Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser vibrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Material Characterization of Grade 91 Steel Welds using, Micro-resolution Ultrasonic Imaging System

Grade 91 (9Cr-1Mo-V) steel is a common structural material for fossil-fuel fired and nuclear power plants because of its creep strength and oxidation resistance at high temperatures. In this research, we studied the feasibility of correlating the high-resolution images obtained from the immersion ultrasonic imaging technique to microstructure regions in Grade 91 steel plate weldments. The high-resolution ultrasonic images presented in this paper were generated using a 20-MHz focused transducer as the transmitter, and a laser vibrometer as the receiver in the through transmission configuration to produce longitudinal and shear waves. This nondestructive evaluation (NDE) method was used to identify the Fusion Zone (FZ), Heat-Affected Zone (HAZ), and Base Metal (BM) regions of Grade 91 cold metal transfer (CMT) and flux core arc welds (FCAW). The ultrasonic imaging results were analyzed using beam propagation amplitudes and homogeneity, which in turn were used to relate the different microstructure regions of the FCAW and CMT welded samples. With this study, we were able to identify highly susceptible microstructures in the weld that could potentially promote creep type failures.

20 FOSSIL-FUELED POWER PLANTS↗

High-Speed and High-Quality Field Welding Repair Based on Advanced Non-Destructive Evaluation and Numerical Modeling

Creep strength-enhanced ferritic (CSEF) steels such as Grade 91 (9Cr-1Mo-V) and Grade 92 (Fe-9Cr-2W-0.5Mo) steels are widely used in the fossil-fuel-fired and nuclear power plants. The weld integrity of these steels is crucial for power plants' safe and reliable operations. Due to harsh service conditions, the steel weld can become susceptible to environmental degradation. Field welding repair is used to restore the degraded weld’s performance where a controlled temper-bead welding technique is commonly used to temper the freshly formed martensite during welding. However, knowledge of weld repairability is limited and experimental trial and error optimization to achieve desired microstructure and joint properties is expensive and time-consuming. Many existing computational models, e.g., finite element models, are limited to solving heat conduction equation and ignoring convective heat transfer due to molten metal flow. These models can result in over-prediction of peak temperatures of weld pool and heat-affected zone (HAZ), which in turn can affect the accuracy of tempering prediction. Moreover, these finite element models require an input of the deposit profiles in advance and thus limits the usability of these models. Here, a molten pool-based, multi-pass multi-layer model has been developed based on computational fluid dynamics (CFD) approach with the Volume of Fluid (VOF) method. The model calculates the bead formation, thereby eliminating the need for pre-determined bead profiles required by finite element models. For computational efficiency, a coordinate system attached to the moving heat source is utilized. A subroutine is developed to convert the temperature profiles in the reference frame stationary to the heat source to that stationary to the workpiece. The converted thermal cycles are then imported into a microstructure model to compute the tempering kinetics and resultant hardness using a Johnson-Mehl-Avrami-Kolmogorov (JMAK), and modified Grange-Baughman parameter. The modeling approach is first developed and validated on single- and multi-pass deposition of stainless steel filler metal onto a SA-533 high strength steel substrate. The models are then applied to a multi-pass V-groove repair weld of Grade 91 steel plate as well as directed energy deposition of Grade 92 steel. Non-destructive characterization of microstructures was performed on Grade 91 and 92 steel welds. Two welding processes, cold metal transfer (CMT) and flux-cored arc welding (FCAW), were investigated for the Grade 91 steel weld samples. For the Grade 92 weld samples, three different heat inputs (low, medium, and high) of gas tungsten arc welding (GTAW) were utilized to replicate traditional field welding processes. The non-destructive evaluation (NDE) method used for this research was immersion ultrasonic testing (UT) using a micro-resolution ultrasonic imaging methodology specifically designed to operate in the through-transmission configuration operating at 20 MHz of frequency. The system used a focused ultrasonic beam spot size diameter between 250-300 μm, and a 6 μm laser vibrometer spot size for detection, to produce highly defined images with longitudinal and mode-converted shear waves. From the micro-resolution ultrasonic C-scan images, three microstructural regions, i.e., weld metal (WM), HAZ, and base metal (BM), were clearly identifiable. Various levels of ultrasonic amplitudes distributed over the three regions were correlated with electron beam backscattered diffraction (EBSD) images using grain size, grain boundaries, and dislocation densities. The results showed that areas with relatively higher ultrasonic amplitude levels were associated with smaller grains and higher dislocation densities, while areas with lower amplitude levels were associated with larger grains and lower dislocation densities. In addition, ultrasonic velocity data obtained across the three different weld microstructural regions of Grade 91 test samples were correlated with optical metallographic images and hardness measurements. The results showed distinctive decreases in ultrasonic velocity and hardness over the HAZ region, where weld failures often occur during service.

36 MATERIALS SCIENCE↗

Assessment of Weld Microstructure Through Sound Velocity Measurements for Power Plant Applications

Here, this research study employed an immersion-based micro-resolution ultrasonic velocity measurement technique (MUVT) to evaluate Grade 91 (9Cr-1Mo-V) steel welds. This process utilized a 20 MHz focused ultrasonic beam with a spot size of 250 µm, a 6 µm laser vibrometer spot size for detection, and an automated 3-axis raster scanner to accurately collect ultrasonic velocity data from two Grade 91 steel welds fabricated using cold metal transfer (CMT) and flux-cored arc welding (FCAW) processes. By analyzing the MUVT data, the Poisson’s ratio (υ) and modulus of elasticity (E), which are important mechanical properties for weldments, were calculated. The correlation between mechanical properties and ultrasonic velocity was examined. The results indicated that longitudinal ultrasonic velocity could effectively identify base metal, heat-affected zone (HAZ), and weld metal areas, showing a strong correlation with hardness. In particular, the distinctive V-shaped dip in velocity and hardness data across the HAZ areas of both samples highlighted changes in the microstructure of creep strength–enhanced ferritic steel welds. Importantly, the immersion-based MUVT demonstrated high accuracy in small sections of the weld, surpassing the conventional contact ultrasonic testing method in spatial resolution detection.

arc welding↗

Experiments on active control of vibrational power flow using piezoceramic actuators and sensors

The active control of flexural power flow in both semiinfinite and finite elastic beams is experimentally investigated. The experimental results demonstrate that piezoceramic transducers when used in conjunction with an adaptive least mean squares controller, can effectively control flexural power flow in thin beam systems. The piezoceramic transducers offer distinct size and weight advantages over conventional transducers. The experiments also demonstrate the use of an axial scanning laser vibrometer to determine out of plane velocity and power flow.

Gibbs, Gary P.↗

Active isolation of vibrations with adaptive structures

Vibration transmission in structures is controlled by means of a technique which employs distributed arrays of piezoelectric transducers bonded to the supporting structure. Distributed PVDF piezoelectric strips are employed as error sensors, and a two-channel feedforward adaptive LMS algorithm is used for minimizing error signals and thereby controlling the structure. A harmonic force input excites a thick plate, and a receiving plate is configured with three pairs of piezoelectric actuators. Modal analyses are performed to determine the resonant frequencies of the system, and a scanning laser vibrometer is used to study the shape of the response of the receiving plate during excitation with and without the control algorithm. Efficient active isolation of the vibrations is achieved with modal suppression, and good control is noted in the on-resonance cases in which increased numbers of PVDF sensors and piezoelectric actuators are employed.

Guigou, C.↗

Integrated optics for fiber optic sensors

Recent progress achieved in the field of fiber-optic sensor applications is discussed with emphasis placed on LiNbO3-based integrated optics (IO). Particular consideration is given to advanced electromagnetic-field sensors, an integrated laser vibrometer system, and a fiber-optic gyroscope system. It is shown that the multifunction IO chips have enabled high perforamance fiber-optic sensors (e.g., fiber-optic gyros), provided advanced and unique signal processing capabilities and advanced architectures, and have a potential of making fiber-optic sensors at low cost.

Minford, W. J.↗

Acoustic fatigue characterization of carbon/carbon panels

Data from a sonic fatigue test of a blade-stiffened carbon/carbon panel is analyzed to determine the progression of damage to failure. The reduction in stiffness, as observed from acceleration measurements taken during the test, is correlated with the physical damage. Damage was measured through visual inspection, thermographic measurements, and through the novel use of vibration data collected using a scanning laser vibrometer.

Rizzi, S. A.↗

A New Way of Testing Large Thin Membrane, Optical Modal Testing of the 1/10th Scale Model of the NASA NAGT Sunshield

The Next Generation Space Telescope design includes a deployed sunshield to thermally insulate the telescope, keeping vital detector temperatures below 60 degrees Kelvin. The sunshield consists of four struts supporting four thin film membranes. Since it would be very difficult to test the full-scale sunshield on the ground due to its size and the 1-g environment, it is important to have accurate analytical models of the sunshield to analyze its affect on the observatory. A 1/10th-scale model of the sunshield has been manufactured in order to test the analytical modeling techniques used to predict the dynamic behavior of such large, lightweight structures. A modal survey test of the scale model has been performed in a vacuum environment, using a laser vibrometer to measure the mode shapes of the membranes. The presentation describes the setup and test procedures related to these tests and presents some of the experimental results obtained and the lessons learned.

Ross, Brian↗

Comparison of Dynamic Characteristics for an Inflatable Solar Concentrator in Atmospheric and Thermal Vacuum Conditions

Dynamic testing of an inflatable solar concentrator structure in a thermal vacuum chamber as well as in ambient laboratory conditions is described in detail. Unique aspects of modal testing for the extremely lightweight inflatable are identified, including the use of a noncontacting laser vibrometer measurement system. For the thermal vacuum environment, mode shapes and frequency response functions are compared for three different test article inflation pressures at room temperature. Modes that persist through all the inflation pressure regimes are identified, as well as modes that are unique for each pressure. In atmospheric pressure and room temperature conditions, dynamic measurements were obtained for the expected operational inflation pressure of 0.5 psig. Experimental mode shapes and frequency response functions for ambient conditions are described and compared to the 0.5 psig results from the thermal vacuum tests. Only a few mode shapes were identified that occurred in both vacuum and atmospheric environments. This somewhat surprising result is discussed in detail, and attributed at least partly to 1.) large differences in modal damping, and 2.) significant differences in the mass of air contained by the structure, in the two environments. Results of this investigation point out the necessity of testing inflatable space structures in vacuum conditions before they can be launched. Ground testing in atmospheric pressure is not sufficient for predicting on-orbit dynamics of non-rigidized inflatable systems.

Slade, Kara N.↗

Binaural Simulation Experiments in the NASA Langley Structural Acoustics Loads and Transmission Facility

A location and positioning system was developed and implemented in the anechoic chamber of the Structural Acoustics Loads and Transmission (SALT) facility to accurately determine the coordinates of points in three-dimensional space. Transfer functions were measured between a shaker source at two different panel locations and the vibrational response distributed over the panel surface using a scanning laser vibrometer. The binaural simulation test matrix included test runs for several locations of the measuring microphones, various attitudes of the mannequin, two locations of the shaker excitation and three different shaker inputs including pulse, broadband random, and pseudo-random. Transfer functions, auto spectra, and coherence functions were acquired for the pseudo-random excitation. Time histories were acquired for the pulse and broadband random input to the shaker. The tests were repeated with a reflective surface installed. Binary data files were converted to universal format and archived on compact disk.

Grosveld, Ferdinand W.↗

Numerical and Experimental Dynamic Characteristics of Thin-Film Membranes

Presented is a total-Lagrangian displacement-based non-linear finite-element model of thin-film membranes for static and dynamic large-displacement analyses. The membrane theory fully accounts for geometric non-linearities. Fully non-linear static analysis followed by linear modal analysis is performed for an inflated circular cylindrical Kapton membrane tube under different pressures, and for a rectangular membrane under different tension loads at four comers. Finite element results show that shell modes dominate the dynamics of the inflated tube when the inflation pressure is low, and that vibration modes localized along four edges dominate the dynamics of the rectangular membrane. Numerical dynamic characteristics of the two membrane structures were experimentally verified using a Polytec PI PSV-200 scanning laser vibrometer and an EAGLE-500 8-camera motion analysis system.

Young, Leyland G.↗

The Load Capability of Piezoelectric Single Crystal Actuators

Piezoelectric lead magnesium niobate-lead titanate (PMN-PT) single crystal is one of the most promising materials for electromechanical device applications due to its high electrical field induced strain and high electromechanical coupling factor. PMN-PT single crystal-based multilayer stack actuators and multilayer stack-based flextensional actuators have exhibited high stroke and high displacement-voltage ratios. The actuation capabilities of these two actuators were evaluated using a newly developed method based upon a laser vibrometer system under various loading conditions. The measured displacements as a function of mechanical loads at different driving voltages indicate that the displacement response of the actuators is approximately constant under broad ranges of mechanical load. The load capabilities of these PMN-PT single crystal-based actuators and the advantages of the capability for applications will be discussed.

Xu, Tian-Bing↗

Testing of a 10-meter Quadrant Solar Sail

The purpose of this paper is to address the technical challenges and requirements of modal testing a solar sail system (Fig. 1). Specific objectives of this work are to investigate the effectiveness (i.e. accuracy, precision, repeatability, etc.) of laser vibrometer measurements obtained on solar sail components (i.e. sail membrane quadrant and masts) actuated with various excitation methods in vacuum conditions. Results from this work will be used to determine the appropriate test technique for testing large scale full quadrant flight-like solar sail system hardware in vacuum conditions. This paper will focus on the dynamic tests conducted in-vacuum on a 10-meter solar sail quadrant development by AEC-ABLE as part of a ground demonstrator system development program funded by NASA's In-Space Propulsion program. One triangular shaped quadrant of a solar sail membrane (Fig. 2) was modal tested in a 1 Torr vacuum environment using various excitation techniques including, shaker excitation through the masts, magnetic excitation (Ref. 3), and surface-bonded piezoelectric patch actuators (Ref. 4 & 5). The excitation methods are evaluated for their applicability to in-vacuum ground testing and their traceability to the development of on-orbit flight test techniques. The solar sail masts (Fig. 3) were also tested in ambient atmospheric conditions and vacuum using various excitation techniques and these methods will also be assessed for their ground test capabilities and traceability to on-orbit flight testing.

Gaspar, James L.↗

The Load Capability of Piezoelectric Single Crystal Actuators

Piezoelectric lead magnesium niobate-lead titanate (PMN-PT) single crystal is one of the most promising materials for electromechanical device applications due to its high electrical field induced strain and high electromechanical coupling factor. PMN-PT single crystal-based multilayer stack actuators and multilayer stack-based flextensional actuators have exhibited high stroke and high displacement-voltage ratios. The actuation capabilities of these two actuators were evaluated using a newly developed method based upon a laser vibrometer system under various loading conditions. The measured displacements as a function of mechanical loads at different driving voltages indicate that the displacement response of the actuators is approximately constant under broad ranges of mechanical load. The load capabilities of these PMN-PT single crystal-based actuators and the advantages of the capability for applications will be discussed.

Xu, Tian-Bing↗

Vibroacoustic Response Data of Stiffened Panels and Cylinders

NASA has collected vibroacoustic response data on a variety of complex, aerospace structures to support research into numerical modeling of such structures. This data is being made available to the modeling community to promote the development and validation of analysis methods for these types of structures. Existing data from two structures is described, as well as plans for a data set from a third structure. The first structure is a 1.22 m by 1.22 m stiffened aluminum panel, typical of a commercial aircraft sidewall section. The second is an enclosed, stiffened aluminum cylinder, approximately 3.66 m long and 1.22 m in diameter, constructed to resemble a small aircraft fuselage with no windows and a periodic structure. The third structure is a filament-wound composite cylinder with composite stiffeners. Numerous combinations of excitation and response variables were measured on the structures, including: shaker excitation; diffuse acoustic field; velocity response from a laser vibrometer; intensity scans; and point acceleration.

Cabell, Randolph↗

De-Trending Techniques: Methods for Cleaning Questionable Shock Data

Not all zero shifted acceleration data can De-trended using this technique. DC shifts, improper AC coupling, Circuit noise/EMI/EMR, Equivalent RC circuit gain response/Circuit saturation(Slew Rate Limited), fixture grounding and wiring losses can all contribute to bad shock data being recorded. Some data that is zero-shifted or exhibit large instantaneous velocity shifts is inherently bad and a retest is warranted. Clean Acceleration-Time history data can be bad upon examining the Velocity & Displacement profiles. Laser Vibrometers provide a high level of accuracy for pyrotechnic shock testing. Engineering judgment and experience will determine the validity of Shock data.

Grillo, Vincent J.↗

Local Guided Wavefield Analysis for Characterization of Delaminations in Composites

Delaminations in composite laminates resulting from impact events may be accompanied by minimal indication of damage at the surface. As such, inspection techniques are required to ensure defects are within allowable limits. Conventional ultrasonic scanning techniques have been shown to effectively characterize the size and depth of delaminations but require physical contact with the structure. Alternatively, a noncontact scanning laser vibrometer may be used to measure guided wave propagation in the laminate structure. A local Fourier domain analysis method is presented for processing guided wavefield data to estimate spatially-dependent wavenumber values, which can be used to determine delamination depth. The technique is applied to simulated wavefields and results are analyzed to determine limitations of the technique with regards to determining defect size and depth. Finally, experimental wavefield data obtained in quasi-isotropic carbon fiber reinforced polymer (CFRP) laminates with impact damage is analyzed and wavenumber is measured to an accuracy of 8.5% in the region of shallow delaminations. Keywords: Ultrasonic wavefield imaging, Windowed Fourier transforms, Guided waves, Structural health monitoring, Nondestructive evaluation

Rogge, Matthew D.↗

In-process, layer-by-layer non-destructive testing of additive manufactured components using linear and nonlinear vibrational resonance

Provided is an additive manufacturing system capable of performing in-process, layer-by-layer non-destructive testing, the additive manufacturing system including: a plate for producing a part thereon; a transducer attached to the plate and configured to induce vibrations in the part; and a laser vibrometer configured to detect a vibrational response of the part to determine whether defect and/or anisotropy exists within the part.

Remillieux, Marcel↗