Search NASA⌕ Search

SEARCH · Search NASA

Results for “Lasers and Masers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Progress and Plans for a US Laser System for the LISA Mission

NASA Goddard Space Flight Center is developing a master oscillator power amplifier (MOPA) laser transmitter for the ESA-led Laser Interferometer Space Antenna (LISA) mission. Taking advantage of our space laser experience and the emerging telecom laser technology, we are developing a full laser system for the LISA mission. Our research effort has included both master oscillator (MO) and power amplifier (PA) developments, and their environmental testing and reliability for space flight. Our current baseline for the MO is a low-mass, compact micro NPRO (m-NPRO) laser. The amplifier uses a robust mechanical design based on fiber components. We have performed laser system noise tests by amplitude- and frequency-stabilizing the PA output. We will describe our progress and plans to demonstrate a TRL 6 laser system, which is an essential step toward qualifying lasers for space applications, by 2021.

lasers↗

Remote Detection Sodium Cell Magnetometry Using Amplitude Modulated Light

We have investigated the performance of a remote-detection sodium cell magnetometer using synchronous optical pumping with amplitude modulated light. The magnetometer is used to measure ambient geomagnetic field with high-sensitivity using backscattered resonance fluorescence.

Line shapes and shifts and Spectroscopy↗

Fiber-Based Laser MOPA Transmitter Packaging for Space Environment

NASA’s Goddard Space Flight Center has been developing lidar to remotely measure CO2 and CH4 in the Earth’s atmosphere. The ultimate goal is to make space-based satellite measurements with global coverage. We are working on maturing the technology readiness of a fiber-based, 1.57-micron wavelength laser transmitter designed for use in atmospheric CO2 remote-sensing. To this end, we are building a ruggedized prototype to demonstrate the required power and performance and survive the required environment. We are building a fiber-based master oscillator power amplifier (MOPA) laser transmitter architecture. The laser is a wavelength-locked, single frequency, externally modulated DBR operating at 1.57-micron followed by erbium-doped fiber amplifiers. The last amplifier stage is a polarization-maintaining, very-large-mode-area fiber with ~1000 μm2 effective area pumped by a Raman fiber laser. The optical output is single-frequency, one microsecond pulses with >450 μJ pulse energy, 7.5 KHz repetition rate, single spatial mode, and > 20 dB polarization extinction.

Lasers and Masers↗

Classical laser.

In this paper a completely classical model for laser action is discussed. An active medium consisting of classical anharmonic oscillators interacts with a classical electromagnetic field in a resonant cavity. Comparison with the case of a medium consisting of harmonic oscillators shows the significance of nonlinearities for producing self-sustained oscillations in the radiation field. The results for the classical model are found to be similar to those for a semiclassical model of the ammonia-beam maser. The conclusion is that laser action is not intrinsically a quantum-mechanical effect. The classical-laser theory as given in this paper can also be applied to the case of the electron-cyclotron maser.

Borenstein, M.↗

Satellite test of the isotropy of the one-way spe ed of light using ExTRAS

A test of the second postulate of special relativity, the universality of the speed of light, using the ExTRAS (Experiment on Timing Ranging and Atmospheric Sounding) payload to be flown on board a Russian Meteor-3M satellite (launch date January 1997) is proposed. The propagation time of a light signal transmitted from one point to another without reflection would be measured directly by comparing the phases of two hydrogen maser clocks, one on board and one on the ground, using laser or microwave time transfer systems. An estimated uncertainty budget of the proposed measurements is given, resulting in an expected sensitivity of the experiment of delta c/c is less than 8xl0(exp -10) which would be an improvement by a factor of approximately 430 over previous direct measurements and by a factor of approximately 4 over the best indirect measurement. The proposed test would require no equipment additional to what is already planned and so is of inherently low-cost. It could be carried out by anyone having access to a laser or microwave ground station and a hydrogen maser.

Wolf, Peter↗

Far infrared maser communications technology

An optically pumped FIR laser was constructed and tested. Optimum operating conditions were determined with CH3OH as the lasing medium. The laser was found to operate equally well with flowing gas or in a sealed off configuration. The FIR cavity stability and pump laser stability were found to have significant problems. The absorption coefficient per unit pressure of 1-1 difluoroethylene at the P(22) and P(24) lines of the 10.4 micron CO2 band was measured. The FIR line pumped by P(22) occurs at approximately 890 microns, which may be in an atmospheric transmission window. It was found that significant Stark tuning of absorption lines of methanol and 1-1 difluoroethylene can be accomplished, even at the usual 100 to 300 mTorr operating pressures of FIR lasers. This means that the use of Stark tuning may enable more effective use of pump laser output.

Claspy, P. C.↗

A free-electron laser in a uniform magnetic field

The study shows that a free-electron laser can operate in a uniform, longitudinal magnetic field. The fully relativistic Lorentz force equations are examined and solved order by order in a radiation field strength to obtain analytic expressions for the electron trajectory and energy as functions of initial electron position within a wavelength of light. Analytic expressions for the longitudinal and transverse bunching and for laser gain are found. The bunching of this laser process is compared to the bunching processes involved in (1) a Stanford free-electron laser and (2) a cyclotron maser. The results received can be useful in exploring light amplification in astrophysical magnetic fields, the magnetosphere, and in laboratory devices.

Ride, S. K.↗

Shuttle time and frequency transfer experiment

A proposed space shuttle experiment to demonstrate techniques for global high precision comparison of clocks and primary frequency standards is described. The experiment, using transmitted microwave and pulsed laser signals, compared a hydrogen maser clock onboard the space shuttle with a clock in a ground station in order to demonstrate time transfer with accuracies of 1 nsec or better and frequency comparison at the 10 to the -14th power accuracy level.

Allan, D. W.↗

Satellite Time- and Frequency-Transfer System

Time synchronized at distant points within nanosecond. Report describes satellite-borne time-and frequency-transfer system proposed for synchronization of clocks at stations around Earth. Orbiting hydrogen-maser clock and frequency standard communicate by microwave links with Earth stations using hydrogen masers as local clocks. Pulsed-laser time-transfer sub-system also operated concurrently, either synchronized or unsynchronized with microwave subsystems.

Vessot, R. F. C.↗

High Precision Time Transfer in Space with a Hydrogen Maser on MIR

An atomic hydrogen maser clock system designed for long term operation in space will be installed on the Russian space station Mir, in late 1997. The H-maser's frequency stability will be measured using pulsed laser time transfer techniques. Daily time comparisons made with a precision of better than 100 picoseconds will allow an assessment of the long term stability of the space maser at a level on the order of 1 part in 10(sup 15) or better. Laser pulse arrival times at the spacecraft will be recorded with a resolution of 10 picoseconds relative to the space clock's time scale. Cube corner reflectors will reflect the pulses back to the Earth laser station to determine the propagation delay and enable comparison with the Earth-based time scale. Data for relativistic and gravitational frequency corrections will be obtained from a Global Positioning System (GPS) receiver.

Mattison, Edward M.↗

Quantum theory of an optical maser. VI - Transient behavior.

The transient behavior of a laser is discussed using the quantum theory as did Scully and Lamb. The formal solution of the density-matrix equation is expressed in terms of exponentially decaying eigenmodes. Some of the lower decay constants are obtained numerically. The equations for the moments of the density matrix are then derived and solved by a truncation method. The equations of motion are integrated numerically for the case where the average number of photons in a laser cavity has the realistically large value 1.3 x 100,000. An alternative Fokker-Planck-equation approach is discussed.

Wang, Y. K.↗

A highly stable crystal oscillator applied to geodetic VLBI experiment

Instead of a hydrogen maser, a carefully selected Crystal oscillator which is phase locked to a Cesium (Cs) frequency standard of a geodetic VLBI experiment. The domestic VLBI experiment with 55 km baseline using the Crystal oscillator at one end was made in Japan and the obtained error of the baseline vector components were 4 cm, and that of the baseline length was 3 cm. This system may be operated after only 2 hours warm up. These results coincides with those of conventional geodetic Laser ranging and VLBI using a hydrogen maser within the formal error. A VLBI experiment with over 1000 km baselines were carried out successfully from October 1988, and over 11000 km baseline between Japan and Antarctica was carried out successfully in January 1990.

Kiuchi, Hitoshi↗

Far-Infrared Hydrogen Lasers in the Peculiar Star MWC 349A

Far-infrared hydrogen recombination lines H15(alpha)(169.4 micrometers), H12(alpha)(88.8 micrometers), and H10(alpha)(52.5 micrometers) were detected in the peculiar luminous star MWC 349A from the Kuiper Airborne Observatory. Here it is shown that at least H15(alpha) is strongly amplified, with the probable amplification factor being greater than or about equal to 10(exp 3) and a brightness temperature that is greater than or about equal to 10(exp 7) kelvin. The other two lines also show signs of amplification, although to a lesser degree. Beyond H10(alpha) the amplification apparently vanishes. The newly detected amplified lines fall into the laser wavelength domain. These lasers, as well as the previously detected hydrogen masers may originate in the photoionized circumstellar disk of MWC 349A and constrain the disk's physics and structure.

Strelnitski, Vladimir↗

Semiconductor laser amplifier.

IR GaAs laser amplifier with gains as high as 2000, output powers of 150 mw and saturation occurring with current increase at low light levels

POWER GAIN↗