Search NASA⌕ Search

SEARCH · Search NASA

Results for “Latex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Molten salt pyrolysis of latex

Latex-rich plants such as Guayule or extracts thereof are pyrolyzed in an inert nitrogen atmosphere inorganic salt melts such as a LiCl/KCl eutectic at a temperature of about 500 C. The yield is over 60% of a highly aromatic, combustible hydrocarbon oil suitable for use as a synthetic liquid fuel.

Bauman, A. J.↗

Preparation of large-particle-size monodisperse polystyrene latexes in microgravity

Three large-particle-size monodisperse latexes (3.44, 4.08, and 4.98 micron diameter) were prepared in an automated four-reactor apparatus on the third orbital mission of the 'Columbia' begun on March 22. Comparison with ground-based controls showed that the 4.98 micron-size flight sample was the more uniform; the uniformity at the other two sizes was about the same. The rates of polymerization in microgravity and on earth were the same within experimental error, demonstrating that radical-initiated vinyl addition polymerizations are unaffected by the weightless environment.

Vanderhoff, J. W.↗

Evaluation of the Separability of Monodisperse Polystyrene Latex Microspheres in a Continuous Flow Electrophoresis System

The continuous flow electrophoresis system makes electrophoresis possible in a free flowing film of aqueous electrolyte medium. The sample is introduced at one end of the chamber and is subjected to a lateral dc field. This process separates the sample into fractions since each component has a distinctive electrophoric mobility. Evaluations were made of sample conductivity and buffer conductivity as they affect sample band spread and separation using the Continuous Particle Electrophoresis (CPE) system. Samples were prepared from mixtures of 5 percent and 1 percent polystyrene latex (PSL) microspheres which were .4, .56 and .7 microns in diameter. These were prepared in electrolyte media 1x and 3x the conductivity of the curtain buffer, approximately 150 and 450 micro mhos/cm. Samples with matched conductivities produced greater resolution and less band spread than those with 3x the conductivity of the curtain buffer.

Williams, G., Jr.↗

Preparation of large-particle-size monodisperse latexes in space - Polymerization kinetics and process development

Monodisperse polystyrene latexes are prepared by seeded emulsion polymerization; however, sizes larger than 2 microns are difficult to prepare because of the creaming and settling of the particles and their sensitivity to mechanical shear. Preparation in space would obviate the creaming and settling, and allow agitation just sufficient for good heat transfer and mixing. Three polymerizations yielding 3-5 micron size particles were carried out successfully on the third flight of the 'Columbia' launched Mar. 22, 1982; however, four polymerizations yielding sizes up to 10 microns on the fourth flight launched June 27, 1982 were incomplete owing to apparatus malfunction. The results of these polymerizations and the prospects of developing a preparative space process are reviewed.

Vanderhoff, J. W.↗

The formation of small scale granularities in latex particles

A series of latices were synthesized using emulsifier-free emulsion copolymerization of styrene and sodium styrene sulfonic acid. The final latex particles display an internal granular structure which can be ascribed to the primary particles present in the early stages of particle growth. In these systems, the primary particles appear to have maintained their integrity during the swelling and growth stage.

Zukoski, C. F.↗

Rotary Reactor Makes Large Latex Particles

Machine reduces gravitational effects interfering with particle growth. Reaction chamber rotates while polymerization of latex proceeds. Motor turns stirrer. Chamber made of stainless steel with glass windows.

Kornfeld, Dale M.↗

Enhancement of polyisoprene latex production

Production of high molecular weight polyisoprene latex is enhanced by administering to plants, particularly Guayule Plants, an amine containing at least one two-carbon chain substituent and preferably substituted trialkylamine of the general structure: ##STR1## where R.sub.4, R.sub.5 and R.sub.6 are alkyl, preferably ethyl and at least one of R.sub.4, R.sub.5 and R.sub.6 is preferably an electron withdrawing group substituted aryloxy or arylthio ethyl group.

Bauman, Albert J.↗

Heterogeneous chemical reactions: Preparation of monodisperse latexes

It is demonstrated that a photoinitiated emulsion polymerization can be carried out to a significant conversion in a SPAR rocket prototype polymerization vessel within the six minutes allowed for the experiment. The percentage of conversion was determined by both dilatometry and gravimetric methods with good agreement. The experimental results lead to the following conclusions: (1) emulsion polymerizations can be carried out to conversions as high as 75%, using a stable micellized styrene-SLS system plus photoinitiator; (2) dilatometry can be used to accurately determine both the rate and conversion of polymerization; (3) thermal expansion due to the light source and heat of reaction is small and can be corrected for if necessary; (4) although seeded emulsion polymerizations are unfavorable in photoinitiation, as opposed to chemical initiation, polymerizations can be carried out to at least 15% conversion using 7940A seed particles, with 0.05% solids; and (5) photoinitiation should be used to initiate polymerization in the SPAR rocket experiments because of the mechanical simplicity of the experiment.

Vanderhoff, J. W.↗

Retractor Tool for Brain Surgery

Proposed brain-surgery tool has an octogonal fixture for positioning latex tube over incision. Eight stainless-steel wires embedded in latex extend to hold positioning fixture. Another eight are also embedded in the latex. Concentric sleeves are successively inserted into expandable latex tube. The first sleeve is placed over a solid rod. Last sleeve is a stainless-steel tube 1 inch in diameter. It is overcoated with Teflon (or equivalent) material.

Helms, R.↗

Development of a special purpose spacecraft interior coating, phase 1

Coating formulations were developed consisting of latex blends of fluorocarbon polymers, acrylic resins, stabilizers, modifiers, other additives, and a variety of inorganic pigments. Suitable latex primers were also developed from an acrylic latex base. The formulations dried to touch in about one hour and were fully dry in about twenty-four hours under normal room temperature and humidity conditions. The resulting coatings displayed good optical and mechanical properties, including excellent bonding to (pre-treated) substrates. In addition, the preferred compositions were found to be self-extinguishing when applied to nonflammable substrates and could meet the offgassing requirements specified by NASA for the intended application. Improvements are needed in abrasion resistance and hardness.

Bartoszek, E. J.↗

Fast-drying coating

Nontoxic coating has excellent optical properties and can be pigmented in many different colors. It bonds well, can be applied by conventional methods, weathers well, and is self-extinguishing. Coating composition comprises latex blends of fluorocarbons, acrylic resins, stabilizers, modifiers, variety of inorganic pigments, and other additives. Suitable latex primers have also been developed from acrylic latex base.

Bartoszek, E. J.↗

Electrokinetic properties of polymer colloids

The surface of polymer colloids, especially polystyrene latexes, were modified for the purpose of controlling the electrokinetic properties of the resulting colloids. Achievement required a knowledge of electrical double layer charging mechanism, as a function of the electrolyte conditions, at the polymer/water interface. The experimental approach is to control the recipe formulation in the emulsion polymerization process so as to systematically vary the strong acid group concentration on the surface of the polymer particles. The electrophoretic mobility of these model particles will then be measured as a function of surface group concentration and as a function of electrolyte concentration and type. An effort was also made to evaluate the electrophoretic mobility of polystyrene latexes made in space and to compare the results with latexes made on the ground.

Micale, F. J.↗

Contamination of Critical Surfaces from NVR Glove Residues Via Dry Handling and Solvent Cleaning

Gloves are often used to prevent the contamination of critical surfaces during handling. The type of glove chosen for use should be the glove that produces the least amount of non-volatile residue (NVR). This paper covers the analysis of polyethylene, nitrile, latex, vinyl, and polyurethane gloves using the contact transfer and gravimetric determination methods covered in the NASA GSFC work instruction Gravimetric Determination and Contact Transfer of Non-volatile Residue (NVR) in Cleanroom Glove Samples, 541-WI-5330.1.21 and in the ASTM Standard E-1731M-95, Standard Test Method for Gravimetric Determination of Non-Volatile Residue from Cleanroom Gloves. The tests performed focus on contamination of critical surfaces at the molecular level. The study found that for the most part, all of the gloves performed equally well in the contact transfer testing. However, the polyethylene gloves performed the best in the gravimetric determination testing, and therefore should be used whenever solvent contact is a possibility. The nitrile gloves may be used as a substitute for latex gloves when latex sensitivity is an issue. The use of vinyl gloves should be avoided, especially if solvent contact is a possibility. A glove database will be established by Goddard Space Flight Center (GSFC) Code 541 to compile the results from future testing of new gloves and different glove lots.

Sovinski, Marjorie F.↗

Electrophoresis demonstration on Apollo 16

Free fluid electrophoresis, a process used to separate particulate species according to surface charge, size, or shape was suggested as a promising technique to utilize the near zero gravity condition of space. Fluid electrophoresis on earth is disturbed by gravity-induced thermal convection and sedimentation. An apparatus was developed to demonstrate the principle and possible problems of electrophoresis on Apollo 14 and the separation boundary between red and blue dye was photographed in space. The basic operating elements of the Apollo 14 unit were used for a second flight demonstration on Apollo 16. Polystyrene latex particles of two different sizes were used to simulate the electrophoresis of large biological particles. The particle bands in space were extremely stable compared to ground operation because convection in the fluid was negligible. Electrophoresis of the polystyrene latex particle groups according to size was accomplished although electro-osmosis in the flight apparatus prevented the clear separation of two particle bands.

Snyder, R. S.↗

Development of a special purpose spacecraft interior coating. Phase 2

Numerous acrylic and epoxy modifiers for the fluorocarbon latex resin base were investigated. Optimum coatings were developed by modifying the fluorocarbon latex with an epoxy acrylic resin system. In addition, a number of other formulations, containing hard acrylics as modifiers, displayed attractive properties and potential for further improvements. The preferred formulations dried to touch in about one hour and were fully dried in about twenty four hours under normal room temperature and humidity conditions. In addition to physical and mechanical properties either comparable or superior to those of commercial solvent base polyurethane or polyester coatings, the preferred compositions meet the flammability and offgassing requirements specified by NASA.

Bartoszek, E. J.↗

Development of stable low-electroosmotic mobility coatings

Long-time rinsings of the Z6040-methlycellulose coating used successfully on the ASTP MA=011 experiment indicate the permanency of this coating is inadequate for continuous flowing systems. Two approaches are described for developing coatings which are stable under continuous fluid movement and which exhibit finite and predictable electroosmotic mobility values while being effective on different types of surfaces, such as glass, plastics, and ceramic alumina, such as is currently used as the electrophoresis channel in the GE-SPAR-CPE apparatus. The surface charge modification of polystyrene latex, especially by protein absorption, to be used as model materials for ground-based electrophoresis experiments, and the preliminary work directed towards the seeded polymerization of large-particle-size monodisperse latexes in a microgravity environment are discussed.

Vanderhoff, J. W.↗