Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low Leakage Valves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Advanced technology for space shuttle auxiliary propellant valves

Valves for the gaseous hydrogen/gaseous oxygen shuttle auxiliary propulsion system are required to feature low leakage over a wide temperature range coupled with high cycle life, long term compatibility and minimum maintenance. In addition, those valves used as thruster shutoff valves must feature fast response characteristics to achieve small, repeatable minimum impulse bits. These valve technology problems are solved by developing unique valve components such as sealing closures, guidance devices, and actuation means and by demonstrating two prototype valve concepts. One of the prototype valves is cycled over one million cycles without exceeding a leakage rate of 27 scc's per hour at 450 psia helium inlet pressure throughout the cycling program.

Wichmann, H.↗

High-pressure, low temperature electrical connector makes no-leak seal

Flow control of cryogenic liquids is achieved through use of an electrical feed-through connector with a solenoid-type valve. To prevent gas leakage, the connector is designed and structured so that extremely high pressure and low temperatures contribute to its sealing properties.

Weakley, J. F.↗

Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters

It is advantageous for gas-fed pulsed electric thrusters to employ pulsed valves so propellant is only flowing to the device during operation. The propellant utilization of the thruster will be maximized when all the gas injected into the thruster is acted upon by the fields produced by the electrical pulse. Gas that is injected too early will diffuse away from the thruster before the electrical pulse can act to accelerate the propellant. Gas that is injected too late will miss being accelerated by the already-completed electrical pulse. As a consequence, the valve must open quickly and close equally quickly, only remaining open for a short duration. In addition, the valve must have only a small amount of volume between the sealing body and the thruster so the front and back ends of the pulse are as coincident as possible with the valve cycling, with very little latent propellant remaining in the feed lines after the valve is closed. For a real mission of interest, a pulsed thruster can be expected to pulse at least 10(exp 10) - 10(exp 11) times, setting the range for the number of times a valve must open and close. The valves described in this paper have been fabricated and tested for operation in an inductive pulsed plasma thruster (IPPT) for in-space propulsion. In general, an IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged, producing a high-current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed, it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. The valve characteristics needed for the IPPT application require a fast-acting valve capable of a minimum of 10(exp 10) valve actuation cycles. Since even 10(exp 9) cycles is well above anything demonstrated, this lower value was selected as the design point for the present work. The valve seal must remain leak-tight throughout operation, and the body must maintain a low internal leakage at relatively high operating temperatures. The full set of design requirements used for this program are summarized in Table 1. In this work, we describe two pulsed gas valves that have been fabricated to have long lifetime and demonstrate the characteristics listed above. The first is a miniaturized, conventional electromagnet-based valve while the second is a piezoelectric-based valve design. The conventional valve, shown in Fig. 1, is opened by use of a solenoid electromagnetic actuator. When current is applied to the solenoid coil, magnetic forces pull the plunger away from the valve seat, allowing fluid to flow through the valve. Removal of electrical current permits the spring and fluid pressure to seat the plunger, halting the flow of fluid. The valve body is fabricated from 304L corrosion resistant steel (CRES) and while the parts that form the magnetic circuit are fabricated from 430 CRES. This material does not have optimum magnetic properties, but its corrosion resistance permits incorporation into a design without requiring an additional plating process. A viton O-ring compound (Parker V0884-75), selected for its mechanical strength at elevated temperatures, was used for the valve seat seal. The design was based solely on the use of analytical sizing calculations, as opposed to a more rigorous finite element analysis. While this valve is small and relatively lightweight, it does not represent a design that is optimized for mass and/or a given volume envelope. The piezoelectric valve is a "puller" valve design. Applying a voltage to the piezo crystal causes it to elongate and pull a pintle off the seat, opening the valve. The valve seal consists of the pintle with an external, spherically-formed tip fabricated from Inconel 625 and the seat fabricated from Inconel 718 and possessing a spherical surface that permits the pintle to align with the valve body centerline after each cycle, maintaining the circumferential metal-on-metal seal. The contact stress on the valve pintle is expected in the worst case to be 96.5 MPa (14 ksi), which is well below the work hardening value of 413.7 MPa (60 ksi) for Inconel 615. Results presented in this work will compare the performance of each valve, both to each other and to the valve design requirements given in Table 1. In general, both valves meet all the performance envelope requirements, but the piezoelectric valve consumes considerably less power and has a faster response time over the conventional solenoid-driven valves.

Burkhardt, Wendel M.↗

Self-aligning, low-pressure sealing poppet valve

Design and characteristics of poppet valve operated by very low differential pressures to control fluid flow are described. Valve is used to control flow of petroleum, chemical, and aircraft hydraulics where low leakage rates and activation at low pressures are required.

Gonzalez, R.↗

Cryogenic Fluid Management Technology and Nuclear Thermal Propulsion

Cryogenic fluid management (CFM) is critical to the success of future nuclear thermal propulsion powered vehicles. While this is an issue for any propulsion system utilizing cryogenic propellants, this is made more challenging by the radiation flux produced by the reactor in a nuclear thermal rocket (NTR). Managing the cryogenic fuel to prevent propellant loss to boil off and leakage is needed to limit the required quantity of propellant to a reasonable level. Analysis shows deposition of energy into liquid hydrogen fuel tanks in the vicinity of the nuclear thermal engine. This is on top of ambient environment sources of heat. Investments in cryogenic/thermal management systems (some of which are ongoing at various organizations) are needed in parallel to nuclear thermal engine development in order to one day see the successful operation of an entire stage. High durability, low thermal conductivity insulation is one developmental need. Light weight cryocoolers capable of removing heat from large fluid volumes at temperatures as low as approx. 20 K are needed to remove heat leak from the propellant of an NTR. Valve leakage is an additional CFM issue of great importance. Leakage rates of state of the art, launch vehicle size valves (which is approximately the size valves needed for a Mars transfer vehicle) are quite high and would result in large quantities of lost propellant over a long duration mission. Additionally, the liquid acquisition system inside the propellant tank must deliver properly conditioned propellant to the feed line for successful engine operation and avoid intake of warm or gaseous propellant. Analysis of the thermal environment and the CFM technology development are discussed in the accompanying presentation.

Taylor, Brian D.↗

Advanced technology for Space Shuttle Auxiliary Propellant Valves.

Propellant shutoff valves required for the operation of the pulse modulated gaseous hydrogen/gaseous oxygen rocket engines for the Space Shuttle Auxiliary Propulsion System are specified to operate for one million cycles over a ten-year period with zero maintenance, very fast response, very low leakage, and over a wide temperature range. Based on an analytical leakage and wear model, sealing configurations were conceived, sized, and developed. Two prototype valves featuring different components were designed, built, and evaluated for 100,000 cycles. Design concepts and test results are presented.

Wichmann, H.↗

A Historical Systems Study of Liquid Rocket Engine Throttling Capabilities

This is a comprehensive systems study to examine and evaluate throttling capabilities of liquid rocket engines. The focus of this study is on engine components, and how the interactions of these components are considered for throttling applications. First, an assessment of space mission requirements is performed to determine what applications require engine throttling. A background on liquid rocket engine throttling is provided, along with the basic equations that are used to predict performance. Three engines are discussed that have successfully demonstrated throttling. Next, the engine system is broken down into components to discuss special considerations that need to be made for engine throttling. This study focuses on liquid rocket engines that have demonstrated operational capability on American space launch vehicles, starting with the Apollo vehicle engines and ending with current technology demonstrations. Both deep throttling and shallow throttling engines are discussed. Boost and sustainer engines have demonstrated throttling from 17% to 100% thrust, while upper stage and lunar lander engines have demonstrated throttling in excess of 10% to 100% thrust. The key difficulty in throttling liquid rocket engines is maintaining an adequate pressure drop across the injector, which is necessary to provide propellant atomization and mixing. For the combustion chamber, cooling can be an issue at low thrust levels. For turbomachinery, the primary considerations are to avoid cavitation, stall, surge, and to consider bearing leakage flows, rotordynamics, and structural dynamics. For valves, it is necessary to design valves and actuators that can achieve accurate flow control at all thrust levels. It is also important to assess the amount of nozzle flow separation that can be tolerated at low thrust levels for ground testing.

Betts, Erin M.↗

Impulsive Injection for Compressor Stator Separation Control

Flow control using impulsive injection from the suction surface of a stator vane has been applied in a low speed axial compressor. Impulsive injection is shown to significantly reduce separation relative to steady injection for vanes that were induced to separate by an increase in vane stagger angle of 4 degrees. Injected flow was applied to the airfoil suction surface using spanwise slots pitched in the streamwise direction. Injection was limited to the near-hub region, from 10 to 36 percent of span, to affect the dominant loss due to hub leakage flow. Actuation was provided externally using high-speed solenoid valves closely coupled to the vane tip. Variations in injected mass, frequency, and duty cycle are explored. The local corrected total pressure loss across the vane at the lower span region was reduced by over 20 percent. Additionally, low momentum fluid migrating from the hub region toward the tip was effectively suppressed resulting in an overall benefit which reduced corrected area averaged loss through the passage by 4 percent. The injection mass fraction used for impulsive actuation was typically less than 0.1 percent of the compressor through flow.

Culley, Dennis E.↗

Liquid Nitrogen (Oxygen Simulent) Thermodynamic Venting System Test Data Analysis

In designing systems for the long-term storage of cryogens in low gravity space environments, one must consider the effects of thermal stratification on excessive tank pressure that will occur due to environmental heat leakage. During low gravity operations, a Thermodynamic Venting System (TVS) concept is expected to maintain tank pressure without propellant resettling. The TVS consists of a recirculation pump, Joule-Thomson (J-T) expansion valve, and a parallel flow concentric tube heat exchanger combined with a longitudinal spray bar. Using a small amount of liquid extracted by the pump and passing it though the J-T valve, then through the heat exchanger, the bulk liquid and ullage are cooled, resulting in lower tank pressure. A series of TVS tests were conducted at the Marshall Space Flight Center using liquid nitrogen as a liquid oxygen simulant. The tests were performed at fill levels of 90%, 50%, and 25% with gaseous nitrogen and helium pressurants, and with a tank pressure control band of 7 kPa. A transient one-dimensional model of the TVS is used to analyze the data. The code is comprised of four models for the heat exchanger, the spray manifold and injector tubes, the recirculation pump, and the tank. The TVS model predicted ullage pressure and temperature and bulk liquid saturation pressure and temperature are compared with data. Details of predictions and comparisons with test data regarding pressure rise and collapse rates will be presented in the final paper.

Hedayat, A.↗

An evaluation of a quick release fluid coupling having identical mating halves

A new quick disconnect fluid coupling features identical halves that provide male/female mating. Advantages are reduction of inventory and renewal of defective seals without installing new ones. Two designs were evaluated: A hermaphroditic connector (coupling half converts from one sex to another), and a nonconvertible coupling using a face or but type coupling- to-coupling seal. The hermaphroditic coupling was found superior. Advantages are (1) fewer seals used, reducing leakage, and (2) defective seals quickly replaced by simply converting both halves from one sex to another. Seals are standard O-rings and protected against contamination. The contributing factors to a low manufacturing cost are the shutoff valve and latching method.

Coupling↗

Space shuttle prototype check valve development

Contaminant-resistant seal designs and a dynamically stable prototype check valve for the orbital maneuvering and reaction control helium pressurization systems of the space shuttle were developed. Polymer and carbide seal models were designed and tested. Perfluoroelastomers compatible with N2O4 and N2H4 types were evaluated and compared with Teflon in flat and captive seal models. Low load sealing and contamination resistance tests demonstrated cutter seal superiority over polymer seals. Ceramic and carbide materials were evaluated for N2O4 service using exposure to RFNA as a worst case screen; chemically vapor deposited tungsten carbide was shown to be impervious to the acid after 6 months immersion. A unique carbide shell poppet/cutter seat check valve was designed and tested to demonstrate low cracking pressure ( 2.0 psid), dynamic stability under all test bench flow conditions, contamination resistance (0.001 inch CRES wires cut with 1.5 pound seat load) and long life of 100,000 cycles (leakage 1.0 scc/hr helium from 0.1 to 400 psig).

Tellier, G. F.↗

Long life, low cost ball valve, with lifted seals and cartridge type construction

Ball valve design incorporates modular construction in easy-to-install, easy-to-replace cartridge housing, and a system of cams to lift upstream and downstream seals away from the ball during rotation. Tests conducted on nitrogen tetroxide prove new valve to be more efficient than previous models in preventing leakage.

Carriker, J. W.↗

Cryogenic Transport of High-Pressure-System Recharge Gas

A method of relatively safe, compact, efficient recharging of a high-pressure room-temperature gas supply has been proposed. In this method, the gas would be liquefied at the source for transport as a cryogenic fluid at or slightly above atmospheric pressure. Upon reaching the destination, a simple heating/expansion process would be used to (1) convert the transported cryogenic fluid to the room-temperature, high-pressure gaseous form in which it is intended to be utilized and (2) transfer the resulting gas to the storage tank of the system to be recharged. In conventional practice for recharging high-pressure-gas systems, gases are transported at room temperature in high-pressure tanks. For recharging a given system to a specified pressure, a transport tank must contain the recharge gas at a much higher pressure. At the destination, the transport tank is connected to the system storage tank to be recharged, and the pressures in the transport tank and the system storage tank are allowed to equalize. One major disadvantage of the conventional approach is that the high transport pressure poses a hazard. Another disadvantage is the waste of a significant amount of recharge gas. Because the transport tank is disconnected from the system storage tank when it is at the specified system recharge pressure, the transport tank still contains a significant amount of recharge gas (typically on the order of half of the amount transported) that cannot be used. In the proposed method, the cryogenic fluid would be transported in a suitably thermally insulated tank that would be capable of withstanding the recharge pressure of the destination tank. The tank would be equipped with quick-disconnect fluid-transfer fittings and with a low-power electric heater (which would not be used during transport). In preparation for transport, a relief valve would be attached via one of the quick-disconnect fittings (see figure). During transport, the interior of the tank would be kept at a near-ambient pressure far below the recharge pressure. As leakage of heat into the tank caused vaporization of the cryogenic fluid, the resulting gas would be vented through the relief valve, which would be set to maintain the pressure in the tank at the transport value. Inasmuch as the density of a cryogenic fluid at atmospheric pressure greatly exceeds that of the corresponding gas in a practical high-pressure tank at room temperature, a tank for transporting a given mass of gas according to the proposed method could be smaller (and, hence, less massive) than is a tank needed for transporting the same mass of gas according to the conventional method.

Ungar, Eugene K,↗

Larger-Stroke Piezoelectrically Actuated Microvalve

A proposed normally-closed microvalve would contain a piezoelectric bending actuator instead of a piezoelectric linear actuator like that of the microvalve described in the preceding article. Whereas the stroke of the linear actuator of the preceding article would be limited to approximately equal to 6 micrometers, the stroke of the proposed bending actuator would lie in the approximate range of 10 to 15 micrometers-large enough to enable the microvalve to handle a variety of liquids containing suspended particles having sizes up to 10 m. Such particulate-laden liquids occur in a variety of microfluidic systems, one example being a system that sorts cells or large biomolecules for analysis. In comparison with the linear actuator of the preceding article, the bending actuator would be smaller and less massive. The combination of increased stroke, smaller mass, and smaller volume would be obtained at the cost of decreased actuation force: The proposed actuator would generate a force in the approximate range of 1 to 4 N, the exact amount depending on operating conditions and details of design. This level of actuation force would be too low to enable the valve to handle a fluid at the high pressure level mentioned in the preceding article. The proposal encompasses two alternative designs one featuring a miniature piezoelectric bimorph actuator and one featuring a thick-film unimorph piezoelectric actuator (see figure). In either version, the valve would consume a power of only 0.01 W when actuated at a frequency of 100 Hz. Also, in either version, it would be necessary to attach a soft elastomeric sealing ring to the valve seat so that any particles that settle on the seat would be pushed deep into the elastomeric material to prevent or reduce leakage. The overall dimensions of the bimorph version would be 7 by 7 by 1 mm. The actuator in this version would generate a force of 1 N and a stroke of 10 m at an applied potential of 150 V. The actuation force would be sufficient to enable the valve to handle a fluid pressurized up to about 50 psi (approximately equal to 0.35 MPa). The overall dimensions of the unimorph version would be 2 by 2 by 0.5 mm. In this version, an electric field across the piezoelectric film on a diaphragm would cause the film to pull on, and thereby bend, the diaphragm. At an applied potential of 20 V, the actuator in this version would generate a stroke of 10 micrometers and a force of 0.01 N. This force level would be too low to enable handling of fluids at pressures comparable to those of the bimorph version. This version would be useful primarily in microfluidic and nanofluidic applications that involve extremely low differential pressures and in which there are requirements for extreme miniaturization of valves. Examples of such applications include liquid chromatography and sequencing of deoxyribonucleic acid.

Yang, Eui-Hyeok↗

Spacecraft disinfectant/cleansing agent development

The sanitation agent container, which was selected in a trade off study, employs two chambers, a rigid outer container and an inner flexible bladder. The bladder contains the sanitation agent formulation and its release is controlled by a manually operated valve. The outer container holds a high pressure vapor. There is no void in the bladder which makes the package operation independent of orientation and therefore usable in zero gravity. Foam is developed by a low boiling point fluid or dissolved in the product. When the product is dispensed at atmospheric presure, the evolved gas or vapor whips up a goam in the valve. The sanitation agents were initially formulated with freons which produces an excellent foam. However freon is incompatible with the life support system and was replaced with carbon dioxide dissolved at high pressure. The CO2 system may limit high temperature exposure to prevent leakage or package distortion. The sanitation agents have been shown to be effective in cleaning soils from personnel and material.

Abbate, M.↗

Experimental Validation of Subsystem Models for a Novel Variable Displacement Hydraulic Motor

A novel, variable displacement, low-speed high-torque hydraulic motor is being developed that is expected to be highly efficient across a broad operating range. To ensure the final hardware achieves the expected performance, the models used in the development of the motor must be experimentally validated and revised, as necessary. The specific focus in this work is on mechanical energy loss models that were used to guide the design of a single-cylinder motor prototype and on experimental tests used for model validation. Ideally each model, whether friction loss in a piston/cylinder interface or energy loss due to leakage in a valve , would be individually validated by an independent test. This granular approach would remove any question of where the error lies and result in highly accurate models. However, many motor components have multiple forms of energy loss, creating difficulty in validating individual losses. Additionally, it is not physically realizable to divide many components into an individual model equivalent test. Testing the motor as a full assembly is possible, but pinpointing the source of discrepancies between the model and the hardware becomes difficult with dozens of models potentially being partially responsible. A compromise was found by separating the motor into functional component groups that are characterized by the type of loss and ability to test each subcomponent independently. By checking for correlation between test observations and model predictions, revisions could be implemented into the models. This allows future solutions to be more accurately predicted in the design phase to drive the design of better machines.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Columbus IFHX Ammonia Leak Analysis

After the Columbus Moderate Temperature Loop (MTL) InterFace Heat eXchanger (IFHX) low temperature event of GMT 345-2013, NASA investigated relevant transient scenarios involving IFHX rupture after water freezing and subsequent thawing. NASA recommended development of a Fault Detection Isolation and Recovery (FDIR) plan that would, in the event of a heat exchanger freeze event, close the Water On/Off Valves (WOOVs) to isolate the heat exchanger and prevent ammonia from the external flow loops from spreading into the cabin. NASA performed a preliminary simplified analysis for the reference case of IFHX rupture, but for a deeper understanding TAS developed detailed SINDA-FLUINT models of the Columbus ITCS that were built and run through the SINAPS GUI. This allowed simulation of the ammonia leakage physics including the variation of environmental parameters, thus providing more accurate and specific input to the FDIR under development. The result was finalization of the IFHX WOOVs closure sequence and wait times to contain the ammonia propagation to Columbus and allow identification of the leaking IFHX. In addition, the analysis results provided reference pressure profiles to be used on console and by the Engineering as support for the telemetry data assessment in case of failure.This paper gives an overview on the issue and focuses on the analytical aspects of the multiphase fluid dynamics involved.

Tilloca, A.↗

Design of a High-Pressure Fuel System for Use with Dimethyl Ether

The paper documents the modeling and experimental work on a common rail fuel injection system for Dimethyl Ether, a potential diesel substitute with a low carbon intensity signature. The DME fuel system is deployed on a light duty 2.2L compression ignition engine. The paper describes the injector optimization to shift to higher flows to account for the lower heating value and density of the DME when compared to diesel. The type of the injection system used for the DME application is an advanced rendering of the Common rail noted for a one-piece piston-needle injector construction and a solenoid driven spill valve featuring a pressure balanced poppet. A dedicated high-pressure fuel pump designed to pressurize DME is used. The design results in a fast acting open and close injection event, reduced leakage, with reduced cavitation in the fuel injector volume. Design parameters for system optimization included fill and spill orifices, needle lift, bias spring, and injector hole size. The design model provides good correlation of the instantaneous rates of injection with experiments across a wide range of pressure and injection timings. Proposed performance milestones for the design included similar DME injection duration to the diesel counterpart for same fuel energy injected into the cylinder to retain high engine cycle efficiency. Here, the dedicated DME design provided reduced hydraulic delays of 50%. Tests demonstrated sustained operation at pressures of 1000 bar, with capability to reach 1500bar. Durability tests showed no cavitation-deterioration over a 200-hour test cycle by means of spray imaging and hardware inspection.

De Ojeda, William [WM International Engineering, L↗