Search NASA⌕ Search

SEARCH · Search NASA

Results for “Limit of detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Radiographic detectability limits for seeded voids in sintered silicon carbide and silicon nitride

Conventional and microfocus X-radiographic techniques were compared to determine relative detectability limits for voids in green and sintered SiC and Si3N4. The relative sensitivity of the techniques was evaluated by comparing their ability to detect voids that were artificially introduced by a seeding process. For projection microfocus radiography the sensitivity of void detection at a 90/95 probability of detection/confidence level is 1.5 percent of specimen thickness in sintered SiC and Si3N4. For conventional contact radiography the sensitivity is 2.5 percent of specimen thickness. It appears that microfocus projection radiography is preferable to conventional contact radiography in cases where increased sensitivity is required and where the additional complexity of the technique can be tolerated.

Baaklini, G. Y.↗

Thermal Infrared Spectral Band Detection Limits for Unidentified Surface Materials

Infrared emission spectra recorded by airborne or satellite spectrometers can be searched for spectral features to determine the composition of rocks on planetary surfaces. Surface materials are identified by detections of characteristic spectral bands. We show how to define whether to accept an observed spectral feature as a detection when the target material is unknown. We also use remotely sensed spectra measured by the Thermal Emission Spectrometer (TES) and the Spatially Enhanced Broadband Array Spectrograph System to illustrate the importance of instrument parameters and surface properties on band detection limits and how the variation in signal-to-noise ratio with wavelength affects the bands that are most detectable for a given instrument. The spectrometer's sampling interval, spectral resolution, signal-to-noise ratio as a function of wavelength, and the sample's surface properties influence whether the instrument can detect a spectral feature exhibited by a material. As an example, in the 6-13 micrometer wavelength region, massive carbonates exhibit two bands: a very strong, broad feature at approximately 6.5 micrometers and a less intense, sharper band at approximately 11.25 micrometers. Although the 6.5-micrometer band is stronger and broader in laboratory-measured spectra, the 11.25-micrometer band will cause a more detectable feature in TES spectra.

Kirkland, Laurel E.↗

Low-frequency Electromagnetic Detection Limits of Underground Nuclear Explosions

Underground nuclear explosions produce a broadband electromagnetic signal that can propagate to the surface at some distance. We perform a logistic regression on historical electromagnetic detections to calculate a probabilistic detection curve for prediction of the propagation distance for any given underground nuclear explosion. The curve predicts positive detections at scaled ranges of 2414.6, 2025.7, 1908.3, and 1672.4 m/ktonne 1/3 at probabilities of 50, 90, 95 and 99%, respectively. For a theoretical 100 ktonne underground nuclear explosion these scaled ranges translate to absolute ranges of 11.2, 9.4, 8.9, and 7.8 km at probabilities of 50, 90, 95 and 99%, respectively. We also motivate a need for improved electromagnetic sensor design and deployment by extending the detection analysis using the quoted signal-to-noise ratio of two and noise amplitude of 10 pT along with attenuation relationships that go as 1/r to 1/r 3 . We find that reducing the noise floor by a factor often could extend the detection limit to approximately 5 to 25 km/ktonne 1/3 , which translates to 24 to 112 km for a theoretical 100 ktonne underground nuclear explosion.

58 GEOSCIENCES↗

Breaking the Window of Detection: Using Multi-Scale Solute Tracer Studies to Assess Mass Recovery at the Detection Limit

Stream solute tracers are commonly injected to assess transport and transformation in study reaches, but results are biased toward the shortest and fastest storage locations. While this bias has been understood for decades, the impact of an experimental constraint on our understanding has yet to be considered. Here, we ask how different our understanding of reach- and segment-scale transport would be if our empirical limits were extended. We demonstrate a novel approach to manipulate experimental conditions and observe mass that is stored at timescales beyond the traditional reach-scale window of detection. We are able to explain the fate of an average of 26% of solute tracer mass that would have been considered as “lost” in a traditional study design across our 14 replicates, extending our detection limits to characterize flowpaths that would have been previously unmeasured. We demonstrate how this formerly lost mass leads to predicting lower magnitudes of gross gains and losses in individual reaches, and ultimately show that the network turnover we infer from solute tracers represents an upper limit on actual, expected behavior. Finally, we review the evolution of tracer studies and their interpretation including this approach and provide a proposed future direction to extend empirical studies to not-before-seen timescales.

54 ENVIRONMENTAL SCIENCES↗

Detection Limit of Smectite by Chemin IV Laboratory Instrument: Preliminary Implications for Chemin on the Mars Science Laboratory Mission

The CheMin instrument on the Mars Science Laboratory (MSL) is an miniature X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of detecting the mineralogical and elemental compositions of rocks, outcrops and soils on the surface of Mars. CheMin uses a microfocus-source Co X-ray tube, a transmission sample cell, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. CRISM and OMEGA have identified the presence of phyllosilicates at several locations on Mars including the four candidate MSL landing sites. The objective of this study was to conduct preliminary studies to determine the CheMin detection limit of smectite in a smectite/olivine mixed mineral system.

Archilles, Cherie↗

Development of Detectability Limits for On-Orbit Inspection of Space Shuttle Wing Leading Edge

At the conclusion of the Columbia Accident Investigation, one of the recommendations of the Columbia Accident Investigation Board (CAIB) was that NASA develop and implement an inspection plan for the Reinforced Carbon-Carbon (RCC) system components of the Space Shuttle. To address these issues, a group of scientists and engineers at NASA Langley Research Center proposed the use of an IR camera to inspect the RCC. Any crack in an RCC panel changes the thermal resistance of the material in the direction perpendicular to the crack. The change in thermal resistance can be made visible by introducing a heat flow across the crack and using an IR camera to image the resulting surface temperature distribution. The temperature difference across the crack depends on the change in the thermal resistance, the length of the crack, the local thermal gradient, and the rate of radiation exchange with the environment. This paper describes how the authors derived the minimum thermal gradient detectability limits for a through crack in an RCC panel. This paper will also show, through the use of a transient, 3-dimensional, finite element model, that these minimum gradients naturally exist on-orbit. The results from the finite element model confirm that there are sufficient thermal gradient to detect a crack on 96% of the RCC leading edge.

Stephan, Ryan A.↗

La 3+ and Y 3+ interactions with the carboxylic acid moiety at the liquid/vapor interface: Identification of binding complexes, charge reversal, and detection limits

Specific interactions of yttrium and lanthanum ions with a fatty acid Langmuir monolayer were investigated using vibrational sum frequency spectroscopy. The trivalent ions were shown to interact with the charged form of the carboxylic acid group from nanomolar concentrations (<300 nM). Analysis of the spectral features from both the symmetric and the asymmetric carboxylate modes reveals the presence of at least three distinct coordination structures linked to specific binding configurations. Although the same species were identified for both La 3+ and Y 3+ , they display a different concentration dependence, highlighting the ion-specificity of the interaction. From the analysis of the response of interfacial water molecules, the reversal of the surface charge, as well as the formation of yttrium hydroxide complexes, were detected upon increasing the amount of salt in solution. The binding interaction and kinetics of absorption are sensitive to the solution pH, showing a distinct ion speciation in the interfacial region when compared to the bulk. Changing the subphase pH or adding a monovalent background electrolyte that promotes deprotonation of the carboxylic acid headgroup could further improve the detection limit of La 3+ and Y 3+ to concentrations < 100 nM. These findings demonstrate that nM concentrations of trace metals contaminants, typically found on monovalent salts, can significantly influence the binding structure and kinetics in Langmuir monolayers.

01 COAL, LIGNITE, AND PEAT↗

Trace Element Analyses of Micron-Size Particles and Statistical Determination of Minimum Detection Limits

Savannah River National Laboratory (SRNL) has developed expertise in producing homogeneous, ca. 1 m-diameter spherical particles of mixed-element components, wherein dopants can be varied from a trace constituent (ppm) to wt.% concentrations. The samples used for this work are nickel-doped cerium oxide microspheres produced by SRNL. They were initially selected as analogs for plutonium-doped uranium oxide particles and analyzed as part of a larger study to evaluate whether electron probe microanalyzers (EPMA) can be used to characterize nuclear materials as an alternative or complementary method to mass spectrometers. The five samples used in this study contained nominal compositions of 0, 0.004, 0.04, 0.4 and 4 wt.% Ni. They were analyzed by both an Agilent 7900 Q-ICP-MS at SRNL and the JEOL JXA&#x2;8530F Plus EPMA at the University of Minnesota. In addition to EPMA results (calibrated with high-precision Q-ICP-MS analyses) suggesting that the EPMA could address outstanding nuclear material characterization needs, these samples 1) showcase the ability of the EPMA to quantify not just trace concentrations, but trace concentrations in microparticles (1 m diameter, Fig. 1), and 2) offer a unique opportunity to evaluate the methodology for assessing the minimum detection limits of EPMA analyses.

McSwiggen, Peter [JEOL USA, 11 Dearborn Road, Peab↗

Sensitivity and Detection Limit of Spectroscopic-Grade Perovskite CsPbBr 3 Crystal for Hard X-Ray Detection

We report spectroscopic-grade single crystal detectors can register the energies of individual X-ray interactions enabling photon-counting systems with superior resolution over traditional photoconductive X-ray detection systems. Current technical challenges have limited the preparation of perovskite semiconductors for energy-discrimination X-ray photon-counting detection. Here, this work reports the deployment of a spectroscopic-grade CsPbBr 3 Schottky detector under reverse bias for continuum hard X-ray detection in both the photocurrent and spectroscopic schemes. High surface barriers of approximate to ≈ 1 eV are formed by depositing solid bismuth and gold contacts. The spectroscopic response under a hard X-ray source is assessed in resolving the characteristic X-ray peak. The methodology in enhancing X-ray sensitivity by controlling the X-ray energies and flux, and voltage, is described. The X-ray sensitivity varies between a few tens to over 8000 μC Gy air -1 cm -2 . The detectable dose rate of the CsPbBr 3 detectors is as low as 0.02 nGy air s -1 in the energy discrimination configuration. Finally, the unbiased CsPbBr 3 device forms a spontaneous contact potential difference of about 0.7 V enabling high quality of the CsPbBr 3 single crystals to operate in "passive" self-powered X-ray detection mode and the X-ray sensitivity is estimated as 14 μC Gy air -1 cm -2 . The great potential of spectroscopic-grade CsPbBr 3 devices for X-ray photon-counting systems is anticipated in this work.

36 MATERIALS SCIENCE↗

Fiber-optic silicon Fabry–Perot interferometric bolometer with improved detection limit for magnetic confinement fusion

Fiber-optic bolometers (FOBs) intended for plasma radiation measurement in magnetically confined fusion have been previously developed using a silicon pillar that functions as both a Fabry–Perot interferometer (FPI) for temperature measurement and an absorber for the radiation. We report an FOB design that can significantly improve the detection sensitivity over earlier designs by engineering the absorber of the FOB. Our design uses the fact that, compared with a silicon pillar, a gold film with the same x-ray absorption thickness will show a much higher temperature rise from a given power density of the radiation. Therefore, the responsivity of an FOB can be improved by attaching a large gold disk to the silicon FPI as the absorber. We have developed a fabrication method for FOBs of such design and obtained an FOB with a 4-µm-thick, 0.6-mm-diameter gold disk attached to a 200-µm-diameter, 100-µm-thick silicon FPI. We have characterized the noise, responsivity, response time, and noise-equivalent power density (NEPD) and compared these with the earlier design where the absorber is mainly the silicon FPI itself. The experimental result suggests that the FOB with the gold disk achieves a responsivity of ∼2.8 mK/(W/m2) and a noise-equivalent-power-density of 0.13 W/m2, which are, respectively, more than nine times larger and six times smaller compared to the FOB using a previous design. Improved NEPD and good absorption over a broad frequency range will make the FOB more attractive for applications in magnetic-confinement fusion devices.

Uddin, Nezam↗

Detection Limits of Low-mass, Long-period Exoplanets Using Gaussian Processes Applied to HARPS-N Solar Radial Velocities

Radial velocity (RV) searches for Earth-mass exoplanets in the habitable zone around Sun-like stars are limited by the effects of stellar variability on the host star. In particular, suppression of convective blueshift and brightness inhomogeneities due to photospheric faculae/plage and starspots are the dominant contribution to the variability of such stellar RVs. Gaussian process (GP) regression is a powerful tool for statistically modeling these quasi-periodic variations. We investigate the limits of this technique using 800 days of RVs from the solar telescope on the High Accuracy Radial velocity Planet Searcher for the Northern hemisphere (HARPS-N) spectrograph. These data provide a well-sampled time series of stellar RV variations. Into this data set, we inject Keplerian signals with periods between 100 and 500 days and amplitudes between 0.6 and 2.4 m s{sup −1}. We use GP regression to fit the resulting RVs and determine the statistical significance of recovered periods and amplitudes. We then generate synthetic RVs with the same covariance properties as the solar data to determine a lower bound on the observational baseline necessary to detect low-mass planets in Venus-like orbits around a Sun-like star. Our simulations show that discovering planets with a larger mass (∼0.5 m s{sup −1}) using current-generation spectrographs and GP regression will require more than 12 yr of densely sampled RV observations. Furthermore, even with a perfect model of stellar variability, discovering a true exo-Venus (∼0.1 m s{sup −1}) with current instruments would take over 15 yr. Therefore, next-generation spectrographs and better models of stellar variability are required for detection of such planets.

47 OTHER INSTRUMENTATION↗

The Amazon River‐Breeze Circulation Limits Detection of Aerosol‐Cloud Interactions in Warm Clouds

Increased aerosol concentrations can brighten low-level clouds and extend their lifetimes, but aerosol–cloud interactions (ACI) remain highly uncertain and difficult to quantify. We show that part of this uncertainty is caused by topographical influences on clouds, that is, those arising from land–water contrasts. This is demonstrated using satellite retrievals in regions with extensive river networks, such as the Amazon Basin. 15 years of MODerate resolution Imaging Spectroradiometer (MODIS) satellite data show cloud formation over the Amazon River basin is suppressed by 26% with warm low clouds above the river exhibiting a 22% smaller droplet effective radius and 18% higher droplet concentration ($N_d$) compared to adjacent land clouds. Thus, clouds above the river may appear polluted but are actually influenced by river-breeze circulations driven by the thermal contrast between the river and the surrounding land. These responses are robust in both wet and dry seasons, and tests using an improved MODIS retrieval product show cloud differences are unlikely due to retrieval artifacts. In situ measurements from the Green Ocean Amazon Experiment (GoAmazon) confirm that $N_d$ is elevated above rivers and are also higher when carbon monoxide concentrations are elevated near the large city of Manaus. Lagrangian airmass tracking over Manaus shows that regional-scale river-breeze circulations impact $N_d$ as much as the urban aerosol plume, complicating ACI attribution and highlighting the need to isolate land-surface effects to assess ACI in continental regions.

Aerosol-Cloud Interactions↗

Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer↗

Extracting the gamma-ray source-count distribution below the Fermi-LAT detection limit with deep learning

We reconstruct the extra-galactic gamma-ray source-count distribution, or dN/dS, of resolved and unresolved sources by adopting machine learning techniques. Specifically, we train a convolutional neural network on synthetic 2-dimensional sky-maps, which are built by varying parameters of underlying source-counts models and incorporate the Fermi-LAT instrumental response functions. The trained neural network is then applied to the Fermi-LAT data, from which we estimate the source count distribution down to flux levels a factor of 50 below the Fermi-LAT threshold. We perform our analysis using 14 years of data collected in the (1,10) GeV energy range. The results we obtain show a source count distribution which, in the resolved regime, is in excellent agreement with the one derived from cataloged sources, and then extends as dN/dS ~ S -2 in the unresolved regime, down to fluxes of 5 · 10 -12 cm -2 s -1 . The neural network architecture and the devised methodology have the flexibility to enable future analyses to study the energy dependence of the source-count distribution.

79 ASTRONOMY AND ASTROPHYSICS↗