Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE COUPLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Nuclear magnetic resonance of Al-27 in topaz, Al2SiO4/F, OH/2.

The Al-27 nuclear quadrupolar coupling constant and asymmetry parameter (eta) in topaz have been determined to be 1.67 (plus or minus 0.03) MHz and 0.38 plus or minus 0.05, respectively. These values and the orientations of the principal axes are consistent with the Fe(3+) paramagnetic resonance data and with the symmetry of the AlO4F2 octahedron.

Tsang, T.↗

Ionospheric disturbances and gravity waves

The response of ionization to a gravity wave moving through the ionosphere is studied. Hydrodynamic equations are used, and local thermodynamic equilibrium is imposed for simplicity. The treatment involves a perturbation analysis, and the background medium is assumed to be time stationary, horizontally stratified, and known. It is shown that ionization may be locally resonant at each level for certain frequencies and directions, for which condition neutral and ionized particles are considered closely or critically coupled. The phase direction for this critical coupling is always downward in the absence of a magnetic field. A magnetic field results in two resonant directions for the same frequency, and these directions are mostly downward. Observed TID's associated with gravity waves may be indicative of such resonances. It is also noted that strong coupling may occur to neutral acoustic waves at high altitudes. Previous investigations restrict their use of momentum equations to the diffusion equation. The analysis also shows that such restrictions result in the neglect of terms arising from momentum transport due to any background ambipolar diffusion velocity and wave motion. These terms are mostly relevant at higher altitudes.

Eun, H.↗

Pc 3 magnetic pulsations and precipitation of energetic electrons

The synchronous altitude satellite ATS 1 data and near-conjugate measurements of bremsstrahlung X-rays and ground magnetic variations were used to analyze an event of modulated auroral zone electron precipitation and magnetic pulsations in the Pc range. Transverse, azimuthal, nearly linearly polarized waves observed at ATS 1, ground magnetic pulsations at College, Alaska, and intervals of modulated electron precipitation centered on local magnetic moon, and noted in the X-ray data from Fort Yukon, Alaska, are discussed, noting that the origin of the Pc 3 waves is attributed to local field line resonances induced by Kelvin-Helmholtz instability at the magnetopause. The wave resonance model can explain observed differences in the pulsation activity at the ground, balloon, and satellite if account is taken of the spatial sensitivities of the techniques and the location of observing sites with respect to the probable location of resonant field lines. The data suggest that electron precipitation pulsations will correlate with Pc 3 magnetic pulsations when substorm injections coupled with azimuthal drift provide enhanced energetic particle fluxes with dayside resonance regions.

Arthur, C. W.↗

Electron Drift Resonance in the MHD-Coupled Comprehensive Inner Magnetosphere-Ionosphere Model

Relativistic electrons in the outer radiation belt are highly dynamic and respond to interplanetary solar wind structures interacting with the Earth's magnetic field. A known mechanism dictating electron dynamics is the drift-resonant interaction with ultralow frequency (ULF) waves. The present work simulates the ring current and radiation belt electron populations in the bounce-averaged, kinetic Comprehensive Inner Magnetosphere-Ionosphere model coupled with the Block Adaptive Tree Solar Wind Roe-type Upwind Scheme global magnetospheric magnetohydrodynamic (MHD) code using an idealized ULF wave solar wind density driver. ULF waves generated with 10 min periods (at 1.67 mHz frequencies) in the MHD model are characterized and the corresponding energization of electrons and radial transport of electron phase space density is presented. The drift-resonant electron energy is determined in the simulation and is consistent with the electron resonance conditions in dipolar magnetic fields. The present results will be an important component of understanding inner magnetospheric dynamics and how these inner magnetospheric populations interact with ULF waves resulting from interplanetary solar wind structures.

Komar, C. M.↗

Ultraviolet line profiles of slowly rotating massive star winds using the ‘analytic dynamical magnetosphere’ formalism

Recent large-scale spectropolarimetric surveys have established that a small but significant percentage of massive stars host stable, surface dipolar magnetic fields with strengths on the order of kG. These fields channel the dense, radiatively driven stellar wind into circumstellar magnetospheres, whose density and velocity structure can be probed using ultraviolet (UV) spectroscopy of wind-sensitive resonance lines. Coupled with appropriate magnetosphere models, UV spectroscopy provides a valuable way to investigate the wind–field interaction, and can yield quantitative estimates of the wind parameters of magnetic massive stars. We report a systematic investigation of the formation of UV resonance lines in slowly rotating magnetic massive stars with dynamical magnetospheres. We pair the analytic dynamical magnetosphere (ADM) formalism with a simplified radiative transfer technique to produce synthetic UV line profiles. Using a grid of models, we examine the effect of magnetosphere size, the line strength parameter, and the cooling parameter on the structure and modulation of the line profile. We find that magnetic massive stars uniquely exhibit redshifted absorption at most viewing angles and magnetosphere sizes, and that significant changes to the shape and variation of the line profile with varying line strengths can be explained by examining the individual wind components described in the ADM formalism. Finally, we show that the cooling parameter has a negligible effect on the line profiles.

C Erba↗

A Collimated Retarding Potential Analyzer for the Study of Magnetoplasma Rocket Plumes

A gridded retarding potential analyzer (RPA) has been developed to characterize the magnetized plasma exhaust of the 10 kW Variable Specific Impulse Magnetoplasma Rocket (VX-10) experiment at NASA's Advanced Space Propulsion Laboratory. In this system, plasma is energized through coupling of radio frequency waves at the ion cyclotron resonance (ICR). The particles are subsequently accelerated in a magnetic nozzle to provide thrust. Downstream of the nozzle, the RPA's mounting assembly enables the detector to make complete axial and radial scans of the plasma. A multichannel collimator can be inserted into the RPA to remove ions with pitch angles greater than approximately 1 deg. A calculation of the general collimator transmission as a function over velocity space is presented, which shows the instrument's sensitivity in detecting changes in both the parallel and perpendicular components of the ion energy. Data from initial VX-10 ICRH experiments show evidence of ion heating.

Glover, T. W.↗

Three-wave coupling coefficient in a drifting bi-Maxwellian plasma

A general electrostatic coupling coefficient which satisfies the Manley-Rowe relations is used to derive an explicit expression for the resonant three-wave coupling coefficient between electrostatic normal modes of a uniformly magnetized, infinite, homogeneous plasma with species described by drifting bi-Maxwellian distribution functions. The limit of this expression is taken when the phase velocities of the three waves are much larger than a species thermal speed, and also when the phase velocities are much smaller than the thermal speed. These are fluid limits and are applicable to the three-wave interaction between some low-frequency electrostatic waves, such as ion acoustic and ion cyclotron modes, in a plasma where T(e) is much greater than T(i).

Bergmann, Rachelle↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Low field electron paramagnetic resonance imaging with SQUID detection

In one embodiment, a flux transformer with a gradiometer pickup coil is magnetically coupled to a SQUID, and a SQUID array amplifier comprising a plurality of SQUIDs, connected in series, is magnetically coupled to the output of the SQUID. Other embodiments are described and claimed.

Hahn, Inseob↗

Differential Resonant Ring YIG Tuned Oscillator

A differential SiGe oscillator circuit uses a resonant ring-oscillator topology in order to electronically tune the oscillator over multi-octave bandwidths. The oscillator s tuning is extremely linear, because the oscillator s frequency depends on the magnetic tuning of a YIG sphere, whose resonant frequency is equal to a fundamental constant times the DC magnetic field. This extremely simple circuit topology uses two coupling loops connecting a differential pair of SiGe bipolar transistors into a feedback configuration using a YIG tuned filter creating a closed-loop ring oscillator. SiGe device technology is used for this oscillator in order to keep the transistor s 1/f noise to an absolute minimum in order to achieve minimum RF phase noise. The single-end resonant ring oscillator currently has an advantage in fewer parts, but when the oscillation frequency is greater than 16 GHz, the package s parasitic behavior couples energy to the sphere and causes holes and poor phase noise performance. This is because the coupling to the YIG is extremely low, so that the oscillator operates at near the unloaded Q. With the differential resonant ring oscillator, the oscillation currents are just in the YIG coupling mechanisms. The phase noise is even better, and the physical size can be reduced to permit monolithic microwave integrated circuit oscillators. This invention is a YIG tuned oscillator circuit making use of a differential topology to simultaneously achieve an extremely broadband electronic tuning range and ultra-low phase noise. As a natural result of its differential circuit topology, all reactive elements, such as tuning stubs, which limit tuning bandwidth by contributing excessive open loop phase shift, have been eliminated. The differential oscillator s open-loop phase shift is associated with completely non-dispersive circuit elements such as the physical angle of the coupling loops, a differential loop crossover, and the high-frequency phase shift of the n-p-n transistors. At the input of the oscillator s feedback loop is a pair of differentially connected n-p-n SiGe transistors that provides extremely high gain, and because they are bulk-effect devices, extremely low 1/f noise (leading to ultralow RF phase noise). The 1/f corner frequency for n-p-n SiGe transistors is approximately 500 Hz. The RF energy from the transistor s collector output is connected directly to the top-coupling loop (the excitation loop) of a single-sphere YIG tuned filter. A uniform magnetic field to bias the YIG must be at a right angle to any vector associated with an RF current in a coupling loop in order for the precession to interact with the RF currents.

Parrott, Ronald A.↗

Theory of electrically controlled resonant tunneling spin devices

We report device concepts that exploit spin-orbit coupling for creating spin polarized current sources using nonmagnetic semiconductor resonant tunneling heterostructures, without external magnetic fields. The resonant interband tunneling psin filter exploits large valence band spin-orbit interaction to provide strong spin selectivity.

spin filters↗

The dynamics of charged particles in turbulent astrophysical plasmas

We consider the resonant interaction of energetic charged particles and transverse plasma wave propagating parallel and/or antiparallel to the uniform magnetic field B(sub 0) in an underlying background plasma of density n. The coupling of the plasma waves and the energetic particles will be controlled by the ratio n/(the absolute value of B(sub 0)(exp 2). A variation of this ratio leads to a strong variation of the dynamics of the energetic particles. By taking into account the whole transverse plasma branch for the resonant interaction we discuss the influence of the background plasma density, the background magnetic field, the cross helicity, and the magnetic helicities on the dynamics of charged particles in astrophysical plasmas. It is shown that low-energy electrons can be accelerated efficiently by the higher electromagnetic waves and short-wavelength whistlers for low values of the ratio n/(the absolute value of B(sub 0)(exp 2), which means for low values of the ratio of plasma frequency to gyrofrequency.

Dung, Rudiger↗

Self-consistent models for Coulomb heated X-ray pulsar atmospheres

Calculations of accreting magnetized neutron star atmospheres heated by the gradual deceleration of protons via Coulomb collisions are presented. Self consistent determinations of the temperature and density structure for different accretion rates are made by assuming hydrostatic equilibrium and energy balance, coupled with radiative transfer. The full radiative transfer in two polarizations, using magnetic cross sections but with cyclotron resonance effects treated approximately, is carried out in the inhomogeneous atmospheres.

Harding, A.↗

Self-consistent models for Coulomb-heated X-ray pulsar atmospheres

Calculations of accreting magnetized neutron star atmospheres heated by the gradual deceleration of Protons via Coulomb collisions are presented. Self consistent determinations of the temperature and density structure for different accretion rates are made by assuming hydrostatic equilibrium and energy balance, coupled with radiative transfer. The full radiative transfer in two polarizations, using magnetic cross sections but with cyclotron resonance effects treated approximately, is carried out in the inhomogeneous atmospheres. Previously announced in STAR as N84-12012

Harding, A. K.↗