Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load coordination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evidence of Completion of Milestone 3: Experimental Testbed

Construction and deployment of the experimental testbed encountered scheduling delays, and completion was subsequently further delayed by curtailment of LANL operations due to the COVID-19 pandemic. Between March and October, LANL was in a state of “Limited Operations” such that only certain “mission-critical” work was performed with approximately 25% on-site staffing. In spite of this, much of the lab space preparation was executed and the five initial model house” units were constructed and installed during this period. Still, the pace of construction was impacted by difficulty in coordinating personnel and minimizing contact between workers. Currently, LANL is in the mode of “Normal Operations with Maximum Telework,” which continues to limit the availability of on-site personnel. Nevertheless, Milestone 3 is now complete. This document describes the experiment as it is deployed and provides status for each task for this milestone.

99 GENERAL AND MISCELLANEOUS↗

Evidence of Completion of Milestone 4: Simulation Testbed Validated with Experimental Data

Milestone 4 is given in the SOPO as being due in quarter 5 (ending 9/11/2020) and is described thus: Milestone 4: Enhanced Simulation Testbed Validated with Experimental Data (UM, Mathieu). Simulation testbed validated with data obtained from experimental testbed, specifically, nonlinear load behaviors and communication network issues observed in the experimental testbed will be modeled in the simulation testbed. The simulation testbed should accurately capture TCL real and reactive power consumption (including during extreme events associated with nonlinear behaviors and communication network failures) to within 5% RMSE error with respect to data obtained from the experimental testbed. The Tasks comprising the work to achieve Milestone 4 are outlined here.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evidence of Completion of Milestone 4: Simulation Testbed Validated with Experimental Data

Milestone 4 is given in the SOPO as being due in quarter 5 (ending 9/11/2020) and is described thus: Milestone 4: Enhanced Simulation Testbed Validated with Experimental Data (UM, Mathieu) Simulation testbed validated with data obtained from experimental testbed, specifically, nonlinear load behaviors and communication network issues observed in the experimental testbed will be modeled in the simulation testbed. The simulation testbed should accurately capture TCL real and reactive power consumption (including during extreme events associated with nonlinear behaviors and communication network failures) to within 5% RMSE error with respect to data obtained from the experimental testbed.

99 GENERAL AND MISCELLANEOUS↗

Controller Requirements for Managing Community Microgrids

Microgrid control systems are central to the functioning of a microgrid. They are responsible for managing distributed energy resources (DER) in both grid-connected and islanded modes of operation. Although microgrids are being developed and deployed by many utilities, several questions are being raised about the control system that manages them. This document provides the detailed list of requirements for a feeder-level microgrid controller to manage various islanded and grid-connected use cases. Functionally, the use cases include control scenarios that require the controller to maintain energy balance, prevent constraint violations, manage switching equipment, manage grid-forming (GFM) and grid-following (GFL) DER, manage critical/non-critical loads, and coordinate with peer systems to operate joined island areas. In addition to detailed requirements, the document includes interface and performance metrics for functional evaluation. These requirements can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; requirements also apply to third-party managed microgrid controllers that coordinate with the utility- and customer-owned equipment. The document can also be used by technology developers and project developers in industry to specify desired control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Building-to-Grid Modeling Framework with a Case Study of Battery Systems

Coordinating electricity load shifting operations of multiple buildings has the potential to achieve significant benefits for both building owners and grid operation. In support of this research, this paper develops a novel building-to-grid modeling framework, which uses EnergyPlus to develop physics-based building energy models and GridLAB-D to develop distribution-level grid models. The data exchanges between buildings and distribution-level grid are conducted using Python script and HELICS co-simulation platform. Then, by using this modeling framework, this paper conducts a case study of battery systems in a connected community, which consists of 10 multi-family buildings with appropriately sized batteries. The three scenarios, baseline operation, tolerant to price fluctuations, and opportune usage, are studied. The result displays that, by adopting onsite batteries, both electricity costs for building owners and aggregated peak power demands are reduced.

Building-to-grid, connected community, co-simulati↗

Control of Behind-the-Meter Resources for Enhancing the Resilience of Residential Buildings

There is increased concern about the impacts of frequent power outages, caused primarily by extreme weather conditions. With increasing behind-the-meter resources such as solar photovoltaics (PV), battery energy storage, and controllable loads, these resources - if properly coordinated - can meet critical loads even during an outage. Resilience building controls can coordinate and operate these resources to enhance the resiliency of buildings supporting critical loads for longer duration. In this paper, we present two resilience building controls: rule-based control and model predictive control (MPC). We simulated various scenarios considering different locations, seasons, outage types, and times of outages to evaluate the performance of resilience controls. The results show that MPC-based control can enhance resilience up to 65% compared to rule-based control. Similarly, PV self-consumption and occupant thermal comfort both increase during outages with MPC-based control.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Coordinatively and Spatially Coconfining High-Loading Atomic Sb in Sulfur-Rich 2D Carbon Matrix for Fast K + Diffusion and Storage

The atomically dispersed materials promise ultrafast redox kinetics for alkali-ion storage. However, their relatively low mass loading limits their application. In this work, well-dispersed Sb atoms with high-loading of 23.3 wt % anchored in sulfur-rich amorphous carbon-coated reduced graphene oxide matrix (SbSA/C) are prepared by a coordinative and spatial coconfinement methodology including freeze-casting the well-dissolved Sb-chelates (Sb-thioglycolate) within graphene oxide suspension and post heating-treatment. The reduced graphene oxide substrate features open two-dimensional spatial framework for loading atomically dispersive Sb species, and the pyrolyzed Sb-chelates would provide not only massive desirable heteroatoms (S, O) for coordinating the Sb atoms but also in situ pyrolytic carbon for further spatially separating those dispersive atoms. The coordinative and spatial coconfinement engineering also endows the SbSA/C composite with atomic-level Sb atoms against migration and agglomeration during electrochemical K-storage cycling. In situ TEM reveals the uniform potassiation behavior of the SbSA/C without obvious volume change; DFT calculation and electrochemical characterization suggest the significantly lower K-ion diffusion energy barrier. Therefore, on the basis of both the active Sb center and the coordinative heteroatom, the SbSA/C electrode delivers high fast-charging capacity, outstanding rate capability and long-lifespan performance in half/full K-ion batteries (e.g., a stable capacity of 331.3 mA h g –1 is maintained over 1100 cycles at 1.0 A g –1 for half-cell).

36 MATERIALS SCIENCE↗

NPP Simulators for Coupled Thermal and Electric Power Dispatch

The Light Water Reactor Sustainability (LWRS) program within the United States Department of Energy supports extending the operation of the U.S. commercial nuclear power plant (NPP) fleet. Within the LWRS program, the Flexible Plant Operation and Generation (FPOG) Pathway works to diversify the revenue streams of light water reactors (LWRs) by opening opportunities for the co-generation of non-electric products in addition to supplying electrical power to the grid. Recent events have added greater motivation to these efforts. For example, the recent Inflation Reduction Act (IRA) passed by the U.S. federal government offers substantial tax incentives for producing clean hydrogen, the technology readiness level of dispatchable and high-efficiency hydrogen production has dramatically increased in a short time, and societal response to world climate change is driving a transition away from fossil fuels. Producing hydrogen with maximum efficiency using nuclear power requires dispatching both electrical and thermal power from the nuclear plant to the hydrogen plant, so testing concepts of operations for combined electrical and thermal power dispatch (TPD) from an NNP to a hydrogen plant is of interest. This report documents achievement of the Light Water Reactor Sustainability (LWRS) program milestone “Install and demonstrate a vendor-developed simulator on the Human Systems Simulation Laboratory (HSS) for dispatch of LWR electrical power to a close-coupled electrolysis plant” with a due date of Dec. 22, 2022. Several factors provide motivation for this effort. Coupling the power generation deck of a nuclear power plant to a hydrogen production facility introduces new possibilities for operational transients that must be addressed. In particular, the performance of the integrated system during startup and shutdown of the hydrogen production facility, as well as offnormal conditions, need to be evaluated to ensure there are no adverse effects on the operation of the existing NPP. The concept of operations involving the NPP, the hydrogen plant, and the electric power grid must be tested using NPP simulators and operating procedures that have been modified for TPD operations. These tests must also include dynamic simulations of the coupled tertiary thermal and electric loads as well as coordinated activities with NPP operators, tertiary load operators and grid power coordinators. The report summarizes progress in developing and testing full-scope NPP simulators at the HSSL, including a generic BWR simulator from GSE Systems, Inc. and generic PWR simulator from Westinghouse. In the case of the TPD-GBWR Simulator from GSE Systems, Inc., a BWR is thermally coupled to a high temperature electrolysis (HTE) plant that produces hydrogen and oxygen from de-ionized water. The hydrogen plant is not explicitly simulated but only included as a transient heat sink. A thermal power dispatch (TPD) system transfers heat between the steam systems at the BWR and the hydrogen plant. Operational results from two versions of the modified simulator are presented. The first version uses synthetic oil as a heat transfer fluid in a closed delivery heat loop (DHL) that generates steam at the hydrogen plant. The second version uses steam as the heat transfer fluid in a delivery steam line (DSL) to provide steam to the hydrogen plant. For both versions, the estimated thermal power delivery distance is approximately one kilometer. The amount of thermal power dispatched in the simulators is 15% of the total reactor thermal power such that the simulators provide a tool to study the feasibility of coupling a BWR to industrial processes that benefit from a combination electrical and thermal power dispatch. Ongoing work within a CRADA is also developing a full-scope PWR simulator provided by Westinghouse for both thermal and electric power coupling. This simulator is based on a PWR plant with two three-loop Westinghouse reactors. Westinghouse PWRs are sufficiently similar that a simulator of a three-loop reactor is an appropriate representation for two-loop and four-loop PWR reactors. The three-loop simulator will initially be modified for close-coupling to a 100 MW HTE hydrogen production plant that will require approximately 25 MW of thermal power while operating at its maximum rated capacity. The simulator testing will include full coupling to dynamic simulations of a hydrogen production plant and a representative bulk electric grid. The simulator provided by Westinghouse is similar to the GPWR simulator that INL has already obtained from GSE Systems but has a few important added benefits. First, the Westinghouse simulator is based on digital controls and has additional screens that can be called up to show parameter trends to assist operators in decision-making. The Westinghouse simulator also has upgrades to the controls and hardware representations, such as valve actuators, that make it more realistic and flexible in terms of accurately sim

99 GENERAL AND MISCELLANEOUS↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Building Energy Systems as Behind-the-Meter Resources for Grid Services: Intelligent load control and transactive control and coordination

To mitigate the impacts of climate change, significant reductions in emissions from all sectors of the economy are needed. The electricity generation sector has embarked on an ambitious plan to include renewable generation as part of its decarbonization efforts, and many cities and states are mandating all-electric buildings. While renewable resources will reduce emissions, they are not dispatchable, they vary temporally, and their generation is uncertain. Under these conditions, traditional approaches to managing grid reliability, where supply follows demand, will not be efficient and may not be cost-effective. Further, there is a more efficient alternative for balancing the supply–demand imbalance and for absorbing variability and uncertainty of renewable energy using distributed energy resources (DERs) as opposed to reserve generation. Because buildings consume more than 75% of total U.S. annual electricity consumption, behind-the-meter (BTM) DERs have a load flexibility of 77 GW of power and 90 GWh of virtual energy storage capacity nationwide (Kalsi, 2017). Therefore, some portion of the supply–demand imbalance can be met by these DERs at a lower cost compared to business-as-usual solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

Load Shifting with Space Conditioning Heat Pumps During Heating Season in the Pacific Northwest

Ductless mini- and multi-split heat pumps are commonly deployed in Pacific Northwest residences, which historically have inefficient space heating and no space cooling. Heat pumps provide these residences with more energy-efficient space heating in the winter and space cooling for increasingly warm summer periods. For many of these applications, heat pumps add a new electrical load at the residence, compelling regional utilities to seek to understand their impacts on the electrical grid and opportunities for load management. In coordination with regional utilities, this study examined the winter load-shifting potential of residential multi-split heat pumps with variable capacity technology. The study included nine residential sites with a total of 20 ductless indoor units, which underwent simulated smart grid control. Grid control functionality was provided through the CTA-2045 communication protocol and included offsetting temperature setpoints for individual indoor units in the study. Field data collection included whole-house and heating, ventilation, and air conditioning electrical power consumption; indoor zone temperatures; occupant surveys; and CTA-2045 curtailment data for both baseline and simulated load-shifting events by site. This paper provides an overview of the load-shifting strategies and aggregated results from winter data collection.

ASHRAE, Heat pump, energy effciency, residential b↗

Coordinated Optimal Control of PV Inverters and HVAC Loads in Distribution Systems

The increasing integration of distributed energy resources (DERs), such as photovoltaics (PVs) and smart buildings into distribution systems complicate power system operation and controls. This paper proposes a coordinated optimal control strategy for PV inverters and Heating, ventilation, and air conditioning (HVAC) loads in smart buildings to minimize the total network loss in a distribution system. For the HVAC units, we enforce minimum on and off time constraints to avoid frequent switching that can degrade the unit. The proposed control will dispatch optimal control signals of active and reactive power to PV inverters and on/off commands to HVAC units while maintaining the nodal voltage within a secure range and the temperature of HVAC units at a comfort level. The simulation results on a modified IEEE 33-node distribution system demonstrate that the proposed coordinated control scheme can reduce the network loss.

Pani, Naveen↗

Bond clusters control rupture force limit in shear loaded histidine-Ni 2+ metal-coordinated proteins

Dynamic noncovalent interactions are pivotal to the structure and function of biological proteins and have been used in bioinspired materials for similar roles. Metal-coordination bonds, in particular, are especially tunable and enable control over static and dynamic properties when incorporated into synthetic materials. Despite growing efforts to engineer metal-coordination bonds to produce strong, tough, and self-healing materials, the systematic characterization of the exact contribution of these bonds towards mechanical strength and the effect of geometric arrangements is missing, limiting the full design potential of these bonds. In this work, we engineer the cooperative rupture of metal-coordination bonds to increase the rupture strength of metal-coordinated peptide dimers. Utilizing all-atom steered molecular dynamics simulations on idealized bidentate histidine-Ni 2+ coordinated peptides, we show that histidine-Ni 2+ bonds can rupture cooperatively in groups of two to three bonds. We find that there is a strength limit, where adding additional coordination bonds does not contribute to the additional increase in the protein rupture strength, likely due to the highly heterogeneous rupture behavior exhibited by the coordination bonds. Further, we show that this coordination bond limit is also found natural metal-coordinated biological proteins. Using these insights, we quantitatively suggest how other proteins can be rationally designed with dynamic noncovalent interactions to exhibit cooperative bond breaking behavior. Altogether, this work provides a quantitative analysis of the cooperativity and intrinsic strength limit for metal-coordination bonds with the aim of advancing clear guiding molecular principles for the mechanical design of metal-coordinated materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Evaluation of Distributed Energy Resources Management System via Advanced Hardware-in-the-Loop Simulation: Preprint

This paper presents an advanced hardware-in-the-loop (HIL) platform to evaluate the performance of voltage regulation coordinated across advanced distribution management systems (ADMS), distributed energy management system (DERMS), and DERs. The HIL platform provides realistic laboratory testing, including accurate modeling of the real-world distribution system from a utility partner, real controller (ADMS and DERMs) and power (DERs) hardware, and standard communications protocols. The test results show proper functionalities of the integrated platform and performance of the peak load management of coordinated control systems. Based on the laboratory testing, the utility can set up the same grid automation system to manage DERs to achieve system-level control and operation objectives (e.g., peak load management), thus derisking potential issues (e.g., instability) for field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Modeling of Electric Grid and Natural Gas Network Operations

Presentation based upon full report of a Colorado case study and coordination framework, which is available at https://www.nrel.gov/docs/fy20osti/77096.pdf. JISEA analysts Brian Sergi, Omar Guerra, and Bri-Mathias Hodge will present on recent JISEA work on coordination between the natural gas and electricity sectors. Power and gas are becoming increasingly interdependent but weren't designed to function together. How does greater coordination impact system operations with different levels of solar and wind penetrations? This free JISEA presentation will take place in a Webinar on Tuesday, May 11, 2021 at 12 p.m.: Learn how greater coordination between the natural gas and electricity sectors impacts system operations with different levels of solar and wind penetrations. Presentation information includes: Historical and projected data for natural gas consumption and power generation in the United States as demonstrated by 2014 East Coast Polar Vortex, 2021 Texas Winter Storm Uri. Showing coupling points, FERC identified need for better coordination, different levels of coordination (decision making and optimization control), coordination framework. Case study on Colorado Front Range, ramping requirements and gas nominations, real-time dispatch (June and December scenarios), results of analysis of impacts of coordination on unserved load. Total real-time gas offtakes by node, impacts on unserved gas, effect on CO2 emissions. Discussions on clusions drawn from Colorado Case study expanded co-simulation via HELICS, objectives of the HELICS+ natural gas use case, modeling of hydrogen blending, techno economic assessment of blending, and blending impacts on energy content and pressure.

analysis↗

Community-Based Transactive Coordination Mechanism for Enabling Grid Edge Systems

The changing landscape of the electricity industry, characterized by a surge in distributed energy resources (DERs) and proactive customers, necessitates practical solutions for coordinated operations especially at the distribution-level. This paper introduces a community-based transactive coordination mechanism designed to incentivize customers for providing localized and system-level services reflected through real-time prices. The work presents a bidding approach for communities with DERs, such as solar photovoltaic (PV) and battery energy storage systems (BESS), to formulate their price-responsiveness for retail energy coordination, emphasizing a community-centric model. By sending bidding curves to a third-party, the mechanism enables customers with DER assets to actively participate in localized coordination with the load serving entity (LSE), thereby supplementing each other’s and even the utilities needs through a shared energy economy. The proposed transactive mechanism is implemented leveraging a co-simulation framework that integrates a distribution grid simulator and Python-based agents for performance evaluation. Collaboration with a local utility to access real distribution feeder models and consumption profiles yields simulation results demonstrating the potential to reduce costs by 12\% for communities with DERs like PV and BESS.

Community-based coordination, grid-edge systems, R↗

Reliability and Resiliency in South Asia's Power Sector - Pathways for Research, Modeling, and Implementation

Reliability and resilience are the core principles of power system planning and operations around the world. Power systems in South Asia are transforming with increasing penetration of clean energy generation resources, emerging technologies, increasing electricity demand and electrification. At the same time, these power systems are facing challenges posed by extreme weather events and climate change. All these factors would add furthermore importance to the reliability and resilience of future power systems in South Asia. This has motivated us to better understand the country specific challenges and chalk out the pathways for research, modelling and implementation in South Asia. Our research, experience in the region and feedback from key stakeholders indicate following as the key areas where more work is needed to improve reliability and resilience of power systems in the region: Renewable energy Data for power system studies, New Tools and Studies, Resilience Planning, Resource Adequacy, Advanced RE Forecasting, Cybersecurity, Load Forecasting, and Coordinated Planning and Operations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗