Search NASA⌕ Search

SEARCH · Search NASA

Results for “Light guides”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector↗

Visualizing Overall Water Splitting on Single Microcrystals of Phosphorus-Doped BiVO 4 by Photo-SECM

Particulate bismuth vanadate (BiVO4) has attracted considerable interest as a promising photo(electro)catalyst for visible-light-driven water oxidation, however, overall water splitting (OWS) has been difficult to attain because its conduction band is too positive for efficient hydrogen evolution. Using photo-scanning electrochemical microscopy (photo-SECM) with a chemically modified nanotip, we visualized for the first time the OWS at a single truncated bipyramidal microcrystal of phosphorus-doped BiVO 4 . The tip simultaneously served as a light guide to illuminate the photocatalyst and as an electrochemical nanoprobe to observe and quantitatively measure local oxygen and hydrogen fluxes. The obtained current patterns for both O 2 and H 2 agree well with the accumulation of photogenerated holes and electrons on {010} basal and {110} lateral facets, respectively. Furthermore, the developed experimental approach is an important step towards nanoelectrochemical mapping of the activity of photocatalyst particles at the sub-facet level.

bismuth vanadate↗

Probing Surface Plasmon Dynamics in Periodic Nanostructures through Ultrafast Electron Microscopy

Surface plasmon polaritons (SPPs) can be manipulated to localize and guide light in subwavelength distances, enabling them to find applications in a wide range of areas, from sensing to quantum computing. Among several methods of SPP excitation, periodic arrays of nano- and microstructures are of particular interest, as they enable engineering SPP properties through structural parameters. Here, in this study, using the photon-induced near-field electron microscopy (PINEM) technique, we investigated the mode formation, coupling, interference, and decay of SPPs in square and hexagonal arrays of circular nanoholes under both visible and near-infrared excitation. Polarization-resolved analysis revealed the key factors governing SPP localization and interference patterns, showing that the periodicity and symmetry of the array primarily determine the SPP interference patterns and their orientation, while pump polarization mainly modulates their intensity. Time-resolved PINEM measurements demonstrated the spatial dependence of the SPP temporal characteristics. In addition, cathodoluminescence (CL) spectroscopy was employed to examine the intrinsic plasmonic characteristics of the structure. Finite difference time domain (FDTD) simulations showed strong agreement with both PINEM and CL measurements on the spatial and spectral behavior of SPPs. Understanding the spatiotemporal dynamics of SPPs on nanostructures beyond the diffraction limit is crucial for optimizing plasmonic structures for advanced photonic and quantum technologies.

Plasmonics↗

A new neutron time-of-flight detector for yield and ion-temperature measurements at the OMEGA Laser Facility

A new neutron time-of-flight (nTOF) detector for deuterium–deuterium (DD)-fusion yield and ion-temperature measurements was designed, installed, and calibrated for the OMEGA Laser Facility. This detector provides an additional line of sight for DD neutron yield and ion-temperature measurements for yields exceeding 1 × 10 10 with higher precision than existing detectors. The nTOF detector consists of a 90-mm-diam, 20-mm-thick BC-422 scintillator and a gated Photek photomultiplier tube (PMT240). The PMT collects scintillating light through the 20-mm side of the scintillator without the use of a light guide. There is no lead shielding from hard x rays in order to allow the x-ray instrument response function of the detector to be measured easily. Instead, hard x-ray signals generated in implosion experiments are gated out by the PMT. The design provides a place for glass neutral-density filters between the scintillator and the PMT to avoid PMT saturation at high yields. The nTOF detector is installed in the OMEGA Target Bay along the P8A sub-port line of sight at a distance of 5.3 m from the target chamber center. In addition to DD measurements, the same detector can be used to measure the neutron yield and ion temperature from deuterium–tritium (DT) implosion targets in the 5 × 10 10 to 2 × 10 12 yield range. Here, the design details and the calibration results of this nTOF detector for both D 2 and DT implosions on OMEGA will be presented.

47 OTHER INSTRUMENTATION↗

New Roadmap for Microelectronics: Charting the Semiconductor Industry's Path Over the Next 5, 10, and 20 Years

In the past, the role of strategic planning for semiconductor industry was met by the International Technology Roadmap for Semiconductors (ITRS), serving as a guiding light that provided manufacturers, designers, equipment suppliers, and researchers with direction years in advance. By providing a common framework for coordination across semiconductor industry stakeholders, technology development efforts were efficient and aligned. However, the dissolution of the ITRS in 2015 left a void, leading to years of disjointed efforts. Recognizing the need for unified guidance, the industry rallied for the creation of a new strategic plan, the Microelectronics and Advanced Packaging Technologies (MAPT) Roadmap (2023) was developed, through the efforts of hundreds of industry, academic and government experts, to provide detailed strategies for achieving these goals. This comprehensive plan outlines ambitious goals for the industry's future.

HPC, Roadmap, AI, Liquid Cooling, Power, Silicon, ↗

Comparison of simulated and experimentally measured detector impulse responses to pulsed x-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

Simulating the X-ARAPUCA, DUNE's next generation light sensors

The word arapuca refers to a bird trap built by the indigenous peoples of Brazil. On the other hand, our ARAPUCA is a photon trap for Noble Gases' scintillation light and it is the sensitive element upon which DUNE's whole photon detection system is based on. Here we present a glimpse of our state-of-the-art simulation of such device, the ArapucaSim, highlighting its philosophy and main components. As an application, we present here one of the studies being carried out, on the effects of light reflections inside the light guide and how affects the overall photon detection efficiency. Based on these results, we are able to not only acquire a better understanding of the device but also impose limits on the quality of the mechanical polishing of such surfaces. The ArapucaSim was developed with two main goals in mind: to assist in R&D by allowing short turnout times between new ideas and experimental tests, and to bridge the gap between high-precision time-consuming hardware simulations and the full-scale models for DUNE's Photon Detection System. This research also led to the development new algorithms for simulating wavelength shifting/scintillation processes and dichroic filters, which will be properly described in future publications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance and Commissioning of the BigBite Timing Hodoscope for Nucleon Form Factor Measurements at Jefferson Lab

The BigBite Timing Hodoscope detector is the primary subject of this thesis. The Super BigBite Spectrometer is a Jefferson Lab Hall A Collaboration project that has and will continue to measure nucleon electromagnetic form factors. This spectrometer includes the Timing Hodoscope which provides high resolution particle timing data for scattered electrons in the electron arm of BigBite. The Timing Hodoscope utilizes 90, 25 × 25 × 600 mm3 scintillator bars stacked on top of each other to form a single detector plane, and these bars are connected to 180 photo-multiplier tubes via light guides. Particles collide with the scintillating material creating a shower of optical photons and these particle events in the bars are collected to generate signals that are readout by the data acquisition (DAQ) electronics. NINO ASIC amplifier-discriminator cards output signals from the photo-multiplier tubes into analogue and logic signals, which are sent to analogue-to-digital (ADC) and time-to-digital (TDC) converter data acquisition readout modules. This data is then used for analysis of the detector. The focus of this thesis is the construction, commissioning, calibration, and performance of the BigBite Timing Hodoscope before and during the first of five nucleon electromagnetic form factor experiments at Jefferson Lab Hall A. Before the neutron magnetic form factor, G n M, experiment, cosmic ray data was collected during commissioning to confirm proper operation of the Timing Hodoscope electronics by observing the ADC and TDC data. Commissioning studies for charge normalization, gain matching, and other ADC and TDC detector data variables were performed before moving the detector into Hall A. Following installation in Hall A, several calibration studies were implemented to fine-tune the detector in preparation for use in the experiment. The calibration studies included analysis of timing cuts, TDC alignment, the time-walk effect, time difference offsets, and scintillator velocity corrections. Once the Timing Hodoscope was well-calibrated, data-taking during the experiment commenced and the beam-on-target data was used to characterize the Timing Hodoscope performance during the G n M experiment run-time. The performance analysis included studies observing energy deposit, cluster size, rates, accidentals, pile-up, tracking efficiency, position resolution, and time resolution. After application of physics cuts to ensure a data set comprised of particle tracks corresponding to elastic electrons, which is the main data of interest for measurement of G n M, the Timing Hodoscope is shown on average across all kinematic settings to have a >98% tracking efficiency, a position resolution of 4-6 cm in the non-dispersive plane and 1.5-2 cm in the dispersive plane, and a time resolution of 500-750 ps. These performance results are compared to a GEANT4 based performance simulation of the BigBite Timing Hodoscope for reference, showing to what degree the measured performance values match those taken from the simulation.

Marinaro, Ralph↗

Integrated fluorescence light microscopy-guided cryo-focused ion beam-milling for in situ montage cryo-ET

Cryogenic-electron tomography (cryo-ET) permits the in situ visualization of biological macromolecules at the molecular level. Owing to the variable thickness of cells, tissues and organisms, frozen specimens may need to be thinned by cryo-focused ion beam (FIB) milling to produce thin (<500 nm) cryo-lamellae suitable for cryo-ET. Locating regions of interest remains a challenge because untargeted milling can lead to inadvertent ablation and removal of regions of interest. Correlative light and electron microscopy, combined with cryo-FIB milling, can guide the identification of labeled targets in the cellular milieu. Multiple transfers between cryo-imaging instruments, cumbersome correlation algorithms, limited accuracy and low throughput have hindered the routine adoption of cryo-FIB milling within a multimodal correlative workflow for in situ structural biology. Here, in this study, we present a workflow for 3D correlative cryo-fluorescence light microscopy-FIB-ET that streamlines fluorescence light microscopy-guided FIB milling, improving throughput while preserving both structural and contextual information. The complete integration of hardware and software described here minimizes sample contamination from cross-platform exchanges and greatly enhances the efficiency of 3D targeting in cryo-milling. We then describe procedures for implementing montage parallel array cryo-ET (MPACT), which can be easily adapted to any modern life-science transmission electron microscope. MPACT supports high-throughput cryo-ET acquisitions (10 tilt series in 1.5 h) for structure determination and comprehensive contextual understanding of macromolecules within their native surroundings. A complete session from sample preparation to MPACT data processing takes 5−7 d for an individual experienced in both cryo-EM and cryo-FIB milling.

Yang, Jie E. [Univ. of Wisconsin, Madison, WI (Uni↗

Heterogeneously integrated electro-optic modulator

In an electro-optical modulator, an electro-optical modulation layer is bonded to a cladding layer that overlies a substrate. A modulation zone waveguide is optically coupled to the electro-optical modulation layer and optically coupled to an I/O waveguiding structure embedded in the cladding layer. The I/O waveguiding structure is conformed to guide input light toward the modulation zone waveguide and to guide output light away from the modulation zone waveguide.

36 MATERIALS SCIENCE↗

Overview of Light Weight Radioisotope Heater Unit (LWRHU) User’s Guide

Idaho National Laboratory (INL) has recently compiled a user’s guide for the Light Weight Radioisotope Heater Unit (LWRHU). This guide gives an overview of the LWRHU to potential users. Information and data on mass properties, dimensions, thermal loads, and interfaces are discussed.

07 ISOTOPE AND RADIATION SOURCES↗

MFVI Energy Efficiency Audit Training - Module 1.1: Introduction to Efficient Lighting [Slides]

This guide is designed to help trained energy efficiency professionals conduct an energy efficiency audit for commercial and industrial buildings, particularly for micro-, small-, and medium-sized businesses in Mexico. This guide is focused on auditing lighting systems. As such, it will assist its user in determining the optimal lighting for a given space and then identifying the most efficient means of delivering that lighting.

21CPP↗

Volumetric Shaping of Nanoparticle-DNA Crystals by Light-Induced Milling

DNA-programmable self-assembly enables the formation of nanoparticle crystals with controlled lattice symmetry. While this approach offers the formation of complexly ordered nanostructures for optical, mechanical, and biological applications, a mesoscale control over such nanomaterials is limited. Directing the material formation process through the assembly pathway or external fields allows for modulating crystal morphology, but achieving arbitrary morphology remains challenging. Here, we present a photothermal method for shaping 3D DNA-programmable crystals of gold nanoparticles. Through local heating of nanoparticles due to plasmonic light absorption, we induce targeted volumetric dissolution of specifically defined crystal areas with micron-scale accuracy. This technique effectively prescribes crystal shaping and creates arbitrarily shaped voids within crystals. We further investigate both computationally and experimentally the key factors governing volumetric material subtraction. The developed automated light-milling platform enables the fabrication of nanomaterials exhibiting both DNA-programmable nanoscale order and custom-designed mesoscale architecture.

36 MATERIALS SCIENCE↗

Lighting: Development, Adoption, and Compliance Guide

The guide provides information for anyone dealing with a lighting energy code or standard. It provides background and development information to help readers understand the basis for requirements and their intent. The guide also provides detailed explanations of the major types of requirements such that users can more effectively design to meet compliance while applying the most flexibility possible.

Luminaires, IECC, code compliance, high-intensity ↗

3D Modeling of Safety-Related Upgrade Pilot Project

Constellation Energy and the United States Department of Energy (DOE) have established a public/private partnership to implement a pilot digital upgrade to replace legacy analog, safety-related reactor protection and emergency safety feature actuation systems (RPS/ESFAS) with modern digital systems. This effort is occurring at Constellation’s Limerick Generating Station. This project is being performed in accordance with industry processes that have been adapted to better support digital upgrades. These processes include IP-ENG-001, Standard Design Process, NISP-EN-04, Standard Digital Engineering Process and Electric Power Research Institute Report 3002011816, Digital Engineering Guide. The Light Water Reactor Sustainability (LWRS) Program at the Idaho National Laboratory (INL) has been supporting this effort. Latest INL HFE efforts in support of this project have focused on definition and implementation of the Human Factors Engineering (HFE) Program in support of Constellation design and related licensing efforts. This paper will present the development of the HFE 3D modeling execution of the Main Control Room safety upgrades. New equipment and modifications are planned for upgrading the new safety systems. 3D modeling allows for visualization of the new equipment and modifications to be shared with engineering and design teams for evaluation and review. Anthropometric considerations such as sight lines and functional reach can be evaluated directly using the 3D model. This effort has helped to provide visualizations for additional review with operations personnel and project stakeholders.

3D Modeling↗