in two buildings. Heating load profiles were modeled for the buildings using EnergyPlus, and the results indicated the annual heating load was 5.6 times greater than the cooling load. 40 borehole heat exchangers were pre-designed approximately 100 m away from the two buildings in terms of land availability and regulatorily optimized depth. The 20-year performance of the designed BTES system under two operational scenarios—one with a 5-year preheating period and one without—was numerically modeled using subsurface temperature and properties characterized through the literature review and thermal response tests. Both scenarios demonstrated that the BTES has the capacity to fully cover the heating loads in the two buildings throughout the 20-year lifetime. Production temperatures at central wells were 33 % higher on average than at outer wells in both scenarios. The 5-year preheating period increased subsurface and extraction temperatures, and correspondingly annual average and total thermal energy production was higher for 8 years than in the scenario without the preheating period. These results highlight the long-term reliability and sustainability of the BTES system in meeting heating demands over its lifetime, with the preheating period offering potential performance improvements. Implementing the BTES system in cold regions with high heating demand, such as Fairbanks, Alaska, could provide a long-term, sustainable energy solution for managing imbalanced heating and cooling loads.

15 GEOTHERMAL ENERGY↗

Ground heat exchanger design tool with rowwise placement of boreholes

Simulation-based design tools have been used since the late 1980s for designing ground heat exchangers (GHE) used with ground source heat pump (GSHP) systems. The ground heat exchanger simulations used in these tools rely on thermal response functions known as g-functions. Because of the significant computational burden in computing g-functions for even a single configuration, the design tools have relied on libraries of pre-computed g-functions. These g-functions were available for standard configuration shapes, such as lines, rectangles, open rectangles, L-shapes, and U-shapes. Standard shapes are often sub-optimal. For any building on a site, the available land may preclude use of a standard shape. For large GSHP systems with significantly imbalanced annual heat rejection and extraction loads, large rectangular fields may experience significant heat build-up (or heat draw-down) in the interior of the field. This paper describes a new ground heat exchanger design tool capable of automatically selecting and sizing both standard and irregular configurations. The focus of this paper is a method for creating, selecting and sizing irregular configurations where the available land area and "no-go" zones are described as irregular polygons.

Spitler, Jeffery↗

Agro-IBIS/THMB Modeled Yield, Nitrogen Loss, and Profitability Maps for the Raccoon River Basin, Iowa, USA

This data was used to assess the potential for improving water quality in this watershed when integrating miscanthus, a bioenergy perennial grass, on to areas of low profit under current corn-soybean management and areas of high nitrogen leaching under both current and future climate conditions. This dataset includes all observations (yield, streamflow, nitrogen loads) and model simulation data used from Dr. Kelsie Ferin’s (former PhD student with Dr. Andy VanLoocke, ISU Dept. of Agronomy) dissertation and publication in Global Change Biology – Bioenergy (DOI: 10.1111/gcbb.13078). Modeled output included in this dataset includes corn, soybean, and miscanthus yields, nitrogen leaching rates, net mineralization rates, land use cover fractions with and without the inclusion of miscanthus, profitability maps, additional soil property maps, and simulated streamflow and nitrogen loads near the outlet of the Raccoon River Basin (Van Meter, Iowa) for both historical and future climate conditions. This dataset includes a mixture of netCDF, .tiff, .csv, and .xlsx files. See README.pdf for more information.

Ferin, Kelsie↗

One-pot ethanol production under optimized pretreatment conditions using agave bagasse at high solids loading with low-cost biocompatible protic ionic liquid

Agave bagasse (AG) is a potential bioenergy feedstock due to its high biomass productivity, even in semiarid lands. In particular, ionic liquid (IL) pretreatment using aprotic ILs (AILs) has greatly reduced AG recalcitrance towards downstream processing by lowering lignin content and achieving high sugar yields. However, AIL's low biocompatibility towards enzymes and bacteria combined with the high initial cost has limited further development of this technology. In a wash-free one-pot (OP) ethanol conversion process, the evaluation of AG pretreatment with a biocompatible low-cost protic IL (PIL), 2-hydroxyethylammonium acetate ([2-HEA][OAc]) was achieved, where PIL pretreatment was followed by enzymatic saccharification, then ethanol fermentation in a single vessel. The pretreatment conditions were optimized using a central composite design to enable high sugar conversion at low PIL content. Under optimized pretreatment conditions (160 °C, 60% IL loading and 1.5 h), a yield of 132 kg of ethanol per Ton of untreated biomass was estimated using high solids loading (30% solids loading) under a PIL-OP scheme. High lignin removal (>50%), a decreased cellulose crystallinity, and high glucan conversion (>85%) were achieved with PIL-pretreated AG comparable to yields obtained in an AIL-AG pretreated sample using 1-ethyl-3-methyl-imidazolium acetate ([C 2 C 1 Im][OAc]). Here, these results using [2-HEA][OAc] demonstrate the potential of AG in an OP scheme with improved total ethanol yields paving the way towards a more feasible IL-based biorefinery.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determining the Minimum Phase‐to‐Phase Gap Distance for Unconventional Transmission Lines Using Numerical Method

With the increasing demand for power transmission, compact, high surge impedance loading (HSIL) high-voltage transmission lines have emerged as a viable solution due to their reduced land acquisition costs and higher power delivery capability. The compactness of a transmission line depends on effective insulation coordination, particularly in determining the phase-to-phase clearance, which is governed by the critical flashover voltage under switching and lightning overvoltage conditions. Traditional methods for phase-to-phase clearance rely on empirical formulas derived from experimental data, which are convenient for conventional high-voltage lines. However, unconventional HSIL lines require a faster and more adaptable evaluation method, as they involve optimized conductor positioning to reduce right-of-way requirements while enhancing natural power loadability. This study presents a simplified numerical approach to determine the minimum phase-to-phase gap, utilizing arc propagation viability curves, and offers an efficient alternative to conventional empirical methods. The proposed method was successfully applied to a 500 kV conventional line as well as 500 and 735 kV unconventional line designs, demonstrating its capability in accurately assessing insulation requirements. Results reveal that the method can support reduced gap clearances while still maintaining reliability, thereby validating its usefulness in optimizing compact transmission line configurations.

Arafat, Easir [The University of Texas at Dallas, ↗

Simulate Wind Loading on RUTE SunTracker: Cooperative Research and Development (Final Report)

RUTE produces and delivers efficient, sustainable structural foundation systems for the wind and solar industries, instrumental in the effort to lower the cost of clean electricity and reduce CO2. RUTE's SunTracker is a high-clearance agrivoltaic solar array. The system uses raised cables, providing support with less materials and cost. These cables can provide tracking for increased energy generation and greater revenue, allowing the land beneath to be used for other means simultaneously. RUTE provided data files that NREL will use to perform computational fluid dynamics (CFD) simulations to characterize and predict wind loading on the 6x6 RUTE SunTracker photovoltaic (PV) array. Varying both the panel orientations and wind speeds provides information on how the array can manage a variety of weather conditions. These results, in turn, inform RUTE's design and construction of these arrays.

14 SOLAR ENERGY↗

One-to-one aeroservoelastic validation of operational loads and performance of a 2.8 MW wind turbine model in OpenFAST

Abstract. This article presents a validation study of the popular aeroservoelastic code suite OpenFAST leveraging weeks of measurements obtained during normal operation of a 2.8 MW land-based wind turbine. Measured wind conditions were used to generate one-to-one turbulent flow fields (i.e., comparing simulation to measurement in 10 min increments, or bins) through unconstrained and constrained assimilation methods using the kinematic turbulence generators TurbSim and PyConTurb. A total of 253 bins of 10 min of normal turbine operation were selected for analysis, and a statistical comparison in terms of performance and loads is presented. We show that successful validation of the model was not strongly dependent on the type of inflow assimilation method used for mean quantities of interest, which had median modeling errors per wind-speed interval generally within 5 %–10 % of the measurement. The type of inflow assimilation method did have a larger effect on the fatigue predictions for blade-root flapwise and tower-base fore–aft quantities, which surprisingly saw larger errors from the assumed higher-fidelity assimilation methods. Avenues for further work are discussed and include possible improvements to the aerodynamic, structural, and controller modeling that may offer insight on the origin of the up to ∼ 40 % median overprediction of fatigue for these quantities.

17 WIND ENERGY↗

An analysis of Potential Benefits of Adding Diurnal Thermal Storage in Geothermal Heat Pump Systems

Geothermal heat pumps (GHP) are highly efficient for space heating and cooling, utilizing the subsurface of the ground as seasonal energy storage through borehole heat exchangers (i.e., heat stored in summer is used to provide heating in winter, and cold stored in winter is used to provide cooling in summer). On the other hand, diurnal thermal energy storage can actively be charged and discharged for load shifting. Conventional thermal energy storage uses tanks filled with thermal storage media (such as phase change materials) and heat exchangers. It occupies building floor space or land areas outside the building, which may not be available especially in residential buildings. This paper will introduce a novel configuration that can utilize existing GHP system for both diurnal and seasonal thermal storage. This system can actively charge the ground on daily basis by injecting heat or cold in borehole heat exchangers. A simulation model was created for the novel configuration. Computer simulations were conducted using the model for the new GHP system serving a typical single-family house in three U.S. cities representing hot, warm, and cold climates. Based on simulation results, the potential benefits of load shifting and downsize of the expensive ground heat exchangers used by the GHP system were assessed.

Anees, Fady [ORNL]↗

Global net climate effects of anthropogenic reactive nitrogen

Anthropogenic activities have substantially enhanced the loadings of reactive nitrogen (Nr) in the Earth system since pre-industrial times, contributing to widespread eutrophication and air pollution. Increased Nr can also influence global climate through a variety of effects on atmospheric and land processes but the cumulative net climate effect is yet to be unravelled. Here we show that anthropogenic Nr causes a net negative direct radiative forcing of –0.34 [–0.20, –0.50] W m –2 in the year 2019 relative to the year 1850. This net cooling effect is the result of increased aerosol loading, reduced methane lifetime and increased terrestrial carbon sequestration associated with increases in anthropogenic Nr, which are not offset by the warming effects of enhanced atmospheric nitrous oxide and ozone. Future predictions using three representative scenarios show that this cooling effect may be weakened primarily as a result of reduced aerosol loading and increased lifetime of methane, whereas in particular N 2 O-induced warming will probably continue to increase under all scenarios. Our results indicate that future reductions in anthropogenic Nr to achieve environmental protection goals need to be accompanied by enhanced efforts to reduce anthropogenic greenhouse gas emissions to achieve climate change mitigation in line with the Paris Agreement.

54 ENVIRONMENTAL SCIENCES↗

Miscanthus: An Environmental Choice for Marginal Lands

Miscanthus x giganteus, or Giant Miscanthus, is a tall, perennial grass originally from Asia. It is considered a sterile hybrid that has been bred to not produce viable seeds. Instead, rhizomes are planted to establish the crop. Here, the rhizome is an underground modified stem mass that puts out shoots and roots supporting new growth each year. This perennial crop takes two to three years to reach maturity, but established stands can reach upwards of 12 ft. tall with a very thick canopy (Pyter, 2007). Miscanthus has shown potential for high dry matter yields compared to other biomass crops, which could in turn lead to more efficient land use especially when applied to a bioenergy and bioproduct supply chain. In one study, switchgrass (Panicum virgatum) yielded 10.3 Mg/ha of biomass on average, while miscanthus yielded 22.4 Mg/ha (Heaton et al., 2004). Additionally, miscanthus production has been associated with many environmental benefits, including benefits to water quality, nutrient load removal, soil stabilization, and soil health (Bhardwaj et al., 2011; Hussain et al., 2019). Many of the possible practical and environmental benefits that are associated with miscanthus production may be attractive to stakeholders who are interested in alternative land use options, particularly in areas considered to be marginal in productivity.

54 ENVIRONMENTAL SCIENCES↗

An efficient approach to explore the solution space of a wind turbine rotor design process

This study proposes a novel approach to explore the solution space of a wind turbine rotor design process. The goal is to offer to blade designers the possibility to select an optimal rotor for given market conditions, assessing trade-offs and alternatives in a matter of minutes. The design process consists of sequential aerodynamic-structural optimizations, where the two loops are linked via a blade-loading parameter that can be varied by the user. A design study is performed starting from the IEA Wind Task 37 land-based reference wind turbine. The solution space is characterized for rotor diameters in the range of 130–160 m, rated generator power values in the range of 3.0–6.0 MW, and tip-speed ratios in the range of 7.5–12.5. Results are discussed highlighting optimal design decisions and trade-offs.

17 WIND ENERGY↗

DC Fast Charging Infrastructure for Electrified Road Trips

To assess DC fast charging station network required for electrified road trips by 2030 in California, a new charging infrastructure simulation tool/model, EVI-Pro (Electric Vehicle Infrastructure Projection) RoadTrip, has been developed. In contrast to the existing EVI-Pro model that is primarily for short-distance travels, EVI-Pro RoadTrip is exclusively focused on road trips (long-distance travels, 100 or miles per day per vehicle). Also, the charging paradigm or strategy is different. EVI-Pro RoadTrip is built upon waypoint charging, in which vehicles are forced to stop to charge or replenish the on-board batteries, along the routes between origins and destinations. On the other hand, EVI-Pro is based on destination charging, in which charging is conducted when vehicles are parked in destinations (e.g., work, home). EVI-Pro RoadTrip takes coordinate-level origin and destination data for road trips (intra-state as well as domestic or international out-of-state) and estimates energy consumption and charging needs along the routes between origins and destinations on a minute-by-minute resolution. Based on charging demands for electrified road trips across the state, the optimal locations of charging stations are determined accounting for preferred land use types (e.g., commercial areas) and station service area (e.g., 5 or less miles). Based on station-by-station charging load profiles, the required number of plugs/connectors is estimated for each station and entire state. By comparing hosting capacity of the electric grid (circuit-level) and the charging load output from EVI-Pro RoadTrip, capacity deficit is also evaluated.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗