Smart building HVAC control challenge: experience and solutions from the ADRENALIN project

A smart building HVAC control competition crowdsourced and compared algorithms on fair and equal ground using the standardized BOPTEST framework. The competition attracted 138 participants, but only 9% submitted valid solutions for the final stage, highlighting the complexity of advanced HVAC control design. The winning solutions showed significant potential to reduce energy use and cost by shifting demand, without compromising occupant comfort. Across scenarios, thermal energy cost reductions of 36–76% relative to a baseline, were achieved. In peak heat periods, the cost reduction leveraged limited energy use reduction (0–15%), but more significant energy price reduction (34–62%). This shows smart controls' ability to avoid as much as possible consumption during the morning peak hours, when spot prices are tendentially the highest. Hosting the competition has highlighted challenges in creating competitions that both are fair and promotes solutions that are transferable to real life implementation.

BOPTEST

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Glauber’s Salt Composites for HVAC Applications: A Study on the Use of the T-History Method with a Modified Data Evaluation Methodology

Phase change materials (PCMs) can be utilized in buildings for peak load shifting in air conditioning systems, and the use of salt hydrate-based PCMs can reduce the cost of thermal energy storage devices. Glauber’s salt is an economical salt hydrate PCM with a melting point of around 32 °C. However, the desired melting range typically falls between 18 and 22 °C for building air conditioning applications. Although many researchers have characterized Glauber’s salt and its composites with modified melting points, enthalpy–temperature curves for composites of Glauber’s salt and NaCl are unavailable. In this study, we report the melting and solidification enthalpy–temperature curves for two different composites of Glauber’s salt and NaCl with a melting point of 21 °C obtained by the T-history method. Both composites contain NaCl to suppress the melting point, borax to reduce supercooling, and sodium polyacrylate as a thickener to enhance cyclic stability. The first composite with 12 wt.% NaCl demonstrated 139 kJ·kg−1 of latent heat of fusion, and the second composite with 9 wt.% NaCl demonstrated 171 kJ·kg−1. Both the composites have high volumetric energy densities compared to their organic counterparts with similar melting points.

Chemistry

Prime Time for Model-Predictive Control? Assessing the Technical and Market Readiness of Advanced Controls in Buildings

Despite three decades of extensive research and field testing that have consistently validated the benefits of Model Predictive Control (MPC) in building applications, the technology has seen limited market adoption. This paper evaluates the readiness of MPC for widespread deployment, showcases recent demonstrations and field tests across diverse building types, including residential, small commercial, large commercial, and campus settings. Our results demonstrate that MPC can optimize system operations to achieve load shifting, minimize curtailment of on-site generation, and reduce energy costs by up to 80 %, while maintaining or improving occupant comfort. We also show that MPC can effectively control large assets, such as MW-sized thermal storage systems, and respond to dynamic pricing signals. However, achieving scale remains difficult due to labor-intensive workflows, reliance on a “PhD-in-the-loop” for MPC design and maintenance, susceptibility to fragile data infrastructure, and persistent workforce education and acceptance barriers. To bridge this gap, we outline a transition from bespoke, labor intensive prototypes toward streamlined, segment-targeted deployment strategies that leverage model templates, semantic tools, and generative AI. By automating control configuration and reducing engineering effort, these recommendations provide a pathway for transforming successful research demonstrations into scalable, market ready solutions for MPC-based controls.

Pritoni, Marco

Crustal Deformation and Gravitational Effects From Dynamic Ocean Mass Redistribution Impact Projected Sea‐Level Change

As the climate warms, associated changes in ocean dynamics will redistribute sea‐water mass within the ocean, contributing to relative sea‐level change. This mass redistribution will cause additional sea‐level changes due to gravitational self‐attraction, deformation of the solid Earth, and shifts in the Earth's rotation axis (GRD), which are not incorporated in sea‐level projections. Using CMIP6 climate model output, we quantify relative sea‐level changes induced by GRD from ocean‐dynamic mass loading through 2100. These effects act to amplify projected ocean‐dynamic sea‐level patterns, causing sea‐level rise in coastal regions, particularly along wide continental shelves and at high latitudes. On average, the magnitude of such GRD‐induced sea‐level change is equivalent to ∼15% of the signal due to dynamic ocean mass redistribution. Although our results show substantial inter‐model spread, they reveal that GRD‐induced relative sea‐level changes from ocean mass redistribution represent a non‐negligible component of regional sea‐level change and should be considered in projections.

58 GEOSCIENCES

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631

Treatment of Lagoon Dairy Manure Wastewater via Iron Electrocoagulation, Microfiltration, and Adsorption

Dairy manure wastewater generated by flushing barn cow waste contains nutrients, pathogens, and organic and inorganic contaminants. This study utilized a process consisting of iron electrocoagulation (Fe-EC), microfiltration (MF), and activated carbon (AC) adsorption to treat farm wastewater and explore the reclamation of clean water for irrigation and livestock consumption. Significant removal (>99.9%) of chemical oxygen demand (COD), total organic carbon (TOC), phosphorus (P), turbidity, and microorganisms, as well as ions including magnesium, calcium, sulfur, and silica was achieved by the combined EC-MF-AC process. Specifically, a charge loading of ∼37,500 C/L in a continuous-flow EC configuration, followed by MF, achieved more than 95% removal of TOC and COD. Characterization of produced flocs and foam via scanning-electron microscopy with energy-dispersal spectroscopy and Fourier transform infrared spectroscopy confirmed the removal of ions, including calcium, sulfur, and silica. A key finding was the electrocatalytic conversion of nitrogen species to ammonia gas through the intermediate reduction of nitrate/nitrite, which led to ∼60% total nitrogen (TN) removal. AC treatment further improved TN removal to ∼70%. The Fe-EC process also eradicated >99.9% of bacteria. Preliminary process cost assessment, based on recycled materials for EC electrodes, showed significant cost savings (∼2 times) compared to commercial electrodes.

Dutta, Swapnamoy [ORNL]

Sensitivity Analysis of Numerical Modeling Input Parameters on Wind Turbine Loads in Deterministic Transient Load Cases

Aero-hydro-elastic-servo numerical models used to design and analyze wind turbines are based on thousands of variable input parameters that dictate the inflow, aerodynamic, structural, and control characteristics of the system as well as sea state, hydrodynamic, and mooring characteristics for fixed-bottom and floating offshore wind turbines. Each of these parameters has some level of uncertainty, which can significantly impact the predicted loads. Understanding the uncertainty in the inputs is critical to understanding the uncertainty in the outputs. This work demonstrates a screening technique to identify which parameters ultimate loads are most sensitive to so that more focus can be given to quantifying the possible range of those parameters. This technique has been demonstrated previously for different turbine and load case types and is extended here for a floating offshore wind turbine in design load cases with transient events both in the inflow and operations. Each load case features a deterministic gust, including variations in wind speed, direction, and shear. Load cases are considered with an operating turbine as well as with prescribed fault, startup, and shutdown procedures. The study found that key input parameters with a large impact on loads include the length of the gust, the magnitude of direction change and speed in the gust, the initial wind speed, and the shape of the gust profile.

17 WIND ENERGY

Oversizing and Part-Load Problems

Oversizing, the common engineering practice of specifying devices with capacity exceeding the actual load requirement, is a widespread practice across virtually all building technologies end-use categories, including HVAC, electrical systems, lighting, appliances, and plug loads. This practice, driven by factors like design uncertainty, institutional pressures, and risk aversion, results in wasted capital investment, control difficulties, and excessive energy consumption due to inefficient part-load operation. Part-load operation, where devices run below maximum capacity, is the dominant operating mode in most energy systems and presents a complex design challenge. Solutions to match output to load fall into three broad categories: constraining the output, adjusting the device’s internal behavior, and linking output to energy storage or other waste-heat reuse applications. The energy implications of part-load are critical, as efficiency often drops sharply as load decreases across a wide diversity of devices. To quantify the extent of this problem, we derive a dimensionless Part-Load Metric (PLM) based on device efficiency and its frequency distribution of operating hours at various output levels. The PLM quantifies the deviation of a device's actual efficiency from its maximum design efficiency. This metric also serves as a measure of "capital inefficiency," enabling engineers to compare the impact of different part-load solutions and providing a unified framework for evaluating performance across various devices and systems.

Meier, Alan

Powering Large Loads: Solutions Across Transmission, Utility, and Facility Scales

This report synthesizes current strategies for accommodating large load growth through a review of publicly available technical literature and media insights around the United States (U.S.). Solutions are organized across three implementation scales (transmission, utility, and facility) and categorized according to common implementation pathways (including structural expansion, operations and efficiency, upgrades, and planning and policy).

Valdez, Raquel Lynn [Sandia National Laboratories

A Unified Beam-Dynamics and Hardware Design Framework for Hybrid Nonlinear-Kicker Injection in NSLS-II

Nonlinear kickers (NLKs) enable off-axis injection in ultralow-emittance storage rings by providing a strong kick to the injected beam while remaining nearly transparent to the stored beam. In hybrid schemes, a conventional four-kicker bump defines the injected trajectory, and the NLK reduces the first-turn action under constrained beam offset and optics conditions. Effective operation additionally requires stable and reproducible first-turn injection trajectories. We develop a compact action–angle framework that expresses NLK dynamics in terms of Courant–Snyder invariants and yields an analytical bound on achievable action reduction. This formulation provides direct design rules for NLK placement, phase advance, injected-beam offset, and kicker field profile. Within this framework, we identify the 8-wire NLK as a practical baseline and extend its design by relaxing the square-geometry constraint, enabling inward shifting of the off-axis field peak while preserving on-axis field and gradient cancellation. Application to the NSLS-II lattice shows how aperture, pulsed-power, and mechanical constraints combine to determine a coupled design solution. Multi-turn tracking confirms that candidate NLK locations maintain sufficient stay-clear (aperture-clearance) margin, while the optimized wire geometry reduces the required current and Lorentz force load. The results establish a unified approach for NLK-assisted injection design and provide a practical pathway for upgrades in diffraction-limited storage rings.

36 MATERIALS SCIENCE

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W

High‐Loading Lithium‐Sulfur Batteries with Solvent‐Free Dry‐Electrode Processing

Abstract Lithium‐sulfur (Li‐S) batteries, with their high energy density, nontoxicity, and the natural abundance of sulfur, hold immense potential as the next‐generation energy storage technology. To maximize the actual energy density of the Li‐S batteries for practical applications, it is crucial to escalate the areal capacity of the sulfur cathode by fabricating an electrode with high sulfur loading. Herein, ultra‐high sulfur loading (up to 12 mg cm −2 ) cathodes are fabricated through an industrially viable and sustainable solvent‐free dry‐processing method that utilizes a polytetrafluoroethylene binder fibrillation. Due to its low porosity cathode architecture formed by the binder fibrillation process, the dry‐processed electrodes exhibit a relatively lower initial capacity compared to the slurry‐processed electrode. However, its mechanical stability is well maintained throughout the cycling without the formation of electrode cracking, demonstrating significantly superior cycling stability. Additionally, through the optimization of the dry‐processing, a single‐layer pouch cell with a loading of 9 mg cm −2 and a novel multi‐layer pouch cell that uses an aluminum mesh as its current collector with a total loading of 14 mg cm −2 are introduced. To address the reduced initial capacity of dry‐processed electrodes, strategies such as incorporating electrocatalysts or employing prelithiated active materials are suggested.

Chemistry

Field Validation of a Grid-Interactive Efficient Building Software Solution

The U.S. General Services Administration's (GSA's) Green Proving Ground (GPG) program, in partnership with the National Laboratory of the Rockies (NLR), completed a field study of a Grid-Interactive Efficient Buildings (GEB) software solution. The study focused on a single testbed facility to test the GEB functionality of the software solution, along with other features. The testbed facility - a courthouse - is a common building type in GSA's vast building portfolio, offering potentially impactful findings on a scalable level. The study evaluated Prescriptive Data's technology, Nantum OS, a connected building operating system ("GEB Solution") which aggregates multiple sources of previously siloed building data and combines that data with external sources, such as weather information or utility signals, into a single integrated platform. A GEB Solution is a type of Energy Management Information System (EMIS). EMIS is defined as a system of devices, data services, and software applications that communicates with any building system or third-party data source to aggregate and transform data into new capabilities to aid in the optimization of energy use at the building, campus, or agency level. This specific GEB Solution is an EMIS with ASO, automated system optimization, offering supervisory control of certain aspects of the Building Automation System (BAS). Multiple features were evaluated including, but not limited to, Continuous Demand Management to avoid setting new monthly kilowatt (kW) peaks, energy efficiency for reduction of kilowatt hours (kWh) and natural gas consumption, and automated demand response (ADR) for purposes of lowering demand during a utility called Demand Response (DR) event. The testbed facility was the Foley Federal Building and US Courthouse ("Foley Federal Building") located in Las Vegas, NV. This is a 209,496 sq. ft. building constructed in the 1960s with major renovations in 2004. The facility was a good candidate due to the large prevalence of office and courthouse spaces in the GSA portfolio of buildings. It also has many features which allow integration into and control of the building and a strong facilities team to assist with the study. Quantitative and qualitative performance objectives were developed using GSA's GPG GEB project template along with input from the vendor and building facility staff; these are outlined in Table 1. The quantitative performance objectives focused on continuous demand management, energy efficiency, and automated demand response. The qualitative performance objectives focused on the ease of installation and commissioning as well as the operability of the GEB solution. Other performance metrics that are reported on include carbon reduction, cost effectiveness, and occupant acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A simplified di-homodyne transient grating spectroscopy system utilizing polarization

Here, a modification to the di-homodyne transient grating spectroscopy optical arrangement is presented that removes the need to individually align two spatially separated probe laser beams. This work details the novel application of a single probe beam that utilizes birefringent materials to produce two optically homodyned signals with a relative phase shift of π radians. This arrangement effectively simplifies the alignment to one probe beam and removes the relative phase shift ambiguity between each homodyned signal. Several example measurements for tungsten, titanium, molybdenum, and silicon are shown to illustrate the utility of the new optical system.

Simmonds, M. J. [Univ. of California, San Diego, C