Search NASA⌕ Search

SEARCH · Search NASA

Results for “Light Extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

archi : pipeline for light curve extraction of CHEOPS background stars

ABSTRACT High precision time-series photometry from space is being used for a number of scientific cases. In this context, the recently launched CHaracterizing ExOPlanet Satellite (CHEOPS) (ESA) mission promises to bring 20 ppm precision over an exposure time of 6 h, when targeting nearby bright stars, having in mind the detailed characterization of exoplanetary systems through transit measurements. However, the official CHEOPS (ESA) mission pipeline only provides photometry for the main target (the central star in the field). In order to explore the potential of CHEOPS photometry for all stars in the field, in this paper, we present archi, an additional open-source pipeline module1 to analyse the background stars present in the image. As archi uses the official data reduction pipeline data as input, it is not meant to be used as an independent tool to process raw CHEOPS data but, instead, to be used as an add-on to the official pipeline. We test archi using CHEOPS simulated images, and show that photometry of background stars in CHEOPS images is only slightly degraded (by a factor of 2–3) with respect to the main target. This opens a potential for the use of CHEOPS to produce photometric time-series of several close-by targets at once, as well as to use different stars in the image to calibrate systematic errors. We also show one clear scientific application where the study of the companion light curve can be important for the understanding of the contamination on the main target.

Silva, André M.↗

Numerical Modelling of Sublimation Losses During Sample Handling Within the Light WAVE Lunar Water Prospecting Instrument

NASA’s focus of exploring the Moon’s south pole under the Artemis program has placed new emphasis on characterizing the quantity and distribution of water ice and other volatiles present within the Moon’s permanently shadowed regions (PSRs), first measured during the 2009 LCROSS mission. NASA’s VIPER rover is the first of a series of prospecting missions to characterize this water ice resource. NASA’s Johnson Space Center (JSC) has developed the Light Water Analysis and Volatiles Extraction (Light WAVE) instrument shown in Figure 1 for a follow-on prospecting mission, designed to be a rover payload for water ice prospecting at various depths and locations within PSRs. A key source of error for lunar water prospecting instruments, including Light WAVE, is the loss of water in an icy regolith sample to the lunar vacuum via sublimation due to heating above its ice-stable temperature. This abstract and conference presentation discuss a sublimation model for Light WAVE’s sample crucible using COMSOL Multiphysics to assess the sublimation losses that would occur between sample collection from an external drill and sealing the sample within Light WAVE’s boiler.

Lunar Polar Water↗

Near re-entrant dense pattern optical multipass cell

A multiple pass optical cell and method comprising providing a pair of opposed mirrors, one cylindrical and one spherical, introducing light into the cell via an entrance mechanism, and extracting light from the cell via an exit mechanism, wherein the entrance mechanism and exit mechanism are coextensive or non-coextensive.

Silver, Joel A.↗

High aspect ratio organic light-emitting diodes

Reliability is particularly challenging for organic light-emitting diodes (OLEDs) used in solid-state lighting applications, because OLED lifetime is inversely proportional to luminance, and most lighting applications demand high luminance. Here we introduce a strategy to overcome this tradeoff by constructing OLEDs on a substrate with sub-mm, high aspect ratio surface texture. By creating more active OLED area per unit lighting panel area, the device current density required to generate a given panel luminance decreases. We validate this approach for fluorescent and phosphorescent OLEDs, demonstrating good thickness uniformity on corrugated substrates with area enhancement factors up to 1.4x using a standard thermal evaporator. Relative to planar controls at the same panel current density, the high aspect ratio devices achieve a 2.7-fold increase in operating lifetime and up to a 40% increase in external light extraction efficiency, indicating that this approach offers a powerful pathway to improve the efficiency and lifetime of OLED lighting.

OLED↗

Patterned OLEDs: effect of substrate corrugation pitch and height

Abstract An ongoing OLED challenge is cost-effective enhancement of light extraction, i.e., increasing the external quantum efficiency ( EQE ∼20% in conventional devices). OLEDs on corrugated substrates often show enhanced EQE s providing insight into light emission processes. In particular, patterned plastic substrates directly imprinted easily at room temperature and amenable to low-cost R2R production are ideal for studying/optimizing various structures, further elucidating the extraction process. We show new semi-quantitative data of the effect of the pitch ( a ) and height/depth ( h ) of plastic substrate patterns on the OLEDs’ stack and EQE , focusing on new designs, interestingly, some showing surprisingly enhanced EQE s that were neither reported nor discussed before. These includ e : ( i ) shallow ( h < 200 nm) convex polycarbonate with a ∼ 750 versus ∼400 nm, where the h gradually decreases as the OLED stack is built and ( ii ) concave PET/CAB with large a (∼2.8 and ∼7.8 μ m), where the EQE enhancement of conformal OLEDs may be due largely to scattering. EQE s of green, blue, and white phosphorescent OLEDs were measured. OLEDs on substrates with narrow a ∼ 400 nm and low h < 200 nm s h owed no enhancement, resembling flat devices. In contrast, OLEDs on substrates with comparable or smaller h , but larger a ∼ 750 nm show signific a nt EQE enhancement despite h reduction across the stack. Green OLEDs with a ∼ 750 nm and h ∼ 160 to ∼180 nm, showed EQE s ∼30%, reaching ∼58% with substrate mode extraction. Surprisingly, fully conformal OLEDs on a PET/CAB substrate with a ∼ 7.8 μ m showed blue a nd white EQE s reaching ∼33%, without substrate mode extraction. The enhancing patterns increase the OLEDs’ EQE by reducing surface plasmon excitation and internal waveguiding. The experimental results for OLEDs on substrates with a < 2 μ m are supported by scattering matrix simulations that assume conformal stacks, incorporating diffraction for internal losses reduction. EQE enhancement not predicted by simulations may be due additionally to scattering mostly for substrates with a signific a ntly larger than the emitting wavelength.

42 ENGINEERING↗

Performance of Scintillation Detectors Based on Quantum Dots in a Semiconductor Matrix (Final Technical Report)

InAs Quantum Dots (QDs) embedded into GaAs semiconductor waveguide have unique scintillation properties, valuable for nuclear security, medical imaging, and high energy physics. In this work, we developed thick (~25um) epitaxial heterostructres with high luminescence efficiency composed of self-assembled nano-engineered InAs QDs grown by molecular beam epitaxy. In this type of detector, the GaAs matrix acts as a stopping material for charged particles or photons generating electrons captured by the QDs acting as luminescence centers. The QD medium is designed to provide fast capture of electrons into QDs (few ps), high QD luminescence efficiency at room temperature (>50%), and strong red-shift of photoluminescence (PL) from the GaAs absorption edge (>250nm). Typical devices consist of a 10-25um thick GaAs layer with embedded sheets of modulation p-type doped InAs QDs and an InGaAs photodetector tuned to the QD emission wavelength. The thick GaAs layer acts also as a waveguide when layer-transferred onto a low-index substrate. Waveguiding and self-absorption (~1cm -1 ) were studied using photoluminescence with scanning laser excitation and modeled with ray optics approximation and geometrical coupling of high-index waveguide to a collection fiber. Scintillating signals from α-particles were analyzed with both an external photodiode (PD) and an integrated PD which provided an improved optical coupling. In the former case, the external InGaAs PD was air-coupled to the scintillator and had the light collection efficiency of about 1% corresponding to limited light extraction through a planar interface with air due to total internal reflection. The mean charge collected by the integrated PD was in the range of (3÷5)×10 4 photoelectrons per 1 MeV of deposited energy, or ~13-20% of the theoretically achievable light yield. Timing of the integrated device was measured by wire-bonding it to the input of an 8 GHz IC. The scintillation response shows an extremely fast 0.3-0.6 ns decay constant and about 40-70 ps time resolution, limited by the system noise. The combined light yield and decay time makes the InAs/GaAs QD heterostructures the fastest high yield scintillation material reported making it valuable for high energy physics and medical imaging applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High Aspect Ratio OLEDs

Long-term reliability is especially challenging for organic light emitting diodes (OLEDs) used in solid-state lighting applications because OLED lifetime is inversely proportional to luminance, and most lighting applications demand high luminance. This project explored a new strategy to overcome this tradeoff by constructing OLEDs on a substrate with sub-mm, high aspect ratio surface texture. By creating more active OLED area per unit lighting panel area, the device current density required to generate a given panel luminance decreases. We validated this approach for both fluorescent and phosphorescent OLEDs, demonstrating good thickness uniformity on corrugated substrates with area enhancement factors up to 1.4x using a standard thermal evaporator. Relative to planar controls at the same panel current density, the high aspect ratio devices achieve a 2.7-fold increase in operating lifetime and up to a 40% increase in external light extraction efficiency. Experiments carried out on a pilot-line OLED manufacturing system demonstrated good coating uniformity, indicating that this approach has the potential to be implemented at scale and therefore offers a powerful pathway to improve the efficiency and lifetime of OLED lighting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The cyclotron gas stopper at FRIB getting ready for operations

Linear gas stopping cells have been used for nearly two decades to slow down projectile fragments at the National Superconducting Cyclotron Laboratory, now the Facility for Rare Isotope Beams, for experiments with low-energy and reaccelerated beams. In order to efficiently stop and rapidly extract light to medium-mass fast ions, a cyclotron gas-stopper has been constructed. It uses a cyclotron-type magnet and a helium-gas filled stopping chamber to slow down the injected beam. RF ion guides transport the stopped ions to the center of the magnet and axially through the bore before acceleration to <60 keV. Following successful offline tests, the cyclotron stopper was moved to an experimental vault and connected to a new momentum–compression beam line. Beam transport to and into the cyclotron stopper was tested with stable beams. Finally, using 46 K fragments, the first successful stopping and extraction of a high-energy beam with the cyclotron stopper was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multifunctional Optical Outcouplers for Efficient and Stable White OLEDs (Final Technical Report)

Replacing fluorescence by phosphorescence in OLED-based solid-state lighting can realize the Department of Energy’s efficiency target of 83% Internal Quantum Efficiency (IQE). The principal challenge, however, is to fix the poor stability of phosphorescent blue OLEDs. To address this, we have fabricated novel plasmonic architectures that improve device stability by decreasing the exciton lifetime of the emitters without drastically decreasing the light extraction efficiency. We describe the impact on stability of these structures in high efficiency blue phosphorescent OLEDs. Although the benefit is appreciable, we find that targeting ‘bright’ triplets on phosphorescent emitter molecules is an incomplete solution, and that it is also necessary to stabilize ‘dark’ triplets formed in the host and blocking layers. We demonstrate substantial improvements in stability using the latter approach, and conclude with a discussion of potential approaches to managing dark triplets in OLEDs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatially resolved x-ray detection with photonic crystal scintillators

We study the self-collimation phenomenon in photonic crystals (PhC) of wide bandgap materials for ultra-fast and high spatial resolution x-ray detection. We work on various heavy inorganic scintillators: BaF 2 , GaN, ZnO, CsI:Tl, NaI:Tl, LYSO, WO 4 compounds, and plastic scintillators. Conventional scintillator detectors do not rely on a direct detection mechanism; hence, they require intricate design and fabrication processes. We offer a PhC design to observe self-collimation phenomena and overcome the ongoing spatial resolution challenges with these types of materials. We investigate the photonic band diagrams and iso-frequency contours. Fourier transforms based on finite-difference time-domain and frequency domain simulations are done for verifying and analyzing the self-collimation with the selected material. Light extraction efficiency at the PhC–air interface, depending on the truncation distance from the excitation point, is measured. Beam divergence values are calculated at 1 mm propagation distance. The vertical field profiles are obtained to observe the confinement. For the spatial resolution analysis, cross-sectional beam profiles have been examined. Furthermore, Gaussian envelopes are fitted to beam profiles for a consistent data analysis, and full-width-at-half-maximum values are considered. As a result, we theoretically prove and demonstrate the spatially resolved x-ray detection at the sub-micrometer level for a wide range of scintillator materials.

36 MATERIALS SCIENCE↗

Modeling the co-assembly of binary nanoparticles

Abstract In this work, we present a binary assembly model that can predict the co-assembly structure and spatial frequency spectra of monodispersed nanoparticles with two different particle sizes. The approach relies on an iterative algorithm based on geometric constraints, which can simulate the assembly patterns of particles with two distinct diameters, size distributions, and at various mixture ratios on a planar surface. The two-dimensional spatial-frequency spectra of the modeled assembles can be analyzed using fast Fourier transform analysis to examine their frequency content. The simulated co-assembly structures and spectra are compared with assembled nanoparticles fabricated using transfer coating method are in qualitative agreement with the experimental results. The co-assembly model can also be used to predict the peak spatial frequency and the full-width at half-maximum bandwidth, which can lead to the design of the structure spectra by selection of different monodispersed particles. This work can find applications in fabrication of non-periodic nanostructures for functional surfaces, light extraction structures, and broadband nanophotonics.

Mohanty, Saurav (ORCID:0009000302592855)↗

Influence of Superlattice Structure on V-Defect Distribution, External Quantum Efficiency and Electroluminescence for Red InGaN Based µLEDs on Silicon

Achieving high quantum efficiency in long-wavelength LEDs has posed a significant challenge to the solid-state lighting and display industries. In this article, we use V-defect engineering as a technique to achieve higher efficiencies in red InGaN LEDs on (111) Si through lateral injection. We investigate the effects of superlattice structure on the V-defect distribution, the electroluminescence properties, and the external quantum efficiency. Increasing the relative thickness of In in the InGaN/GaN superlattice and the total superlattice thickness correlate with a reduction of active region defects and increased external quantum efficiencies. The highest measured on-chip EQE was 0.15% and based on Monte-Carlo ray tracing simulations for light extraction we project this would correspond to a flip-chip EQE of ~2.5%.

36 MATERIALS SCIENCE↗

Lunar and Planetary Science XXXV: Astrobiology

The presentations in this session are: 1. A Prototype Life Detection Chip 2. The Geology of Atlantis Basin, Mars, and Its Astrobiological Interest 3. Collecting Bacteria Together with Aerosols in the Martian Atmosphere by the FOELDIX Experimental Instrument Developed with a Nutrient Detector Pattern: Model Measurements of Effectivity 4. 2D and 3D X-ray Imaging of Microorganisms in Meteorites Using Complexity Analysis to Distinguish Field Images of Stromatoloids from Surrounding Rock Matrix in 3.45 Ga Strelley Pool Chert, Western Australia 4. Characterization of Two Isolates from Andean Lakes in Bolivia Short Time Scale Evolution of Microbiolites in Rapidly Receding Altiplanic Lakes: Learning How to Recognize Changing Signatures of Life 5. The Effect of Salts on Electrospray Ionization of Amino Acids in the Negative Mode 6. Determination of Aromatic Ring Number Using Multi-Channel Deep UV Native Fluorescence 7. Microbial D/H Fractionation in Extraterrestrial Materials: Application to Micrometeorites and Mars 8. Carbon Isotope Characteristics of Spring-fed Iron-precipitating Microbial Mats 9. Amino Acid Survival Under Ambient Martian Surface UV Lighting Extraction of Organic Molecules from Terrestrial Material: Quantitative Yields from Heat and Water Extractions 10. Laboratory Detection and Analysis of Organic Compounds in Rocks Using HPLC and XRD Methods 11. Thermal Decomposition of Siderite-Pyrite Assemblages: Implications for Sulfide Mineralogy in Martian Meteorite ALH84001 Carbonate Globules 12. Determination of the Three-Dimensional Morphology of ALH84001 and Biogenic MV-1 Magnetite: Comparison of Results from Electron Tomography and Classical Transmission Electron Microscopy 13. On the Possibility of a Crypto-Biotic Crust on Mars Based on Northern and Southern Ringed Polar Dune Spots 14. Comparative Planetology of the Terrestrial Inner Planets: Implications for Astrobiology 15. A Possible Europa Exobiology 16. A Possible Biogeochemical Model for Titan

Source record↗

Sub-electrode microlens array for organic light emitting devices

Substrates are disclosed that include an embedded or partially-embedded microlens array. Devices are disclosed that include an OLED disposed over a substrate having an embedded or partially embedded micro lens array. Devices as disclosed herein redirect up to 100% of the light that otherwise would be confined in organic and electrode layers toward the substrate and thus provide improved light extraction and device efficiency.

Forrest, Stephen R.↗

Extracting the distribution amplitude of light pseudoscalar mesons using the HOPE method

The pseudoscalar meson light-cone distribution amplitudes (LCDAs) are essential non-perturbative inputs for a range of high-energy exclusive processes in quantum chromodynamics. In this proceedings, progress towards a determination of the low Mellin moments of the pion and kaon LCDAs by the HOPE Collaboration is reported.

Chang, Alex [National Yang Ming Chiao Tung Univers↗

Monte Carlo calculations of the extraction of scintillation light from cryogenic $N$-type GaAs

We report the high scintillation luminosity of n-type GaAs at 10 °K is surprising because (1) with a refractive index of 3.5, escape is inhibited by total internal reflection and (2) narrow-beam experiments at 90 °K report infrared absorption coefficients of several per cm. This paper presents Monte Carlo calculations showing that the high luminosity at 10 °K can be explained if (1) the narrow-beam absorption is almost all optical scattering and (2) the absolute absorption coefficient is below 0.1 per cm. Sixteen surface reflector configurations are simulated for a range of internal scattering and absolute absorption coefficients, and these can guide the design of cryogenic scintillating GaAs targets for the direct detection of dark matter. The discussion section presents a possible infrared scattering mechanism based on the metallic nature of n-type GaAs. A supplement file describes (1) the Monte Carlo program steps in detail and (2) how narrow-beam and integrating sphere experiments can measure the cryogenic optical scattering and absolute absorption coefficients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field validation of data-driven BSDF and peak extraction models for light-scattering fabric shades

Shading and daylighting systems affect cooling, heating, and lighting energy use by modulating solar radiation through the building façade. Characterizing shading systems holistically and accurately helps designers and engineers evaluate shading systems to achieve energy and non-energy performance goals. These complex fenestration systems can be modeled using Bidirectional Scattering Distribution Functions (BSDF), which map incident radiation to hemispherical distributions of outgoing radiation. Data-driven, tabulated BSDFs are derived from interpolated goniophotometer measured data, then sampled during the raytracing calculation. A peak extraction (PE) algorithm was developed to circumvent limits in BSDF angular resolution, where the specular peak is extracted during simulation by evaluating the BSDF in the through direction and surrounding region. The objective of this study was to validate this measurement and modeling workflow using field monitored data from a full scale testbed with eleven installed fabrics of different weaves, openness factors, and colors and assess the accuracy of the workflow under different adaptation and contrast conditions. Test conditions were limited to clear sky conditions with the sun in the field of view. Results showed that, for tensor tree datasets, vertical illuminance, solar luminance (2.5° apex), and daylight glare probability (DGP) were predicted to within a mean bias error (MBE) error of -456 lx (-12.3%), -3.46e5 (-38.4%), and -0.042 (-7.8%) when full PE occurred. With a binary classification of glare/ no glare, DGP was predicted accurately with a true positive rate of 0.98 and true negative rate of 1.0 using tensor tree data and less accurately with Klems BSDF data, particularly for cases of no glare. The workflow may be of insufficient accuracy to distinguish borderline performance between fabrics using the four-point glare scale, particularly under low adaptation, high contrast daylit conditions. Errors were due to reductions in peak shape and intensity across the BSDF interpolation and data reduction workflow. Future work is needed to better preserve measurement fidelity during interpolation and sampling, which in turn will improve PE performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗