Search NASA⌕ Search

SEARCH · Search NASA

Results for “Lab-on-a-Chip”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

35 records · Page 2

Microfluidic Devices for Chemical and Biochemical Analysis in Microgravity

One often touted benefit of "Lab-on-a-Chip" devices is their potential for use in remote environments. The ultimate remote environment is outer space, and NASA has multiple needs in the area of analytical sensing capability in such an environment. In particular, we are interested in integrating microfluidic devices with NASA bioreactor systems. In such an integrated system, the microfluidic device will serve as a biosensor and be used for both feedback control and for detecting various bioproducts produced by cells cultured in the NASA bioreactors. As a first step in demonstrating the ability of microfluidic devices to operate under the extreme environmental conditions found in outer space, we constructed a portable, battery operated platform for testing under reduced gravity conditions on a NASA KC-135 reduced gravity research aircraft, (AKA "the vomit comet"). The test platform consisted of a microchip, two 0-8kV high voltage power supplies, a high voltage switch, a solid-state diode-pumped green laser, a channel photomultiplier, and an inertial mass measurement unit, all under the control of a laptop computer and powered by 10 D-cell alkaline batteries. Over the course of 4 KC-135 flights, 1817 fast electrophoretic separations of 4 amino acids and/or proteins were performed in a variety of gravitational environments including zero-G, Martian-G, lunar-G, and 2-G. Results from these experiments will be presented and discussed.

Roman, Gregory T.↗

Design and Modelling of a Microfluidic Electro-Lysis Device with Controlling Plates

Many Lab-on-Chip applications require sample pre-treatment systems. Using electric fields to perform cell-lysis in bio-MEMS systems has provided a powerful tool which can be integrated into Lab-on-a-Chip platforms. The major design considerations for electro-lysis devices include optimal geometry and placement of micro-electrodes, cell concentration, flow rates, optimal electric field (e.g. pulsed DC vs. AC), etc. To avoid electrolysis of the flowing solution at the exposed electrode surfaces, magnitudes and the applied voltages and duration of the DC pulse, or the AC frequency of the AC, have to be optimized for a given configuration. Using simulation tools for calculation of electric fields has proved very useful, for exploring alternative configurations and operating conditions for achieving electro cell-lysis. To alleviate the problem associated with low electric fields within the microfluidics channel and the high voltage demand on the contact electrode strips, two "control plates" are added to the microfluidics configuration. The principle of placing the two controlling plate-electrodes is based on the electric fields generated by a combined insulator/dielectric (gladwater) media. Surface charges are established at the insulator/dielectric interface. This paper discusses the effects of this interface charge on the modification of the electric field of the flowing liquid/cell solution.

Jenkins, A.↗

Next Generation LOCAD-PTS Cartridge Development

Future astrobiology exploration missions will require rapid, point-of-use techniques for surface science experiments and contamination monitoring. The Lab-On-a-Chip Application Development (LOCAD) team is developing operational instruments that advance spaceflight technologies to molecular-based methods. Currently, LOCAD-Portable Test System (PTS) is quantifying levels of the bacterial molecule endotoxin onboard the Internatioal Space Station. Future research and development will focus on more sensitive molecular techniques that expand the number of compounds detected to include beta-glucan from fungal cell walls.

Morris, H.↗

Rapid Biochemical Analysis on the International Space Station (ISS): Preparing for Human Exploration of the Moon and Mars

The Lab-on-a-Chip Application Development - Portable Test System, known as LOCAD-PTS, was launched to the International Space Station (ISS) aboard Space Shuttle Discovery (STS-116) on December 9th,2006. Since that time, it has remained onboard ISS and has been operated by the crew on 10 separate occasions LOCAD-PTS is a handheld device for rapid biochemical analysis; it consists of a spectrophotometer, a series of interchangeable cartridges, a pipette and several clean/sterilized swabbing kits to obtain samples from ISS surfaces. Sampling, quantitative analysis and data retrieval is performed onboard, therefore reducing the need to return samples to Earth. Less than 20 minutes are required from sampling to data, significantly faster than existing culture-based methods on ISS, which require 3-5 days. Different cartridges are available for the detection of different target molecules (simply by changing the formulation within each cartridge), thereby maximizing the benefit and applications addressed by a single instrument. Initial tests on ISS have focused on the detection of the bact.erial macromolecule endotoxin, a component of bacterial cell walls. LOCAD-PTS detects endotoxin with a cartridge that contains a formulation known as Limulus Amebocyte Lysate (LAL) assay. LAL is derived from blood of the horseshoe crab, Limulus polyphemus, and detects enodotoxin with an enzyme cascade that triggers generation Of a yellow colored dye, p-nitroanaline. The more p-nitroanaline product, the more endotoxin is in the original sample. To enable quantitative analysis, the absorbance of this color is measured by LOCAD-PTS through a 395 nm filter and compared with an internal calibration curve, to provide a reading on the LED display that ranges from 0.05 Endotoxin Units (EU)/ml to 5 EU/ml. Several surface sites were analyzed within ISS between March 2007 and February 2008, including multiple locations in the US Laboratory Destiny, Node 1 Unity, AMock, and Service Module Zvezda. The goals of this initial study were to i) test the cleanliness of reagents/supplies on orbit, ii) test the crew's ability to collect and process a sample in microgravity without contamination, iii) demonstrate nominal function of the LOCAD-PTS, and iv) provide a general survey of endotoxin within the ISS. The surface sites varied greatly in terms of their frequency-of-use and material texture/composition; from relatively smooth aluminum, to fabric, to the room temperature vulcanizing (RTV) rubber of a Extravehicular Mobility Unit (EMU) spacesuit. Results showed that: i) the swabbing kits and reagents remained clean on orbit, ii) the crew could collect and process a sample without contamination, and iii) the LOCAD-PTS functioned nominally in > 99% of the 55 tests completed. We will present detailed results of the survey of endotoxin on ISS surfaces. These results and technology are important in the near-term - by providing an extra tool in the toolbox for ISS microbial monitoring. They are also important in the longer term as valuable preparation for human exploration of the Moon and Mars. One of the proposed science goals for the human exploration of Mars will be to detect and characterize any indigenous biological molecules that may exist on the Martian surface. To achieve that goal, the crew must have the technology available onboard to differentiate indigenous biology from any terrestrial biological material brought to Mars by the spacecraft and crew (termed 'forward contamination'). The LAL assay is already one of the official methods used by NASA's planetary protection program to certify cleanliness of interplanetary robotic spacecraft prior to launch; and therefore endotoxin is a good marker of forward contamination (as well as other microbial molecules detectable with LOCAD-PTS e.g. box-1, 3-glucan and lipoteichoic acid). Furthermore, the distribution and abundance of these molecules on the ISS provides a good indicator of what to expect on the Crew Exploratioehicle Orion, the lunar lander Antares, and future crewed spacecraft destined for Mars. In addition, technology such as LOCAD-PTS has been proposed to help evaluate forward contamination during lunar surface operations by the crew, as preparation for the human exploration of Mars.

Maule, J.↗

Rapid Monitoring of Bacteria and Fungi aboard the International Space Station (ISS)

Microorganisms within spacecraft have traditionally been monitored with culture-based techniques. These techniques involve growth of environmental samples (cabin water, air or surfaces) on agar-type media for several days, followed by visualization of resulting colonies or return of samples to Earth for ground-based analysis. Data obtained over the past 4 decades have enhanced our understanding of the microbial ecology within space stations. However, the approach has been limited by the following factors: i) Many microorganisms (estimated > 95%) in the environment cannot grow on conventional growth media; ii) Significant time lags (3-5 days for incubation and up to several months to return samples to ground); iii) Condensation in contact slides hinders colony counting by crew; and iv) Growth of potentially harmful microorganisms, which must then be disposed of safely. This report describes the operation of a new culture-independent technique onboard the ISS for rapid analysis (within minutes) of endotoxin and beta-1, 3-glucan, found in the cell walls of gramnegative bacteria and fungi, respectively. The technique involves analysis of environmental samples with the Limulus Amebocyte Lysate (LAL) assay in a handheld device, known as the Lab-On-a-Chip Application Development Portable Test System (LOCAD-PTS). LOCADPTS was launched to the ISS in December 2006, and here we present data obtained from Mach 2007 until the present day. These data include a comparative study between LOCADPTS analysis and existing culture-based methods; and an exploratory survey of surface endotoxin and beta-1, 3-glucan throughout the ISS. While a general correlation between LOCAD-PTS and traditional culture-based methods should not be expected, we will suggest new requirements for microbial monitoring based upon culture-independent parameters measured by LOCAD-PTS.

Gunter, D.↗

LOCAD-PTS: Operation of a New System for Microbial Monitoring Aboard the International Space Station (ISS)

Microorganisms within the space stations Salyut, Mir and the International Space Station (ISS), have traditionally been monitored with culture-based techniques. These techniques involve growing environmental samples (cabin water, air or surfaces) on agar-type media for several days, followed by visualization of resulting colonies; and return of samples to Earth for ground-based analysis. This approach has provided a wealth of useful data and enhanced our understanding of the microbial ecology within space stations. However, the approach is also limited by the following: i) More than 95% microorganisms in the environment cannot grow on conventional growth media; ii) Significant time lags occur between onboard sampling and colony visualization (3-5 days) and ground-based analysis (as long as several months); iii) Colonies are often difficult to visualize due to condensation within contact slide media plates; and iv) Techniques involve growth of potentially harmful microorganisms, which must then be disposed of safely. This report describes the operation of a new culture-independent technique onboard the ISS for rapid analysis (within minutes) of endotoxin and -1, 3-glucan, found in the cell walls of gram-negative bacteria and fungi, respectively. This technique involves analysis of environmental samples with the Limulus Amebocyte Lysate (LAL) assay in a handheld device. This handheld device and sampling system is known as the Lab-On-a-Chip Application Development Portable Test System (LOCAD-PTS). A poster will be presented that describes a comparative study between LOCAD-PTS analysis and existing culture-based methods onboard the ISS; together with an exploratory survey of surface endotoxin throughout the ISS. It is concluded that while a general correlation between LOCAD-PTS and traditional culture-based methods should not necessarily be expected, a combinatorial approach can be adopted where both sets of data are used together to generate a more complete story of the microbial ecology on the ISS.

Maule, J.↗

On-Demand Urine Analyzer

A lab-on-a-chip was developed that is capable of extracting biochemical indicators from urine samples and generating their surface-enhanced Raman spectra (SERS) so that the indicators can be quantified and identified. The development was motivated by the need to monitor and assess the effects of extended weightlessness, which include space motion sickness and loss of bone and muscle mass. The results may lead to developments of effective exercise programs and drug regimes that would maintain astronaut health. The analyzer containing the lab-on-a- chip includes materials to extract 3- methylhistidine (a muscle-loss indicator) and Risedronate (a bone-loss indicator) from the urine sample and detect them at the required concentrations using a Raman analyzer. The lab-on- a-chip has both an extractive material and a SERS-active material. The analyzer could be used to monitor the onset of diseases, such as osteoporosis.

Farquharson, Stuart↗

Digital Microfluidics Sample Analyzer

Three innovations address the needs of the medical world with regard to microfluidic manipulation and testing of physiological samples in ways that can benefit point-of-care needs for patients such as premature infants, for which drawing of blood for continuous tests can be life-threatening in their own right, and for expedited results. A chip with sample injection elements, reservoirs (and waste), droplet formation structures, fluidic pathways, mixing areas, and optical detection sites, was fabricated to test the various components of the microfluidic platform, both individually and in integrated fashion. The droplet control system permits a user to control droplet microactuator system functions, such as droplet operations and detector operations. Also, the programming system allows a user to develop software routines for controlling droplet microactuator system functions, such as droplet operations and detector operations. A chip is incorporated into the system with a controller, a detector, input and output devices, and software. A novel filler fluid formulation is used for the transport of droplets with high protein concentrations. Novel assemblies for detection of photons from an on-chip droplet are present, as well as novel systems for conducting various assays, such as immunoassays and PCR (polymerase chain reaction). The lab-on-a-chip (a.k.a., lab-on-a-printed-circuit board) processes physiological samples and comprises a system for automated, multi-analyte measurements using sub-microliter samples of human serum. The invention also relates to a diagnostic chip and system including the chip that performs many of the routine operations of a central labbased chemistry analyzer, integrating, for example, colorimetric assays (e.g., for proteins), chemiluminescence/fluorescence assays (e.g., for enzymes, electrolytes, and gases), and/or conductometric assays (e.g., for hematocrit on plasma and whole blood) on a single chip platform.

Pollack, Michael G.↗

Carbon Nanotube Based Nanotechnology for NASA Mission Needs and Societal Applications

Carbon nanotubes (CNT) exhibit extraordinary mechanical properties and unique electronic properties and therefore, have received much attention for more than a decade now for a variety of applications ranging from nanoelectronics, composites to meeting needs in energy, environmental and other sectors. In this talk, we focus on some near term potential of CNT applications for both NASA and other Agency/societal needs. The most promising and successful application to date is a nano chem sensor at TRL 6 that uses a 16-256 sensor array in the construction of an electronic nose. Pristine, doped, functionalized and metal-loaded SWCNTs are used as conducting materials to provide chemical variation across the individual elements of the sensor array. This miniaturized sensor has been incorporated in an iPhone for homeland security applications. Gases and vapors relevant to leak detection in crew vehicles, biomedical, mining, chemical threats, industrial spills and others have been demonstrated. SWCNTs also respond to radiation exposure via a change in conductivity and therefore, a similar strategy is being pursued to construct a radiation nose to identify radiation sources (gamma, protons, neutrons, X-ray, etc.) with their energy levels. Carbon nanofibers (CNFs) grown using plasma enhanced CVD typically are vertical, individual, freestanding structures and therefore, are ideal for construction of nanoelectrodes. A nanoelectrode array (NEA) can be the basis for an affinity-based biosensor to meet the needs in applications such as lab-on-a-chip, environmental monitoring, cancer diagnostics, biothreat monitoring, water and food safety and others. A couple of demonstrations including detection of e-coli and ricin will be discussed. The NEA is also useful for implantation in the brain for deep brain stimulation and neuroengineering applications. Miniaturization of payload such as science instrumentation and power sources is critical to reduce launch costs. High current density (greater than 100 mA/per square centimeters) field emission capabilities of CNTs can be exploited for construction of electron gun for electron microscopy and X-ray tubes for spectrometers and baggage screening. A CNT pillar array configuration has been demonstrated, not only meeting the high current density needs but more importantly providing long term emitter stability. Finally, supercapacitors hold the promise to combine the high energy density of a battery with the high power density of capacitors. Traditional graphite electrodes have not delivered this promise yet. A novel design and processing approach using MWCNTs has shown a record 550 F/g capacitance along with significant device endurance. This supercapacitor is suitable for railgun launch application for NASA, powering rovers and robots, consumer electronics and future hybrid vehicles.

Li, Jing↗

NASA Tech Briefs, February 2012

This issue contains the following briefs: (1) Optical Comb from a Whispering Gallery Mode Resonator for Spectroscopy and Astronomy Instruments Calibration (2) Real-Time Flight Envelope Monitoring System (3) Nemesis Autonomous Test System (4) Mirror Metrology Using Nano-Probe Supports (5) Automated Lab-on-a-Chip Electrophoresis System (6) Techniques for Down-Sampling a Measured Surface Height Map for Model Validation (7) Multi-Component, Multi-Point Interferometric Rayleigh/Mie Doppler Velocimeter (8) Frequency to Voltage Converter Analog Front-End Prototype (9) Dust-Tolerant Intelligent Electrical Connection System (10) Gigabit Ethernet Asynchronous Clock Compensation FIFO (11) High-Speed, Multi-Channel Serial ADC LVDS Interface for Xilinx Virtex-5 FPGA (12) Glovebox for GeoLab Subsystem in HDU1-PEM (13) Modified Process Reduces Porosity when Soldering in Reduced Gravity Environments (14) Use of Functionalized Carbon Nanotubes for Covalent Attachment of Nanotubes to Silicon (15) Flexible Plug Repair for Shuttle Wing Leading Edge (16) Three Dimensionally Interlinked, Dense, Solid Form of Single-Walled CNT Ropes (17) Axel Robotic Platform for Crater and Extreme Terrain Exploration (18) Site Tamper and Material Plow Tool - STAMP (19) Magnetic Interface for Segmented Mirror Assembly (20) Transpiration-Cooled Spacecraft-Insulation-Repair Fasteners (21) Fluorescence-Based Sensor for Monitoring Activation of Lunar Dust (22) Aperture Ion Source (23) Virtual Ultrasound Guidance for Inexperienced Operators (24) Model-Based Fault Diagnosis: Performing Root Cause and Impact Analyses in Real Time (25) Interactive Schematic Integration Within the Propellant System Modeling Environment (26) Magnetic and Electric Field Polarizations of Oblique Magnetospheric Chorus Waves (27) Variable Sampling Mapping.

Source record↗

SporeSat

Project Overview: SporeSat is a fundamental space biology science space mission to investigate biophysical mechanisms of plant gravity sensing using a "lab-on-a-chip" experimental approach. The unicellular germinating Ceratopteris richardii fern spore will be studied in outer space. Science Objective: SporeSat shall determine gravity thresholds for calcium ion (Ca2+) channel activation in wild-fern spores. Why This is Important: Ion channels are critical to the functioning of biological organisms, including humans. Ion channels are key components of the nervous system as well as cardiac, skeletal, and smooth muscle function, transport of nutrients and ions, T-cell activation, and pancreatic beta-cell insulin release. Ion channels are often the target of the search for new drugs.

Space Biology↗

Biological CubeSats: What Have We Learned so Far and What Is Next?

Since Apollo 17 in 1972, NASA has sent no humans or other biological organisms outside of Earth's protective magnetosphere. Recently, NASA has set its sights on human exploration in deep space, with an ambitous plan to put astronauts back on the Moon by 2024 and to eventually land human missions on Mars. Such missions will require significant countermeasures, likely both technological and biomedical, to protect biology from chronic radiation exposure. CubeSats can inform these countermeasures by querying relevant space environments with model organisms.NASA has launched five biological CubeSat missions into low-Earth orbit (LEO). GeneSat-1 was launched in 2006 to study gene expression and increase our knowledge of how spaceflight affects microbes. Similar life-support technologies were then used in PharmaSat and O/OREOS, which launched in 2009 and 2010, respectively. PharmaSat contained optical systems to examine how yeast cells responded to an antifungal treatment. One of O/OREOS payloads, SESLO (Space Environment Survivability of Living Organisms), housed dormant microorganisms, which were rehydrated on orbit to track alterations to growth and metabolism induced by microgravity and radiation. In 2014, NASA launched SporeSat to study the mechanisms of plant cell gravity sensing using lab-on-a-chip devices. Most recently, in 2017, NASA launched EcAMSat (E. coli AntiMicrobial Satellite), which investigated the effects of microgravity on antibiotic resistance of a pathogenic bacterium. Each one of these missions increased our understanding of the biological effects of spaceflight in LEO, while refining technologies and imparting valuable lessons to the next generation of CubeSats.CubeSats housing translational biological models are therefore ideal for defining the hazards of deep space travel, as they can provide critical data over relevant durations. BioSentinel, a next-generation deep-space CubeSat, is planned to launch as a secondary payload on Artemis 1 in 2020. BioSentinel will study the DNA damage response to deep space radiation in yeast.

Santa Maria, Sergio R.↗

Measurements of Oxychlorine species on Mars

Mars landed and orbiter missions have instrumentation capable of detecting oxychlorine phases (e.g. perchlorate, chlorate) on the surface. Perchlorate (~0.6 wt%) was first detected by the Wet Chemistry Laboratory in the surface material at the Phoenix Mars Landing site. Subsequent analyses by the Thermal Evolved Gas Analyser aboard the same lander detected an oxygen release (~465°C) consistent with the thermal decomposition of perchlorate. Recent thermal analysis by the Mars Science Laboratory’s Sample Analysis at Mars instrument has also indicated the presence of oxychlorine phases (up to 1.2 wt%) in Gale Crater materials. Despite being at detectable concentrations, the Chemistry and Mineralogy (CheMin) X-ray diffractometer has not detected oxychlorine phases. This suggests that Gale Crater oxychlorine may exist as poorly crystalline phases or that perchlorate/chlorate mixtures exist, so that individual oxychlorine concentrations are below CheMin detection limits (~1 wt%). Although not initially designed to detect oxychlorine phases, reinterpretation of Viking Gas Chromatography/Mass Spectrometer data also suggest that oxychlorine phases are present in the Viking surface materials. Remote near-infrared spectral analyses by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) instrument indicate that at least some martian recurring slope lineae (RSL) have spectral signatures consistent with the presence of hydrated perchlorates or chlorates during the seasons when RSL are most extensive. Despite the thermal emission spectrometer, Thermal Emission Imaging System, Observatoire pour la Minéralogie, l’Eau, les Glaces et l’Activité and CRISM detection of hundreds of anhydrous chloride (~10–25 vol%) deposits, expected associated oxychlorine phases (>5–10 vol%) have not been detected. Total Cl and oxychlorine data sets from the Phoenix Lander and the Mars Science Laboratory missions could be used to develop oxychlorine versus total Cl correlations, which may constrain oxychlorine concentrations at other locations on Mars by using total Cl determined by other missions (e.g. Viking, Pathfinder, MER and Odyssey). Development of microfluidic or ‘lab-on-a-chip’ instrumentation has the potential to be the next generation analytical capability used to identify and quantify individual oxychlorine species on future landed robotic missions to Mars.

Perchlorate↗

Spaceflight Autonomous Multigenerational Microbial Sequencer in Support of Plant-Growth Systems

The CubeSat platform has proven successful in obtaining meaningful life science information when biological payloads are incorporated. Examples include: 1) the first-ever CubeSat with a biological payload, GeneSat-1, which demonstrated decreased growth rates for flight samples of Escherichia coli in low Earth orbit (Parra et al. 2008); 2) PharmaSat, demonstrated that Saccharomyces cerevisiae in the microgravity environment exhibits a significant level of metabolic activity even at high doses of applied antifungal (Ricco et al. 2011); 3) O/OREOS, which used Bacillus subtilis(bacteria) to demonstrate for the first time that microorganisms can be loaded in a dried, dormant form and then rehydrated and grown in orbit months after launch (Nicholson et al. 2011; Ehrenfreund et al. 2014; 4) the SporeSat payload, which investigated Ceratopteris richardii(fern spores) using lab-on-a-chip devices (BioCDs) and minicentrifuges to produce artificial gravitational forces in ground studies (Park et al. 2017), with demonstration of the BioCD and minicentrifuge in space; 5) EcAMSat, the first CubeSat to be directly deployed from the ISS for an experiment assessing antibiotic resistance of E. coli in the microgravity environment (Padgen et al. 2020); 6) BioSentinel, exposed a culture of yeast to galactic cosmic radiation (GCR) and solar particle events while in heliocentric orbit to measure the rate of double-strand-break repair using DNA-repair-deficient mutants. This effort measures the metabolic parameters of yeast in a deep-space environment compared to Earth ambient conditions using a 3-color LED detection system (Ricco et al. 2020; Padgen et al. 2021). We aim to expand this list to include a Spaceflight Autonomous Multigenerational Microbial Sequencer (SAMMS). SAMMS will allow for the genome level understanding of changes in growth and metabolic activity for any organism. While microbes are suitable for early studies in our proposed platform because of their small size, small and relatively less-complicated genomes, fast generation times, and relevance to life support systems; multicellular organisms can similarly be evaluated for their genetic response to the spaceflight environment. The Spaceflight Autonomous Multigenerational Microbial Sequencer (SAMMS) will enable autonomous sequencing of biological samples in plant production units, cislunar orbit and on the lunar surface to examine spaceflight effects (ie. radiation, altered gravity, reduced pressures) on plant and microbial genomes.On this team a Kennedy Space Center (KSC) space crop production and water systems microbiologist/molecular biologist works with a Johnson Space Center (JSC) International Space Station (ISS) microbial sequencing expert and an Ames Research Center (ARC) CubeSat Engineering team to convert an automated Oxford Nanopore librarypreparation and sequencing method to a fluidic CubeSat payload system. The Oxford Nanopore MinION sequencing platform has proven successful in the spaceflight environment onboard the ISS (Stahl-Rommel et al. 2021). Further long-duration spaceflight and exposure to high levels of radiation will cause genotypic effects in biological organisms that may affect their function. Monitoring the adaption of a population to the spaceflight environment and any subsequent beneficial mutations will allow for the harnessing of organisms best suited for use in life support systems. This will ensure that the selected life support-essential microorganisms maintain their intended specified function over generations of culturing in the relevant spaceflight environment without becoming hazardous to crew or spacecraft systems.

Aubrie E Orourke↗

Nano-fabricated size exclusion chromatograph

This poster describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through a microcolumn containing nano-fabricated features will have characteristics elution times that directly correlate to molecular weight.

Nanofluidics microfluidics lab-on-a-chip↗

Nano-fabricated size exclusion chromatograph

This paper describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through amicrocolumn containing nano-fabricated features will have characteristic elution times that directly correlate to molecular weight. Compared to conventional size exclusion chromatography, the nSEC offers greater control over the size exclusion process; mass fabrication; integration of the separation column with associated valves, pumps, and detectors; and dramatic reductions in instrument mass and power requirements.

nanofluids lab-on-a-chip chromatograph separation↗