Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEASURING METHODS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Testing and Validation of the Dynamic Interia Measurement Method

This presentation describes the DIM method and how it measures the inertia properties of an object by analyzing the frequency response functions measured during a ground vibration test (GVT). The DIM method has been in development at the University of Cincinnati and has shown success on a variety of small scale test articles. The NASA AFRC version was modified for larger applications.

vibration tests↗

Oscillator strengths of neutral titanium from hook method measurements in a furnace. I - Lines from the a 3F2, 3 and 4 levels at 0, 0.021, and 0.048 eV

Oscillator strengths for 134 lines from the ground term of neutral titanium have been measured by the hook method. The data, which are normalized to those of Bell, Kalman and Tubbs, agree well with most previously measured data but indicate that there is a line strength dependent error in the National Bureau of Standards compilation of TiIf-values by Wiese and Fuhr.

Smith, P. L.↗

Oscillator strengths of ultraviolet Fe I lines from hook-method measurements on a furnace

The hook method, which makes use of anomalous dispersion, was employed to measure 107 absolute oscillator strengths of Fe I on a high-temperature furnace. The absolute scale was established before and after each run by recording the anomalous dispersion near a strong resonance line with accurately known f-value. The results cover three lines with wavelengths from 1934 to 1941 A, and 104 lines lying between 2084 and 3194 A - mostly transitions originating from the a 5 D ground state. The average error of the f-values is plus or minus 20%, and the largest and smallest errors given are plus or minus 10 and plus or minus 60%. Disagreements exceeding an order of magnitude are found with previous values in the literature.

Banfield, F. P.↗

Global Precipitation Measurement: Methods, Datasets and Applications

This paper reviews the many aspects of precipitation measurement that are relevant to providing an accurate global assessment of this important environmental parameter. Methods discussed include ground data, satellite estimates and numerical models. First, the methods for measuring, estimating, and modeling precipitation are discussed. Then, the most relevant datasets gathering precipitation information from those three sources are presented. The third part of the paper illustrates a number of the many applications of those measurements and databases. The aim of the paper is to organize the many links and feedbacks between precipitation measurement, estimation and modeling, indicating the uncertainties and limitations of each technique in order to identify areas requiring further attention, and to show the limits within which datasets can be used.

Global Climate Models (GCM)↗

An Evaluation of the Plasticity-Induced Crack-Closure Concept and Measurement Methods

An assessment of the plasticity-induced crack-closure concept is made, in light of some of the questions that have been raised on the validity of the concept, and the assumptions that have been made concerning crack-dp damage below the crack-opening stress. The impact of using other crack-tip parameters, such as the cyclic crack-tip displacement, to model crack-growth rate behavior was studied. Crack-growth simulations, using a crack-closure model, showed a close relation between traditional Delta K eff, and the cyclic crack-tip displacement (Delta eff) for an aluminum alloy and a steel. Evaluations of the cyclic hysteresis energy demonstrated that the cyclic plastic damage below the crack-opening stress was negligible in the Paris crack-growth regime. Some of the standard and newly proposed remote measurement methods to determine the 'effective' crack-tip driving parameter were evaluated on middle-crack tension specimens. A potential source of the Kmax effect on crack-growth rates was studied on an aluminum alloy. Results showed that the ratio of Kmax to Kc had a strong effect on crack-growth rates at high stress ratios and at low stress ratios for very high stress levels. The crack-closure concept and the traditional crack-growth rate equations were able to correlate and predict crack-growth rates under these extreme conditions.

Newman, James C., Jr.↗

Detector absorptivity measuring method and apparatus

A method and apparatus for measuring the absorptivity of a radiation detector by making the detector an integral part of a cavity radiometer are described. By substituting the detector for the surface of the cavity upon which the radiation first impinges a comparison is made between the quantity of radiation incident upon the detector and the quantity reflected from the detector. The difference between the two is a measurement of the amount of radiation absorbed by the detector.

Sheets, R. E.↗

Faraday rotation measurement method and apparatus

A method and device for measuring Faraday rotation of a received RF signal is described. A simultaneous orthogonal polarization receiver compensates for a 3 db loss due to splitting of a received signal into left circular and right circular polarization channels. The compensation is achieved by RF and modulation arraying utilizing a specific receiver array which also detects and measures Faraday rotation in the presence or absence of spin stabilization effects on a linear polarization vector. Either up-link or down-link measurement of Faraday rotation is possible. Specifically, the Faraday measurement apparatus utilized in conjunction with the specific receiver array provides a means for comparing the phase of a reference signal in the receiver array to the phase of a tracking loop signal related to the incoming signal, and comparing the phase of the reference signal to the phase of the tracking signal shifted in phase by 90 degrees. The averaged and unaveraged signals, are compared, the phase changes between the two signals being related to Faraday rotation.

Brockman, M. H.↗

A software‐defined networks ‐based measurement method of network traffic for 6G technologies

Abstract In software‐defined networks (SDN) for 6G technologies, the controller should accurately and efficiently measure the flow traffic in switches for traffic engineering. Fine‐grained flow measurement can more accurately describe the traffic in the network, but it also consumes much more resources. To reduce the overhead incurred in the measurement process and obtain the approximate fine‐grained measurements, we propose a novel lightweight measurement scheme that runs in the controller. The novel lightweight measurement architecture consists of two parts: coarse‐grained measurement and interpolation‐optimization. In the first part, based on the SDN architecture, we use the pull‐based random sampling method to quickly obtain the coarse‐grained measurement of flow traffic through OpenFlow protocol. In the second part, we insert some discrete values into the coarse‐grained measurement with the interpolation theory, then we optimize interpolation results until finding the optimal fine‐grained flow traffic measurement by utilizing the multiconstraint method. We verified the feasibility of the proposed measurement method, and simulation results show that the measurement error of the proposed method is under 25%, but the flow measurement overhead of this method occupies only 3.3% compared with that of the fine‐grained method.

Huo, Liuwei↗

New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

Evaluation Studies↗

Small bore magnetic measurement system, method for measuring small bore magnets

The invention provides a system for measuring magnets, the system comprising a guide tube removably received by a beam chamber tunnel, wherein said guide tube has a first end terminating at a first end of the tunnel and a second end terminating at a second end of the tunnel; a flexible substrate removably and slidably received by the tube, wherein the flexible substrate has a first end and a second end; a first rotary stage removably attached to the first end of said flexible substrate and a second rotary stage removably attached to the second end of said flexible substrate wherein the first rotary stage and the second rotary stage effects movement of the substrate through the tube; and a Hall probe supported by the flexible substrate. Also provided is a method for measuring magnetic fields, the method comprising extending a measuring probe into a magnetic core while maintaining the probe at ambient temperature and pressure.

Kasa, Matthew T.↗

Background measurement methods for opacity experiments conducted at the Z facility

Laboratory experiments typically test opacity models by measuring spectrally resolved transmission of a sample using bright backlight radiation. A potential problem is that any unaccounted background signal contaminating the spectrum will artificially reduce the inferred opacity. Methods developed to measure background signals in opacity experiments at the Sandia Z facility are discussed. Preliminary measurements indicate that backgrounds are 9%–11% of the backlight signal at wavelengths less than 10 Å. Background is thus a relatively modest correction for all Z opacity data published to date. Future work will determine how important background is at longer wavelengths.

47 OTHER INSTRUMENTATION↗

Photographic method measures particle size and velocity in fluid stream

Method employing a nonframing motion picture camera, a continuous front light source, and a strobe light determines the size and velocity of small particles in nonturbulent fluid streams. This method is used in the study of the motion of solid and liquid particles in research and industrial fluid flow systems.

Dickerson, R. A.↗

Experimental Validation of the Dynamic Inertia Measurement Method to Find the Mass Properties of an Iron Bird Test Article

The mass properties of an aerospace vehicle are required by multiple disciplines in the analysis and prediction of flight behavior. Pendulum oscillation methods have been developed and employed for almost a century as a means to measure mass properties. However, these oscillation methods are costly, time consuming, and risky. The NASA Armstrong Flight Research Center has been investigating the Dynamic Inertia Measurement, or DIM method as a possible alternative to oscillation methods. The DIM method uses ground test techniques that are already applied to aerospace vehicles when conducting modal surveys. Ground vibration tests would require minimal additional instrumentation and time to apply the DIM method. The DIM method has been validated on smaller test articles, but has not yet been fully proven on large aerospace vehicles.

moments of inertia↗

Investigations of Advanced Measurement Methods for High-Temperature Heat-Pipe Experiments

Various types of microreactor designs are under consideration, and among those, the heat-pipe cooled reactor designs are currently being actively investigated at Idaho National Laboratory (INL). In order to support non-nuclear testing and demonstration of technology under the Department of Energy (DOE) Microreactor Program (MRP), Single Primary Heat Extraction and Removal Emulator (SPHERE) was designed and constructed to perform high-temperature heat pipe (HP) experiments at INL. Based on the SPHERE experimental setup, this summary paper conducts the preliminary investigations among the available literature and summarizes some potential advanced measurement techniques for operando high-temperature heat pipe which can be implemented to support MRP. The primary objective for the extensive literature research is to investigate the possibilities and feasibilities for designing and construct an advanced experimental test facility with the aim of producing high-fidelity high-resolution heat pipe data during its operations.

42 ENGINEERING↗

Comparisons of Force Measurement Methods for DBD Plasma Actuators in Quiescent Air

We have performed measurements of the force induced by both single (one electrode insulated) and double (both electrodes insulated) dielectric barrier discharge plasma actuators in quiescent air. We have shown that, for single barrier actuators with cylindrical exposed electrodes, as the electrode diameter decrease the force efficiencies increase much faster than a previously reported linear trend. This behavior has been experimentally verified using two different measurement techniques: stagnation probe measurements of the induced flow velocity and direct measurement of the force using an electronic balance. Actuators with rectangular cross-section exposed electrodes do not show the same rapid increase at small thicknesses. We have also shown that the induced force is independent of the material used for the exposed electrode. The same techniques have shown that the induced force of a double barrier actuator increases with decreasing narrow electrode diameter.

Hoskinson, Alan R.↗

Theory and Simulation of A Novel Viscosity Measurement Method for High Temperature Semiconductor

The properties of molten semiconductors are good indicators for material structure transformation and hysteresis under temperature variations. Viscosity, as one of the most important properties, is difficult to measure because of high temperature, high pressure, and vapor toxicity of melts. Recently, a novel method was developed by applying a rotating magnetic field to the melt sealed in a suspended quartz ampoule, and measuring the transient torque exerted by rotating melt flow on the ampoule wall. The method was designed to measure viscosity in short time period, which is essential for evaluating temperature hysteresis. This paper compares the theoretical prediction of melt flow and ampoule oscillation with the experimental data. A theoretical model was established and the coupled fluid flow and ampoule torsional vibration equations were solved numerically. The simulation results showed a good agreement with experimental data. The results also showed that both electrical conductivity and viscosity could be calculated by fitting the theoretical results to the experimental data. The transient velocity of the melt caused by the rotating magnetic field was found reach equilibrium in about half a minute, and the viscosity of melt could be calculated from the altitude of oscillation. This would allow the measurement of viscosity in a minute or so, in contrast to the existing oscillation cup method, which requires about an hour for one measurement.

Lin, Bochuan↗

A comparison of turbulence measurement methods

An experiment is described in which temperature (density) and velocity are measured separately but simultaneously as functions of time so that it is possible to determine the relationships among velocity, density, and the product of density and velocity. Temperatures were measured with a dual-wire thermocouple probe. Velocity data were supplied by a fringe laser-Doppler anemometer. Signals from thermocouples and the laser were recorded on FM magnetic tape for later processing.

Fralick, Gustave C.↗