Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser Micrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Wideband 1.064 micrometer detector evaluation

The performance of several candidate detectors for use as communications detectors in a 400 Mbps 1.064 micrometers laser communication system was evaluated. The results of communication system Bit Error Rate (BER) testing for the best detector of each type are summarized. Complete testing data of each type detector is presented. The 400 Mbps 1.064 micrometers communication system receiver test bed is described. The best communication system results for each detector type are included. Performance comparisons are made at 0.000001 BER, the specification level chosen for satellite laser communication links. The data is presented in two groups. The first indicates the best performance levels that can be expected on normal space laser communication system operation. The second cites the best performance levels which can be achieved by focusing the signal to diffraction limited spots on the photosensitive area.

Green, S. I.↗

Wideband 1.064 micrometer detector evaluation

Several types of communications detectors for use in a 400 Mbps 1.064 micrometer laser communication system were evaluated and characterized. The communication system Bit Error Rate (BER) performance was measured, and test results for the best detector of each type are summarized. The complete BER curves are presented. The 400 Mbps 1.064 micrometer communication system receiver test bed is described. The best performance levels which can be achieved by focusing the signal to diffraction limited spots on the photosensitive area are cited.

Green, S. I.↗

An Injection-seeded Narrow Linewidth Singly Resonant ZGP OPO

Injection seeding of a singly resonant ZnGeP2 (ZGP) mid-infrared optical parametric oscillator (OPO) using a continuous wave 3.39 micrometers laser and a tunable near-infrared laser has been demonstrated. This ZGP OPO utilizes a bow-tie shape cavity with a partially reflective mirror for injection seeding at the signal wavelength. It produces high energy pulses in the mid-IR range from 4-10 micrometers. The injection seeded OPO provides a narrow idler wavelength linewidth of approximately 1 nm, limited by the measurement resolution of the monochromator.

Yu, Jirong↗

Development of mid-infrared solid state lasers for spaceborne lidar

Laser performance of Ho(3+):Tm(3+):Cr(3+):YAG crystals was investigated under both Cr:GSAG laser and flashlamp pumping. A flashlamp pumped Cr:GSAG laser was built to simulate high power quasi-CW laser diode pumping of a 2.1 micrometer holmium laser. The 2.1 micrometer output laser energy exceeded more than 14 mJ, the highest value reported to date under laser pumping near 785 nm. This was obtained in a pulse length of nearly 650 microsec from a 3 x 3 mm Ho:Tm:Cr:YAG rod by using the flashlamp-pumped Cr:CSAG laser as a pumping source at the diode laser wavelength, 785 micrometers. In addition, Ho:Tm:Cr:YAG crystals with various Tm(3+) concentrations were evaluated for flashlamp-pumped normal mode and Q-switched 2.1 micrometer laser operations under a wide variety of experimental conditions in order to understand internal dynamic processes among the ions and to determine an optimum lasing condition. An increase of the laser slope efficiency was observed with the increase of the Tm(3+) concentration from 2.5 to 4.5 atomic percent. The thermal dependence of the laser performance was also investigated. Q-switched laser output energies corresponding to nearly 100 percent of the normal-mode laser energies were obtained in a strong single spike of 200 ns pulse length by optimizing the opening time of a lithium niobate Q-switch.

Whitney, Donald A.↗

Infrared heterodyne radiometer for airborne atmospheric transmittance measurements

An infrared heterodyne radiometer (IHR) was used to measure atmospheric transmittance at selected hydrogen fluoride (2.7 micrometer) and deuterium fluoride (3.8 micrometer) laser transitions. The IHR was installed aboard a KC-135 aircraft for an airborne atmospheric measurements program that used the sun as a backlighting source for the transmission measurements. The critical components are: a wideband indium antimonide (1nSb) photomixer, a CW HF/DF laser L0, a radiometric processor, and a 1900 K blackbody reference source. The measured heterodyne receiver sensitivity (NEP) is 1.3 x 10 to the -19th power W/Hz, which yields a calculated IHR temperature resolution accuracy of delta I sub S/-3 sub S = 0.005 for a source temperature of 1000 K and a total transmittance of 0.5. Measured atmospheric transmittance at several wavelengths and aircraft altitudes from 9.14 km (30,000 ft) to 13.72 km (45,000 ft) were obtained during the measurements program and have been compared with values predicted by the AFGL Atmospheric Line Parameter Compilation.

Wolczok, J. M.↗

Efficient Third Harmonic Generation for Wind Lidar Applications

The characterization of atmospheric winds on a global basis is a key parameter required for accurate weather prediction. The use of a space based lidar system for remote measurement of wind speed would provide detailed and highly accurate data for future weather prediction models. This paper reports the demonstration of efficient third harmonic conversion of a 1 micrometer laser to provide an ultraviolet (UV) source suitable for a wind lidar system based on atmospheric molecular scattering. Although infrared based lidars using aerosol scattering have been demonstrated to provide accurate wind measurement, a UV based system using molecular or Rayleigh scattering will provide accurate global wind measurements, even in those areas of the atmosphere where the aerosol density is too low to yield good infrared backscatter signals. The overall objective of this work is to demonstrate the maturity of the laser technology and its suitability for a near term flight aboard the space shuttle. The laser source is based on diode-pumped solid-state laser technology which has been extensively demonstrated at TRW in a variety of programs and internal development efforts. The pump laser used for the third harmonic demonstration is a breadboard system, designated the Laser for Risk Reduction Experiments (LARRE), which has been operating regularly for over 5 years. The laser technology has been further refined in an engineering model designated as the Compact Advanced Pulsed Solid-State Laser (CAPSSL), in which the laser head was packaged into an 8 x 8 x 18 inch volume with a weight of approximately 61 pounds. The CAPSSL system is a ruggedized configuration suitable for typical military applications. The LARRE and CAPSSL systems are based on Nd:YAG with an output wavelength of 1064 nm. The current work proves the viability of converting the Nd:YAG fundamental to the third harmonic wavelength at 355 nm for use in a direct detection wind lidar based on atmospheric Rayleigh scattering.

Mordaunt, David W.↗

An Automated Optical Fiber Puller for Use in Low-Earth Orbit

With the slowdown in space station construction, limiting astronaut time for scientific experiments, an effort is being made to automate certain experiments. One such experiment is production of heavy metal fluoride fibers in the microgravity environment. Previous work by this author and others have shown that microgravity inhibits crystallization of ZBLAN glass. Thus an automated experiment has been designed. This experiment will consist of several elements, one which includes the use of an autonomous robot to initiate fiber pulling. The first element will be to melt the preform to eliminate crystals. The preform tip will then be heated to the viscosity necessary for fiber drawing. The robot will initiate the draw and attach the fiber end to the take-up reel. Once fiber pulling has commenced, sensors will be used to detect a fiber break, whereupon the robot can re-initiate the pulling process. The fiber will be coated with a polymer and the polymer cured with ultraviolet light. A laser micrometer will be used to monitor fiber diameter. The experiment is designed so that up to 10 preforms can be pulled into fiber during one flight. The apparatus will be mounted on a free-flying carrier which will be placed into low-earth orbit from the cargo bay of the space shuttle by the shuttle robot arm. The experiment can be started by a signal from the shuttle or from the ground via telescience. The experiment will proceed automatically using specially designed algorithms and will be monitored from the ground. The carrier will be picked up by the shuttle before return to earth.

Tucker, Dennis S.↗

Cable and Line Inspection Mechanism

An automated cable and line inspection mechanism visually scans the entire surface of a cable as the mechanism travels along the cable=s length. The mechanism includes a drive system, a video camera, a mirror assembly for providing the camera with a 360 degree view of the cable, and a laser micrometer for measuring the cable=s diameter. The drive system includes an electric motor and a plurality of drive wheels and tension wheels for engaging the cable or line to be inspected, and driving the mechanism along the cable. The mirror assembly includes mirrors that are positioned to project multiple images of the cable on the camera lens, each of which is of a different portion of the cable. A data transceiver and a video transmitter are preferably employed for transmission of video images, data and commands between the mechanism and a remote control station.

Terence J Ross↗

Cable and line inspection mechanism

An automated cable and line inspection mechanism visually scans the entire surface of a cable as the mechanism travels along the cable=s length. The mechanism includes a drive system, a video camera, a mirror assembly for providing the camera with a 360 degree view of the cable, and a laser micrometer for measuring the cable=s diameter. The drive system includes an electric motor and a plurality of drive wheels and tension wheels for engaging the cable or line to be inspected, and driving the mechanism along the cable. The mirror assembly includes mirrors that are positioned to project multiple images of the cable on the camera lens, each of which is of a different portion of the cable. A data transceiver and a video transmitter are preferably employed for transmission of video images, data and commands between the mechanism and a remote control station.

Ross, Terence J.↗

LaRC SmartLab Apps For Instrument Control And Data Processing: Optical Micrometer Data Visualizer

The LaRC Smart Lab applications are a series of software tools to greatly enhance researcher efficiency by streamlining and automating workflows. Python scripts and applications are increasingly being used in scientific workflows, including for instrument control and data processing. Interactive Python scripting environments such as Jupyter Lab provide powerful tools for using Python. In some use cases, the development of standalone applications with dedicated graphical user interfaces (GUIs) can enhance the utility of the code and open it up to more users, including non-programmers. Here, we describe a GUI based optical micrometer data visualization application developed as part of the LaRC SmartLab project. We highlight its use in visualizing experimental data and briefly discuss its implementation to give pointers to programmers who wish develop work based on this application's or similar co de.

LaRC SmartLab↗

Discovery of natural gain amplification in the 10-micrometer carbon dioxide laser bands on Mars - A natural laser

Fully resolved intensity profiles of various lines in the carbon dioxide band at 10.4 micrometers have been measured on Mars with an infrared heterodyne spectrometer. Analysis of the line shapes shows that the Mars atmosphere exhibits positive gain in these lines. The detection of natural optical gain amplification enables identification of these lines as a definite natural laser.

Mumma, M. J.↗

Chemical sensing with pulsed QC-DFB lasers operating at 15.6 micrometers

Pulsed thermoelectrically cooled QC-DFB lasers operating at 15.6 micrometers were characterized for spectroscopic gas sensing applications. A new method for wavelength scanning based on repetition rate modulation was developed. A non-wavelength-selective pyroelectric detector was incorporated in the sensor configuration giving the advantage of room-temperature operation and low cost. Absorption lines of CO2 and H2O were observed in ambient air, providing information about the concentration of these species.

NASA Discipline Life Sciences Technologies↗

Opto-mechanical subsystem of a 10 micrometer wavelength receiver terminal. Waveguide laser local oscillator. Servo system

An engineering model opto-mechanical subsystem for a 10.6-micrometer laser heterodyne receiver is developed, and a CO2 waveguide local oscillator and servo electronics are provided for the receiver. Design goals are presented for the subsystems and overall package design is described. Thermal and mechanical distortion loading tests were performed and the results are included.

Source record↗

2 Micrometers InAsSb Quantum-dot Lasers

InAsSb quantum-dot lasers near 2 micrometers were demonstrated in cw operation at room temperature with a threshold current density of 733 A,/cm(sup 2), output power of 3 mW/facet and a differential quantum efficiency of 13%.

quantum dot↗

Long Wavelength INGaAs/InGaAsP Quantum Well Lasers at [approximately] 2.0 micrometers

InGaAs/InGaAsP strained quantum well buried heterostructure and distributed feedback lasers emitting at wavelengths as long as 2.06 micrometers with low internal loss and threshold currents have been demonstrated for the first time. The room and high temperature characteristics and the threshold gain are discussed.

quantum well lasers indium gallium↗

Development of MBE grown Pb-salt semiconductor lasers for the 8.0 to 15.0 micrometer spectral region

Diodes lasers are fabricated using multiple source molecular beam expitaxial growth of (PbSn)Te on BaF2 substrates. Methods for crystal growth, crystal transfer, and device fabrication by photolithographic techniques were developed. The lasers operate in the spectra range from 10 microns to 14 microns and at temperatures from 12K to 60K continuous wave and to 95 K pulsed.

Miller, M. D.↗