Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Data for Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.f

Mass Spectrometry↗

A Novel Strategy for Numerical Simulation of High-speed Turbulent Reacting Flows

The objective of this research is to improve and implement the filtered mass density function (FDF) methodology for large eddy simulation (LES) of high-speed reacting turbulent flows. We have just completed Year 1 of this research. This is the Final Report on our activities during the period: January 1, 2003 to December 31, 2003. 2002. In the efforts during the past year, LES is conducted of the Sandia Flame D, which is a turbulent piloted nonpremixed methane jet flame. The subgrid scale (SGS) closure is based on the scalar filtered mass density function (SFMDF) methodology. The SFMDF is basically the mass weighted probability density function (PDF) of the SGS scalar quantities. For this flame (which exhibits little local extinction), a simple flamelet model is used to relate the instantaneous composition to the mixture fraction. The modelled SFMDF transport equation is solved by a hybrid finite-difference/Monte Carlo scheme.

Sheikhi, M. R. H.↗

Ion mass spectrometer for special uses

Prototype of curved-electrode, Paul-type, quadrupole, electrodynamic mass filter has the mass-resolution and transmission-factor properties expected from both theoretical considerations and results of experiments using linear quadrupole features.

Abramson, R. H.↗

Meta-Study of Particulate Detection Losses on Radioactive Air Sample Filters

Several mathematical relationships between air sample filter mass loading and the correlated analytical self-absorption factor were developed using data from other published research in this meta-study. Gross-alpha and -beta applications are addressed for this research. As filter media becomes loaded with particulate matter, there is potential for measurement losses due to self-absorption by mass loading. Components contributing to absorption include particulate dust, radioactive particulates, and filter material. Standards indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the detection rate by more than 5%. Previously, losses due to self-absorption have been reported up to 100% over a range up to ~10 mg∙cm -2 mass loading. These absorption losses then can be used to determine a correction factor for sample results. For low mass loadings (e.g., ≤0.1 mg∙cm -2 ) corrections factors in the 0.85 - 1 range have been recommended and used, while at higher mass loadings nearer to 10 mg∙cm -2 correction factors closer to 0 (representing near 100% losses) are used. Based on data from published studies, the different methods for relating percent loss due to self-absorption to mass loading include linear, exponential, quadratic, and trinomial derived functions. Where applicable, both forced zero and non-forced zero results were evaluated. From the derived functions evaluated, the trinomial function provided the best fit. Once the sample filter mass loading is known, the trinomial function can be applied to estimate losses and the corresponding self-absorption factor. When applied to routine operating conditions for radiological facility stacks monitored at the Pacific Northwest National Laboratory for an average sample filter mass loading of 0.09 ± 0.12 (2σ) mg∙cm -2 (excluding negative values and outliers) and a range from 0 - 0.24 mg∙cm -2 , the estimated trinomial function nominal self-absorption losses are less than 5% at 0.09 mg∙cm -2 and less than 10% at 0.24 mg∙cm -2 . The trinomial function is one method that may be used to adjust the activity results of an air sample when the sample-specific mass loading is determined. The application of no correction factor when the ANSI/HPS N13.1-2021 guidance of a 5% threshold for loss is not reached with typical stack sample mass loadings may be reasonable in high-efficiency particulate air filtered systems. For simplicity, it would be conservative in assigning the self-absorption correction factor at the 5% threshold (i.e., 0.95) for general uses but in cases of heavy mass loading to calculate the factor.

air sampling↗

Mass-selected ion–molecule cluster beam apparatus for ultrafast photofragmentation studies

We describe an apparatus for investigating the excited-state dissociation dynamics of mass-selected ion–molecule clusters by mass-resolving and detecting photofragment-ions and neutrals, in coincidence, using an ultrafast laser operating at high repetition rates. The apparatus comprises a source that generates ion–molecule clusters, a time-of-flight spectrometer, and a mass filter that selects the desired anions, and a linear-plus-quadratic reflectron mass spectrometer that discriminates the fragment anions after the femtosecond laser excites the clusters. The fragment neutrals and anions are then captured by two channeltron detectors. The apparatus performance is tested by measuring the photofragments: I – , CF 3 I – , and neutrals from photoexcitation of the ion–molecule cluster CF 3 I·I – using femtosecond UV laser pulses with a wavelength of 266 nm. Here, the experimental results are compared with our ground state and excited state electronic structure calculations as well as the existing results and calculations, with particular attention to the generation mechanism of the anion fragments and dissociation channels of the ion–molecule cluster CF 3 I·I – in the charge-transfer excited state.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Laboratory Automation of a Quadrupole Mass Spectrometer

Efforts directed toward interfacing an LSI II bus of a PDP 11/23 desktop computer with a quadrupole mass spectrometer for the purpose of providing a convenient system whereby mass spectral data, of the products of thermal decomposition, may be rapidly acquired and processed under programmed conditions are described. The versatility and operations of the quadrupole mass spectrometer are discussed as well as the procedure for configurating the LSI II bus of the PDP 11/23 desktop computer for interfacing with the quadrupole mass spectrometer system. Data from the mass filter and other units of the spectrometer are digitally transferred to the computer whereupon mass spectral data and related data are generated.

Thompson, J. M.↗

First Results From the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The Huygens Probe of the Cassini Huygens Mission entered the atmosphere of the moon Titan on January 14,2005. The GCMS was part of the instrument complement on the Probe to measure in situ the chemical composition of the atmosphere during the probe descent and to support the Aerosol Collector Pyrolyser (ACP) experiment by serving as detector for the pyrolization products. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns. The mass spectrometer employed five electron impact ion sources with available electron energies of either 70 or 25 eV. Three ion sources served as detectors for the GC columns and two were dedicated to direct atmosphere sampling and ACP gas sampling, respectively. The GCMS gas inlet was heated to prevent condensation, and served to evaporate surface constituents after impact.

Niemann, Hasso B.↗

Damped Ly α absorbers and atomic hydrogen in galaxies: the view of the GAEA model

ABSTRACT Using the GAEA semi-analytic model, we analyse the connection between Damped Ly α systems (DLAs) and H i in galaxies. Our state-of-the-art semi-analytic model is tuned to reproduce the local galaxy H i mass function, and that also reproduces other important galaxy properties, including the galaxy mass–gas metallicity relation. To produce catalogues of simulated DLAs we throw 105 random lines of sight in a composite simulated volume: dark matter haloes with log$(\frac{M_{200}}{ {\rm M}_{\odot }}) \ge 11.5$ are extracted from the Millennium Simulation, while for $9.2 \le \log (\frac{M_{200}}{ \mathrm{M}_{\odot }})\lt 11.5$ we use the Millennium II, and for $8 \le \log (\frac{M_{200}}{\mathrm{M}_{\odot }}) \lt 9.2$ a halo occupation distribution model. At 2 < z < 3, where observational data are more accurate, our fiducial model predicts the correct shape of the column density distribution function, but its normalization falls short of the observations, with the discrepancy increasing at higher redshift. The agreement with observations is significantly improved increasing both the H i masses and the disc radii of model galaxies by a factor of 2, as implemented ‘a posteriori’ in our 2M−2R model. In the redshift range of interest, haloes with $M_{200} \ge {10}^{11} \, \mathrm{M}_{\odot }$ give the major contribution to ΩDLA, and the typical DLA host halo mass is $\sim \!{10}^{11} \, \mathrm{M}_{\odot }$. The simulated DLA metallicity distribution is in relatively good agreement with observations, but our model predicts an excess of DLAs at low metallicities. Our results suggest possible improvements for the adopted modelling of the filtering mass and metal ejection in low-mass haloes.

Di Gioia, Serafina↗

The Laser Ablation Ion Funnel: Sampling for in situ Mass Spectrometry on Mars

A considerable investment has been made by NASA and other space agencies to develop instrumentation suitable for in situ analytical investigation of extra terrestrial bodies including various mass spectrometers (time-of-flight, quadrupole ion trap, quadrupole mass filters, etc.). However, the front-end sample handling that is needed to collect and prepare samples for interrogation by such instrumentation remains underdeveloped. Here we describe a novel approach tailored to the exploration of Mars where ions are created in the ambient atmosphere via laser ablation and then efficiently transported into a mass spectrometer for in situ analysis using an electrodynamic ion funnel. This concept would enable elemental and isotopic analysis of geological samples with the analysis of desorbed organic material a possibility as well. Such an instrument would be suitable for inclusion on all potential missions currently being considered such as the Mid-Range Rover, the Astrobiology Field Laboratory, and Mars Sample Return (i.e., as a sample pre-selection triage instrument), among others.

Johnson, Paul V.↗

MassIVE MSV000094084 - Data files for manuscript - Selected ion monitoring for orbitrap-based metabolomics: Please open README-data-for-SIM-paper-20240210.doc for details.

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage. Please open README-data-for-SIM-paper-20240210.doc for details. [doi:10.25345/C5JH3DD3K] [dataset license: CC0 1.0 Universal (CC0 1.0)]

Rabinowitz, Joshua↗

Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.

59 BASIC BIOLOGICAL SCIENCES↗

Martin Marietta atomic oxygen Low Earth Orbit (LEO) simulation

An atomic oxygen beam apparatus that produces flux levels and atomic kinetic energy similar to that encountered by spacecraft in low Earth orbit (LEO) is described. The beam apparatus consists of an electric discharge ion source, mass filter, decelerator, and neutralizer. Specific design goals include a 1.3 cm beam diameter, a 5 eV beam energy, and a flux density on the order of 10(15) cm(-2) s(-1). The total fluence will be on the order of 10(19) cm(-2) for an 8 hour test. The neutral oxygen beam will expose various materials contained within a large target chamber. Within the chamber will be a rather complex suite of instrumentation that will allow real-time studies of material mass loss and reactant species spatial distribution. In addition, a UV solar simulator will aid in the understanding of various synergistic effects.

Sjolander, Gary W.↗

Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The GCMS was part of the instrument complement on the Cassini-Huygens Probe to measure in situ the chemical composition of the atmosphere during the probe descent and coupled with the Aerosol Collector Pyrolyser (ACP) experiment by serving as detector for the pyrolization products to determine the composition of the aerosol particles. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of m/z from 2 to 141. The major constituents of the lower atmosphere were confirmed to be NP and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3 x 10(exp-5) and of Ar-36 is 2.8 x 10(exp -7). The other primordial noble gases were below mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3 x l0(exp -4). Carbon dioxide, ethane, acetylene and cyanogen were detected evaporating from the surface in addition to methane.

Niemann, Hasso B.↗

Intravenous Fluid Generation System

The ability to stabilize and treat patients on exploration missions will depend on access to needed consumables. Intravenous (IV) fluids have been identified as required consumables. A review of the Space Medicine Exploration Medical Condition List (SMEMCL) lists over 400 medical conditions that could present and require treatment during ISS missions. The Intravenous Fluid Generation System (IVGEN) technology provides the scalable capability to generate IV fluids from indigenous water supplies. It meets USP (U.S. Pharmacopeia) standards. This capability was performed using potable water from the ISS; water from more extreme environments would need preconditioning. The key advantage is the ability to filter mass and volume, providing the equivalent amount of IV fluid: this is critical for remote operations or resource- poor environments. The IVGEN technology purifies drinking water, mixes it with salt, and transfers it to a suitable bag to deliver a sterile normal saline solution. Operational constraints such as mass limitations and lack of refrigeration may limit the type and volume of such fluids that can be carried onboard the spacecraft. In addition, most medical fluids have a shelf life that is shorter than some mission durations. Consequently, the objective of the IVGEN experiment was to develop, design, and validate the necessary methodology to purify spacecraft potable water into a normal saline solution, thus reducing the amount of IV fluids that are included in the launch manifest. As currently conceived, an IVGEN system for a space exploration mission would consist of an accumulator, a purifier, a mixing assembly, a salt bag, and a sterile bag. The accumulator is used to transfer a measured amount of drinking water from the spacecraft to the purifier. The purifier uses filters to separate any air bubbles that may have gotten trapped during the drinking water transfer from flowing through a high-quality deionizing cartridge that removes the impurities in the water before entering the salt bag and mixing with the salt to create a normal saline solution.

McQuillen, John↗

Mass Spectrometer Observing Lunar Operations (MSoLo)

Introduction: In 2019, the National Aeronautics and Space Administration (NASA) announced that it would seek to have humans return to the moon by 2024 in the hopes of establishing a more sustainable lunar presence by 2028. This goal comes with many challenges, one of upmost importance will be to utilize resources that can be found on the moon. Water, which has been identified in the lunar Polar Regions, will be a key resource for in-situ resource utilization (ISRU), as it is capable of being processed for vehicular fuel, as well as life support systems materials such as oxygen. Upcoming Commercial Lunar Payload Services (CLPS) missions will be critical for these resource assessments. Methods: A modified commercial off-the-shelf (COTS) mass spectrometer developed at Kennedy Space Center known as MSolo, consisting of a quadrupole mass filter and space rated electronics undergoes testing and modifications in order to study operational parameters to unconventional approaches needed in flight situations. In general, MSolo operates in the 0-100 m/z range with the ability to detect with a faraday cup (FC) or an electron multiplier (EM) for enhanced detection. A crossbeam (XB) ionization source is used. Preliminary Data: Prior to construction, little information was available on how the MSolo system would perform at lunar like environments, factors such as temperatures (possible fluctuations from 70 to -45 °C), vibrations from launch and their side effects, the general ability to operate while the entire system (hardware and electronic components) were in a vacuum environment, were factors that while know to flight instruments, were something new to a modified COTS system. As components start to warm up, temperature becomes a key factor (ie. heat can no longer escape the electronics as no atmosphere is present), therefore it becomes crucial to find new ways to maintain stable signals and keep the instrument tuned. Calibration itself becomes an important parameter that needs to be performed while maintaining all flight like characteristics. Even the structure itself of MSolo’s sensor needed to be changed to survive the verification parameters needed to be approved for flight. Most important, all the modifications made to the COTS system have to keep the instrument working at the same specifications of the standard commercial systems. Novel Aspect: Results gathered provide key parameters that will assist to the unconventional mass spectrometry approaches of the upcoming CLPS missions to which MSolo has been selected to.

MSolo↗

Progress towards the FRIB-EDM 3 -Frontend: A tool to provide radioactive molecules from isotope harvesting for fundamental symmetry studies

The under-construction FRIB-EDM 3 -instrument was designed to study polar radioactive molecules (such as RaF) in transparent cryogenic solids by laser spectroscopy. The instrument is divided into a frontend- and a backend section. The frontend accepts an aqueous sample from isotope harvesting and provides a mass-separated molecular ion beam in an ultra-high vacuum environment. In the backend, the ions are guided into alkali-metal vapor and the resulting neutrals are co-deposited in a solid argon matrix to perform laser spectroscopy. Here, this work addresses the frontend of the instrument. The efficient ionization of harvested radioisotopes from aqueous samples is achieved with a spray-ionization method. Subsequently, the molecular ion beam is analyzed by mass-to-charge ratio by a quadrupole mass filter. To verify the feasibility of the approach, numerical simulations with the COMSOL and SIMION packages have been conducted. While the former was applied to study transport in ion funnels, the latter was used to investigate ion beam transmission through the lower pressure sections. Following promising simulation results, a first experimental setup is under construction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Curious cross-field transport effects in multi-ion, magnetized plasma

In contrast to single-ion plasma, multiple-ion-species plasma exhibits new, curious, and large transport effects. On short timescales, where ions exchange momentum, magnetized multi-ion plasma behaves as a most unusual substance, compressible across field lines in number density but incompressible in charge density. It takes 40 times longer for electrons to participate. In this ion–ion cross-field transport regime, we identified the charge-incompressibility heat pump effect, transferring heat both spatially and between species. Curiously, the direction of impurity transport strongly depends on plasma magnetization, characterized by the ratio of light ion gyrofrequency to the collision frequency between light and heavy ion species. The expulsion of heavy ion impurities from a hotspot occurs sufficiently quickly to be observable on MagLIF, so long as plasma becomes sufficiently collisionally magnetized under implosion. Even more curious, multi-ion transport changes its nature in partially ionized plasma, where ions occupy different charge states. In this regime, we identify a partial-ionization deconfinement effect. The combination of cross-field transport, ionization, and recombination leads to a net ion charge moving across magnetic field lines on the ion–ion transport timescale as opposed to the electron–ion transport timescale. Cross-field transport effects in multi-ion plasma are important in a number of applications, including nuclear fusion and plasma mass filters.

Mlodik, M. E. (ORCID:0000000343003941)↗