Search NASA⌕ Search

SEARCH · Search NASA

Results for “LPM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Prediction of Drag Reduction in Supersonic and Hypersonic Flows with Counterflow Jets

Computational fluid dynamics solutions of the flowfield of a truncated cone-cylinder with and without counterflow jets have been obtained for the short penetration mode (SPM) and long penetration mode (LPM) of the freestream-counterflow jet interaction flowfield. For the case without the counterflow jet, the comparison of the normalized surface pressures showed very good agreement with experimental data. For the case with the SPM jet, the predicted surface pressures did not compare as well with the experimental data upstream of the expansion corner, while aft of the expansion corner, the comparison of the solution and the data is seen to give much better agreement. The difference in the prediction and the data could be due to the transient character of the jet penetration modes, possible effects of the plasma physics that are not accounted for here, or even the less likely effect of flow turbulence, etc. For the LPM jet computations, one-dimensional isentropic relations were used to derived the jet exit conditions in order to obtain the LPM solutions. The solution for the jet exit Mach number of 3 shows a jet penetration several times longer than that of the SPM, and therefore much weaker bow shock, with an attendant reduction in wave drag. The LPM jet is, in essence, seen to be a "pencil" of fluid, with much higher dynamic pressure, embedded in the oncoming supersonic or hypersonic freestream. The methodology for determining the conditions for the LPM jet could enable a practical approach for the design and application of counterflow LPM jets for the reduction of wave drag and heat flux, thus significantly enhancing the aerodynamic characteristics and aerothermal performance of supersonic and hypersonic vehicles. The solutions show that the qualitative flow structure is very well captured. The obtained results, therefore, suggest that counterflowing jets are viable candidate technology concepts that can be employed to give significant reductions in wave drag, heat flux, and other attendant aerodynamic benefits.

Daso, Endwell O.↗

Measurements toward refined methane emission factors from industrial and commercial natural gas meters

The methane emission factors used in the U.S. EPA Greenhouse Gas Inventory (GHGI) for several categories of equipment in the natural gas supply chain currently have large uncertainties. The purpose of this project was to focus on one of those categories, industrial/commercial customer meters. The potential effect of the uncertainty for this category could be large due to the 5.6 million meters nationwide. We divided the country into six regions and worked extensively with local natural gas distribution companies to gain access to the meters. Ten weeks of measurements were conducted with an additional three weeks spent later revisiting the first sites. Sites were selected pseudo-randomly, by first randomly selecting a location then driving to as many meters as possible during that day, then randomly selecting another starting meter for the next day. At each site, every component was scanned with a combustible gas indicator (CGI), all components were counted, and all leaks with indications above 100ppm were logged. For 3 of the 10 weeks of measurements all leaks above 100ppm were quantified and for the remaining seven only leaks with an indication concentration above 22,500 ppm (45% of lower explosive limit) were quantified. Leaks were quantified using an enclosure, a vacuum pump, and methane sensor (either a CGI or Los Gatos Research Greenhouse Gas Analyzer). Through the initial visits 18,934 components were scanned, resulting in 1,170 leak indications above 100ppm, 351 leaks quantified at 174 different meter sets. The data was collected in a way so that it could be stratified by region, meter type, and component type. The largest number of components scanned were valves (4908) and flanges (4571). Very preliminary analysis of the data indicates that the mean leak size (not by meter) by region was Southeast (0.78 ± 2.2 lpm) Southwest (0.63 ± 1.5 lpm), Rocky Mountain (0.54 ± 1.3 lpm) Northeast (0.14 ± 0.56 lpm), Midwest (0.14 ± 0.56 lpm), and Pacific (0.07 ± 0.56 lpm). We also have determined that of the component types logged, roughly 2 – 5% of all components leaked. Our results are only preliminary, but initial indications are that based on data from this study, the current emission factors could increase by a factor of 5 to 10. Data analysis is ongoing to verify.

03 NATURAL GAS↗

Long Penetration Mode Counterflowing Jets for Supersonic Slender Configurations - A Numerical Study

A novel approach of using counterflowing jets positioned strategically on the aircraft and exploiting its long penetration mode (LPM) of interaction towards sonic-boom mitigation forms the motivation for this study. Given that most previous studies on the counterflowing LPM jet have all been on blunt bodies and at high supersonic or hypersonic flow conditions, exploring the feasibility to obtain a LPM jet issuing from a slender body against low supersonic freestream conditions is the main focus of this study. Computational fluid dynamics computations of axisymmetric models (cone-cylinder and quartic geometry), of relevance to NASA's High Speed project, are carried out using the space-time conservation element solution element viscous flow solver with unstructured meshes. A systematic parametric study is conducted to determine the optimum combination of counterflowing jet size, mass flow rate, and nozzle geometry for obtaining LPM jets. Details from these computations will be used to assess the potential of the LPM counterflowing supersonic jet as a means of active flow control for enabling supersonic flight over land and to establish the knowledge base for possible future implementation of such technologies.

Venkatachari, Balaji Shankar↗

Development and Evaluation of Ensemble Consensus Precipitation Estimates over High Mountain Asia

Precipitation estimates are highly uncertain in complex regions such as High-Mountain Asia (HMA), where ground measurements are very difficult to obtain, and atmospheric dynamics poorly understood. Though gridded products derived from satellite-based observations and/or reanalysis can provide temporally and spatially distributed estimates of precipitation, there are significant inconsistencies in these products. As such, to date, there is little agreement in the community on the best and most accurate gridded precipitation product in HMA, which is likely area dependent because of HMA’s strong heterogeneities and complex orography. Targeting these gaps, this article presents the development of a consensus ensemble precipitation product using three gridded precipitation datasets (the Integrated Multi-satellitE Retrieals for Global Precipitation Measurement IMERG, the Climate Hazards group Infrared Precipitation with Stations CHIRPS, and the ECMWF Reanalysis ERA5) with a localized probability matched mean (LPM) approach. We evaluate the performance of the LPM estimate along with a simple ensemble mean (EM) estimate to overcome the differences and disparities of the three selected constituent products on long-term averages and trends in HMA. Our analysis demonstrates that LPM reduces the high biases embedded in the ensemble members and provides more realistic spatial patterns compared to EM. LPM is also a good alternative for merging data products with different spatio-temporal resolutions. By filtering disparities among the individual ensemble members, LPM overcomes the problem of a certain product performing well only in a particular area and provides a consensus estimate with plausible temporal trends.

Fadji Z Maina↗

Local Monte Carlo Implementation of the Non-Abelian Landau-Pomeranchuk-Migdal Effect

The non-Abelian Landau-Pomeranschuk-Migdal (LPM) effect arises from the quantum interference between spatially separated, inelastic radiation processes in matter. A consistent probabilistic implementation of this LPM effect is a prerequisite for extending the use of Monte Carlo (MC) event generators to the simulation of jetlike multiparticle final states in nuclear collisions. Here, we propose a local MC algorithm, which is based solely on relating the LPM effect to the probabilistic concept of formation time for virtual quanta. This accounts probabilistically for the characteristic L{sup 2} dependence of average parton energy loss and the characteristic 1/sq root(omega) modification of the non-Abelian LPM effect. Additional kinematic constraints are found to modify these L{sup 2} and omega dependencies characteristically in accordance with analytical estimates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A 20 GHz, high efficiency dual mode TWT for the ACTS program

The development of a 50 W/10 W dual mode K-band downlink TWT is examined, and its performance is evaluated. The designs of the electron gun, RF circuit, and collector for the TWT, which is enclosed in a capsule, are described. It is observed that the high power mode (HPM) power output is at 50 GHz and the low power mode (LPM) output is at 12 GHz; the saturated gain is 52.5 dB for HPM and 3 dB for LPM; the AM-PM is 4.2 dB; the HPM dc power output is 104 W; and the LPM dc output is 42 W; and the efficiency is 45 percent for the HPM and 28.6 percent for the LPM.

Muennemann, Frank↗

An Assessment of Helium Evolution from Helium-Saturated Propellant Depressurization in Space

Helium evolution from the transfer of helium-saturated propellant in space is quantified to assess its impacts from creating two-phase gas/liquid flow from the supply tank, gas injection into the receiving tank, and liquid discharge from the receiving tank. Propellant transfer takes place between two similar tanks whose maximum storage capacity is approximately 2.55 cubic meters each. The maximum on-orbit propellants transfer capability is 9000 lbm (fuel and oxidizer). The transfer line is approximately 1.27 cm in diameter and 6096 cm in length and comprised of the fluid interconnect system (FICS), the orbiter propellant transfer system (OPTS), and the International Space Station (ISS) propulsion module (ISSPM). The propellant transfer rate begins at approximately 11 liter per minute (lpm) and subsequently drops to approximately 0.5 lpm. The tank nominal operating pressure is approximately 1827 kPa (absolute). The line pressure drops for Monomethy1hydrazine (MMH) and Nitrogen tetroxide (NTO) at 11.3 lpm are approximately 202 kPa and 302 kPa, respectively. The pressure-drop results are based on a single-phase flow. The receiving tank is required to vent from approximately 1827 kPa to a lower pressure to affect propellant transfer. These pressure-drop scenarios cause the helium-saturated propellants to release excess helium. For tank ullage venting, the maximum volumes of helium evolved at tank pressure are approximately 0.5 ft3 for MMH and 2 ft3 for NTO. In microgravity environment, due to lack of body force, the helium evolution from a liquid body acts to propel it, which influences its fluid dynamics. For propellant transfer, the volume fractions of helium evolved at line pressure are 0.1% by volume for MMH and 0.6 % by volume for NTO at 11.3 lpm. The void fraction of helium evolved varies as an approximate second order power function of flow rate.

Nguyen, Bich N.↗

Recent Thermal and Hydraulic Stimulation Results at Raft River, ID EGS Site

The Raft River geothermal system, located 160 km northwest of Salt Lake City, Utah is the site of a Department of Energy Enhanced Geothermal System (EGS) stimulation demonstration project. The target well RRG-9 ST-1, is roughly 1.6 km (1 mile) south of the power plant. This well has undergone a series of thermal and hydraulic stimulation treatments. Furthermore, the well passes through approximately 1,524 m MD (5,000 ft. MD) of laterally discontinuous Quaternary and Tertiary volcanoclastic and volcanic rocks that unconformably overlie the Precambrian basement. The Elba Quartzite formation located in the Precambrian basement is the target zone for the stimulation program. Fluid injected into the well exits through a fracture zone in the Elba Quartzite at 1,567 m TVD (5,140 ft. TVD). In June 2013 low-rate stimulation began at RRG-9 ST-1 using injection water from the geothermal plant. The average injection rate, temperature, and well head pressure of the low-rate stimulation was 163 Lpm (43 gpm), 34°C, and 1,931kPa (280 psig), respectively. This injection continued through late August of 2013 when wellhead pressures were intentionally increased to approximately 5,516 kPa (800 psig) at approximately 984 Lpm (260 gpm). From September 12 to September 24, 2013 cold well water was injected. The average surface injection temperature was approximately 12°C. On September 25, 2013 injection of the warmer plant water was resumed. This was continued through the rest of 2013 and into 2014. Between April 1, 2014 and April 4, 2014, a higher rate hydraulic stimulation was conducted. Colder water (~10°C) was injected at rates of 20 bpm to 30 bpm (3,178 Lpm to 4,770 Lpm) at wellhead pressures of 5,861 kPa (850 psig) over approximately 24 hours. Microseismic activity was recorded near the Tertiary-Precambrian contact. Subsequently, injection of water from the plant was resumed. As of mid-January, 2015, over 666 million liters (176 million gallons) have been injected into the well. The fate of this water is the subject of ongoing numerical analyses and continuous site monitoring. Various analyses have been implemented to monitor and assess the ongoing stimulation program. Modified Hall plot analysis shows increasing conductivity and/or a decreasing skin factor around the wellbore. Since April, 2014, the injectivity index has increased significantly from 0.28 Lpm/kPa (0.5 gpm/psig) to 0.93 Lpm/kPa (1.7 gpm/psig).

enhanced geothermal system↗

The Problem of overlapping formation times: In-medium virtual corrections for QCD

High energy particles traversing through medium primarily lose energy by showering through hard bremsstrahlung and pair production. These splitting processes are coherent over large distances in the very high energy limit, leading to suppression from the Landau-Pomeranchuk-Migdal (LPM) effect. Avoiding soft-emission approximations, we study the cases where the coherence lengths of two consecutive splittings overlap (which is important for calculating corrections to LPM effect in QCD). Here, we will show how to compute in-medium virtual corrections to the leading order LPM emission rates for QCD. These loop corrections will be necessary for calculating properties of in-medium high energy parton showers. To simplify the calculations, we will focus on the all-gluon case and work in the large-Nc limit of QCD, where Nc is the number of colors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-medium loop corrections and longitudinally polarized gauge bosons in high-energy showers

The splitting processes of bremsstrahlung and pair production in a medium are coherent over large distances in the very high energy limit, which leads to a suppression known as the Landau-Pomeranchuk-Migdal (LPM) effect. We continue study of the case when the coherence lengths of two consecutive splitting processes overlap (which is important for understanding corrections to standard treatments of the LPM effect in QCD), avoiding soft-emission approximations. In this particular paper, we show (i) how the “instantaneous” interactions of Light-Cone Perturbation Theory must be included in the calculation to account for effects of longitudinally-polarized gauge bosons in intermediate states, and (ii) how to compute virtual corrections to LPM emission rates, which will be necessary in order to make infrared-safe calculations of the characteristics of in-medium QCD showering of high-energy partons. In order to develop these topics in as simple a context as possible, we will focus in the current paper not on QCD but on large-N f QED, where N f is the number of electron flavors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Yap1/Taz are essential for the liver development in zebrafish

Highlights: • Taz is significantly up-regulated in zebrafish yap1 mutants. • yap1{sup −/−}; taz{sup +/−} embryos are defective in digestive organs development. • Mutations in yap1{sup −/−}; taz{sup +/−} impair cell proliferation in liver and movement of LPM. • Taz can substituteYap1's function in liver development in zebrafish. Hippo pathway regulates cell proliferation and differentiation. Yes-associated protein (Yap) and transcriptional coactivator with PDZ-binding motif (Taz) are effectors of Hippo pathway. The function of Yap/Taz in embryonic liver development has yet to be reported. Here yap1 and taz were found expressed in liver and other digestive organs in zebrafish embryos, and knockout of yap1 or taz did not lead to visible defects during embryogenesis. Interestingly, Taz was significantly increased in yap1 mutants, which may account for their normal development, albeit losing Yap1. However, yap1{sup −/−}; taz{sup +/-} embryos exhibited smaller digestive organs, and more than half of them showed bilateral livers and pancreas and non-looped intestines. Further analysis revealed that the disrupted gene function in yap1{sup −/−}; taz{sup +/-} embryos did not disturb liver bud formation, but instead impaired cell proliferation in liver and movement of the neighboring lateral plate mesoderm (LPM). Overexpression of wild type yap1 or taz could rescue the defective liver phenotypes in yap1{sup −/−}; taz{sup +/-} embryos, indicating that Yap1 cooperate with Taz to regulate the liver development. In addition, Yap1 was found to function in a Tead-dependent manner in the liver development. Our results suggest that Yap1/Taz regulate LPM movement and promote cell proliferation to ensure proper liver development in zebrafish.

60 APPLIED LIFE SCIENCES↗

Vibrational levels of a generalized Morse potential

A Generalized Morse Potential (GMP) is an extension of the Morse Potential (MP) with an additional exponential term and an additional parameter that compensate for MP’s erroneous behavior in the long range part of the interaction potential. Because of the additional term and parameter, the vibrational levels of the GMP cannot be solved analytically, unlike the case for the MP. We present several numerical approaches for solving the vibrational problem of the GMP based on Galerkin methods, namely, the Laguerre Polynomial Method (LPM), the Symmetrized LPM, and the Polynomial Expansion Method (PEM), and apply them to the vibrational levels of the homonuclear diatomic molecules B 2 , O 2 , and F 2 , for which high level theoretical near full configuration interaction (CI) electronic ground state potential energy surfaces and experimentally measured vibrational levels have been reported. Overall, the LPM produces vibrational states for the GMP that are converged to within spectroscopic accuracy of 0.01 cm –1 in between 1 and 2 orders of magnitude faster and with much fewer basis functions/grid points than the Colbert–Miller Discrete Variable Representation (CN-DVR) method for the three homonuclear diatomic molecules examined in this study.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Landau-Pomeranchuk-Midgal effect and charm production in p p collisions at energies available at the CERN Large Hadron Collider using the parton cascade model

We study the impact of the Landau-Pomeranchuk-Midgal (LPM) effect on the dynamics of parton interactions in proton-proton collisions at energies available at the CERN Large Hadron Collider. For our investigation we utilize a microscopic kinetic theory based on the Boltzmann equation. The calculation traces the space-time evolution of the cascading partons interacting via semihard pQCD scatterings and fragmentations. We focus on the impact of the LPM effect on the production of charm quarks, since their production is exclusively governed by processes well described in our kinetic theory. Furthermore, the LPM effect is found to become more prominent as the collision energy rises and at central rapidities, and may significantly affect the model's predicted charm distributions at low momenta.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lunar portable magnetometer experiment

The purpose of the Apollo 16 lunar portable magnetometer (LPM) experiment is to measure the permanent magnetic field at different geological sites on the lunar surface. The LPM field measurements are a vector sum of the steady remanent field from the lunar crust and of the time-varying ambient fields. The remanent magnetic fields measured in the Descartes region are the largest extraterrestrial fields yet measured in situ. These measurements show for the first time that the Descartes highlands have a stronger remanent magnetization than do the mare regions of the previous Apollo landing sites. The experimental technique used in the LPM experiment is described and the preliminary results obtained are discussed.

Dyal, P.↗