Search NASA⌕ Search

SEARCH · Search NASA

Results for “MINERVE REACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

22 records · Page 2

Analysis and recent advances in gamma heating measurements in MINERVE facility by using TLD and OSLD techniques

The objective of this study is to develop nuclear heating measurement methods in Zero Power experimental reactors. This paper presents the analysis of Thermo-Luminescent Detector (TLD) and Optically Stimulated Luminescent Detectors (OSLD) experiments in the UO{sub 2} core of the MINERVE research reactor at the CEA Cadarache. The experimental sources of uncertainties on the gamma dose have been reduced by improving the conditions, as well as the repeatability, of the calibration step for each individual TLD. The interpretation of these measurements needs to take into account calculation of cavity correction factors, related to calibration and irradiation configurations, as well as neutron corrections calculations. These calculations are based on Monte Carlo simulations of neutron-gamma and gamma-electron transport coupled particles. TLD and OSLD are positioned inside aluminum pillboxes. The comparison between calculated and measured integral gamma-ray absorbed doses using TLD, shows that calculation slightly overestimates the measurement with a C/E value equal to 1.05 {+-} 5.3 % (k = 2). By using OSLD, the calculation slightly underestimates the measurement with a C/E value equal to 0.96 {+-} 7.0% (k = 2. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of gamma-ray dosimetry experiments in the zero power MINERVE facility

The objective of this study is to develop nuclear heating measurement methods in zero power experimental reactors. These developments contribute to the qualification of photonics calculation schemes for the assessment of gamma heating in the future Jules Horowitz Material Testing Reactor. This paper presents the analysis of thermoluminescent detector (TLD) experiments in the UO{sub 2} core of the MINERVE Research Reactor at the French Alternative Energies and Atomic Energy Commission center in Cadarache. The experimental sources of uncertainty in the gamma dose have been reduced by improving the measurement conditions and the repeatability of the calibration step for each individual TLD. The interpretation of these measurements needs to take into account the calculation of cavity correction factors related to calibration and irradiation configurations, as well as neutron correction calculations. These calculations are based on Monte Carlo simulations of neutron-gamma and gamma-electron transport coupled particles. The comparison between calculated and measured integral gamma-ray absorbed doses in the aluminum material surrounding the TLD shows that calculations slightly overestimate the measurement, with a calculated versus experimental ratio equal to 1.04 {+-} 5.7 % (k=2). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

OSMOSE experiment representativity studies.

The OSMOSE program aims at improving the neutronic predictions of advanced nuclear fuels through measurements in the MINERVE facility at the CEA-Cadarache (France) on samples containing the following separated actinides: Th-232, U-233, U-234, U-235, U-236, U-238, Np-237, Pu-238, Pu-239, Pu-240, Pu-241, Pu-242, Am-241, Am-243, Cm-244 and Cm-245. The goal of the experimental measurements is to produce a database of reactivity-worth measurements in different neutron spectra for the separated heavy nuclides. This database can then be used as a benchmark for integral reactivity-worth measurements to verify and validate reactor analysis codes and integral cross-section values for the isotopes tested. In particular, the OSMOSE experimental program will produce very accurate sample reactivity-worth measurements for a series of actinides in various spectra, from very thermalized to very fast. The objective of the analytical program is to make use of the experimental data to establish deficiencies in the basic nuclear data libraries, identify their origins, and provide guidelines for nuclear data improvements in coordination with international programs. To achieve the proposed goals, seven different neutron spectra can be created in the MINERVE facility: UO2 dissolved in water (representative of over-moderated LWR systems), UO2 matrix in water (representative of LWRs), a mixed oxide fuel matrix, two thermal spectra containing large epithermal components (representative of under-moderated reactors), a moderated fast spectrum (representative of fast reactors which have some slowing down in moderators such as lead-bismuth or sodium), and a very hard spectrum (representative of fast reactors with little moderation from reactor coolant). The different spectra are achieved by changing the experimental lattice within the MINERVE reactor. The experimental lattice is the replaceable central part of MINERVE, which establishes the spectrum at the sample location. This configuration leads to a uniform well-behaved system so that the reactor configuration is in the fundamental mode. In fact, an important property of the oscillation experiments performed in the OSMOSE program is that the neutron flux at the sample location has reached the asymptotic fundamental mode of the MINERVE lattice. This property allows the use of simple spatial methods for the analysis (e.g. a lattice code with axial buckling representing the leakage), without loss of accuracy. The computational challenge is then reduced to the need of an appropriate cross-section processing and of accurate resonance shielding algorithms. In the present study, calculations have been performed to investigate the similarity of the flux spectra at the sample position of different OSMOSE configurations with the neutron energy distributions characterizing existing thermal and fast reactors proposed under the advanced reactor programs Gen-IV, GNEP and NGNP.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SPECTRON, a neutron noise measurement system in frequency domain

This paper is dedicated to the presentation and validation of SPECTRON, a novel neutron noise measurement system developed at CEA Cadarache. The device is designed for the measurement of the β{sub eff} parameter (effective fraction of delayed neutrons) of experimental nuclear reactors using the Cohn-α method. An integrated electronic system is used to record the current from fission chambers. Spectra computed from measurement data are processed by a dedicated software in order to estimate the reactor transfer function and then the effective fraction of delayed neutrons as well as the prompt neutron generation time. After a review of the pile noise measurement method in current mode, the SPECTRON architecture is presented. Then, the validation procedure is described and experimental results are shown, supporting the proper functioning of this new measurement system. It is shown that every technical requirement needed for correct measurement of neutron noise is fulfilled. Measurements performed at MINERVE and EOLE, two experimental nuclear reactors at CEA Cadarache, in real conditions allowed us to validate SPECTRON.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗