At least 37 records · Page 2

Evaluation of a 5kW Solid Oxide Electrolysis Cell Stack

Solid oxide electrolysis cells (SOECs) are a developing technology for hydrogen production. They are promising due to their utilization of thermal energy to reduce their electricity consumption. The Department of Energy (DOE) has set goals to reduce the price per kilogram of hydrogen, and Idaho National Laboratory (INL) is conducting research to develop and demonstrate advanced methods and technologies to achieve making hydrogen a more affordable, efficient, and sustainable energy source. In this project, INL is collaborating with a vendor to evaluate and validate the design of a 5kW SOEC stack. The test aims to demonstrate a safe startup, operation, and shutdown on INL’s 5kW test stand, providing third-party validation in a different environment. A successful 50-hour test with stable hydrogen production will pave the way for a subsequent 1000-hour test. This project emphasized learning about electrolysis and the various support systems, referred to as balance of plant (BOP) equipment. These systems required modification while swapping to the vendor 5kW SOEC stack, most prominently the furnace door design and the controls system. It also included gaining skills in creating computer-aided design (CAD) drawings for the new door while using available materials and ensuring it met high-temperature requirements. Upon completion of modifications to the test stand, the SOEC will be test-fitted with respective wiring and piping. Instrumentation and piping will be checked for leaks and quality. This must be completed before the vendor’s engineers arrive to observe the test plan, startup, and a collection of 50 hours of data. The vendor’s engineers will ensure their stack performed sufficiently in the 50-hour test to enable the progression to a 1000-hour test.

08 - HYDROGEN

Lifetime extension drop-test of real-world corroded 5 Quart Hagan nuclear material storage container

A 5Qt Hagan container with a 20-year history of nuclear material storage was challenged with three successive drop tests at a height of 3.7 meters. The total mass of the test package was 12.1 kg. The 1st and 2nd drop tests (center of gravity over the container bottom corner but 180 degrees apart on the container bottom face) passed the pre- and post- impact helium leak criterion at less than 1.00E-6 atm-cc/sec (ambient cubic centimeters per second). The 3rd and final test (center of gravity over top corner) failed with a post-impact gross leak of 1.1E-1 atmcc/sec. The RRFMC (Respirable Release Fraction Measurement Chamber) is a drop tower test system that is critical for the sustainability of the SAVY-4000™ series and Hagan-type (NFT Inc. Golden CO) nuclear material storage containers. These are the primary in-use nuclear material storage container types at the Los Alamos National Laboratory TA-55 facility. Results are presented to expand the technical knowledge basis for container lifetime, regarding actual exposure to corrosive gas species on the container inner surfaces. The primary source of general corrosion throughout the container is gaseous hydrogen chloride (HCl). This gas is generated by the degradation of the polyvinylchloride (PVC) bag-out bag. Additionally, in most cases, the nuclear material itself also releases HCl gas (due to residual chemical components associated with the material formation). The RRFMC drop tower gives the end-user the ability record and analyze high-speed video and photography and if needed aerosol mass release measurements. In this report the principal issue is the physical deformation of the 5Qt Hagan container. There were no mass release experiments of test aerosol mass in the present study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)

Deep Neural Network Assisted Distributed Strain and Temperature Fiber Sensor System for Natural Gas Pipeline Monitoring

Natural gas pipeline integrity monitoring is crucial to detect potential leaks, find structural issues, and prevent environmental damage. This article presents a system of natural gas pipeline monitoring that uses a specialized double Brillouin peak sensing fiber along with the Brillouin optical time domain analysis (BOTDAs) technique. The calibrated sensing fiber coefficients for strain and temperature are 41.8 kHz/ με and 0.9 MHz/°C for peak 1; and 47.2 kHz/ με , and 1.11 MHz/°C for peak 2, respectively. Initially, lab tests were performed by installing a short section of double Brillouin peak fiber (DBPF) on a 1-in steel pipe under pressure up to 1000 per square inch (psi) at elevated temperatures. Simultaneous distributed measurements of temperature and pressure-induced hoop strain were successfully measured. Considering the long processing speed to extract Brillouin frequency shift (BFS), we employ a novel probabilistic deep neural network (PDNN) framework for rapid BFS prediction. Additionally, using the Finite Element Method, the effects of the pipeline pressure on hoop strain were modeled and compared to the experimental hoop strain under the same set of pipeline conditions. Finally, an actual 4-in outer diameter steel natural gas pipeline was used for pilot-scale tests, where hoop strain was measured at various pressure levels. Leaks were simulated to demonstrate accurate pipeline integrity monitoring. At an internal pipe pressure of 1000 psi, hoop strain of approximately 300 με was observed, and the sensitivity was calculated as 0.28 με /psi. The results of this pilot-scale study demonstrated that the system is capable of performing distributed monitoring sufficient to detect pipeline pressure and the presence of leaks to ensure the safe operation of gas pipelines in the field.

03 NATURAL GAS

Hydrogen Leak Modeling for Development of Smart Distributed Monitoring Under Unintended Releases

Hydrogen is a versatile and clean energy carrier that can be produced from various renewable sources such as wind, solar, and hydropower. Hydrogen has the potential to play a crucial role in decarbonizing industrial processes that are currently reliant on fossil fuels and provide long-duration and/or seasonal energy storage to enable electricity decarbonization. Hydrogen can also be used as a fuel for fuel cell vehicles, providing a zero-emission alternative to traditional internal combustion engines. DOE launched the Hydrogen Energy Earthshot (Hydrogen Shot) in June 2021 to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). While promising, Hydrogen is highly-flammable, and in the presence of oxygen, it can form explosive mixtures. . Therefore, understanding leak scenarios is essential to evaluate and mitigate the safety risks associated with potential hydrogen leaks. An increased understanding of leak behavior, and having tools to model leaks, can help assess how hydrogen would disperse in different environments, influencing emergency response plans and safety measures, and identify potential issues with materials and design systems that can withstand the challenges posed by hydrogen. Recently, researchers have attempted to study hydrogen leaks for development of risk management strategies. However, the focus has been on closed or semi-closed spaces like storage rooms, vehicles, garages, and fueling stations - all promising locations for future hydrogen infrastructure. In this presentation, the modeling environment extends the span of research further by modeling hydrogen leak in an outdoor, open space. We will present the key challenges with modeling hydrogen leaks in an uncontrollable environment, how they were handled, and how modeling results informed sensor selection and placement. A Hydrogen research facility at the National Renewable Energy Laboratory (NREL) was used as a case study to model hydrogen leaks. In the future, Hydrogen wide area detection methodologies will be developed and tested at this site to monitor for unintended and operational hydrogen releases. The data generated from modeling will be used to develop a predictive model to detect hydrogen leak location based on concentration measured by sensors in this open space. Furthermore, the facility was also chosen because controlled hydrogen releases can be performed. A computational fluid dynamics (CFD) based modeling approach was taken to model hydrogen leak. The full-scale hydrogen facility was modeled with a large ambient domain. The electrolyzer at the facility can produce a controlled release rate of 27 kg-H2/hr. Site-specific atmospheric and weather condition data such as wind direction, wind speed at various altitudes, and temperature were used as inputs to the model. To capture the variability of weather conditions, a subset of the weather conditions experienced during daytime hours without precipitation over the course of three months was generated; using established data clustering techniques, a total of 100 condition sets were chosen. The results show statistical distributions and ranges of hydrogen concentrations at locations throughout the domain. These distributions are compared to experimental data from a constant mass flow, controlled hydrogen release at the facility. The stochastic wind conditions of the release make direct validation difficult, therefore, statistical comparison approaches were used. Wind conditions are found to significantly impact the release behavior, including direction and concentration. Sensor selection and placement is proposed for the facility and is now based on release behavior predicted for the facility given its weather patterns; this is much more informed than without the modeling results. The methodology and analysis procedure can be translated to other facilities using modified geometries and site-specific weather conditions. Hydrogen holds great promise as a renewable energy fuel, but ensuring safety in its production, storage, and use is paramount. Studying potential leak scenarios in an open space will help develop sensors to detect hydrogen on a large spectrum of concentration and eventually build a smart distributed monitoring system.

CFD

How efficiently can AI recognize Wireless Devices?

This poster presents a hardware benchmarking methodology for a 3-layer CNN waveform classifier deployed using ONNX Runtime on an NVIDIA Jetson AGX Orin. The dataset consist of 9 signal types, -30 to +30 dB SNR with 5dB increments. Benchmarking on the Jetson AGX Orin gave an accuracy of 91.9% and GPU throughput of 107,120 predictions/sec (23× faster than CPU). The Jetson GPU reached approximately 27M samples/sec with stable performance but fell below the 40 MHz rate needed for real-time radio feeds. Sustained testing of 5 minutes confirmed stable performance with no memory leaks, establishing a reproducible benchmarking baseline for future edge-deployment optimization.

99 - GENERAL AND MISCELLANEOUS

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve

Practical Insights on Applying Simulation-Based Control Methods in Experimental Studies

Advanced nuclear reactors are crucial to the future of energy both in the United States and around the globe. In contrast to the current operating fleet, they are characterized as being deployable in remote locations and able to operate in semi-autonomous or autonomous fashion. This leap forward necessitates a new reactor control paradigm. Because advanced nuclear reactors are still under development in the United States, the creation of new control methods to achieve autonomous operations has been based on systems modeling and simulation. However, an important factor in successfully deploying these new control methods is the ability to seamlessly transition from simulation environments to real-world settings. Control methods tested in both simulation and experimental settings need to be investigated in the context of advanced reactor applications. This work developed a series of simple controllers for Idaho National Laboratory (INL)’s Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor operating in load-following scenarios. These controllers were tested in both simulation and experimental settings, and a comparative performance analysis was performed. The simulation tests leveraged the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software developed in a previous stage of the current effort, along with the MARVEL Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The experimental tests leveraged the COMMAND software, MARVEL models, and the U.S. Department of Energy Microreactor Program’s Microreactor Automated Control System (MACS). MACS was developed to serve as a control method testbed. It was customized to mirror the MARVEL microreactor, and COMMAND enabled MACS to emulate the physics of MARVEL. The load-following controller was developed using the simulation platform, with efforts to emulate real systems by introducing actuator saturation and noise. These factors were incrementally accounted for in the controller design. After finalizing the controller design, it was implemented with the experimental setup. The experimental conditions tested included an initial test under conditions similar to the final simulation test, and two additional scenarios. The first scenario introduced additional actuator saturation to account for equipment aging over time, which was unknown to the controller. The second scenario introduced sensor delay, a phenomenon anticipated with the use of remote operations or wireless communication in advanced reactors. These tests revealed several notable differences. While the controller performed well in simulation, it exhibited several limitations when transitioning to hardware. The main challenges involved maintaining the steady-state target power, as evidenced by larger error values between the true reactor power and setpoint power, as well as persistent oscillations in controlled reactor power. These issues could lead to unacceptable transient conditions in real reactor testing. Introducing actuator aging and stochastic delays in the experimental setup significantly impacted controller performance, resulting in increased overshoot and undershoot, and exacerbated error and oscillations previously mentioned. These findings underscore the importance of experimental testbeds for testing and validating control methods, as controllers developed using only theory and/or simulation may perform unexpectedly when applied to actual hardware. This research emphasizes the need for an experimental testbed for achieving such validation.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Full Submersion Water Testing of SAVY-4000 Nuclear Material Storage Containers

SAVY-4000 (SAVY) containers are the primary container used at Technical Area (TA) TA-55 plutonium facility for the prevention of water ingress to mitigate against a criticality event. The basis for water resistance of these containers has long been attributed to the Polytetrafluoroethylene (PTFE) membrane that is assembled on the outermost surface of the filter assembly. On August 22nd a test of a container used inside of a glovebox was performed that brought into question this long-standing-basis. This test was performed by inverting a SAVY-lid onto a specialized piece of equipment for evaluating the integrity of the PTFE membrane. During the test water was observed passing through the filter indicating that the filter membrane was no longer preventing the ingress of water through the filter. The assumption after making this observation was that alpha-particles were rapidly degrading the membrane creating a leak path through the underlying aluminosilicate media (Fiberfrax®). The apparatus used was designed to only test the lid rather than the entire SAVY assembly. A test plan, PA-PLAN-01921, was developed to investigate whether a fully assembled container with a fully degraded PTFE membrane would be capable of meeting the criteria defined in PA-RD-1009 of not allowing more than 200 ml of water to enter the container with a water column of 6-inches applied over a 2-hour period. This report provides the results of the testing performed against PA-PLAN-01921.

36 MATERIALS SCIENCE

Formation of Composite SiC/SiC Joints by Embedded Wire Chemical Vapor Deposition

The joining of ceramic monoliths or composites to date has primarily been limited to the formation of brittle monolithic joints using heterogeneous (dissimilar) materials, similar to brazing in metals. The development of a damage-tolerant joint layer by SiC fiber reinforcements is demonstrated here. Tube workpieces made of SiC fiber-SiC matrix composite are joined using a nonwoven SiC fiber mat densified by embedded wire chemical vapor deposition (EWCVD), creating a fiber-reinforced weld-like joint by homogeneous joining. EWCVD uses a localized heating method to target deposition and growth to the joint region specifically, while minimizing thermal damage to the surrounding composite tube material. X-ray computed tomography (XCT) is used to nondestructively characterize as-made joints for relative density, adhesion, and composition. In situ XCT analysis during mechanical testing revealed crack deflections in the bonding layer, which indicates a toughening mechanism typical of ceramic matrix composite phase. Gas permeation testing of these proof-of-concept composite joints identified relatively high leak rates in comparison to fully coated SiC/SiC composite tube workpieces. In conclusion, the novelty of the composite joining method and current technology challenges, including gas permeability, are discussed in comparison with traditional ceramic joints and materials.

SiC

OES CO 2 Pipeline FEED Project Design Basis Memorandum

The OES CO₂ Pipeline project will move captured carbon dioxide from two ethanol facilities near Gibson City, Illinois, roughly 7.8 miles southeast to three injection wells outside Anchor, where it will be permanently stored underground. The system is designed to handle up to 4.5 million metric tonnes per year of dense-phase CO₂ at pressures up to 2,500 psig, using 16-inch mainline pipe and 10.750-inch laterals made from API 5L X-60 and X-65 steel. Wall thicknesses vary depending on location, with thinner pipe in open country, heavier wall at road crossings, and the heaviest where the pipe passes under highways or railroads via horizontal directional drill. The pipe gets a fusion-bonded epoxy coating, with an added abrasion-resistant layer wherever it's bored or drilled. Major water crossings will use HDD rather than open trenching. The pipeline will be cathodically protected, equipped with SCADA-compatible pressure and temperature instrumentation, and monitored for leaks using a computational pipeline monitoring system per API RP 1130. Hydrostatic testing will be performed at 1.25 times design pressure, and an ILI caliper run will follow to catch any construction defects. Several items, including fracture toughness requirements, specific NDE methods, and ILI tool selection, are left for the detailed design phase. The whole system falls under 49 CFR Part 195 and ASME B31.4, and Gulf Interstate Engineering prepared this document as the FEED-level design basis under the CarbonSAFE Phase III program.

09 BIOMASS FUELS

Reducing Methane Emissions with an Engine Fuel Reformer

Southwest Research Institute (SwRI) designed and demonstrated a compact, plasma-based fuel reformer designed to reduce methane leaks from natural-gas engines used in pipeline compression and industrial power applications. The system uses pulsed electrical discharges to convert a small portion of methane (CH4) into hydrogen (H2) and light hydrocarbons, promoting more complete combustion and reducing unburned methane in the exhaust. The reformer was evaluated through bench-scale testing, high-flow facility testing, and engine-integration testing on representative low-speed and high-speed natural-gas engines. Measured methane-leak reductions ranged from 1 to 27 percent, depending on engine type and operating condition, while reformer energy consumption remained below one percent of total engine output. Design refinements addressed thermal and electrical challenges, resulting in reliable operation with minimal impact on engine control systems. The project achieved all performance objectives within budget and schedule, produced a patentable pulsed-power system design, and established a scalable, energy-efficient pathway for mitigating methane leaks from existing natural-gas engine infrastructure.

03 NATURAL GAS

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE

Out-of-Pile Testing and Instrumentation Transient Water Irradiation System

Current initiatives to increase the burnup of conventional nuclear fuels past the approximate 62 GWd/t limit have been spurred on by direct savings to refueling and waste storage. The technical justification for a new license limit requires extensive qualification through experimental testing. Unlike beginning-of-life fuels, high-burnup fuels are more susceptible to fuel fragmentation, relocation, and dispersal (FFRD), therefore more data is needed to characterize fuels under key accident scenarios. The Transient Reactor Test Facility (TREAT) located at the Idaho National Laboratory has developed a testing apparatus architecture to test fuels and claddings at prototypic conditions. The Transient Water Irradiation System (TWIST) is the latest iteration of a testing device capable of conducting loss of coolant accidents (LOCAs) in TREAT. The Out-of-Pile Testing and Instrumentation TWIST (OPTI-TWIST) is an electrically heated device that is analogous to TWIST. OPTI-TWIST allows for detailed instrumentation and thermal-hydraulic characterization. TWIST ultimately aims to conduct the most advanced in-situ diagnostics to evaluate FFRD in a prototypic LOCA. Moreover, it will explore the phenomenological bifurcation of a decay-energy heat up driven LOCA and a stored-energy heat up driven LOCA. The instrumentation suite includes conventional thermocouples and pressure transducers in addition to an electro impedance sensor, an acoustic emission sensor, an optical pressure sensor, and an optical pyrometer. Characterizing these instruments in OPTI-TWIST eliminates complications of irradiation effects while preserving extreme thermal-hydraulic conditions. Finally, benchmarking both devices to a thermal-hydraulic code like the Reactor Excursion and Leak Analysis Program (RELAP)5-3D provides a unique opportunity for iteration. Pre-test predictions and post-test interpretations inform the physical designs, operational procedures, test conditions, and instrumentation types and positions.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Methane Mitigation Using Linear Motor Leak Recovery Compressor

GTI Energy (GTI), in collaboration with The University of Texas at Austin - Center for Electromechanics (UT‑CEM), designed, fabricated, and tested a linear motor–driven compressor intended to mitigate methane emissions at natural gas facilities across transmission, storage, gathering, and processing sectors of the gas value chain.

02 PETROLEUM

Fitness For Service Assessment of a Corroded Heat Exchanger

Within the Fermi National Accelerator complex, there exist various water systems that support accelerator operations. One of these systems is extremely vital to the operation of the machine; that is the cooling system. The cooling system consists of nine relatively large heat exchangers that take untreated pond water and use it to cool the process fluid that further cools machine components. Over the 30 years these heat exchangers have been in operation, they have undergone significant material loss on the channels. This material loss, due to various forms of corrosion such as galvanic and microbiologically influenced corrosion (MIC) and possibly others, has deteriorated more than 80% of the nominal wall thickness of some of the exchangers and placed them in a questionable state. ASME FFS-1 (API 579) has been applied to address the condition of the heat exchangers due to their noncompliance with the governing code, BPVC Sec. VIII Div. 1. The assessments encompassed ASME FFS-1 parts 4: General Metal Loss and 9: Crack Like Flaw using level 1, 2, and 3 analysis techniques based on inspection data obtained by API 510 inspections. Level 1 and 2 assessments were deemed unfit for the corroded regions due to their location relative to a major structural discontinuity (channel to tube-sheet joint), so a level 3 analysis was conducted according to ASME Sec. VIII Div. 2 (design by analysis) rules for pressure vessels. Supplemental information included pond water tests to determine an accurate future corrosion allowance due to lacking inspection history. A leak before break (LBB) route was chosen to evaluate the possibility of leaking prior to the onset of failure. The analysis of one heat exchanger shows that the possibility the channel will develop a pinhole leak over 2.5 more years of operation should not be overlooked, but burst was unlikely from operation. The use of fracture mechanics show, that if a through-wall crack were to develop, it would not propagate further than the channel geometry and cause a leak not greater than 35 GPM. Using ASME Section XI Code Case N-705-1, allowing us to operate with a leak until the next outage given certain operating conditions and developing a leak mitigation procedure, this heat exchanger is deemed fit-for-service.

Humenik, Alex [Fermilab]

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic

Device for steam cladding oxidation testing at TREAT

To compare the chemical degradation of conventional zirconium alloy (Zry) cladding to advance silicon carbide (SiC) cladding in a post loss of coolant accident (LOCA) environment, new nuclear testing capabilities are necessary. The Transient Reactor Test (TREAT) Facility at Idaho National Laboratory (INL) has matured its transient fuel testing capabilities since its 2017 restart. The most recent experiment architecture is the Transient Water Irradiation System in TREAT (TWIST), which is designed to support qualification of accident tolerant fuels in light water reactors. INL has designed and analyzed a natural circulation steam flow modification for TWIST to produce prototypic conditions of cladding oxidation. The in-situ device will be electrically heated to drive natural circulation. Moreover, the SiC cladding requires heating above 1700 °C to observe failure, thus internal prototypic nuclear heating with radiation effects will be used. Thermal hydraulic analysis with RELAP5-3D (Reactor Excursion and Leak Analysis Program) estimated steam fluxes greater than 50 mg cm −2 s −1 can be achieved. These fluxes are adequate to test Zry cladding according to draft regulatory guides and to test SiC cladding according to past experiments.

Oxidation