Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Study of magnetic reconnection at low- β using laser-powered capacitor coils

Magnetic reconnection is a ubiquitous fundamental process in space and astrophysical plasmas that rapidly converts magnetic energy into some combination of flow energy, thermal energy, and non-thermal energetic particles. Over the past decade, a new experimental platform has been developed to study magnetic reconnection using strong coil currents powered by high-power lasers at low plasma beta, typical conditions under which reconnection is energetically important in space and astrophysics. KJ-class lasers were used to drive parallel currents to reconnect MG-level magnetic fields in a quasi-axisymmetric geometry, similar to the magnetic reconnection experiment or MRX, and thus this platform is named micro-MRX. This presentation summarizes two major findings from micro-MRX: direct measurement of accelerated electrons and observation of ion acoustic waves during anti-parallel reconnection. The angular dependence of the measured electron energy spectrum and the resulting accelerated energies, supported by particle-in-cell simulations, indicate that direct acceleration by the out-of-plane reconnection electric field is at work. Furthermore, a sudden onset of ion acoustic bursts has been measured by collective Thomson scattering in the exhaust of magnetic reconnection, followed by electron acoustic bursts with electron heating and bulk acceleration. These results demonstrate that the micro-MRX platform offers a novel and unique approach to study magnetic reconnection in the laboratory in addition to the capabilities provided by traditional magnetized plasma experiments such as MRX and the upcoming Facility for Laboratory Reconnection experiments (FLARE). Future prospects to study other particle acceleration mechanisms and ion acoustic waves from magnetic reconnection are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Precise stellarator quasi-symmetry can be achieved with electromagnetic coils

Magnetic fields with quasi-symmetry are known to provide good confinement of charged particles and plasmas, but the extent to which quasi-symmetry can be achieved in practice has remained an open question. Recent work [M. Landreman and E. Paul, Phys. Rev. Lett. 128, 035001, 2022] reports the discovery of toroidal magnetic fields that are quasi-symmetric to orders-of-magnitude higher precision than previously known fields. We show that these fields can be accurately produced using electromagnetic coils of only moderate engineering complexity, that is, coils that have low curvature and that are sufficiently separated from each other. Our results demonstrate that these new quasi-symmetric fields are relevant for applications requiring the confinement of energetic charged particles for long time scales, such as nuclear fusion. The coils’ length plays an important role for how well the quasi-symmetric fields can be approximated. For the longest coil set considered and a mean field strength of 1 T, the departure from quasi-symmetry is of the order of Earth’s magnetic field. Additionally, we find that magnetic surfaces extend far outside the plasma boundary used by Landreman and Paul, providing confinement far from the core. Simulations confirm that the magnetic fields generated by the new coils confine particles with high kinetic energy substantially longer than previously known coil configurations. In particular, when scaled to a reactor, the best found configuration loses only 0.04% of energetic particles born at midradius when following guiding center trajectories for 200 ms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of Beam Coupling in the Marshall Magnetic Mirror Device

Experimental investigations of the coupling of an electron beam into a magnetically confined plasma have been undertaken at the Marshall Space Flight Center using the Marshall Magnetic Mirror (M3) system. The M3 system is composed of the following: two magnet coils; a cylindrical vacuum vessel; microwave source; and electron beam source. The magnet coils, which form the magnetic mirror, have an inner diameter of 25.4 cm and an outer diameter of 50.8 cm. The coils are composed of 9 coil segments with 33 turns in each segment. Each coil segment is connected in series. To create the target plasma, a 2 kW microwave source (2.45 gHz) is coupled into the vacuum chamber via waveguide. The electron beam source is a hollow cathode device created by the EPL Corporation. The hollow cathode is capable of producing a 50 amp beam with a pulse length of 1 second. It is also capable of continuous operation at 5 amps. The hollow cathode is mounted on one end of the cylindrical vacuum vessel 24 cm outside of a magnet coil. A current sensor is placed in the hollow cathode keeper bias circuit to measure emission current.

Schneider, T. A.↗

Potential damage to dc superconducting magnets due to high frequency electromagnetic waves

Studies of a d.c. superconducting magnet coil indicate that the large coil behaves as a straight waveguide structure. Voltages between layers within the coil sometimes exceeded those recorded at terminals where protective resistors are located. Protection of magnet coils against these excessive voltages could be accomplished by impedance matching throughout the coil system. The wave phenomenon associated with superconducting magnetic coils may create an instability capable of converting the energy of a quiescent d.c. superconducting coil into dissipative a.c. energy, even in cases when dielectric breakdown does not take place.

Gabriel, G. J.↗

(abstract) Electromagnetic Compatability Program to Accommodate a Spacecraft Magnetic Search Coil Experiment

A search coil is a very sensitive instrument that measures low frequency magnetic field radiation. In order for the search coil to achieve its objectives, an electromagnetic clean environment must be provided. On a spacecraft, there are many potential sources of low frequency magnetic field emitter. Consequently, a very stringent program is needed to control the emission from these sources. This paper describes the details of such a program.

systems electric motors enclosures shielding↗

Conductor on molded barrel magnet assembly and associated systems and methods

A Conductor on Molded Barrel (COMB) magnet assembly optimized for High Temperature Superconducting (HTS) materials. The magnet assembly comprises a magnetic coil(s) carried by a conductor support structure and configured in cosine-theta geometry. Created using additive manufacturing, the conductor support structure features a continuous cable channel that fittedly carries and positions elongated straight portion(s) of the magnetic coil(s) parallel to a magnetic axis. The conductor support structure may be cylindrically shaped and longitudinally bored, with the continuous cable channel comprising an outer channel portion (distal on the cylinder) and an inner channel portion (proximal on the cylinder). A transition hole that joins the outer channel portion and the inner channel portion allows a single magnetic coil to be wound along both the outer and inner surfaces of the conductor support structure. The conductor support structure may be fabricated as longitudinally-symmetrical halves, and secured for operation using azimuthal and/or midplane shims.

Kashikhin, Vadim V.↗

Use of current-potential patches to obtain fundamental improvements to the coils of magnetic fusion devices

A central issue in the design of tokamaks or stellarators is the coils that produce the external magnetic fields. The freedom that remains unstudied in the design of coils is enormous. This freedom could be quickly studied computationally at low cost with high reliability. In particular, the space between toroidal field and modular coils that blocks access to the plasma chamber could be increased by a large factor. The concept of current-potential patches, which was developed in Todd Elder's thesis, provides a method for separating the study of the feasibility of coils with attractive physics properties from the engineering design of specific coils. In addition to enhanced accessibility, coils can be designed for increased plasma-coil separation, insensitivity to coil position errors, and plasma control.

Boozer, Allen H. [Columbia Univ., New York, NY (Un↗

The development of a containment vessel and Dewar for the particle astrophysics magnet facility (ASTROMAG)

The ASTROMAG facility is the heart of a large charged particle detection and resolution system. ASTROMAG utilizes a superconducting magnet consisting of a large superconducting magnet coil with a stored magnetic energy of approximately 15 MJ. The active coil will have a mass of 1200 kg. This magnet will be cooled by a cryostat using a liquid helium Dewar for storage. The cryostat will have a series of gas-cooled shields with an external guard vacuum shield and an internal Dewar. The magnet and cryostat will be designed for shuttle or Delta launch and will be designed to withstand the internal pressure of expanded helium under full quench conditions when venting is prevented. The external guard vacuum shell is required to maintain a vacuum for Earth based testing and for cold launch of the cryostat and magnet. The magnet is designed to operate at 4.4 K with a peak field of 7.0 tesla. The superconducting material within the magnet is niobium titanium in a conductive matrix.

Source record↗

Signal Differentiation of Moving Magnetic Nanoparticles for Enhanced Biodetection and Diagnostics

Magnetic nanoparticles are extensively utilized as markers/signal labelling in various biomedical applications. Detecting and distinguishing magnetic signals from similarly sized moving magnetic nanoparticles in microfluidic systems is crucial yet challenging for biosensing. In this study, we have developed an original method to detect and differentiate magnetic signals from moving superparamagnetic (SPM) and ferrimagnetic (FM) nanoparticles of comparable sizes. Our approach utilizes a highly sensitive magnetic-coil-based sensor that harnesses the combined effects of giant magnetoimpedance (GMI) and an LC-resonance circuit, offering performance superior to that of conventional GMI sensors. Iron oxide nanoparticles, which have similar particle sizes but differing coercivities (zero for SPM and non-zero for FM) or similar zero coercivities but differing particle sizes, flow through the magnetic coil at controlled velocities. Their distinct effects are analyzed through changes in the complex impedance of the sensing system. Our findings provide a unique pathway for utilizing SPM and FM nanoparticles as innovative magnetic markers to identify specific biological entities, thereby expanding their potential applications.

Hwang, Kee Young↗

Magnetic field test coils are temperature compensated

Magnetic field test coils with auxiliary winding wound opposite to main coil winding eliminates changes in field configurations due to temperature changes. The auxiliary coil is made with aluminum wire.

Source record↗

Calculations enable optimum design of magnetic brake

Mathematical analysis and computations determine optimum magnetic coil configurations for a magnetic brake which controllably decelerates a free falling load to a soft stop. Calculations on unconventionally wound coils determine the required parameters for the desired deceleration with minimum electrical energy supplied to the stationary coil.

Kosmahl, H. G.↗

System and method for alfvenic reconnecting plasmoid plasma acceleration

According to various embodiments, a system for using magnetic reconnection to accelerate plasma is disclosed. The system includes a pair of electrodes including two concentric rings separated by an electrode gap and held at different electrostatic potential by applying a voltage to generate an inter-electrode electric field. The system further includes a plurality of magnetic coils configured to produce magnetic field lines that connect the pair of electrodes. The system additionally includes a gas injector configured to inject gas into the electrode gap, the injected gas being partially ionized by the inter-electrode electric field to generate a poloidal current that flows along open magnetic field lines across the electrode gap. A total Lorentz force causes oppositely directed magnetic field lines to be expanded around a region of the gas injector to further create an azimuthal current in the form of an axially elongated current sheet that is unstable such that the axially elongated current sheet reconnects and breaks into plasmoids.

Ebrahimi, Fatima Arezu↗