Search NASA⌕ Search

SEARCH · Search NASA

Results for “LUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Experimental Relationship Between Compressional Wave Attenuation and Surface Strains in Brittle Rock

Linear ultrasonic testing (LUT) has been extensively used as a tool for the evaluation of damage processes in various materials ranging from synthetic metals to natural geomaterials, such as rocks. A key limitation of LUT-based damage studies to date is the lack of explicit evidence used in associating material damage with the changes in measured LUT attributes (e.g., ultrasonic wave amplitude and velocity). In this study, the evolution of the full-field strains in brittle rock specimens (Lyons sandstone) subjected to failure are analyzed in real time and linked with the changes in the ultrasonic wave amplitude in localized areas illuminated by ultrasonic beams, termed as the ultrasonic image areas. The noncontact optical full-field displacement measurement method of 2-D digital image correlation is implemented in combination with the LUT procedure to continuously track changes in the ultrasonic wave amplitude with the evolution of strains across the surface of the uniaxially loaded intact rock specimens. The ultrasonic amplitude showed near-linear correlation with the intensity of inelastic tensile strain recorded in the rock specimens. The results from the study corroborate that the ultrasonic changes are in fact influenced by the regions of tensile cracking, which is the primary inelastic deformation mechanism in brittle rocks.

15 GEOTHERMAL ENERGY↗

SU-E-T-169: Characterization of Pacemaker/ICD Dose in SAVI HDR Brachytherapy

Purpose: It is important to estimate dose to pacemaker (PM)/Implantable Cardioverter Defibrillator (ICD) before undertaking Accelerated Partial Breast Treatment using High Dose Rate (HDR) brachytherapy. Kim et al. have reported HDR PM/ICD dose using a single-source balloon applicator. To the authors knowledge, there have so far not been any published PM/ICD dosimetry literature for the Strut Adjusted Volume Implant (SAVI, Cianna Medical, Aliso Viejo, CA). This study aims to fill this gap by generating a dose look up table (LUT) to predict maximum dose to the PM/ICD in SAVI HDR brachytherapy. Methods: CT scans for 3D dosimetric planning were acquired for four SAVI applicators (6−1-mini, 6−1, 8−1 and 10−1) expanded to their maximum diameter in air. The CT datasets were imported into the Elekta Oncentra TPS for planning and each applicator was digitized in a multiplanar reconstruction window. A dose of 340 cGy was prescribed to the surface of a 1 cm expansion of the SAVI applicator cavity. Cartesian coordinates of the digitized applicator were determined in the treatment leading to the generation of a dose distribution and corresponding distance-dose prediction look up table (LUT) for distances from 2 to 15 cm (6-mini) and 2 to 20 cm (10–1).The deviation between the LUT doses and the dose to the cardiac device in a clinical case was evaluated. Results: Distance-dose look up table were compared to clinical SAVI plan and the discrepancy between the max dose predicted by the LUT and the clinical plan was found to be in the range (−0.44%, 0.74%) of the prescription dose. Conclusion: The distance-dose look up tables for SAVI applicators can be used to estimate the maximum dose to the ICD/PM, with a potential usefulness for quick assessment of dose to the cardiac device prior to applicator placement.

60 APPLIED LIFE SCIENCES↗

MODIS Solar Diffuser On-Orbit Degradation Characterization Using Improved SDSM Screen Modeling

The Solar Diffuser (SD) is used for the MODIS reflective solar bands (RSB) calibration. An on-board Solar Diffuser Stability Monitor (SDSM) tracks the degradation of its on-orbit bi-directional reflectance factor (BRF). To best match the SDSM detector signals from its Sun view and SD view, a fixed attenuation screen is placed in its Sun view path, where the responses show ripples up to 10%, much larger than design expectation. Algorithms have been developed since the mission beginning to mitigate the impacts of these ripples. In recent years, a look-up-table (LUT) based approach has been implemented to account for these ripples. The LUT modeling of the elevation and azimuth angles is constructed from the detector 9 (D9) of SDSM observations in the MODIS early mission. The response of other detectors is normalized to D9 to reduce the ripples observed in the sun-view data. The accuracy of all detectors degradation estimation depends on how well the D9 approximated. After multiple years of operation (Terra: 16 years; Aqua: 14 years), degradation behavior of all detectors can be monitored by their own. This paper revisits the LUT modeling and proposes a dynamic scheme to build a LUT independently for each detector. Further refinement in the Sun view screen characterization will be highlighted to ensure the degradation estimation accuracy. Results of both Terra and Aqua SD on-orbit degradation are derived from the improved modeling and curve fitting strategy.

Chen, H.↗

The effects of terrestrial weathering on samarium-neodymium isotopic composition of ordinary chondrites

Following their fall to Earth, meteorites experience weathering. In this systematic study, we evaluate the trace element composition of ordinary chondrites from the Antarctic cold desert, and Atacama (Chile) and Lut (Iran) hot deserts, with an emphasis on rare earth elements (REE). Our data confirms that terrestrial weathering of meteorites in hot deserts changes their trace element (Sr, Ba, REE, Hf, Th, and U) concentrations. However, weathering effects in majority of Antarctic samples are limited to slight Ba, REE, Hf, and Th depletions and in some case to U enrichment. In comparison to the Antarctic meteorites, hot desert samples show greater disturbances and REE fractionation relative to the average fall values. We measured the Sm-Nd isotopic composition of the hot desert meteorites that have heavily affected REE compositions. Our Sm-Nd isotopic data show a significant effect of terrestrial weathering evidenced by non-CHUR (147)Sm/(144)Nd and (143)Nd/(144)Nd ratios. Measurements show a higher variation and lower values of (147)Sm/(144)Nd for the Atacama samples than those from the Lut Desert. Deviations from CHUR (147)Sm/(144)Nd value are in positive accordance with the degree of La/Lu fractionation caused by weathering. The ɛNd values of Atacama and Lut deserts meteorites range from −2.20 to +1.61, which is wider than the −1.07 to +0.64 range for falls. We suggest that disturbance of primary Sm/Nd ratios resulting from mixing with terrestrial components originating from soil during weathering is responsible for lower (147)Sm/(144)Nd ratio in these meteorites. The majority of the Atacama meteorites regardless of their weathering degrees have their REE compositions and ɛNd affected by terrestrial contamination. Both (147)Sm/(144)Nd ratio and ɛNd values show no straightforward relationship with weathering degree. However, in both cases the samples with the highest negative isotopic disturbances are H chondrites from the Atacama and Lut deserts. In addition, Ba concentration shows a negative correlation with (147)Sm/(144)Nd ratio. Care must be taken into account while dealing with samples collected from hot deserts, even fresh-looking ones.

Isotope geochemistry↗

Towards operational atmospheric correction of airborne hyperspectral imaging spectroscopy: Algorithm evaluation, key parameter analysis, and machine learning emulators

Atmospheric correction of airborne hyperspectral imaging spectroscopy (AHIS) to obtain high-quality surface reflectance is the prerequisite for remote sensing applications. Over the last decades, different atmospheric correction methods have been developed based on radiative transfer models (RTMs), however, the relative performances of different algorithms are unclear. Automated operational atmospheric correction methods to process large-volume AHIS data in a high-accurate and high-throughput manner are still lacking. Therefore, this study proposed an operational atmospheric correction pipeline for deriving surface reflectance from AHIS data. To ensure the accuracy and efficiency of the pipeline, we focused on three specific aspects: (1) selecting a suitable RTM for the development of atmospheric lookup tables (LUTs) by comparing the commercial MODerate resolution atmospheric TRANsmission (MODTRAN) and open-sourced Library for Radiative TRANsfer (LibRadTRAN) models, where the widely-used software, Atmospheric/Topographic Correction for Airborne Imagery (ATCOR), was used as benchmarks; (2) identifying key atmospheric correction parameters and determining suitable sources for parameter retrievals including AHIS, Moderate Resolution Imaging Spectroradiometer (MODIS), and AErosol RObotic NETwork (AERONET); and (3) testing the performance of using machine learning emulators to speed up the RTM-based atmospheric correction. Results indicate that (1) atmospheric correction based on MODTRAN LUTs can produce surface reflectance accurately with mean absolute errors < 0.05 and cosine similarities > 0.98 compared to field measurements, which is comparable to the software ATCOR and slightly outperforms the LibRadTRAN LUTs; (2) sobol global sensitivity analysis demonstrates that in the atmospheric correction, visibility and water vapor are two key parameters that can be accurately derived from AHIS in contrast to MODIS or AERONET data; and (3) Random Forest emulators can produce accurate estimations of surface reflectance with mean absolute errors < 0.03 and cosine similarities > 0.98 for higher processing efficiency and determine a suitable set of wavelengths for retrieving atmospheric visibility and water vapor. In conclusion, the proposed atmospheric correction pipeline also improved the four-stream radiative transfer theory for airborne applications by considering adjacent effects from airborne surrounding pixels and can also be applied for atmospheric correction of hyperspectral data from spaceborne missions.

47 OTHER INSTRUMENTATION↗

Multiscale and multiphysics FEA simulation and materials optimization for laser ultrasound transducers

In this study, the relationship between the nanocomposite design and the laser ultrasound transducer (LUT) characteristics was investigated through simulations in multiple scale levels for material behavior, device response, and acoustic wave propagation in media. First, the effects of the nanoparticle size and concentration on the effective properties of composites were quantitatively investigated with the finite element analysis (FEA) method. Second, the effective properties of the nanocomposite were assigned to the layer, which is modeled as a homogeneous material, in the FEA for the LUT simulating the energy conversion from the incident laser to the acoustic wave. Finally, the ultrasound propagation in the water was calculated by a theoretical wave propagation model. The FEA-based prediction was compared with the experimental data in the literature and a theoretical analysis for LUT based on Thermal-Acoustic coupling. As a result, the ultrasound waves on the transducer surface and at a distance in the water could be predicted. Based on the hierarchically integrated prediction procedure, the optimal conditions of the photoacoustic nanocomposites were investigated through the parametric study with the particle size and concentration as variables. The results guide the material designs optimized for different device characteristics, such as high pressure and broad bandwidth.

36 MATERIALS SCIENCE↗

Illumination of Damage in Intact Rocks by Ultrasonic Transmission-Reflection and Digital Image Correlation

aboratory-scale experiments on intact rocks are critical to the development of physics-based fundamental understanding of various geophysical phenomena. In this work, the capability of ultrasonic wave transmission (T-mode) and reflection (R-mode) to monitor damage progression in uniaxially loaded prismatic intact rock specimens has been analyzed, as it is imperative to study the observations and document the capabilities of these techniques in a controlled environment. This study is novel in the sense that the R-mode linear ultrasonic testing (LUT) has been rarely employed in studying intact rock damage processes in a laboratory setting, with most of the studies utilizing a direct transmission (T-mode) approach or focusing on macroscopically fractured material. The two-dimensional digital image correlation (2-D DIC) full-field strain measurement approach was also used in-sync with the LUT monitoring to explicitly correlate the stress-induced damage in the specimens with the changes observed in the ultrasonic (T-mode and R-mode) signals. The results show that both the T-mode and R-mode LUT approaches are sensitive to detect the evolution of tensile and shear damage in the specimens, with the R-mode ultrasonic signals showing higher degree of sensitivity to the damage in the rocks, immediately following the initiation of damage in the rock volume.

58 GEOSCIENCES↗

Local unitary transformation method toward practical electron correlation calculations with scalar relativistic effect in large-scale molecules

In order to perform practical electron correlation calculations, the local unitary transformation (LUT) scheme at the spin-free infinite-order Douglas–Kroll–Hess (IODKH) level [J. Seino and H. Nakai, J. Chem. Phys.136, 244102 (2012); J. Seino and H. Nakai, J. Chem. Phys.137, 144101 (2012)], which is based on the locality of relativistic effects, has been combined with the linear-scaling divide-and-conquer (DC)-based Hartree–Fock (HF) and electron correlation methods, such as the second-order Møller–Plesset (MP2) and the coupled cluster theories with single and double excitations (CCSD). Numerical applications in hydrogen halide molecules, (HX){sub n} (X = F, Cl, Br, and I), coinage metal chain systems, M{sub n} (M = Cu and Ag), and platinum-terminated polyynediyl chain, trans,trans-((p-CH{sub 3}C{sub 6}H{sub 4}){sub 3}P){sub 2}(C{sub 6}H{sub 5})Pt(C≡C){sub 4}Pt(C{sub 6}H{sub 5})((p-CH{sub 3}C{sub 6}H{sub 4}){sub 3}P){sub 2}, clarified that the present methods, namely DC-HF, MP2, and CCSD with the LUT-IODKH Hamiltonian, reproduce the results obtained using conventional methods with small computational costs. The combination of both LUT and DC techniques could be the first approach that achieves overall quasi-linear-scaling with a small prefactor for relativistic electron correlation calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A pencil beam algorithm for helium ion beam therapy

Purpose: To develop a flexible pencil beam algorithm for helium ion beam therapy. Dose distributions were calculated using the newly developed pencil beam algorithm and validated using Monte Carlo (MC) methods. Methods: The algorithm was based on the established theory of fluence weighted elemental pencil beam (PB) kernels. Using a new real-time splitting approach, a minimization routine selects the optimal shape for each sub-beam. Dose depositions along the beam path were determined using a look-up table (LUT). Data for LUT generation were derived from MC simulations in water using GATE 6.1. For materials other than water, dose depositions were calculated by the algorithm using water-equivalent depth scaling. Lateral beam spreading caused by multiple scattering has been accounted for by implementing a non-local scattering formula developed by Gottschalk. A new nuclear correction was modelled using a Voigt function and implemented by a LUT approach. Validation simulations have been performed using a phantom filled with homogeneous materials or heterogeneous slabs of up to 3 cm. The beams were incident perpendicular to the phantoms surface with initial particle energies ranging from 50 to 250 MeV/A with a total number of 10{sup 7} ions per beam. For comparison a special evaluation software was developed calculating the gamma indices for dose distributions. Results: In homogeneous phantoms, maximum range deviations between PB and MC of less than 1.1% and differences in the width of the distal energy falloff of the Bragg-Peak from 80% to 20% of less than 0.1 mm were found. Heterogeneous phantoms using layered slabs satisfied a {gamma}-index criterion of 2%/2mm of the local value except for some single voxels. For more complex phantoms using laterally arranged bone-air slabs, the {gamma}-index criterion was exceeded in some areas giving a maximum {gamma}-index of 1.75 and 4.9% of the voxels showed {gamma}-index values larger than one. The calculation precision of the presented algorithm was considered to be sufficient for clinical practice. Although only data for helium beams was presented, the performance of the pencil beam algorithm for proton beams was comparable. Conclusions: The pencil beam algorithm developed for helium ions presents a suitable tool for dose calculations. Its calculation speed was evaluated to be similar to other published pencil beam algorithms. The flexible design allows easy customization of measured depth-dose distributions and use of varying beam profiles, thus making it a promising candidate for integration into future treatment planning systems. Current work in progress deals with RBE effects of helium ions to complete the model.

60 APPLIED LIFE SCIENCES↗

LANDSAT D local user terminal study

The effect of the changes incorporated in the LANDSAT D system on the ability of a local user terminal to receive, record and process data in real time was studied. Alternate solutions to the problems raised by these changes were evaluated. A loading analysis was performed in order to determine the quantities of data that a local user terminal (LUT) would be interested in receiving and processing. The number of bits in an MSS and a TM scene were calculated along with the number of scenes per day that an LUT might require for processing. These then combined to a total number of processed bits/day for an LUT as a function of sensor and coverage circle radius.

Alexander, L.↗

Status of the MODIS Level 1B Algorithms and Calibration Tables

The Moderate Resolution Imaging Spectroradiometer (MODIS) makes observations using 36 spectral bands with wavelengths from 0.41 to 14.4 m and nadir spatial resolutions of 0.25km, 0.5km, and 1km. It is currently operating onboard the NASA Earth Observing System (EOS) Terra and Aqua satellites, launched in December 1999 and May 2002, respectively. The MODIS Level 1B (L1B) program converts the sensor's on-orbit responses in digital numbers to radiometrically calibrated and geo-located data products for the duration of each mission. Its primary data products are top of the atmosphere (TOA) reflectance factors for the sensor's reflective solar bands (RSB) and TOA spectral radiances for the thermal emissive bands (TEB). The L1B algorithms perform the TEB calibration on a scan-by-scan basis using the sensor's response to the on-board blackbody (BB) and other parameters which are stored in Lookup Tables (LUTs). The RSB calibration coefficients are processed offline and regularly updated through LUTs. In this paper we provide a brief description of the MODIS L1B calibration algorithms and associated LUTs with emphasis on their recent improvements and updates developed for the MODIS collection 5 processing. We will also discuss sensor on-orbit calibration and performance issues that are critical to maintaining L1B data product quality, such as changes in the sensor's response versus scan-angle.

MODIS LEVEL 1B ALGORITHMS↗

The Effects of an Absorbing Smoke Layer on MODIS Marine Boundary Layer Cloud Optical Property Retrievals and Radiative Forcing

Clouds, aerosols, and their interactions are widely considered to be key uncertainty components in our current understanding of the Earth's atmosphere and radiation budget. The work presented here is focused on the quasi-permanent marine boundary layer . (MBL) clouds off the southern Atlantic coast of Africa and the effects on MODIS cloud optical property retrievals (MOD06) of an overlying absorbing smoke layer. During much of August and September, a persistent smoke layer resides over this region, produced from extensive biomass burning throughout the southern African savanna. The resulting absorption, which increases with decreasing wavelength, potentially introduces biases into the MODIS cloud optical property retrievals of the underlying MBL clouds. This effect is more pronounced in the cloud optical thickness retrievals, which over ocean are derived from the wavelength channel centered near 0.86 micron (effective particle size retrievals are derived from the longer-wavelength near-IR channels at 1.6, 2.1, and 3.7 microns). Here, the spatial distributions of the scalar statistics of both the cloud and aerosol layers are first determined from the CALIOP 5 km layer products. Next, the MOD06 look-up tables (LUTs) are adjusted by inserting an absorbing smoke layer of varying optical thickness over the cloud. Retrievals are subsequently performed for a subset of MODIS pixels collocated with the CALIOP ground track, using smoke optical thickness from the CALIOP 5km aerosol layer product to select the appropriate LUT. The resulting differences in cloud optical property retrievals due to the inclusion of the smoke layer in the LUTs will be examined. In addition, the direct radiative forcing of this smoke layer will be investigated from the perspective of the cloud optical property retrieval differences.

Meyer, Kerry↗

The Next-Generation Goddard Convective-Stratiform Heating Algorithm: New Tropical and Warm-Season Retrievals for GPM

The Goddard convective-stratiform heating (CSH) algorithm, used to estimate cloud heating in support of the Tropical Rainfall Measuring Mission (TRMM), is upgraded in support of the Global Precipitation Measurement (GPM) mission. The algorithm's lookup tables (LUTs) are revised using new and additional cloud-resolving model (CRM) simulations from the Goddard Cumulus Ensemble (GCE) model, producing smoother heating patterns that span a wider range of intensities because of the increased sampling and finer GPM product grid. Low-level stratiform cooling rates are reduced in the land LUTs for a given rain intensity because of the rain evaporation correction in the new four-class ice (4ICE) scheme. Additional criteria, namely, echo-top heights and low-level reflectivity gradients, are tested for the selection of heating profiles. Those resulting LUTs show greater and more precise variation in their depth of heating as well as a tendency for stronger cooling and heating rates when low-level dBZ values decrease toward the surface. Comparisons versus TRMM for a 3-month period show much more low-level heating in the GPM retrievals because of increased detection of shallow convection, while upper-level heating patterns remain similar. The use of echo tops and low-level reflectivity gradients greatly reduces midlevel heating from ~2 to 5 km in the mean GPM heating profile, resulting in a more top-heavy profile like TRMM versus a more bottom-heavy profile with much more midlevel heating. Integrated latent heating rates are much better balanced versus surface rainfall for the GPM retrievals using the additional selection criteria with an overall bias of +4.3%.

Lang, Stephen E.↗

The AERONET Version 3 Aerosol Retrieval Algorithm, Associated Uncertainties and Comparisons to Version 2

The Aerosol Robotic Network (AERONET) Version 3 (V3) aerosol retrieval algorithm is described, which is based on the Version 2 (V2) algorithm with numerous updates. Comparisons of V3 aerosol retrievals to those of V2 are presented, along with a new approach to estimate uncertainties in many of the retrieved aerosol parameters. Changes in the V3 aerosol retrieval algorithm include (1) a new polarized radiative transfer code (RTC), which replaced the scalar RTC of V2, (2) detailed characterization of gas absorption by adding NO2 and H2O to specify total gas absorption in the atmospheric column, specification of vertical profiles of all the atmospheric species, (3) new bidirectional reflectance distribution function (BRDF) parameters for land sites adopted from the MODIS BRDF/Albedo product, (4) a new version of the extraterrestrial solar flux spectrum, and (5) a new temperature correction procedure of both direct Sun and sky radiance measurements. The potential effect of each change in V3 on single scattering albedo (SSA) retrievals was analyzed. The operational almucantar retrievals of V2 versus V3 were compared for four AERONET sites: GSFC, Mezaira, Mongu, and Kanpur. Analysis showed very good agreement in retrieved parameters of the size distributions. Comparisons of SSA retrievals for dust aerosols (Mezaira) showed a good agreement in 440 nm SSA, while for longer wavelengths V3 SSAs are systematically higher than those of V2, with the largest mean difference at 675 nm due to cumulative effects of both extraterrestrial solar flux and BRDF changes. For non-dust aerosols, the largest SSA deviation is at 675 nm due to differences in extraterrestrial solar flux spectrums used in each version. Further, the SSA 675 nm mean differences are very different for weakly (GSFC) and strongly (Mongu) absorbing aerosols, which is explained by the lower sensitivity to a bias in aerosol scattering optical depth by less absorbing aerosols. A new hybrid (HYB) sky radiance measurement scan is introduced and discussed. The HYB combines features of scans in two different planes to maximize the range of scattering angles and achieve scan symmetry, thereby allowing for cloud screening and spatial averaging, which is an advantage over the principal plane scan that lacks robust symmetry. We show that due to an extended range of scattering angles, HYB SSA retrievals for dust aerosols exhibit smaller variability with solar zenith angles (SZAs) than those of almucantar (ALM), which allows extension of HYB SSA retrievals to SZAs less than 50∘ to as small as 25∘. The comparison of SSA retrievals from closely time-matched HYB and ALM scans in the 50 to 75∘ SZA range showed good agreement with the differences below ∼0.005. We also present an approach to estimate retrieval uncertainties which utilizes the variability in retrieved parameters generated by perturbing both measurements and auxiliary input parameters as a proxy for retrieval uncertainty. The perturbations in measurements and auxiliary inputs are assumed as estimated biases in aerosol optical depth (AOD), radiometric calibration of sky radiances combined with solar spectral irradiance, and surface reflectance. For each set of Level 2 Sun/sky radiometer observations, 27 inputs corresponding to 27 combinations of biases were produced and separately inverted to generate the following statistics of the inversion results: average, standard deviation, minimum and maximum values. From these statistics, standard deviation (labeled U27) is used as a proxy for estimated uncertainty, and a lookup table (LUT) approach was implemented to reduce the computational time. The U27 climatological LUT was generated from the entire AERONET almucantar (1993–2018) and hybrid (2014–2018) scan databases by binning U27s in AOD (440 nm), Angström exponent (AE, 440–870 nm), and SSA (440, 675, 870, 1020 nm). Using this LUT approach, the uncertainty estimates U27 for each individual V3 Level 2 retrieval can be obtained by interpolation using the corresponding measured and inverted combination of AOD, AE, and SSA.

Aliaksandr Siniuk↗

Prostatic Artery Embolization (PAE) for Symptomatic Benign Prostatic Hyperplasia (BPH): Part 1, Pathological Background and Clinical Implications

Pathological features of benign prostatic hyperplasia (BPH) dictate various responses to prostatic artery embolization (PAE). Typically, BPH originates in the transition zone and periurethral region, where should be considered the primary target area in PAE procedures. Given that histological heterogeneity of components in hyperplasia nodules, epithelial or stromal, identifying the more responsive nodules to PAE will have clinical implications. Since some lower urinary tract symptoms (LUTS) in patients with BPH are usually related to bladder outlet obstruction-induced changes in bladder function rather than to outflow obstruction directly, proper selection of candidate patients prior to PAE is of great clinical importance. BPH is a typical chronic progressive condition, suggesting PAE could aim not only to relieve LUTS but also to delay or prevent the clinical progression. Awareness of the pathological background of BPH is essential for interventional radiologists to improve clinical outcomes and develop new treatment strategies in clinical practice of PAE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Study Using 100–300 Versus 300–500 μm Microspheres for Symptomatic Patients Due to Enlarged-BPH Prostates

PurposeThe purpose of the study was to compare safety and efficacy outcomes following prostate artery embolization (PAE) for the treatment of lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH) with 100–300 versus 300–500 μm tris-acryl gelatin microspheres.Materials and MethodsPatients were prospectively treated between August 2011 and June 2013 to receive PAE with 100–300 μm (group A) or 300–500 μm (group B) tris-acryl gelatin microspheres. Patients were followed for a minimum of 12 months and were assessed for changes in International Prostate Symptom Score (IPSS), quality of life (QoL) index, prostate volume determined by magnetic resonance imaging, serum prostate specific antigen (PSA), and maximum urine flow rate (Q{sub max}), as well as any treatment-related adverse events.ResultsFifteen patients were included in each group, and PAE was technically successful in all cases. Both groups experienced significant improvement in mean IPSS, QoL, prostate volume, PSA, and Q{sub max} (p < 0.05 for all). The differences observed between the two groups included a marginally insignificant more adverse events (p = 0.066) and greater mean serum PSA reduction at 3 months of follow-up (p = 0.056) in group A.ConclusionsBoth 100–300 and 300–500 μm microspheres are safe and effective embolic agents for PAE to treat LUTS-related to BPH. Although functional and imaging outcomes did not differ significantly following use of the two embolic sizes, the greater incidence of adverse events with 100–300 μm microspheres suggests that 300–500 μm embolic materials may be more appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Systematic Review of Prostatic Artery Embolization in the Treatment of Symptomatic Benign Prostatic Hyperplasia

PurposeTo summarize current evidence on outcomes and complications of prostatic artery embolization as a treatment for patients with lower urinary tract symptoms secondary to benign prostatic hyperplasia.Methods and MaterialsA database search of MEDLINE, Embase, Web of Science, and Cochrane Library was performed for published literature up to August 2015 concerning PAE in the treatment of BPH. Inclusion and exclusion criteria were applied by two independent reviewers, and disagreements were resolved by consensus. Peer-reviewed studies concerning PAE with BPH with a sample size >10 and at least one measured parameter were included.ResultsThe search yielded 193 articles, of which ten studies representing 788 patients, with a mean age of 66.97 years, were included. Patients had LUTS ranging from moderate to severe. At 6 months following procedure, PV, PVR, Qmax, IPSS, and QoL were significantly improved (P < 0.05), while for PSA there was no significant change. At 12 and 24 months, PV, PSA, PVR, Qmax, IPSS, and QoL were significantly improved (P < 0.05). IIEF was unchanged at 6 and 12 months but was significantly reduced at 24 months.ConclusionThis suggests that PAE is effective in treating LUTS in the short and intermediate term.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recurrence of Lower Urinary Tract Symptoms Following Prostate Artery Embolization for Benign Hyperplasia: Single Center Experience Comparing Two Techniques

PurposeTo compare recurrence of lower urinary tract symptoms (LUTS) recurrence at 12 months following original prostate artery embolization (oPAE) or “proximal embolization first, then embolize distal” (PErFecTED) PAE for benign prostatic hyperplasia (BPH).Materials and Methods105 consecutive patients older than 45 years, with prostate size greater than 30 cm{sup 3}, International Prostate Symptom Score (IPSS) ≥ 8, quality of life (QoL) index ≥ 3, and refractory status or intolerance of medical management were prospectively enrolled between June 2008 and August 2013. The study was IRB-approved, and all patients provided informed consent. Patients underwent oPAE or PErFecTED PAE and were followed for at least 12 months. Technical success was defined as bilateral embolization and clinical success (non-recurrence) was defined as removal of the Foley catheter in patients with urinary retention, IPSS < 8 and QoL index < 3 at 12 months of follow-up. Nonparametric statistics were used to compare the study groups due to the size of the study population and distributions of clinical data.Results97 patients had 12-month data and were categorized as oPAE without recurrence (n = 46), oPAE with recurrence (n = 13), PErFecTED without recurrence (n = 36), or PErFecTED with recurrence (n = 2). Recurrence was significantly more common in oPAE patients (χ{sup 2}, p = 0.026). Unilateral embolization was significantly associated with recurrence among patients who underwent oPAE (χ{sup 2}, p = 0.032).ConclusionsBoth oPAE and PErFecTED PAE are safe and effective methods for treatment of LUTS, but PErFecTED PAE is associated with a significantly lower rate of symptom recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗