Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEA testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Durable Mn-Based PGM-Free Catalysts for Polymer Electrolyte Membrane Fuel Cells

This proposed project aims to develop and evaluate novel manganese based, nitrogen-derived, PGM-free electrocatalysts (denoted as Mn-N-C) to fully address the membrane electrolyte assemblies (MEA)’s ionomer degradation issue resulting from iron. Four thrusts will be pursed in this proposed project. First, advanced first-principles computation methods will be employed to accelerate the rational catalyst design and synthesis. Second, an effective hydro-gel method will be used to maximize atomic Mn active sites embedded in carbon matrix. Next, state-of-the art methods in fuel cell companies will be used to fabricate MEAs containing the Mn-N-C catalysts. Finally, industry standards will be rigorously followed to evaluate fuel cell performance and durability of the Mn-N-C catalysts. With successful completion of the project, it is expected that the following outcomes will be achieved. (1) A set of MEAs containing the Mn-N-C catalysts and with active area large than 50 cm 2 for independent testing, (2) testing results demonstrating that the MEAs of Mn-N-C catalysts have mass activity of 0.044 A/cm 2 at 0.9 VIR-free and H 2 /air performance of 0.50 V at 1.0 A/cm 2 ; (3) fundamental understanding of the composition-structure-property relation of the PGM-free Mn- N-C catalysts, and (4) computational data, measurement data, and publications deposited into the database of ElectroCat Consortium.

08 HYDROGEN↗

Ion-Pair Proton Exchange Membrane Fuel Cells for Heavy-duty Transportation

The purpose of this project is to build a fuel cell prototype that demonstrates high temperature proton exchange membrane fuel cell technology (HT PEMFC) commercial readiness. It advances from a technology baseline established in a prior CRADA in which these same Parties collaborated during the years 2020-2024. These efforts are aligned with the intentions of the DOE Hydrogen Fuel Cell Technology Office (HFTO) L’Innovator Pilot Program. Participant observes that its US-based competitive advantage may be improved by further optimizing Laboratory inventions. This CRADA is intended to further improve National Laboratory compositions and to develop commercial HT PEMFC membrane electrode assemblies (MEAs) that perform over a range of operating temperatures and relative humidity, that generate power from both low grade and pure hydrogen, and that are resistant to air impurities. Participant’s goal is to advance the commercial competitiveness of National Laboratory technologies in fuel cell products for heavy-duty truck integrators, for stationary power generation, marine applications, and for emerging interest from commercial aviation. The Parties will collaborate on producing a HT PEMFC MEA that integrates LANL ion pair technology and Brookhaven catalyst technology. The Laboratories plan to research and develop compositions for testing and evaluation. The participant will manufacture multiple MEAs based on the Laboratory compositions and will enable selected customers to validate performance characteristics. The Laboratories will convey to Participant the methods of making the National Laboratory compositions such that Participant may reproduce and then scale Laboratory methods into commercial production. Throughout the project, the Laboratories and Participant will iteratively test and optimize the compositions of materials of the MEAs, intending to optimize characteristics such as power density and lifecycle durability. Participant’s intended customers include fuel cells for large trucks, aviation, power back up, marine, and portable power.

99 GENERAL AND MISCELLANEOUS↗

Innovative duo-recombination layer design for effective hydrogen crossover mitigation in advanced MEAs for PEM water electrolyzers

Hydrogen crossover in proton exchange membrane water electrolyzers (PEMWEs) poses a safety hazard, reduces the overall efficiency, and limits the operational differential pressure range. Here, in this study, a membrane electrode assembly (MEA) with innovative Pt duo-recombination layer (DRL) design is developed by the unique reactive spray deposition technology (RSDT). The novel design comprises two thin RLs integrated within the volume of the membrane and has a total Pt loading of only 0.04 mg Pt cm −2 . Long-term durability test for over 3000 h is performed with as-fabricated MEA at steady-state conditions typical for an industrial hydrogen production system. The results from the durability test show that the newly developed DRL design effectively suppresses the H2 crossover to below 0.5 vol%. Furthermore, comprehensive post-test characterization of the MEA is performed and potential failure mechanisms in the Pt RLs observed during the durability test are identified and discussed in detail for the first time.

08 HYDROGEN↗

Novel platinum group metal-free catalyst ink deposition system for combinatorial polymer electrolyte fuel cell performance evaluation

Here, a new system for rapid and precise fabrication of polymer electrolyte fuel cell (PEFC) membrane-electrode assemblies (MEAs) is introduced to facilitate rapid testing and characterization of platinum group metal-free (PGM-free) catalysts, with minimal waste of materials, using commercial combinatorial hardware and multi-channel potentiostat. The commercial combinatorial system, designed for high-throughput catalyst activity evaluation (i.e., low overpotential and current densities) using gas-diffusion electrodes (GDEs), has been further developed to enable simultaneous evaluation of the high current density performance on air of twenty-five cathodes prepared by coating catalyst-ionomer inks directly onto the membrane using a newly-developed deposition system. A nanopipette or micropipette coupled to a precise peristaltic pump is being used for precise and even catalyst ink deposition onto the membrane in each of twenty-five circular electrodes with areas of <1 cm 2 and in the precise locations required by the commercial combinatorial MEA hardware. The automated ink deposition system is coupled with a custom-designed heated vacuum table mounted on a computer-controlled XY stage to prevent deformation of the membrane and electrode layers during ink deposition onto the membrane. This system was utilized to evaluate the impact of ionomer to catalyst ratio on the hydrogen-air fuel cell performance of the PGM-free catalyst.

25 ENERGY STORAGE↗

Effect of Commercial Gas Diffusion Layers on Catalyst Durability of Polymer Electrolyte Fuel Cells in Varied Cathode Gas Environment

Gas diffusion layers (GDLs) play a crucial role in heat transfer and water management of cathode catalyst layers in polymer electrolyte fuel cells (PEFCs). Thermal and water gradients can accelerate electrocatalyst degradation and therefore the selection of GDLs can have a major influence on PEFC durability. Currently, the role of GDLs in electrocatalyst degradation is poorly studied. Here, we perform electrocatalyst accelerated stress test studies on membrane electrode assemblies (MEAs) prepared using three most commonly used GDLs. The effect of GDLs on electrocatalyst degradation is evaluated in both nitrogen (non-reactive) and air (reactive) gas environments at 100% relative humidity. In situ electrochemical characterization and extensive physical characterization is performed to understand the subtle differences in electrocatalyst degradation and correlated to the use of different GDLs. Overall, no difference is observed in the electrocatalyst degradation due to GDLs based on polarization curves at the end of life. But interestingly, MEA with a cracked microporous layer (MPL) in the GDL exhibited a higher electrocatalyst loading loss, which resulted in a lower and more heterogeneous increase in the average electrocatalyst nanoparticle size.

25 ENERGY STORAGE↗

An atomistic study connecting underlying dislocation behavior with superior mechanical properties of NiCoCr medium entropy alloy

NiCoCr-based medium-entropy alloy (MEA) with a simple face-centered cubic crystal phase exhibits excellent mechanical properties, often attributed to the synergy of multiple deformation mechanisms. However, the atomistic origin of their outstanding mechanical response, including microstructural evolution and dislocation behavior under varying strain-rates and orientation, remains unclear. In this work, we employ large-scale molecular dynamics (MD) simulations to investigate the changes in deformation mechanisms along three distinct orientations ([110], [111], [100]) under varying strain rates (1 ×10 8 /sec, 1 ×10 10 /sec, 1 ×10 12 /sec) in the NiCoCr MEA. The presence of the stair-rod and the Shockley partial dislocations under uniaxial tensile strain are found to play a key role in the formation of deformation twinning and ε-martensite, which positively correlates with strain-rate dependent dislocation analysis. These findings further establish the role of the dislocations in controlling the superior mechanical response and excellent fracture toughness of the NiCoCr MEA. Systematic transmission-electron microscopy tests performed on the [111]-oriented crystals, deformed at different strain levels, at room temperature provide clear evidence of both the extended stacking-fault and the stair rods, confirming the predicted microstructural features. Finally, this study offers key insights into the complex nucleation mechanisms of deformation twinning and ε-martensite, such as twinning – and transformation–induced plasticity (TWIP-TRIP), providing valuable guidelines for studying similar material classes.

36 MATERIALS SCIENCE↗

A Relief Zone Architecture for Enhanced Durability of Ultrathin Membranes in Electrochemical Conversion Devices

Premature cell failures in electrochemical conversion systems often result when membrane electrode assemblies (MEAs) are prepared with ultra-thin (= 15 micrometer-thick) polymer electrolyte membranes (PEMs). These high-performance PEMs are susceptible to mechanical degradation from stress concentrations arising from component and device-level integration. Herein, a relief zone was developed to mitigate mechanical degradation by alleviating excess and non-uniform compression across the active area. Relief zones, created through the ablation of carbonaceous diffusion material achieves a seamless adaptation across a range of MEA dimensions and electrochemical applications without need for costly hardware modifications. This concept was demonstrated using fuel cells as a case study. Accelerated stress test (AST) validations yielded a 6-fold improvement for MEAs prepared with relief zones (i.e., lifetime approximately 1500 h) compared to those fabricated using conventional edge-protection techniques, showcasing the utility of this technique in decoupling integration and device-level engineering effects from intrinsic material limitations for durable electrochemical devices.

14 SOLAR ENERGY↗

Impact of Carbon Support Structure on the Durability of PtCo Electrocatalysts

High performing, low-Pt content fuel cell membrane electrode assemblies (MEAs) are critical to the economic viability of proton exchange membrane fuel cells (PEMFCs) for the transportation industry. Considerable research has been conducted to reduce the Pt content in fuel cells, leading to the development of transition metal alloys, such as Platinum-Cobalt (PtCo). The degree of degradation of PtCo catalysts can be impacted by the catalyst metal itself and its interactions with the carbon support. Several low-loaded PtCo MEAs were fabricated, with various combinations of porous and solid carbon cathode catalyst supports. The MEAs were subjected to an accelerated stress test (AST), and the catalyst degradation characterized using electrochemical, X-ray scattering, and electron microscopy techniques. Porous supports retain more of their electrochemically-active surface area (ECSA) and demonstrate higher performance after the AST. Overall, this is believed to be due to the ability of the porous supports to trap the metal particles within the pores, slowing their dissolution/precipitation, and agglomeration.

25 ENERGY STORAGE↗

Impact of Carbon Support Structure on the Durability of PtCo Electrocatalysts

High performing, low-Pt content fuel cell membrane electrode assemblies (MEAs) are critical to the economic viability of proton exchange membrane fuel cells (PEMFCs) for the transportation industry. Considerable research has been conducted to reduce the Pt content in fuel cells, leading to the development of transition metal alloys, such as Platinum-Cobalt (PtCo). The degree of degradation of PtCo catalysts can be impacted by not only the composition and morphology of the catalyst particle itself, but also its interactions with the carbon support. In this study several low-PtCo MEAs were fabricated, with various combinations of porous and solid carbon cathode catalyst supports. The MEAs were subjected to an accelerated stress test (AST), and the catalyst degradation characterized using electrochemical, X-ray scattering, and electron microscopy techniques. Porous supports retain more of their electrochemically-active surface area (ECSA) and demonstrate higher performance after the AST. This is believed to be due to the ability of the porous supports to trap the metal particles within the pores, slowing their dissolution/precipitation, and agglomeration. However porous supports also exhibit greater increases in transport resistance probably associated with enhanced Co leaching under the AST conditions.

25 ENERGY STORAGE↗

Pt–Co truncated octahedral nanocrystals: a class of highly active and durable catalysts toward oxygen reduction

We report a facile and scalable synthesis of Pt–Co truncated octahedral nanocrystals (TONs) by employing Pt(acac) 2 and Co(acac) 2 as precursors, together with CO molecules and Mn atoms derived from the decomposition of Mn 2 (CO) 10 as a reductant and a {111} facet-directing agent, respectively. Both the composition and yield of the Pt–Co TONs could be varied through the introduction of CHCl 3 . When tested at 80 °C using membrane electrode assembly (MEA), the 4 nm Pt 2.6 Co TONs gave a mass activity of 294 A g Pt –1 at beginning-of-life (BOL) and it increased to 384 A g Pt –1 during recovery cycles. The mass activity at BOL only dropped by 24% after 30 000 voltage cycles at end-of-life (EOL) in a metal dissolution accelerated stress test. The Pt 2.6 Co/C catalyst outperformed the commercial TKK Pt 3 Co/C (230 A g Pt –1 at BOL and 40% loss after 30 000 cycles at EOL) in terms of both activity and durability. Our systematic analysis suggested that the enhancement in activity can be attributed to the combination of small, uniform size and well-defined {111} facets. This new class of catalysts holds promise for applications in proton-exchange membrane fuel cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Constructing Highly Porous Low Iridium Anode Catalysts Via Dealloying for Proton Exchange Membrane Water Electrolyzers

Iridium (Ir) is the most active and durable anode catalyst for the oxygen evolution reaction (OER) for proton exchange membrane water electrolyzers (PEMWEs). However, their large-scale applications are hindered by high costs and scarcity of Ir. Lowering Ir loadings below 1.0 mgcm -2 causes significantly reduced PEMWE performance and durability. Therefore, developing efficient low Ir-based catalysts is critical to widely commercializing PEMWEs. Herein, an approach is presented for designing porous Ir metal aerogel (MA) catalysts via chemically dealloying IrCu alloys. In this study, the unique hierarchical pore structures and multiple channels of the Ir MA catalyst significantly increase electrochemical surface area (ECSA) and enhance OER activity compared to conventional Ir black catalysts, providing an effective solution to design low-Ir catalysts with improved Ir utilization and enhanced stability. An optimized membrane electrode assembly (MEA) with an Ir loading of 0.5 mg Ir cm -2 generated 2.0 A cm -2 at 1.79 V, higher than the Ir black at a loading of 2.0 mg Ir cm -2 (1.63 A cm -2 ). The low-Ir MEA demonstrated an acceptable decay rate of ≈40 µV h -1 during durability tests at 0.5 (>1200 h) and 2.0 A cm -2 (400 h), outperforming the commercial Ir-based MEA (175 µV h -1 at 2.0 mg Ir cm -2 ).

36 MATERIALS SCIENCE↗

The influence of electrode crack dimensions on the durability of polymer electrolyte membrane fuel cells

Electrode cracks in polymer electrolyte membrane fuel cells (PEMFCs) are correlated with early onset failures. Here, in this work we investigate the influence of cracked gas diffusion electrodes (GDEs) on the durability of the membrane electrode assembly (MEA) using a combined chemical-mechanical accelerated stress test (AST). Electrode crack dimensions were systematically tuned using ink formulations and material selection strategies. A parameter to describe the crack width areal density (Φ CW ) was used to quantify the degree of discontinuity in the electrode surfaces. Open circuit voltage (OCV) transient analyses were used to benchmark and characterize the failure mechanisms in the MEAs as a function of the Φ CW . While smaller electrode-level cracks, on the order of microns, yielded a 28 % decrease in operating lifetime, larger cracks that propagated from a discontinuous, microporous layer (MPL) coating, decreased the operating lifetime by 56 %. This work emphasizes the need for material processing strategies that consider defect tolerances to limit membrane failures in PEMFCs.

08 HYDROGEN↗

Relief Zones Enhance the Durability of Ultrathin Membranes in Electrochemical Conversion Devices

Premature failures in electrochemical conversion systems often result when membrane electrode assemblies (MEAs) use ultrathin (≤15 μm-thick) polymer electrolyte membranes, susceptible to mechanical degradation from stress concentrations arising from device-level integration. Herein, relief zones were developed to mitigate mechanical degradation by alleviating excess and nonuniform compression across active areas. Relief zones, created through ablation of carbonaceous diffusion media, enable seamless adaptation across MEA dimensions without need for hardware modifications. Demonstrated using fuel cells as a case study, accelerated stress tests revealed a 6-fold lifetime improvement (∼1500 h) compared to conventional edge-protected MEAs, decoupling device-level engineering effects from material limitations.

accelerated stress test↗

Multi-modal characterization of nitrate reduction nano-catalysts with periodic strain distribution

Strain engineering serves as a pivotal strategy to optimize catalytic activity in electrocatalysis. However, the catalyst sizes under industrial conditions are usually large and even beyond nanometer regime. The critical methodological limitations on strain imaging of such catalysts with both large field of view and high spatial resolution obscure the mechanistic understanding of strain-performance correlations. Here, we present an optimized four-dimensional scanning transmission electron microscopy (4D-STEM) method to acquire strain mapping of both bulk and surface across particles up to 500 nm with 0.6 nm spatial resolution and 0.55% precision. We observe the ripple-like periodic strain coupled with elemental fluctuations inside a perovskite-type hydroxide CuCoSn(OH) 6 and find it correlated to electrocatalytic nitrate reduction (NO 3 – RR) absorption energy to achieve the 92.6% Faradaic efficiency and long-term test over 1000 h at membrane electrode assembly (MEA) for ammonia electrosynthesis. This universal framework design offers a practical method that not only develops an advanced measurement combining multi-modal characterization techniques but also reveals the intrinsic structure-property constitutive law of industry-level catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Durability of PGM catalyst MEAs of polymer electrolyte membrane fuel cells for heavy-duty vehicles

Polymer electrolyte membrane fuel cells (PEMFCs) are promising power sources for heavy-duty vehicles (HDVs) owing to cleanliness and efficiency. However, the degradation of membrane electrode assemblies (MEAs) under HDV conditions remains a huge challenge. Here, this work investigated MEA durability under HDV conditions using a US Department of Energy standard accelerated stress test for 180,000 cycles (equivalent to 1 million miles of HDV operation). Effects of catalyst Pt content on MEA durability were examined using homemade 30% Pt/C (H-Pt/C) and commercial 46% Pt/C (C-Pt/C) catalysts. Both MEAs experienced H 2 /air and H 2 /O 2 performance loss over cycles. Analysis with scanning transmission electron microscopy, X-ray diffraction, inductively coupled plasma mass spectrometry, and mercury intrusion porosimetry revealed severe degradation of Pt nanoparticles (NPs), support structures, and the catalyst layer. Two degradation stages for NPs were proposed: Ostwald ripening dominated the initial 60,000 cycles, followed by combined Ostwald ripening and particle migration. Measurements with ion chromatography, high-frequency resistance, and oxygen-diffusion resistance revealed degradation of membrane and ionomer, respectively.

25 ENERGY STORAGE↗

High-performance SO 2 -depolarized electrolysis cell using advanced polymer electrolyte membranes

Three different proton conducting polymeric membrane materials (Nafion® 115, Nafion® 212, and sulfonated Diels-Alder polyphenylene [SDAPP]) were evaluated for use in SO 2 -depolarized electrolyzers for the production of hydrogen via the hybrid sulfur cycle. Their performance was measured using different water feed strategies to minimize overpotential losses while maintaining high product acid concentration. Both thin membranes (Nafion® 212 and SDAPP) showed performance superior to that of the thicker Nafion® 115. Here, the SDAPP membrane electrode assembly (MEA) performed well at higher acid concentrations, maintaining low ohmic and kinetic overpotentials. Finally, short-term (100-h) stability tests under constant current conditions showed minimal degradation for the SDAPP and Nafion® 212 MEAs. SDAPP MEA performance approached the targets needed to make the hybrid sulfur cycle a competitive process for hydrogen production (product acid concentration ≥65 wt% H 2 SO 4 at ≤ 0.6-V cell potential and ≥0.5 A-cm –2 current density).

08 HYDROGEN↗

Excellent high cyclic fatigue properties of a novel ultrafine-grained medium entropy alloy

Fatigue is a major cause of failure and requires dedicated investigation to validate the integrity of potential structural materials. As high and medium entropy alloys (HEAs and MEAs) are garnering significant attention from scientific communities, it is important to test the structural integrity of these novel alloys in cyclic loading environment. This study analyzed both monotonic and cyclic loading properties of a novel medium entropy alloy (MEA) CoCr 1.3 Ni in the ultrafine-grained (UFG) and fine grain (FG) conditions. The UFG MEA performs better than the FG MEA during cyclic loading. Microstructural evolution after cyclic loading via electron back-scattered diffraction shows microstructural stability of both FG and UFG microstructures. Transmission electron microscopy suggests formation of stacking faults and fine-scale HCP transformation during cyclic loading.

36 MATERIALS SCIENCE↗

Application of a Heat Integrated Post-combustion CO 2 Capture System with Hitachi Advanced Solvent into Existing Coal-Fired Power Plant (Final Technical Report)

The goal of this final project report is to comprehensively summarize the work conducted on project DE-FE0007395. In accordance with the Project Management Plan (PMP), Revision F dated 5/10/2019, and Statement of Project Objectives (SOPO) within, the University of Kentucky (UK) Center for Applied Energy Research (CAER) (Recipient) has successfully demonstrated a unique, versatile CO 2 capture system (CCS) using a heat integrated process combined with two-stage stripping for process intensification, heat recovery and demineralized (DM) water generation. This project involved the design, fabrication, installation, testing of and data analysis from the UK CAER 0.7 MWe small pilot scale CO2 capture process installed at Kentucky Utilities (KU) E.W. Brown Generating Station in Harrodsburg, KY. During each of the four project Budget Periods (BPs), UK CAER met all project deliverables, all project milestones, with National Energy Technology Laboratory (NETL) approved adjustments made to the campaign long-term hours during BP4. The CCS was constructed in modular skids. Two solvent campaigns were initially conducted; the first with a 30 wt% monoethanolamine (MEA) as a baseline, and the second with the Hitachi H3-1 advanced solvent. Additional tests were performed with two advanced solvents including CAER and Proprietary Solvent C. Short-period testing with a higher concentration of 40 wt% MEA was conducted to evaluate the potential saving with high alkalinity. From the various solvent campaigns, unique aspects of the UK CAER CCS technology, as well as its flexibility and versatility were experimentally validated and demonstrated. With respect to solvent evaluation efforts in identifying candidates with significant operational and capital cost savings potential, performance of solvents were evaluated to determine the energy requirements for regeneration; environmental impacts from secondary emissions and degradation products; degradation rates, solvent make-up rates and stability. The assessments were done from parametric tests that determined optimum operating conditions for the individual solvents to maximize process efficiency and minimize the parasitic load of the power plant, and from long term campaigns (1000 hours for 30 wt% MEA and 1000 hours for H3-1) which collectively informed the techno-economic analyses (TEA) of the process. The long term campaigns included corrosion studies which used three types of metal coupons in different sections of the process: (absorber, primary stripper, lean carbon-loaded and rich carbon loaded flow streams in process) to mimic heat and flow dynamics process equipment were exposed to. The estimated corrosion rates were used to elucidate corrosion mechanisms and to further guide process material selection for potential capital cost savings.

gas separation↗