Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Business Case for Nonintrusive Load Monitoring

This report explores how utilities, researchers, and consumers could benefit from a lower cost approach to submetering using non-intrusive load monitoring (NILM). NILM is a process of using data from a single point of monitoring, such as a utility smart meter, to provide an itemized accounting of end use energy consumption in residential and small commercial buildings. Pacific Northwest National Laboratory (PNNL) prepared this report for the Bonneville Power Administration (BPA). PNNL participated in an advisory group as part of a research project sponsored by the U.S. Department of Energy (DOE), the Bonneville Power Administration, and the State of Washington. The Electric Power Research Institute (EPRI) convened the advisory committee for two workshops held to identify ways in which NILM may be used. PNNL, on behalf of DOE, helped to cosponsor the first of these workshops. Results of an end-use monitoring study of a bank branch conducted by PNNL are also presented for purposes of illustrating the need for better data in energy savings modeling (DOE 2013a).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Report On Non-Intrusive Load Monitoring Of Welding Processes

The conventional method of weld process monitoring is to monitor the process output electrical power close to the point of welding. Non-Intrusive Load Monitoring (NILM) describes the method of monitoring primary or utility electrical power into a welding process well away from the point of welding. The objective of this project was to determine if there is sufficient information within the welding process input power to understand process output power characteristics, and, if so, determine if there is sufficient resolution within the input electrical characteristics to infer some measures of weld quality. To understand the relationship between process input and output power, both input and output power were monitored for two welding processes (GMAW and GTAW) and two different power source types (inverter and SCR). Welds were made with and without intentional disturbances. The results showed that there is a strong correlation between input and output power and that the influence of process disturbances are evident within the input power. A simple method using input power only was devised and successfully demonstrated to discriminate between a weld made with no intentional disturbance (a nominal weld) from a weld made with an intentional disturbance (off-nominal weld). The primary conclusions of this work is that NILM of process input power is sensitive to process disturbances that could influence weld quality and that the approach warrants additional study.

36 MATERIALS SCIENCE↗

Non-Intrusive Load Monitoring of EBW Processes A Second Study [Slides]

The Objective is to Determine if induced off-nominal welding disturbances: (1) Beam arc out (weld on high vapor pressure aluminum plate); (2) Pulsed beam voltage; (3) Pulsed beam current; and (4) Pulsed beam focus current can be observed in the input power to the high-voltage cabinet powering the EB gun, ie Non-Instrusive Load Monitoring (NILM).

36 MATERIALS SCIENCE↗

Non-Intrusive Load Monitoring of HVAC Components using Signal Unmixing

Heating, Ventilating and Air Conditioning units (HVAC) are a major electrical energy consumer in buildings. Monitoring of the operation and energy consumption of HVAC would increase the awareness of building owners and maintenance service providers of the condition and quality of performance of these units, enabling conditioned-based maintenance which would help achieving higher energy efficiency. In this paper, a novel non-intrusive load monitoring method based on group constrained non-negative matrix factorization is proposed for monitoring the different components of HVAC unit by only measuring the whole building aggregated power signal. At the first level of this hierarchical approach, power consumption of the building is decomposed to energy consumption of the HVAC unit and all the other electrical devices operating in the building such as lighting and plug loads. Then, the estimated power signal of the HVAC is used for estimating the power consumption profile of the HVAC major electrical loads such as compressors, condenser fans and indoor blower. Experiments conducted on real data collected from a building testbed maintained at the Oak Ridge National Laboratory (ORNL) demonstrate high accuracy on the disaggregation task.

Flexible Research Platform↗

Field Trial of a Low-Cost, Distributed Plug Load Monitoring System

Researchers have struggled to inventory and characterize the energy use profiles of the ever-growing category of so-called miscellaneous electric loads (MELs) because plug-load monitoring is cost-prohibitive to the researcher and intrusive to the homeowner. However, these data represent a crucial missing link to understanding how homes use energy. Detailed energy use profiles would enable the nascent automated home energy management (AHEM) industry to develop effective control algorithms that target consumer electronics and other plug loads. If utility and other efficiency programs are to incent AHEM devices, they need large-scale datasets that provide statistically meaningful justification of their investments by quantifying the aggregate energy savings achievable. To address this need, NREL researchers investigated a variety of plug-load measuring devices available commercially and tested them in the laboratory to identify the most promising candidates for field applications. This report centers around the lessons learned from a field validation of one proof-of-concept system, called Smartenit (formerly SimpleHomeNet). The system was evaluated based on the rate of successful data queries, reliability over a period of days to weeks, and accuracy. This system offers good overall performance when deployed with up to 10 end nodes in a residential environment, although deployment with more nodes and in a commercial environment is much less robust. NREL concludes that the current system is useful in selected field research projects, with the recommendation that system behavior is observed over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Trial of a Low-Cost, Distributed Plug Load Monitoring System

Researchers have struggled to inventory and characterize the energy use profiles of the ever-growing category of so-called miscellaneous electric loads (MELs) because plug-load monitoring is cost-prohibitive to the researcher and intrusive to the homeowner. However, these data represent a crucial missing link to our understanding of how homes use energy, and we cannot control what we do not understand. Detailed energy use profiles would enable the nascent automated home energy management (AHEM) industry to develop effective control algorithms that target consumer electronics and other plug loads. If utility and other efficiency programs are to incent AHEM devices, they need large-scale datasets that provide statistically meaningful justification of their investments by quantifying the aggregate energy savings achievable. To address this need, we have investigated a variety of plug-load measuring devices available commercially and tested them in the laboratory to identify the most promising candidates for field applications. The scope of this report centers around the lessons learned from a field validation of one proof-of-concept system, called Smartenit (formerly SimpleHomeNet). The system was evaluated based on the rate of successful data queries, reliability over a period of days to weeks, and accuracy. This system offers good overall performance when deployed with up to ten end nodes in a residential environment, although deployment with more nodes and in a commercial environment is much less robust. We conclude that the current system is useful in selected field research projects, with the recommendation that system behavior is observed over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Advanced Boiler Load Monitoring Controls, Chicago, Illinois

Most of Chicago’s older multifamily housing stock is heated by centrally metered steam or hydronic systems. The cost of heat is typically absorbed into the owner’s operating cost and is then passed to tenants. Central boilers typically have long service lifetimes; the incentive for retrofit system efficiency upgrades is greater than equipment replacement for the efficiency-minded owner. System improvements as the “low-hanging fruit” are familiar, from improved pipe insulation to aftermarket controls such as outdoor temperature reset (OTR) or lead/lag controllers for sites with multiple boilers. Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. In this project, the Building America team Partnership for Advanced Residential Retrofit (PARR) installed and monitored an ALM aftermarket controller, the M2G from Greffen Systems, at two Chicago area multifamily buildings with existing OTR control. Results show that energy savings depend on the degree to which boilers are oversized for their load, represented by cycling rates. Also, savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, oversized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less oversized boilers at another site showed muted savings.

Building America↗

Load monitoring and compensation strategies for guided-waves based structural health monitoring using piezoelectric transducers

Accurate interpretation of in-situ piezoelectric sensor signals is a challenging task. This article presents the development of a numerical compensation model based on physical insight to address the influence of structural loads on piezo-sensor signals. The model requires knowledge of in-situ strain and temperature distribution in a structure while acquiring sensor signals. The parameters of the numerical model are obtained using experiments on flat aluminum plate under uniaxial tensile loading. It is shown that the model parameters obtained experimentally can be used for different structures, and sensor layout. Furthermore, the combined effects of load and temperature on the piezo-sensor response are also investigated and it is observed that both of these factors have a coupled effect on the sensor signals. It is proposed to obtain compensation model parameters under a range of operating temperatures to address this coupling effect. An important outcome of this study is a new load monitoring concept using in-situ piezoelectric sensor signals to track changes in the load paths in a structure.

environmental compensation↗

Draft Plan to Develop Non-Intrusive Load Monitoring Test Protocols

This document presents a Draft Plan proposed to develop a common test protocol that can be used to evaluate the performance requirements of Non-Intrusive Load Monitoring. Development on the test protocol will be focused on providing a consistent method that can be used to quantify and compare the performance characteristics of NILM products. Elements of the protocols include specifications for appliances to be used, metrics, instrumentation, and a procedure to simulate appliance behavior during tests. In addition, three priority use cases for NILM will be identified and their performance requirements will specified.

47 OTHER INSTRUMENTATION↗

Monitoring Loads In Fiber-Reinforced Composite Materials

In new method of determining load on specimen, direction of stress wave propagation measured by array of acoustic sensors attached to specimen. Responses of sensors analyzed by strain-energy-density calculations to calculate load. Change in anisotropy of elasticity caused by applied load and corresponding induced strain. Is means to monitor applied load corresponding to measurable shift in direction of propagation of stress wave. Monitoring device based on this method made integral part of airframe in which unidirectional section of structure, such as spar cap or longeron, carries primary load.

Prosser, William H.↗

Status of the FAA flight loads monitoring program

In support of the Federal Aviation Administration Aging Aircraft Research Program, the Agency has established a Flight Loads Data Collection Program for Commercial Aircraft. The objectives of this Program are to: - Review existing data collected by other sources including but not limited to U.S., Foreign, Military, etc. - Collect current operational usage data from both large and small transport aircraft - Develop criteria for future generations of transports. This paper presents the status of the various programs which are completed, underway or planned. The FAA will be collecting, storing, and analyzing the data which characterize typical commercial transport operations. The airframe manufacturers will handle the task of calculating the loads and stresses.

Aging Aircraft↗

Lockdown impacts on residential electricity demand in India: A data-driven and non-intrusive load monitoring study using Gaussian mixture models

This study evaluates the effect of complete nationwide lockdown in 2020 on residential electricity demand across 13 Indian cities and the role of digitalisation using a public smart meter dataset. We undertake a data-driven approach to explore the energy impacts of work-from-home norms across five dwelling typologies. Our methodology includes climate correction, dimensionality reduction and machine learning-based clustering using Gaussian Mixture Models of daily load curves. Results show that during the lockdown, maximum daily peak demand increased by 150-200% as compared to 2018 and 2019 levels for one room-units (RM1), one bedroom-units (BR1) and two bedroom-units (BR2) which are typical for low- and middle-income families. While the upper-middle- and higher-income dwelling units (i.e., three (3BR) and more-than-three bedroom-units (M3BR)) saw night-time demand rise by almost 44% in 2020, as compared to 2018 and 2019 levels. Our results also showed that new peak demand emerged for the lockdown period for RM1, BR1 and BR2 dwelling typologies. We found that the lack of supporting socioeconomic and climatic data can restrict a comprehensive analysis of demand shocks using similar public datasets, which informed policy implications for India's digitalisation. We further emphasised improving the data quality and reliability for effective data-centric policymaking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct-Write Printed Current Sensor for Load Monitoring Applications

We report on a flexible current sensor development employing direct-write printing and additive manufacturing techniques. The integrated current sensor unit incorporates sensing, data processing & storage, and in-field calibration capabilities. A combination of direct-write printing technique and low-temperature curable metallic ink is used to print Ag wires around a 12.5-μm -thick permalloy film. The overall thickness of the polyimide substrate and permalloy sheet remains well-below 500 μm enabling wrap-around sensor functionality. Fused deposition modeling (FDM) additive manufacturing is used to build custom parts for sensor mounting, encapsulation, and an in-field calibration unit using heat and chemical-resistant thermoplastic which responds well to mechanical stress. In the present configuration, the integrated current sensor unit can be powered through USB or 4 AAA batteries to allow data collection and sensor calibration in the field. The flexible current sensor employing a continuous sheet of the permalloy exhibited a well-behaved signal output response at peak current levels exceeding 15A and in the applied ac frequency range of 60 Hz–10 kHz. Overall, the combination of direct-write printing, thin permalloy material, and additive manufacturing technique shows promise for the development of a reconfigurable low-cost current sensor that can be deployed in large numbers at locations of interest to avail the cost and energy-saving opportunities in industrial/commercial and residential applications.

Yu, Yongchao↗