Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low Power Mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An 85 nW IoT Node-Controlling SoC for MELs Power-Mode Management and Phantom Energy Reduction

This paper presents an ultra-low power (ULP) node-controlling system-on-chip (SoC) used for power-mode management and phantom energy reduction of miscellaneous electric loads (MELs). The SoC is powered from a single 2.5 V voltage supply enabled by the integrated power management unit (PMU) and can control up to 16 MELs due to the on-chip 16-channel correlator and the 32b RISC-V microprocessor. To further reduce the system power consumption, two clock domains have been adopted for the correlator and the processor separately. Fabricated in 65-nm CMOS, the measured minimum power consumption of the proposed SoC is only 85 nW at 0.45 V voltage supply and 1 kHz clock frequency. The measured maximum operating frequency can go up to 148 kHz with a 0.55 V supply. An application experiment successfully demonstrates that the SoC controls the power modes of MELs from wake-up to cut-off to save the average power and phantom energy.

power-mode management, phantom energy, phantom pow↗

Small-Signal Stability Constrained Optimal Power Flow of Inverter-Dominated Power Systems with Flexible Operation Mode Selection

Given the intermittence and low inertia nature of inverter-based resources (IBRs), modern power systems with high penetration of IBRs challenge the conventional optimal power flow (OPF) analysis and the system may experience unexpected failures if stability constraints are not incorporated. This study proposes a small-signal stability-constrained OPF (SSSC-OPF) with flexible operation mode selection between grid-forming (GFM) and grid-following (GFL) modes for IBRs to address these challenges. The approach aims to maintain system stability with a sufficient stability margin while minimizing operation costs. The effectiveness of the proposed method is validated through extensive case studies on the IEEE 14-bus system. The results demonstrate that the proposed method is able to support system-level power flow analysis, reduce generation costs, and ensure stability under various disturbances.

grid-following↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On Projection of Safe Operation for Grid-Following Inverters - Grid Parameter Estimation

This work investigates the projection of safe operation for grid-following inverters using a reference model. This work applies recursive-least square and model reference adaptive estimation techniques to estimate the unknown grid parameters. The estimated grid parameters are used in a dynamic reference model to project the safe operation of the inverter. This work also demonstrates that the controller nonlinearity and parameter variations can cause unsafe operations, such as unexpected instability at low power levels, namely hidden mode of instability. This instability issue in the nominal operating range may occur for given control parameters in a weak-grid condition. The dynamic reference model for PQ-controlled inverters is applied to analyze this instability issue using the estimated grid parameters. Both adaptive identification techniques can estimate the unknown parameters accurately, and the dynamic reference model can safeguard inverters from an unsafe operation, i.e., hidden instability, by examining the incoming new power setpoints before engaging them to the local controller. The findings are experimentally verified using a small-scale two-level 208 V, 5 kVA inverter feeding a 12 kW NHR 9410 power grid emulator.

Hossen, Tareq↗

Dielectric Resonator Design for Low Power and Low Temperature Microwave Plasma

Waveguide-based microwave plasmas generally operate at high temperatures (2000 - 6000K)[1], making it difficult to directly interface solid materials with the plasma without significant thermal damage. Dielectric microwave resonators (DMRs), long studied for wave-based manipulation of electromagnetic radiation for telecom and optics, can focus radiation to extremely small mode volumes, creating intense localized fields with low-power input.[2] This phenomenon can be used for applications ranging from efficient plasma electronics to near-ambient plasma-materials interactions. Such DMR-based plasmas have been demonstrated a handful of times in the literature, but the majority of research towards this utilize the lowest frequency resonance mode.[3], [4], [5] By carefully controlling the geometry of cylindrical resonators, a variety of electromagnetic modes can be excited. In this work, COMSOL Multiphysics simulations are used to study the electric field enhancement and absorption properties of CaTiO3 DMRs as a function of geometry and excitation frequency. Whereas previous studies have utilized the HEM111 resonance frequency to drive low power plasma excitation, we find that higher order resonance frequencies are more effective at field enhancement and result in less power loss within the dielectric material, hence less wasted heating. The effectiveness of these modes is also geometry dependent and can be computationally optimized for plasma generation. Complementing these computational efforts, we demonstrate a new closed-system reactor design built in a WR-650 waveguide and experimentally demonstrate the formation of atmospheric argon microwave plasma using < 30 W input power on DMR dimers. We observe a shifting resonance frequency as the DMRs heat in response to microwave excitation and develop a Python-based lock-in mechanism to effectively track the DMR resonance over time, leading to stable plasma operation. We use infrared thermal imaging to monitor the temperature of the DMR dimers and surrounding quartz chamber, demonstrating thermal temperatures < 60 degreesC. Finally, we utilize optical emission spectroscopy (OES) to probe the plasma properties as a function of the resonance mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigations on the multiple-sector hard-copper X-band accelerating structures

The development of advanced, high gradient accelerating structures is one of the leading activity of the particle accelerator community. In the technological research of new construction methods for these devices, high-power testing is a critical step for the verification of their viability. Recent experiments showed that accelerating cavities made out of hard copper, fabricated without high-temperature processes, can achieve better performance as compared with soft copper ones. Recently, we have built cavities using Tungsten Inert Gas welding and the high-power experiments confirmed that this joining process is a robust and low-cost alternative to brazing or diffusion bonding. This is a good solution for high-gradient operation, with a gradient of about 150 MV/m in X-band, at a breakdown rate of 10 -3 /pulse/meter using a shaped RF pulse with a 150 ns flat part. We continue the design, construction and high power tests of three-cells standing-wave X-band accelerating cavities fabricated with a split-open geometry, made of hard copper and vacuum-sealed by welding. Our aim is the fabrication of accelerating structures made out of hard copper alloys by using innovative cost-effective technologies. Moreover, our method of multiple-sector structures opens the way to new technological approaches and design methods, for example providing the possibility of placing dampers of the parasitic higher-order modes. Such structures with dampers allow for acceleration of multi-bunch beams, both in standing and in travelling-wave accelerating modality. Here, this paper describes the design of two cavities made of multiple sectors that were fabricated at the Italian Institute for Nuclear Physics in Frascati, Italy (INFN-LNF), assembled by means of clamping and then joined with the Tungsten Inert Gas welding in order to preserve the hardness of the metal. These are three-cell standing-wave X-band accelerating cavities, to be operated in the π-mode. We report the low-power RF tests of the first one, made of two halves, and the RF design of the second one, made of four quadrants. Both structures were built for high-gradient tests at SLAC National Accelerator Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Powerful Terahertz Emission from a Bi 2 Sr 2 Ca Cu 2 O 8+ δ Mesa Operating Above 77 K

Mesa-shaped structures of the high critical temperature (high-T c ) superconductor Bi 2 Sr 2 CaCu 2 O 8+δ ; contain stacked intrinsic Josephson junctions. As such, they are a promising source of coherent radiation in the "terahertz gap" range, spanning from approximately 0.3 to 2.0 THz. Technological applications of these devices become far more practical if they can be operated at a cryogenic bath temperature of 77 K or higher. Previous works have reported emission from this type of device at high terahertz power levels at lower operating temperatures, 40-60 K, while at T bath >= 77 K observed power levels have generally been low. Here we report generation of 130 mu W of coherent power at 0.456 THz from a mesa of Bi 2 Sr 2 CaCu 2 O 8+δ ; doped with 0.16 holes per Cu atom, at a bath temperature of 77.4 K. Here, we find that the device radiates terahertz power when clearly identifiable cavity modes are excited, and that the frequency and bias voltage corresponding to each of these modes is almost independent of temperature. This is consistent with these modes having terahertz-frequency electric fields with very little dependence on vertical position within the mesa. We also find that the terahertz power radiated from any given mode decreases monotonically as the mesa temperature is increased. On the other hand, the low-frequency modes become inaccessible at low temperatures due to retrapping of the intrinsic Josephson junctions, and the maximum radiation power for the emitting mode is typically achieved at the temperature at which the retrapping voltage reaches the resonance voltage for this mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The role of isotope mass and transport for H-mode access in tritium containing plasmas at JET with ITER-like wall

The required heating power, $P_{\mathrm{LH}}$, to access the high confinement regime (H-mode) in tritium containing plasmas is investigated in JET with ITER-like wall at a toroidal magnetic field of $B_t = 1.8$ T and a plasma current of $I_p = 1.7$ MA. $P_{\mathrm{LH}}$, also referred to as the L-H power threshold, is determined in plasmas of pure tritium as well as mixtures of hydrogen with tritium (H-T) and mixtures of deuterium with tritium (D-T), and is compared to the L-H power threshold in plasmas of pure hydrogen and pure deuterium. It is found that, for otherwise constant parameters, $P_{\mathrm{LH}}$ is not the same in plasmas with the same effective isotope mass, $A_{\mathrm{eff}}$, when they differ in their isotope composition. Thus, $A_{\mathrm{eff}}$ is not sufficient to describe the isotope effect of $P_{\mathrm{LH}}$ in a consistent manner for all considered isotopes and isotope mixtures. The electron temperature profiles measured at the L-H transition in the outer half of the radius are very similar for all isotopes and isotope mixtures, despite the fact that the L-H power threshold varies by a factor of about six. This finding, together with the observation of an offset linear relation between the L-H power threshold, $P_{\mathrm{LH}}$, and an effective heat diffusivity, $\chi_{\mathrm{eff}}$, indicates that the composition-dependent heat transport in the low confinement mode (L-mode) determines, how much power is needed to reach the necessary electron temperatures at the edge, and hence $P_{\mathrm{LH}}$.

tritium plasmas↗

Grassy ELM regime at low pedestal collisionality in high-power tokamak plasma

Spontaneous mitigation of giant ELMs and appearance of grassy ELMs have been observed repeatedly at low pedestal collisionality (${\nu }_{\mathrm{e},\mathrm{p}\mathrm{e}\mathrm{d}}^{{\ast}}\sim 0.15$) in the high-power (P inj > 13 MW) hybrid scenario in DIII-D. Higher β p and higher q 95 appear to be beneficial to achieving the grassy ELM regime. The grassy ELM H-mode plasma shows high energy confinement performance (H 98y2 up to over 1.5) under the conditions of high neutral beam torque and high core rotation. The pedestal width appears to exceed the EPED1.0 model prediction by more than 50%. Pedestal stability analysis performed with the ELITE code indicates that the stability against low-n kink/peeling modes is improved with increased auxiliary heating power and the operational point in the grassy ELM regime is located near the ballooning boundary. The pedestal stability characteristics during the grassy ELM crashes have been investigated in comparison with the giant ELM crashes based on plasma profiles experimentally measured with high resolution and accuracy. It has been found that the underlying mechanism for the observed small-amplitude ELM crashes is mainly the expansion of the ballooning stability boundary induced by an initial radially localized collapse in the pedestal, which helps to stop the growth of instabilities and further collapse of the pedestal. The effect of electron density pedestal on mitigating edge localized instabilities has been analyzed by numerical simulation, suggesting that the electron density pedestal characterized by high n e,sep /n e,ped and low density gradient helps to stabilize peeling-ballooning modes because of a low pressure pedestal gradient and to lower the ballooning boundary mainly because of a low ion diamagnetic frequency in the pedestal region, thus triggering ballooning instabilities and producing the intrinsic grassy ELMs. Numerical simulation of the Chinese fusion engineering test reactor (CFETR) with the SOLPS code indicates that the separatrix density might be insensitive to the electron diffusivity in the pedestal region and increase with the power flowing from the core region to the edge region. Furthermore, pedestal stability analysis suggests that the flat density pedestal with high separatrix density obtained in the high-power plasma in CFETR would make the operational point close to the ballooning boundary, which is considered to help destabilize ballooning instabilities and facilitate the access to the grassy ELM regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D simulations of inertial confinement fusion implosions part 2: systematic flow anomalies and impact of low modes on performances in OMEGA experiments

We present the first 3D radiation-hydrodynamic simulations of directly driven inertial confinement fusion implosions with an inline package for polarized crossed-beam energy transfer, which were used to assess the impact of the current distributed polarization rotators (DPRs) on OMEGA as well as other known sources of asymmetry. Applied to OMEGA implosions, the simulations predict bang times with no need for ad hoc multipliers, as well as yields—if you separately account for the impacts of imprint and fuel age. The magnitude of the flow is well reproduced when the low mode sources are large, whereas the modeling of the stalk is thought to be required to match the flow magnitude in the remaining cases. For the cases explored in more detail, polarized cross-beam energy transfer (CBET)—the only known systematic drive asymmetry, brought the results closest to the measured flow vectors. The remaining discrepancies are shown to be stemming from the limited knowledge of the laser pointing modes. For typical current levels of beam mispointing, power imbalance, target offset, and asymmetry caused by polarized CBET, low modes degrade the yield by more than 40%. The current strategy of attempting to compensate the mode-1 asymmetry with a preimposed target offset recovers only about one-third of the losses caused by the low modes due to the dynamic nature of the multiple asymmetries and the presence of low modes other than l = 1. Furthermore, addressing the root causes of the drive asymmetries is apt to be more beneficial. To that end, one possible solution to the specific issue of polarized CBET (10 µm DPRs) is shown to work well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dependence of alpha-particle-driven Alfven eigenmode linear stability on device magnetic field strength and consequences for next-generation tokamaks

Recently-proposed tokamak concepts use magnetic fields up to 12 T, far higher than in conven- tional devices, to reduce size and cost. Theoretical and computational study of trends in plasma behavior with increasing field strength is critical to such proposed devices. This paper considers trends in Alfven eigenmode (AE) stability. Energetic particles, including alphas from D-T fusion, can destabilize AEs, possibly causing loss of alpha heat and damage to the device. AEs are sensitive to device magnetic field via the field dependence of resonances, alpha particle beta, and alpha orbit width. We describe the origin and effect of these dependences analytically and by using recently- developed numerical techniques (Rodrigues et al. 2015 Nucl. Fusion 55 083003). The work suggests high-field machines where fusion-born alphas are sub-Alfvenic or nearly sub-Alfvenic may partially cut off AE resonances, reducing growth rates of AEs and the energy of alphas interacting with them. High-field burning plasma regimes have non-negligible alpha particle beta and AE drive, but faster slowing down time, provided by high electron density, and higher field strength reduces this drive relative to low-field machines with similar power densities. The toroidal mode number of the most unstable modes will tend to be higher in high magnetic field devices. The work suggests that high magnetic field devices have unique, and potentially advantageous, AE instability properties at both low and high densities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First constraints on causal sources of primordial gravitational waves from BICEP/Keck, SPTpol, SPT-3G, Planck and WMAP $B$-mode data

Non-inflationary sources of gravitational waves in the early Universe generically predict causality-limited tensor power spectra at low frequencies. We report the first-ever constraints on such sources based on cosmic microwave background (CMB) $B$-mode polarization measurements. Using data from BICEP/Keck, SPTpol, SPT-3G, Planck, and WMAP, we constrain the amplitude of an early causal tensor (ECT) power spectrum parameterized by $r_{ect}$, the ratio of causal tensor power to total scalar power at $k~=~0.01$ Mpc$^{-1}$, and obtain a 95% CL upper limit of $r_{ect}<$ 0.0077. Since $r_{ect}$ can easily be related to the parameters of a given theory, our bound robustly constrains a broad class of well-motivated gravitational wave sources in the early universe, including first-order cosmological phase transitions, enhanced small-scale density perturbations, and various topological defects. Finally, we translate our limit into a bound on the present-day energy density in gravitational waves at ultra-low frequencies otherwise inaccessible to traditional gravitational wave detection strategies, including pulsar timing arrays, interferometers, and resonant cavities.

Zebrowski, Jessica A. [Fermilab; Chicago U., KICP]↗

A semi–automatic analytical methodology for characterizing the energy consumption of MRI systems using load duration curves

Background and purpose: Magnetic resonance imaging (MRI) scanners are a major contributor to greenhouse gas emissions from the healthcare sector, and efforts to improve energy efficiency and reduce energy consumption rely on quantification of the characteristics of energy consumption. The purpose of this work was to develop a semi-automatic analytical methodology for the characterization of the energy consumption of MRI systems using only the load duration curve (LDC). LDCs are a fundamental tool used across various fields to analyze and understand the behavior of loads over time. Methods: An electric current transformer sensor and data logger were installed on two 3T MRI scanners from two vendors, termed M1 (outpatient scanner) and M2 (inpatient/emergency scanner). Data was collected for 1 month (7/11/2023 to 8/11/2023). Active power was calculated, assuming a balanced three-phase system, using the average current measured across all three phases, a 480 V reference voltage for both machines, and vendor-provided power factors. An LDC was constructed for each system by sorting the active power values in descending order and computing the cumulative time (in units of percentage) for each data point. The first derivative of the LDC was then computed (LDC’), smoothed by convolution with a window function (sLDC’), and used to detect transitions between different system modes including (in descending power levels): scan, prepared-to-scan, idle, low-power, and off. The final, segmented LDC was used to measure time (% total time), total energy (kWh), and mean power (kW) for each system mode on both scanners. The method was validated by comparing mean power values, computed using the segmented 1-month LDC, for each nonproductive system mode (i.e., prepared-to-scan, idle, lower-power, and off) against power levels measured after a deliberate system shutdown was performed for each scanner (1 day worth of data). Results: The validation revealed differences in mean power values <1.4% for all nonproductive modes and both scanners. In the scan system mode, the mean power values ranged from 29.8 to 37.2 kW and the total energy consumed for 1 month ranged from 11 106 to 14 466 kWh depending on the scanner. Over the course of 1 month, the portion of time the scanners were in nonproductive modes ranged from 76% to 80% across scanners and the nonproductive energy consumption ranged from 8010 to 6722 kWh depending on the scanner. The M1 (outpatient) scanner consumed 99.9 and 183.9 kWh/day in idle mode for weekdays and weekends, respectively, because the scanner spent 23% more time proportionally in idle mode on the weekends. Conclusions: A semi-automatic method for quantifying energy consumption characteristics of MRI scanners was introduced and validated. This method is relatively simple to implement as it requires only power data from the scanners and avoids the technical challenges associated with extracting and processing scanner log files. Finally, the methodology enables quantitative evaluation of the power, time, and energy characteristics of MRI scanners in scan and nonproductive system modes, providing baseline data and the capability of identifying potential opportunities for enhancing the energy efficiency of MRI scanners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Applications of Solid-State Transformers for Electric Power Grid HEMP/GMD Resilience

A high-altitude electromagnetic pulse (HEMP) or geomagnetic disturbance (GMD) can disrupt power grids by inducing low-frequency common-mode (CM) currents. When these currents flow through grounded transformers, they can bias the magnetic core, driving it into saturation and reducing performance or damaging equipment. This work presents a solid-state transformer (SST) to replace vulnerable assets and improve grid resilience. The paper reviews half-cycle saturation in conventional transformers, then describes an SST architecture that neutralizes and redirects CM currents during HEMP/GMD events. A prototype SST is built and validated, demonstrating stable CM-disturbance operation and protection of nearby transformers. Finally, large-scale simulations show how coordinated SST deployment mitigates CM disturbances and strengthens overall grid resilience.

four-leg inverter↗

Physics-Based Feature Extraction from Bulk Time-Series PMU Datasets for Event Detection

In this work, two physics-based feature extraction techniques are developed for bulk time-series phasor measurement unit (PMU) datasets collected from the field to train the machine learning model for anomaly detection. Two approaches have been developed to extract useful features for different types of events. An admittance-based feature extraction technique is developed to detect events that involve line outages and system topology variations. The developed algorithm extracts the system equivalent admittance variation. Additionally, Fielder’s Theory is utilized to further reduce the potential computation burden by sectionalizing large-scale grids and datasets into smaller areas. Second, an oscillation-based feature extraction technique is developed to detect low-frequency oscillations in power grids. The dominant oscillation modes in the grids are extracted using energy-sorted Prony analysis. The extracted dominant oscillation modes by the developed work exhibit a high fitting resolution. Finally, the developed techniques have been validated using large-scale and real-world datasets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-resonant switched capacitor power converter architecture

A switched-capacitor (SC) network in an SC converter is controlled to operate at varying resonant modes to achieve high conversion ratio efficiency, at a low circuit component count. These power converters are suited to numerous application areas including improving energy efficiency of data centers. A family of resonant switched capacitor (SC) converters with multiple operating phases are presented “Multi-Resonant SC Converters”. Described in detail are an 8-to-1 Multi-Resonant-Doubler (MRD) converter and a 6-to-1 Cascaded Series-Parallel (CaSP). The topology of these converters make them amenable to combining like units in parallel toward reaching higher power levels.

Ye, Zichao↗