Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Digital twin framework for PIP-II linac: AI-driven multi-scale modeling from ion source to 800 MeV

The PIP-II superconducting linac at Fermilab is designed to deliver multi-megawatt proton beams for neutrino physics and other high-intensity applications. To expedite commissioning and enhance operational reliability, we have developed an EPICS-based data flow framework that seamlessly integrates digital twins (DT) with physical twins (PT). These digital twins comprise high-fidelity beam dynamics models or data-driven surrogate models connected to their physical counterparts through real-time diagnostics and advanced machine-learning algorithms.Central to this framework is Linac_Gen, an accelerated simulation tool that incorporates convolutional neural networks, random forests, and genetic algorithms to provide up to a tenfold speedup in optimizing the accelerator geometry model. An EPICS translator layer ensures interoperability by efficiently mapping lattice parameters across diverse simulation platforms.Our EPICS-based framework supports multiple operational modes—monitoring, passive learning, closed-loop control, and online learning—covering the entire machine lifecycle. By leveraging HPC resources and multi-objective optimization techniques, the digital twin enables adaptive trajectory correction, real-time fault detection, and predictive modeling of beam stability. This comprehensive approach paves the way for robust, high-intensity operation and data-driven accelerator R&D at Fermilab.

Pathak, Abhishek [Fermilab]↗

12 C(p,p') 12 C Reaction ( E p =19.5–30 MeV) for Active Interrogation of Special Nuclear Material

Passive detection of special nuclear material (SNM) is challenging due to its inherently low rate of spontaneous emission of penetrating radiation, the relative ease of shielding, and the fluctuating and frequently overwhelming background. Active interrogation, the use of external radiation to increase the emission rate of characteristic radiation from SNM, has long been considered to be a promising method to overcome those challenges. Current active-interrogation systems that incorporate radiography tend to use bremsstrahlung beams, which can deliver high radiation doses. Low-energy ion-driven nuclear reactions that produce multiple monoenergetic photons may be used as an alternative. The 12 C ( p , p ' ) 12 C reaction is one such reaction that could produce large yields of highly penetrating 4.4- and 15.1-MeV gamma rays. This reaction does not directly produce neutrons below the approximately 19.7 MeV threshold, and the 15.1-MeV gamma-ray line is well matched to the photofission cross section of 235 U and 238 U . In this article, we report the measurements of thick-target gamma-ray yields at 4.4 and 15.1 MeV from the 12 C ( p , p ' ) 12 C reaction at proton energies of 19.5, 25, and 30 MeV. Measurements are made with two 3 -in. EJ-309 cylindrical liquid scintillation detectors and thermoluminescent dosimeters placed at 0 ° and 90 ° , with an additional 1.5 -in. Na I ( Tl ) cylindrical scintillation detector at 0 ° . We estimate the highest yields of the 4.4- and 15.1-MeV gamma rays of 1.65 × 10 10 and 4.47 × 10 8 sr - 1 μ C - 1 at a proton energy of 30 MeV, respectively. The yields in all experimental configurations are greater than in a comparable deuteron-driven reaction that produces the same gamma-ray energies— 11 B ( d , n γ ) 12 C . However, a significant increase of the neutron radiation dose accompanies the proton energy increase from 19.5 to 30 MeV.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Cosmic Supernova Neutrino and Gamma-Ray Backgrounds in the MeV Regime

Cosmic multimessenger backgrounds include relic diffuse components created in the early universe and contributions from individual sources. Here, we study both type Ia supernovae (SNe Ia) and core-collapse supernovae (CCSNe) contributions to the diffuse neutrino and gamma-ray backgrounds in the MeV regime referred to as DSNB and DSGB respectively. We show that the diffuse SN Ia background is 10 6 times lower (for $\overline{v}_e$) than the CCSN background making it negligible. Our predicted DSNB $\overline{v}_e$ flux at earth in the 19.3–32 MeV regime is 0.36 ν cm -2 s -1 . We also find that the DSNB flux in the energy range from 11.3 to 32 MeV varies by +29% with a change in the SFRD model from Madau & Fragos which yielded a minimum predicted flux, to the extragalactic background light reconstruction model (maximum predicted flux). The diffuse SN Ia gamma-ray background and its dependence on the progenitor supernova delay time distribution are also evaluated. Furthermore, we address the origin of the CGB (Cosmic Gamma-ray Background) in the 0.1–7 MeV regime by adding contributions from sources such as SNe Ia, CCSNe, radio-quiet Active Galactic Nuclei, Flat spectrum radio quasars (FSRQs) and Neutron star—neutron star mergers. We find that our modeled background (including uncertainties) matches the observed CGB above 1.0 MeV, but is a factor ≈2 lower than the observed flux in the 0.1–1.0 MeV range, highlighting the need for future MeV missions to establish the CGB spectrum more reliably, and to possibly identify additional sources or even source classes in the underexplored MeV band.

79 ASTRONOMY AND ASTROPHYSICS↗

High-luminosity meV-resolution single-shot hard X-ray spectrograph for cavity-based X-ray free-electron lasers

Cavity-based X-ray free-electron lasers (CBXFELs) represent a possible realization of fully coherent hard X-ray sources having high spectral brilliance along with a narrow spectral bandwidth of ∼1–50 meV, a high repetition pulse rate of ∼1 MHz, and good stability. A diagnostic tool is required to measure CBXFEL spectra with meV resolution and high luminosity on a shot-to-shot basis. We have designed a high-luminosity single-shot hard X-ray spectrograph that images 9.831 keV X-rays in a ∼200 meV spectral window with a spectral resolution of a few meV. The spectrograph is designed around angular dispersion of X-rays in Bragg diffraction from crystals. It operates close to design specifications, exhibiting a linear dispersion rate of ∼1.4 µm meV −1 and a ∼200 meV window of high-fidelity spectral imaging. The experimentally demonstrated spectral resolution is ∼20 meV; this resolution is twice as low as expected from theory primarily because the spectrograph is highly sensitive to crystal angular instabilities. The experiment was performed at the bending magnet X-ray optics testing beamline 1-BM at the Advanced Photon Source.

Bragg diffraction↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗

C 13 ( n , 2 n γ ) C 12 γ -ray production in the 14–16 MeV incident neutron energy range

We report γ-ray emission from 12 C and 13 C samples irradiated with deuterium-tritium fusion neutrons was experimentally measured at the Omega Laser Facility and at the Ohio University Edwards Accelerator Laboratory. The intent of these measurements was to determine the feasibility of using 13 C-based plastic ablators with embedded 12 C layers for “dark mix” diagnosis of inertial confinement fusion implosions. Spectrally resolved measurements at Ohio University identified significant 4.44-MeV γ-ray emission from the 13 C(n, 2nγ) 12 C-L1 reaction channel. The recorded 4.44-MeV 13 C signal was compared against emission from an identically irradiated 12 C target with known 12 C(n, n'γ) 12 C-L1 cross section, which resulted in an average 13 C(n, 2nγ) 12 C-L1 cross section of 117 ± 17 mb over the incident neutron energy distribution range from 14.4 to 15.8 MeV. Integrated 13C γ -ray signals above 2.9 MeV recorded with the Gas Cherenkov Detector at Omega exceeded MCNP6.1 predictions by a factor of 3. The additional signal was attributed to 4.44-MeV γs resulting in an inferred 13 C(n, 2nγ) 12 C-L1 cross section of 95 ± 11 mb at 14.1-MeV average incident neutron energy. As a result, the 13 C-based “dark mix” diagnostic concept was deemed infeasible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the neutron cross section on argon between 95 and 720 MeV

We report an extended measurement of the neutron cross section on argon in the energy range of 95-720 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. Compared to an earlier analysis of the same data, this extended analysis includes a reassessment of systematic uncertainties, in particular related to unused wires in the upstream part of the detector. Using this information we doubled the fiducial volume in the experiment and increased the statistics by a factor of 2.4. Here we also shifted the analysis from energy bins to time-of-flight bins. This change reduced the overall considered energy range, but improved the understanding of the energy spectrum of incoming neutrons in each bin. Overall, the new measurements are extracted from a fit to the attenuation of the neutron flux in five time-of-flight regions: 140ns-180ns, 120ns-140ns, 112ns-120ns, 104ns-112ns, 96ns-104ns. The final cross sections are given for the flux-averaged energy in each time-of-flight bin with statistical and systematic (syst) uncertainties: σ(146 MeV) = 0.60 $^{+0.14}_{-0.14}$ ±0.08(syst) b, σ(236 MeV) = 0.72 $^{+0.10}_{-0.10}$ ± 0.04(syst) b, σ(319 MeV) = 0.80 $^{+0.13}_{-0.12}$ ±0.040(syst) b, σ(404 MeV) = 0.74 $^{+0.14}_{-0.09}$ ±0.04(syst) b, σ(543 MeV) = 0.74 $^{±0.09}_{-0.09}$ ± 0.04(syst) b.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reaching For New Physics With MeV-scale Reconstruction In The MicroBooNE LArTPC Neutrino Detector

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by reconstructing MeV-Scale energy depositions, or blips, in their data. We demonstrate new calorimetric and particle discrimination capabilities at the MeV scale using reconstructed blips in MicroBooNE LArTPC data at Fermilab. A concentration of low-energy ($<$3 MeV) blips is observed around fiberglass mechanical support struts along the TPC edges, with spectral features consistent with the Compton edge of the 2.614 MeV $^{208}$Tl decay $\gamma$ ray. With these features we perform the electron energy scale calibration to few-percent precision and yield the specific activity of $^{208}$Tl in the struts, $(11.7 \pm 0.2 \text{(stat)} \pm 2.8 \text{(syst)})$ Bq/kg. Using cosmogenic blips above 3 MeV, we demonstrate the ability of large LArTPCs to discriminate low-energy proton and electron depositions. An enriched low-energy proton sample selected with this technique is smaller in data than in dedicated CORSIKA simulations, pointing to possible mismodeling in CORSIKA incident cosmic fluxes or Geant4 particle transport. These methods are applied to MicroBooNE's inclusive single-photon search, which reported a 2.2$\sigma$ excess below 600 MeV in shower energy for events with no reconstructed protons. By identifying and classifying blips near single-photon events selected by the WireCell reconstruction framework, a more comprehensive labeling of nearby hadronic activity is established: blips upstream of the shower axis indicate previously unidentified final-state protons, while elevated blip counts at wide angles signal final-state neutrons. Taken together with MiniBooNE's long-standing low-energy excess (LEE) and MicroBooNE electron-like and sterile neutrino searches disfavored as possible explanations of the MiniBooNE anomaly, this analysis motivates an expanded exploration of the single-photon channel in Fermilab's short-baseline LArTPC program. This thesis documents the current status of this enhanced analysis, which will form a key part of MicroBooNE's final low-energy-excess results.

Andrade Aldana, Diego Armando [IIT, Chicago (main)↗

Experimental study of energy-dependent angular broadening of MeV electron beams for high-resolution imaging in thick samples

In scanning transmission electron microscopy (STEM), spatial resolution is primarily influenced by the projected size of the electron probe within the specimen. In thin samples, a large semi-convergence angle enables a tightly focused beam and sub-nanometer resolution. However, in thick specimens, resolution is fundamentally limited by transverse beam broadening from multiple large-angle scattering events—for example, a probe with 10 mrad angular divergence can broaden by ∼100 nm over a 10 μm path. Since this broadening scales inversely with beam energy, MeV-STEM offers a promising route for high-resolution imaging in thick materials. To quantitatively assess this effect, we performed high-precision measurements at UCLA’s PEGASUS beamline, characterizing beam divergence and intensity profiles for 3–8 MeV electrons transmitted through a wedged-silicon sample of varying thickness. Our results reconcile discrepancies among analytical models and validate Monte Carlo simulations. Here, we find that increasing beam energy from 3.0 to 5.8 MeV reduces angular broadening by a factor of 2.6, with diminishing returns observed at 7.6 MeV. These findings provide a quantitative framework for optimizing MeV-STEM parameters in high-resolution imaging of thick biological and microelectronic specimens, and for guiding beam energy selection in other advanced imaging modes beyond STEM.

36 MATERIALS SCIENCE↗

Monte Carlo Simulation of Electron Interactions in an MeV-STEM for Thick Frozen Biological Sample Imaging

A variety of volume electron microscopy techniques have been developed to visualize thick biological samples. However, the resolution is limited by the sliced section thickness (>30–60 nm). To preserve biological samples in a hydrated state, cryo-focused ion beam scanning electron microscopy has been developed, providing nm resolutions. However, this method is time-consuming, requiring 15–20 h to image a 10 μm thick sample with an 8 nm slice thickness. There is a pressing need for a method that allows the rapid and efficient study of thick biological samples while maintaining nanoscale resolution. The remarkable ability of mega-electron-volt (MeV) electrons to penetrate thick biological samples, even exceeding 10 μm in thickness, while maintaining nanoscale resolution, positions MeV-STEM as a suitable microscopy tool for such applications. Our research delves into understanding the interactions between MeV electrons and frozen biological specimens through Monte Carlo simulations. Single elastic scattering, plural elastic scattering, single inelastic scattering, and plural inelastic scattering events have been simulated. The electron trajectories, the beam profile, and the intensity change of electrons in each category have been investigated. Additionally, the effects of the detector collection angle and the focal position of the electron beam were investigated. As electrons penetrated deeper into the specimen, single and plural elastic scattered electrons diminished, and plural inelastic scattered electrons became dominant, and the beam profile became wider. Even after 10 μm of the specimen, 42% of the MeV electrons were collected within 10 mrad. This confirms that MeV-STEM can be employed to study thick biological samples.

electron specimen interaction↗

Stable and tunable MeV $$\gamma$$-ray generation via dual-laser inverse Thomson scattering from a laser-plasma accelerator

Abstract Inverse Thomson scattering from laser-plasma accelerators offers a pathway to compact, tunable MeV $$\gamma$$ -ray sources for reduced-dose radiography and enhanced performance in nuclear resonance fluorescence (NRF)-based isotope identification. However, photon yield and spectral quality are often limited by constraints on interaction geometry and scatter-laser tunability. Here we demonstrate a MeV $$\gamma$$ -ray source based on a dual-laser inverse Thomson scattering configuration driven by a 100-TW laser-plasma accelerator. Electron beams tunable from 122 to 204 MeV with $$<5$$ mrad divergence and $$<1$$ mrad pointing stability generate $$\gamma$$ rays with peak energies from 276 keV to 1.2 MeV and yields up to $$2\times 10^{7}$$ photons per shot. By independently controlling the interaction position and the scatter-pulse duration, we experimentally match the scatter pulse to the walk-off-limited interaction length. Extending the scatter pulse to 200 fs increases photon production by approximately $$15\%$$ while maintaining operation in the linear Thomson regime, thereby preserving narrow spectral bandwidth and controlled radiation divergence. Radiographic characterization demonstrates MeV-level penetration and $$\approx 0.1$$ mm spatial resolution, while stable operation is sustained over multi-hour timescales across multiple days. These results show that interaction-length optimization provides a scalable strategy for improving photon yield, spectral control, and operational stability in compact laser-plasma-accelerator-driven $$\gamma$$ -ray sources.

Tsai, Hai-En↗

Self-driven ion deflectometry measurements using MeV fusion-driven protons and accelerated deuterons in the deuterated hybrid x-pinch on the MAIZE LTD generator

Abstract We report on the results of point-projection ion deflectometry measurements from a mid-size university z-pinch experiment. A 1 MA 8 kJ LTD generator at the University of Michigan (called MAIZE) drove a hybrid x-pinch (HXP) with a deuterated polyethylene fiber load to produce a point-like source of MeV ions for backlighting. In these experiments, 2.7 MeV protons were generated by DD beam-target fusion reactions. Due to the kinematics of beam-target fusion, the proton energies were down-shifted from the more standard 3.02 MeV proton energy that is released from the center-of-mass rest frame of a DD reaction. In addition to the 2.7 MeV protons, strongly anisotropic beams of 3 MeV accelerated deuterons were detected by ion diagnostics placed at a radial distance of 90 mm from the x-pinch. Numerical reconstruction of experimental data generated by deflected hydrogen ion trajectories evaluated the total current in the vacuum load region. Numerical ion-tracking simulations show that accelerated deuteron beams exited the ion source region at large angles with respect to the pinch current direction.

Physics↗

Demonstration of new MeV-scale capabilities in large neutrino LArTPCs using ambient radiogenic and cosmogenic activity in MicroBooNE

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by reconstructing and interpreting MeV-scale energy depositions, or blips, present in their data. We demonstrate new calorimetric and particle discrimination capabilities at the MeV energy scale using reconstructed blips in data from the MicroBooNE LArTPC at Fermilab. We observe a concentration of low-energy (<3 MeV) blips around fiberglass mechanical support struts along the time projection chamber edges with energy spectrum features consistent with the Compton edge of 2.614 MeV 208 Tl decay 𝛾 rays. These features are used to verify proper calibration of electron energy scales in MicroBooNE’s data to few percent precision and to measure the specific activity of 208 Tl in the fiberglass composing these struts, (11.7 ± 0.2⁢(stat) ± 3.1⁢(syst)) Bq/kg. Cosmogenically produced blips above 3 MeV in reconstructed energy are used to showcase the ability of large LArTPCs to distinguish between low-energy proton and electron energy depositions. An enriched sample of low-energy protons selected using this new particle discrimination technique is found to be smaller in data than in dedicated corsika cosmic-ray simulations, suggesting either incorrect corsika modeling of incident cosmic fluxes or particle transport modeling issues in geant4.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser-driven high-resolution MeV x-ray tomography

The need for high-resolution MeV x-ray tomography to observe the three-dimensional structure of dense, large-sized objects is rapidly increasing for the non-destructive evaluation of critical additively manufactured parts, national security, and other applications. We report a demonstration of high-resolution MeV computed tomography of a dense, large object with a laser-driven x-ray source. A record detector-limited MeV radiograph resolution of < 200 µm as determined with the Bennett approximation of the point spread function was achieved by irradiating millimeter-thick tungsten targets with 300 TW femtosecond laser pulses at a 0.5 Hz repetition rate. A tungsten alloy step wedge spectrometer indicates that the peak of the x-ray emission is between 1 and 2 MeV, with an endpoint energy of 19 MeV. To illustrate the radiographic imaging capability of the system, a tomographic reconstruction of a nickel superalloy turbine blade ( maximum $ρr$ = 139 g/cm 2 ) with sub-millimeter resolution was performed using 2160 individual radiographs. The small x-ray source size opens the prospect of extremely high-resolution tomographs of large, dense objects. This laser-driven approach has major advantages for non-destructive evaluation.

47 OTHER INSTRUMENTATION↗

New MeV-Scale Capabilities in Large Neutrino LArTPCs Using Ambient Radiogenic and Cosmogenic Activity in MicroBooNE

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by reconstructing and interpreting MeV-scale energy depositions present in their data. We use data from MicroBooNE, an 85 tonnes LArTPC exposed to Fermilab neutrino beams from 2015 until 2021, to demonstrate new calorimetric and particle discrimination capabilities for isolated $\sim \mathrm{O}(1 \mathrm{MeV})$ energy depositions referred to as blips. We observe a concentration of low energy ( $<3$ MeV ) blips around fiberglass mechanical support struts along the TPC edges with energy spectrum features consistent with the Compton edge of 2.614 MeV Tl-208 decay gamma rays. These features are used to verify proper calibration of electron energy scales in MicroBooNE's data to few percent precision and to measure the specific activity of Tl-208 in the fiberglass composing these struts. Cosmogenicallyproduced blips above 3 MeV in reconstructed energy are used to showcase the ability of large LArTPCs to distinguish between low-energy proton and electron energy depositions.

Andrade Aldana, Diego Armando↗

Conceptual Design of a Thermal–to-14-MeV Neutron Conversion Device for Use in the Advanced Test Reactor

Here, this paper details the conceptual design of a thermal-to-14-MeV neutron converter consisting of a mixture of lithium and deuterium in a blanket material. Such a device operates a two-step reaction, first generating tritons via thermal neutron absorption in the tritium breeding material, and in the second step, high-energy neutrons are produced either via deuterium-tritium fusion reaction or with tritium reacting with lithium. A thermal-to-14-MeV neutron converter significantly hardens the neutron spectrum by virtually removing thermal neutrons and adding a high-energy 14 MeV component to the neutron spectrum. While similar concepts have been previously proposed and tested in other reactors, the unique characteristics of the Advanced Test Reactor (ATR), namely its important thermal flux (up to $10^{15}$ n.cm$^{-2}$.s$^{-1}$) makes it markedly attractive for obtaining a very large fast neutron flux, usable for irradiation studies under neutron flux conditions prototypical of fusion reactors. The paper provides a description of a new computational scheme developed for handling the coupled neutron-triton transport mechanism using the Geant4 toolkit. Resulting neutron spectra and high-energy neutron yields are summarized for different irradiation positions and potential neutron breeder materials. Maximum predicted thermal-to-14-MeV neutron yields are on the order of $2.10^{-4}$, which is consistent with previous studies found in the literature. Thus, when placed inside the ATR, such a neutron converter will be providing the largest high-energy neutron source available for activation and irradiation studies of materials foreseen for use in fusion reactors. Future steps will involve qualifying the computational scheme using the ATR critical facility using activation foil measurements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗