Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser-induced plasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fungal elemental profiling unleashed through rapid laser-induced breakdown spectroscopy (LIBS)

Elemental profiling of fungal species as a phenotyping tool is an understudied topic and is typically performed to examine plant tissue or non-biological materials. Traditional analytical techniques such as inductively coupled plasma–optical emission spectroscopy (ICP-OES) and inductively coupled plasma–mass spectrometry (ICP-MS) have been used to identify elemental profiles of fungi; however, these techniques can be cumbersome due to the difficulty of preparing samples. Additionally, the instruments used for these techniques can be expensive to procure and operate. Laser-induced breakdown spectroscopy (LIBS) is an alternative elemental analytical technique—one that is sensitive across the periodic table, easy to use on various sample types, and is cost-effective in both procurement and operation. LIBS has not been used on axenic filamentous fungal isolates grown in substrate media. In this work, as a proof of concept, we used LIBS on two genetically distinct fungal species grown on a nutrient-rich and nutrient-poor substrate media to determine whether robust elemental profiles can be detected and whether differences between the fungal isolates can be identified. This data set contains the raw LIBS spectral data for the summarized results described inRush, et. al. 2024

elemental profiling↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗

Structured light approaches in laser-based plasma diagnostics

There is a growing demand for plasma diagnostics suitable for industrial plasma reactors employed in semiconductor nanofabrication, especially relevant to microelectronics and quantum information systems. Such reactors typically have limited optical access and pose considerable diagnostic challenges, including intense background emission, significant thermal loads, and contamination of optical viewports. In this study, we outline research into structured light techniques (laser beams with tailored spatial, temporal, or phase characteristics) that effectively overcome these issues using laser-induced fluorescence (LIF) as an example. The focus of presented diagnostics is on ion kinetics analysis within an industrial plasma source, although this approach is broadly applicable to other plasma systems and diagnostic contexts. We present a confocal LIF implementation using an axicon-generated Bessel annular beam, achieving spatial resolutions of approximately 5 mm at a focal distance of 300 mm, with potential improvements to about 1 mm. This approach matches conventional orthogonal LIF performance but requires only one optical port. Wavelength-modulation LIF employs nonlinear laser wavelength tuning to measure spectral line derivatives, suppressing background emission and enhancing details of spectral line shape. Additionally, we present new results on applying vortex beams (laser beams carrying orbital angular momentum, OAM) for LIF measurements in an industrial plasma device. These measurements enable simultaneous axial and tangential velocity determination using a single laser beam and have been tested with xenon ion transition. Initial quantification of results was performed. Together, these structured-light approaches provide robust, background-resilient, multi-dimensional diagnostics for complex plasma environments.

Romadanov, Ivan [Princeton Plasma Physics Laborato↗

Interactions of a Microdischarge with a Premixed Flame (Final Technical Report)

In this project we introduced an experimental platform that facilitates the study of the two-way interaction of plasma and flame, and the exploration of the impact of the spatial location of the discharge on its kinetics, in a controlled environment. The experimental platform is a mesoscale CH4/air premixed flame burner that also acts as a dielectric barrier discharge (DBD) operated by nanosecond pulsed voltage. A unique feature of this setup is that the DBD utilizes transparent electrodes, made of Indium Tin Oxide (ITO), to unlock optical access along the line-of-sight parallel to the dominant electric field. This platform is suitable to study both the forward problem (impact of plasma-on-flame), which manifests itself as a modified flame speed as well as flame wrinkling; and the backward problem (impact of flame-on-plasma), which includes plasma regime transitions, between microdischarges and uniform modes, driven by the flame passage. Prior work at MIT has focused on electrical measurements and direct imaging studies of the plasma-flame interaction through the ITO electrode. This project, which was awarded experimental runtime at the Low-temperature Plasma Research Facility (PRF) at Sandia National Laboratories, quantifies the flame-plasma interaction through temporally resolved measurement of key radicals (oxygen atom, O) produced by the nanosecond repetitively pused discharge (NRPD) in an individual microdischarge, using two-photon absorption laser-induced fluorescence (TALIF).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Planar laser-induced fluorescence system for spatiotemporal ion velocity distribution function measurements

In this work, we present a planar laser-induced fluorescence (PLIF) system for measuring two-dimensional (2D), spatiotemporally resolved ion velocity distribution functions (IVDFs). A continuous-wave tunable diode laser produces a laser sheet that irradiates the plasma, and the resulting fluorescence is captured by an intensified CCD (ICCD) camera. Fluorescence images recorded at varying laser wavelengths are converted into 2D IVDFs using the Doppler shift principle. The developed diagnostic is implemented in an electron beam generated E × B plasma with a bulk plasma density of $\sim\!\!{10^{10}}{\text{c}}{{\text{m}}^{ - 3}}$ . The developed diagnostic is validated against a conventional single-point LIF method using photomultiplier tube-based detection, while significantly reducing the total measurement time by the number of spatial positions measured. The time-resolving capability of this diagnostic is tested by oscillating the plasma between two nominal operating modes with different density profiles and triggering the ICCD camera by the externally driven plasma oscillation. The measured 2D IVDF maps reveal several signatures of ion dynamics in this plasma source, including radially outflowing ions across the electric field and anomalous ion heating at the periphery, consistent with recent kinetic simulations and theoretical studies. A possible correlation between these ion kinetic features and rotating spoke structures is discussed.

E×B plasma↗

Enhanced production of active species and NH 3 using non-equilibrium ferroelectric barrier discharge

Non-equilibrium plasma-assisted ammonia synthesis is investigated through enhanced active species production with ferroelectric discharge. Time-resolved in-situ diagnostics of femtosecond two-photon absorption laser-induced fluorescence, coherent anti-Stokes Raman scattering, and laser absorption spectroscopy, as well as optical emission spectroscopy, were conducted to probe the key intermediate species, such as H and N radicals as well as N 2 (ν), ions, and NH 3 to achieve better understanding of non-equilibrium energy transfer and ammonia formation. The results reveal that ferroelectric discharge improved ammonia yield by four times. Results also show that ferroelectrics not only enhanced ions (N 2 + ) production, radicals (N, H) number density, but also increased the N 2 vibrational temperature. Further plasma modeling identified the couplings between elevated radical and ion production and enhanced vibrational excitation reactions, e.g., N + H 2 (ν)→NH + H, N 2 (ν)+H → NNH, N 2 + + H 2 → H + N 2 H + , and N 2 H + +e→NH + N, facilitated by ferroelectric discharge. These findings provide critical insight into the mechanism of ferroelectric plasma catalysis and highlight their potential in advancing energy-efficient chemical synthesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Phase-field approach to cellular blebbing

Bulges in the plasma membrane of cells known as blebs can form spontaneously in a wide range of biological processes, but what controls their shape and stability remains incompletely understood. Here, to address this we introduce a dual phase-field model with coupled order parameters representing the cell cortex and plasma membrane that can quantitatively model blebbing in three dimensions. Simulations and sharp-interface analyses reveal that, depending on whether blebbing occurs by detachment of the plasma membrane or rupture of the actin cortex, blebs can form discontinuously through a saddle-node bifurcation or continuously with increasing cortical tension. The model predictions are in good quantitative agreement with existing experimental data for laser-induced cortex rupture.

Biological and medical sciences↗

Quantitative Analysis of Fission-Product Surrogates in Molten Salt Chloride Aerosols

This work demonstrates laser-induced breakdown spectroscopy (LIBS) applied to a stream of aerosolized salt from molten eutectic LiCl-KCl. We demonstrate analytical capabilities to track fission-product surrogates of Cs, Sr, Pr, and Nd simultaneously, with application to monitor salts in pyroprocessing schemes and molten salt reactors. This work demonstrates limits of detection using LIBS on the order of 100 μg/g, which proves potentially applicable to monitoring fission-product concentrations in pyroprocessing applications. Additionally, this work explores fundamental aspects of plasma temperature and plasma electron density of the aerosolized species during LIBS with a specific focus on potential non-uniform plasma conditions in the aerosol.

74 - ATOMIC AND MOLECULAR PHYSICS↗

Rare Earth Element Detection and Quantification in Coal and Rock Mineral Matrices

As global demand for rare earth elements (REEs) increases, maintaining the production and supply chain is critical. Technologies capable of being used in the field and in situ in the subsurface for rapid REE detection and quantification facilitates the efficient mining of known resources and exploration of new and unconventional resources. Laser-induced breakdown spectroscopy (LIBS) is a promising technique for rapid elemental analysis both in the laboratory and in the field. Multiple articles have been published evaluating LIBS for detection and quantification of REEs; however, REEs in their natural deposits have not been adequately studied. In this work, detection and quantification of two REEs, La and Nd, have been studied in both synthetic and natural mineral matrices at concentrations relevant to REE extraction. Measurements were performed on REE-containing rock and coal samples (natural and synthetic) utilizing different LIBS instruments and techniques, specifically a commercial benchtop instrument, a custom benchtop instrument (single- and double-pulse modes), and a custom LIBS probe currently being developed for in situ, subsurface, borehole wall detection and quantification of REEs. Plasma expansion, emission intensity, detection limits, and double-pulse signal enhancement were studied. The limits of detection (LOD) were found to be 10/14 ppm for La and 15/25 ppm for Nd in simulated coal/rock matrices in single-pulse mode. Signal enhancement of 3.5 to 6-fold was obtained with double-pulse mode as compared to single-pulse operation.

La detection↗

Quantification of trace iodine using laser-induced breakdown spectroscopy for real-time monitoring of nuclear off-gas streams

This study evaluated the potential of laser-induced breakdown spectroscopy (LIBS) for real-time monitoring of trace gas-phase iodine, which is an element of high significance in nuclear applications due to its long radioactive half-life (as iodine-129), volatility, and biological impact. In anticipation of iodine evolving into off-gas systems in molten salt reactor and nuclear fuel recycling applications, this research aimed to assess LIBS performance in flowing argon and helium matrices; optimize measurement parameters using a multichannel spectrometer; and perform calibrations to assess predictive capabilities and limits of detection (LODs). Experimental results successfully measured gas-phase iodine in flowing argon and helium; however, trace iodine was not detected in air. Optimal delay times were determined to be 10 µs for argon and 1 µs for helium, which are consistent with the expected shorter plasma lifetime in helium relative to argon. An emission line survey was provided with the 206.16, 804.37, 902.24, and 905.83 nm peaks, which were identified as the strongest emission peaks. Calibration models were successfully built in both helium and argon, achieving LODs down to 3 ppm in helium and 5 ppm in argon. The iodine emission at 905.83 nm emerged as the most robust for calibration and was subsequently applied to a time series dataset in argon. The predictive trace confirmed the feasibility of employing LIBS for continuous, online quantification of trace iodine in flowing gas systems.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Detection limits for laser absorption spectroscopy of Li in laser ablation plumes

A high-sensitivity laser absorption spectroscopy (LAS) method is demonstrated for rapid and non-contact analysis of Li in solids. Glass samples with Li concentrations ranging from 1-500 ppm by mass are ablated in 5 Torr air, and time-resolved Li atomic absorption is measured using a tunable laser near 671 nm. Significant improvements in analytical performance over prior laser-induced breakdown techniques are demonstrated. Here, a single-shot limit of detection (LOD) of 180 ppb is shown for fixed wavelength operation, improving to 6 ppb with averaging over 1000 ablation shots (100 s acquisition time). Isotope-resolved Li absorption spectra are measured with a 17 ppb LOD in 40 s. Methods for optimizing LOD based on noise/averaging properties of LAS experiments in LA plumes are discussed.

(020.3260) Isotope shifts↗

Design of a Molten Salt Flow Cell for Combined Absorbance and Laser-Induced Breakdown Spectroscopy for Online Measurements

A novel flow cell allowing for multiple optical spectroscopy measurements on flowing molten salts was designed, and demonstrative calibrations of impurities in aqueous samples were performed. Online compositional measurements of molten salts are of high interest to monitor the state of relevant solar and nuclear systems. Here, the Spectroscopic Configuration for Optical Real-Time Characterization of High-Temperature (SCORCH) fluids cell was designed to meet this need by providing optical access to a high-temperature molten salt sample stream without physical contact between the sample and window materials. Laser-induced breakdown spectroscopy (LIBS) was utilized to quantify Li, Cr, Fe, Ni, Sr, and Pr at concentrations ranging nominally from 0 to 315 mmol L −1 . Laser power, frequency, and plasma position were optimized to mitigate challenges associated with sample splashing. Univariate calibration models were built with R 2 > 0.98, percent root mean square error of cross-validation (%RMSECV) as low as 2.7%, and limits of quantification (LOQs) down to 4.1 mmol L −1 . Simultaneously, absorbance calibrations were developed for the applicable analytes (Cr, Ni, and Pr) using Beer’s law with a pathlength of 4.41 ± 0.10 mm. These models provide excellent quantification performance with R 2 > 0.999, %RMSECV as low as 0.6%, and LODs down to 0.08 mmol L −1 . Although these calibrations were performed for each spectroscopic technique separately, the two methods may be combined in the future through multivariate modeling and sensor fusion to provide more robust models with the benefits of both techniques (e.g., absorbance: oxidation state concentrations, LIBS: elemental concentration). Additionally, optimized spectrometers may be deployed to enhance sensitivity.

absorbance spectroscopy↗

Innovative laser-based methods for monitoring fuel retention in ITER

This paper addresses the challenge of tritium inventory management in ITER and future fusion reactors, highlighting the importance of accurate tritium measurement and its spatial distribution within the vacuum vessel. Given ITER’s operational constraints, especially the limit on tritium retention, precise measurement is essential for both safety and regulatory compliance. To tackle these questions, the paper presents the T-monitor diagnostic system developed by Forschungszentrum Jülich, which uses Laser-Induced Desorption (LID) in combination with Diagnostic Residual Gas Analysis (DRGA) to measure hydrogen isotope concentrations on the surface of divertor tiles. The system integrates a high-power laser, advanced optical components, and a Fast Scanning Mirror Unit (FSMU) for accurate laser spot positioning with rapid response. Designed to measure in situ tritium retention, the diagnostic provides high-resolution spatial mapping, vital for evaluating detritiation strategies. The laser heating process increases the divertor surface temperature to 1600 K within the laser spot, promoting hydrogen isotope desorption. Accurate measurements require the precise control of laser parameters, including pulse duration and spot size, with a target relative accuracy of 20%. The optical design includes both in-vessel and ex-vessel components, such as durable high-reflectivity mirrors made of gold and copper, selected not only for their infrared performance but also for their transmission of visible wavelengths for observation purposes. To protect optical components from contamination, a pneumatic shutter is used.

Hydrogen isotopes↗

Imaging solvated oxygen atoms with a femtosecond laser

As a powerful oxidant, atomic oxygen (O) holds considerable promise for a variety of biomedical and industrial applications. However, the inability to quantify solvated oxygen atoms has prevented the determination of the fundamental parameters governing its behaviour in relevant aqueous environments. Here, we directly image ground-state oxygen atoms in water using femtosecond two-photon absorption laser-induced fluorescence. Measurements show that oxygen atoms persist for tens of microseconds in water, penetrating hundreds of micrometres into the liquid. This observed longevity has significant implications, suggesting a need to re-evaluate existing models of solvated atomic oxygen reactivity and transport. Beyond atomic oxygen, this technique is broadly applicable to other solvated atomic species of interest, including nitrogen (N) and hydrogen (H). This work establishes that radical atomic species can be quantified in liquid with ultrafast laser spectroscopy, providing the basis for the determination of key properties including reaction rates, chemical lifetimes, and Henry’s law constants.

Fluorescence spectroscopy↗

Elemental analysis of air-sensitive frozen molten salt samples using an inert transfer chamber for LIBS/LA-ICP-TOF-MS analysis

A novel inert sample transfer system was developed and employed to enable, for the first time, the analysis of air-sensitive salt samples in a two-volume ablation cell using simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA)-inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) analysis. Molten salts are of growing interest as a medium for advanced nuclear reactors and nuclear fuel reprocessing technologies continue to be developed around their use. However, compositional analysis of molten salt samples can be challenging because of their air-sensitive nature and varying solubilities leading to inaccurate measurements when digested. LA-based analysis provides an alternate method to digestion and can provide rapid elemental information with little sample preparation. In this study, LIBS and LA-ICP-TOF-MS were used to analyze the Ce content in frozen salt samples taken from a series of electrochemical experiments. Calibrations were built for each technique, and the resulting limits of detection for Ce were estimated to be 107 and 58 µg g −1 for LIBS and LA-ICP-TOF-MS, respectively. Test samples from the electrochemical experiments were analyzed using these calibrations. The results matched bulk digestion-based ICP-optical emission spectroscopy values, and daily trends in Ce concentration changes were identified. Additionally, the LIBS and LA-ICP-TOF-MS analysis was demonstrated for identifying microgram per gram levels of components and detecting trace contaminants. The impurities detected by LIBS included Al, Mg, Ca, and Na. The impurities detected by LA-ICP-TOF-MS included W, Ag, Al, Fe, Ni, Mo, Nd, Sm, Th, and U.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Exploration of a Combined LIBS and LA-ICP-MS Approach for Apatite Characterisation

A combined laser‐induced breakdown spectroscopy (LIBS) and laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) method is demonstrated for comprehensive apatite analysis. These measurements provide elemental imaging that can be used as a screening technique for chemical selection of grains for subsequent analysis (e.g., U‐Pb geochronology) or can be used to understand elemental distributions within a single grain that would have direct textural‐chemical implications (e.g., zoning patterns). Adding LIBS as a simultaneous measurement, to LA‐ICP‐MS U‐Pb geochronology, allowed for the direct determination of F (H and O show promise for future applications) in addition to major and trace elements of interest. Here, the quantitative measurements were validated against a series of apatites with known values and used to characterise a wide range of samples. Fluorine detection limits were determined to be as low as 70 μg g ‐1 F (broadband CMOS detector) and 4.2 μg g ‐1 F (ICCD detector). U‐Pb age dating was simultaneously collected by LA‐ICP‐MS with the quantitative elemental data from LIBS, providing a comprehensive method for geochronology.

Apatite↗